Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shape evolution of neutron-rich 106,108,110 Mo isotopes in the triaxial degree of freedom

Background: Neutron-rich nuclei with mass number between 100 and 110 attract much attention, since several kinds of shapes, such as spherical, prolate, oblate, and triaxial shapes, are predicted. In particular, for neutron-rich Mo isotopes, different models predict different magnitudes and rigidity of triaxial deformation. Previous interpretations of experimental results based solely on low-lying $2^+_2$ states are insufficient to distinguish between the rigid triaxial shape, $\gamma$ vibration, or $\gamma$-soft rotor. Purpose: The shape evolution of 106 Mo, 108 Mo, and 110 Mo is investigated through their $2^+_1$-state lifetimes, decay-branching ratios of the $2^+_2$ state, and energies of the low-lying collective excited states with $K^π = 0^+, 2^+$, and $4^+$. Method: $\beta$-delayed $\gamma$-ray spectroscopy was employed for neutron-rich Nb and Zr isotopes produced at the RIKEN RI Beam Factory to populate excited states in 106 Mo, 108 Mo, and 110 Mo. The EUroball-RIKEN Cluster Array was used for high-resolution $\gamma$-ray detection and lifetimes of the $2^+_1$ states were determined using the UK fast-timing array of LaBr 3 (Ce) detectors. Results: New $\gamma$-ray transitions and levels are reported, including newly assigned $0^+_2$ states in 108,110 Mo. Quadrupole deformations were obtained for 106,108,110 Mo from their $2^+_1$ energies and lifetimes. The $\beta$-delayed neutron-emission probabilities of 108 Nb and 110 Nb were determined by examining the $\gamma$ rays of their respective daughter decays. Conclusions: In this work, the even-odd energy staggering in the $2^+_2$ band was compared with typical patterns of the $\gamma$-vibrational band, rigid triaxial rotor, and $\gamma$-soft rotor. The very small even-odd staggering of 106 Mo, 108 Mo, and 110 Mo favors a $\gamma$-vibrational band assignment. The kinematic moment of inertia for the $2^+_2$ band showed a trend similar to the ground-state band, which is as expected for the $\gamma$-vibrational band. Beyond-mean-field calculations employing the constrained Hartree-Fock-Bogoliubov and local quasiparticle-random-phase approximation method using the SLy5 + T interaction reproduced the ground and $2^+_2$ bands in 106 Mo and 108 Mo. The collective wave functions are consistent with the interpretation of the $2^+_2$ band as the $\gamma$-vibrational band of the prolate shape. However, the staggering pattern observed in 110 Mo differs from the one suggested in the calculations which predict a $\gamma$-soft rotor. There was no experimental indication of the oblate shape or the $\gamma$-soft rotor predicted in these Mo isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Use of a Longitudinally Polarized Target with CLAS12

Run Group C comprises eight experiments utilizing the CLAS12 detector system in Hall B at Jefferson Lab to study the multidimensional partonic structure of nucleons. The experiments scatter electrons from polarized protons and neutrons in samples of solid NH$_3$ and ND$_3$, dynamically polarized at a temperature of 1 K in a 5 T magnetic field. After a brief description of the target system, the current status of the target and preliminary results of its performance in the experiment are presented.

Keith, Christopher↗

Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report

Here, this report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions. This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(U) Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-METFAST-086) identifies two corrections that need to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-METFAST-086 Case 4 in order to estimate the effect on k eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused k eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF-B/VIII.0, have also been used; this caused k eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil and at three external point detectors. Within the fission foil, using ENDF/B-VIII.0 for Godiva-IV induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the point detectors, using ENDF/B-VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in k eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Experimental observation and integrated modelling of proton-beryllium fusion in He and D plasmas at JET

Validated integrated modelling of JET ITER-like wall experiments in which fusion performance is driven by reactions between fast ions and intrinsically present metal wall impurities is presented. A steady-state L-mode plasma with dominant proton-beryllium fusion and neutron yields of up to ≈ 6·10 13 s -1 is developed in He and D, via radiofrequency heating of a H minority. The fusion drive is unambiguously confirmed by the neutral particle analyser, fast ion loss detector, and γ-ray diagnostics. Experiments are analysed via an integrated modelling framework, developed to model the two-stage proton beryllium-fusion chain and produce high-fidelity fusion product source terms. The modelling chain comprises TRANSP and JETTO for plasma core modelling, LOCUST for full orbit product tracking and collisional slowing-down, DRESS to resolve two- and three-body fusion kinematics, and MCNP for neutron transport calculations. Modelling shows that the primary 9 Be(p,n) 9 B reaction is the dominant neutron emitter at naturally present concentrations of beryllium in these experiments. The yield contribution of secondary reactions between fusion products and beryllium, 9 Be(d,n) 10 B and 9 Be(α,n) 12 C, is found to be negligible. The proton-deuteron knock-on effect in D plasmas is modelled, which is calculated to contribute ≈ 25% to the total neutron yield. For both He and D discharges the total computed neutron rates match fission chamber (FC) measurements within the combined experimental and computational uncertainty, with an average discrepancy of ≈ ± 20%. Realistic proton-beryllium neutron sources are propagated through JET’s MCNP neutron transport model which shows that 235 U FCs’ response is sensitive to p–Be source changes, with up to ≈ 10% variation compared to a D–D neutron source. We show that the high-energy tail of the fast proton minority can be studied with multi-foil neutron activation. The framework is also applied to the study of interactions between fast protons and boron impurities, of relevance to ITER. We calculate that in JET conditions a significant alpha source with DT-like energies could be generated through 11 B(p, α)2α fusion, and detected via γ-emission in secondary interactions between fast alphas and boron. The work represents an important step towards validating predictive integrated modelling capabilities for non-standard fusion reactions.

JET↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inference of the neutron down-scatter ratio using neutron time-of-flight data for DT-layered implosions on the OMEGA laser

First analysis of the neutron time of flight (nTOF) data is presented to infer the areal density using the neutron down-scatter ratio (DSR) for OMEGA deuterium–tritium (DT)-layered (cryogenic) implosions. The required very-high-dynamic range (nTOF) signal is constructed using an nTOF detector [Forrest et al., Rev. Sci. Ins. 83, 10D919 (2012)] with multiple time-gated photomultiplier tubes. The nTOF data are analyzed using a forward-fit technique to account for the detector responses and infer the DSR and areal density for DT-layered implosions. The areal densities inferred using this analysis are found to be in agreement with the areal densities measured using the magnetic recoil spectrometer detector that is located in a similar line-of-sight. This work establishes the feasibility of the DSR measurement using nTOF data on OMEGA and provides an additional areal-density measurement that will benefit the assessment of the implosion performance and 3D reconstruction of the imploded core.

47 OTHER INSTRUMENTATION↗

Performance Benchmark of Commercial and Developmental Fission Chambers in Elevated Temperatures

This report documents the testing of two in-core fission chamber technologies for high-temperature irradiation environments. This work is in collaboration with the French Alternative Energies and Atomic Energy Commission (CEA). The fission chamber evaluated by Idaho National Laboratory is the micro-pocket fission detector (MPFD). The fission chamber evaluated by the CEA are the 3 mm miniaturized fission chamber and the 7 mm high-temperature fission chamber. Demonstrations of the MPFD were performed at the Neutron Radiography Facility and the Massachusetts Institute of Technology Reactor. Demonstrations of the CEA fission chambers were performed at the Ohio State University Research Reactor. All demonstrations were conducted with a heated experiment rig up to 850°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of areal density asymmetries on scattered neutron spectra in ICF implosions

Scattered neutron spectroscopy is a diagnostic technique commonly used to measure areal density in inertial confinement fusion experiments. Deleterious areal density asymmetries modify the shape of the scattered neutron spectrum. In this work, a novel analysis is developed, which can be used to fit the shape change. This will allow experimental scattered neutron spectroscopy to directly infer the amplitude and mode of the areal density asymmetries, with little sensitivity to confounding factors that affect other diagnostics for areal density. The model is tested on spectra produced by a neutron transport calculation with both isotropic and anisotropic primary fusion neutron sources. Multiple lines of sight are required to infer the areal density distribution over the whole sphere—we investigate the error propagation and optimal detector arrangement associated with the inference of mode 1 asymmetries.

Crilly, A. J. (ORCID:0000000204299332)↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular Dependence of Drell-Yan in the SeaQuest Experiment using Deep Neural Network-Based Reconstruction

The SeaQuest and SpinQuest experiments at Fermilab were designed to probe the internal dynamics of protons and neutrons via the angular dependence of muons created by colliding 120 GeV protons into stationary targets. To do this, it is necessary to translate the detector data into coherent information about the particles detected in the experiment. This dissertation describes the development and implementation of QTracker, a neural network-based algorithm designed to reconstruct muons. The application of QTracker to experimental data yields improved reconstruction of muon tracks, allowing for a more precise investigation of the transverse momentum distributions and angular modulations in the Drell-Yan process. This work highlights the potential of neural network-based methods to advance particle tracking and enhance our understanding of nucleon structure.

Conover, Arthur↗

A Possible Neutron-Antineutron Oscillation Experiment at PF1B at the Institut Laue Langevin

We consider a possible neutron–antineutron ($n-\overline{n}$) oscillation experiment at the PF1B instrument at Institut Laue Langevin. It can improve the best existing constraint on the transition rate and also allow the testing of the methods and instrumentation which would be needed for a later larger-scale experiment at ESS. The main gain factors over the most competitive experiment, performed earlier at PF1 instrument at ILL, are: a more intense neutron beam and a new operating mode based on coherent n and $\overline{n}$ mirror reflections. The installation of such an experiment would need a temporary replacement of the existing ballistic neutron guide by a specially designed n/$\overline{n}$ guide with a gradually increasing cross section and a specially selected coating as well as the development and construction of an advanced $\overline{n}$ annihilation detector with a high efficiency and low background. The overall gain factor could reach up to an order of magnitude and depends on the chosen experiment configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of collective rotational bands in neutron-rich 142 La and the study of octupole/triaxial deformations in 142,143 La

Collective rotational bands were observed for the first time in neutron-rich odd–odd 142 La by means of γ-γ-γ and γ-γ-γ-γ coincidence measurements of prompt fission γ rays from 252 Cf using multi-detector array Gammasphere. Similarity between the yrast band of 142 La and those of neighboring 144 La, 144 Ce was found and interpreted as quasiparticle excitations. Here, PES calculations suggested triaxial deformation for the ground state of 142La. Considerable triaxial and near zero octupole deformations were deduced for the yrast band of 142 La by the TRS model calculations. The band-crossing observed in the yrast band of 142 La was interpreted to be caused by alignment of the (h 11/2 ) 2 proton pair, and the crossing frequency was best reproduced by the TRS calculations taking into account triaxial deformations. In contrast to the interpretations for the band crossing of 142 La, alignments of the (i 13/2 ) 2 neutron pair were found to be responsible for the band-crossing of the yrast band in the neighboring even-N 143 La, and triaxial degree of freedom was found to play a more significant role than octupole deformations in the nucleus, although its β 3 values deduced are large.

142La↗