Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

New experimental limits on the probabilities of pauli-forbidden transitions in the {sup 12}C nucleus from data obtained with the borexino detector

The Pauli exclusion principle was tested for nucleons in the {sup 12}C nucleus by using data from the Borexino detector. The approach used consisted in seeking photons, neutrons, and protons, as well as electrons and positrons, emitted in the Pauli-forbidden transitions of nucleons from the 1P{sub 3/2} shell to the filled 1S{sub 1/2} shell. Owing to a uniquely low background level in the Borexino detector and its large mass, the currently most stringent experimental limits were obtained for the probabilities and relative intensities of Pauli-forbidden transitions for the electromagnetic, strong, and weak channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Martian Neutron Energy Spectrometer (MANES)

High energy charged particles of extragalactic, galactic, and solar origin collide with spacecraft structures and planetary atmospheres. These primaries create a number of secondary particles inside the structures or on the surfaces of planets to produce a significant radiation environment. This radiation is a threat to long term inhabitants and travelers for interplanetary missions and produces an increased risk of carcinogenesis, central nervous system (CNS) and DNA damage. Charged particles are readily detected; but, neutrons, being electrically neutral, are much more difficult to monitor. These secondary neutrons are reported to contribute 30-60% of the dose equivalent in the Shuttle and MIR station. The Martian atmosphere has an areal density of 37 g/sq cm primarily of carbon dioxide molecules. This shallow atmosphere presents fewer mean free paths to the bombarding cosmic rays and solar particles. The secondary neutrons present at the surface of Mars will have undergone fewer generations of collisions and have higher energies than at sea level on Earth. Albedo neutrons produced by collisions with the Martian surface material will also contribute to the radiation environment. The increased threat of radiation damage to humans on Mars occurs when neutrons of higher mean energy traverse the thin, dry Martian atmosphere and encounter water in the astronaut's body. Water, being hydrogeneous, efficiently moderates the high energy neutrons thereby slowing them as they penetrate deeply into the body. Consequently, greater radiation doses can be deposited in or near critical organs such as the liver or spleen than is the case on Earth. A second significant threat is the possibility of a high energy heavy ion or neutron causing a DNA double strand break in a single strike.

Maurer, R. H.↗

Dynamic Neutron Scattering by Biological Systems

Dynamic neutron scattering directly probes motions in biological systems on femtosecond to microsecond timescales. When combined with molecular dynamics simulation and normal mode analysis, detailed descriptions of the forms and frequencies of motions can be derived. We examine vibrations in proteins, the temperature dependence of protein motions, and concepts describing the rich variety of motions detectable using neutrons in biological systems at physiological temperatures. In conclusion, new techniques for deriving information on collective motions using coherent scattering are also reviewed.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Dynamics in Ionic-Liquid-Based Li-Ion Electrolytes Investigated by Neutron Scattering and Dielectric Spectroscopy

A detailed understanding of the diffusion mechanisms of ions in pure and doped ionic liquids remains an important aspect in the design of new ionic-liquid electrolytes for energy storage. Here, to gain more insight into the widely used imidazolium-based ionic liquids, the relationship between viscosity, ionic conductivity, diffusion coefficients, and reorientational dynamics in the ionic liquid 3-methyl-1-methylimidazolium bis(trifluoromethanesulfonyl)imide (DMIM-TFSI) with and without lithium bis(trifluoromethanesulfonyl)imide (Li-TFSI) was examined. The diffusion coefficients for the DMIM + cation and the role of ion aggregates were investigated by using the quasielastic neutron scattering (QENS) and neutron spin echo techniques. Two diffusion mechanisms are observed for the DMIM + cation with and without Li-TFSI, that is, translational and local. The data additionally suggest that Li + ion transport along with ion aggregates, known as the vehicle mechanism, may play a significant role in the ion diffusion process. These dielectric-spectroscopy investigations in a broad temperature and frequency range reveal a typical α–β-relaxation scenario. The α relaxation mirrors the glassy freezing of the dipolar ions, and the β relaxation exhibits the signatures of a Johari–Goldstein relaxation. In contrast to the translational mode detected by neutron scattering, arising from the decoupled faster motion of the DMIM + ions, the α relaxation is well coupled to the dc charge transport, that is, the average translational motion of all three ion species in the material. Finally, the local diffusion process detected by QENS is only weakly dependent on temperature and viscosity and can be ascribed to the typical fast dynamics of glass-forming liquids.

25 ENERGY STORAGE↗

HERSCHEL AND SPITZER OBSERVATIONS OF SLOWLY ROTATING, NEARBY ISOLATED NEUTRON STARS

Supernova fallback disks around neutron stars have been suspected to influence the evolution of the diverse neutron star populations. Slowly rotating neutron stars are the most promising places to find such disks. Searching for the cold and warm debris of old fallback disks, we carried out Herschel PACS (70 μm, 160 mu m) and Spitzer IRAC (3.6 μm, 4.5 μm) observations of eight slowly rotating (P ≈ 3-11 s) nearby (<1 kpc) isolated neutron stars. Herschel detected 160 μm emission (>5σ) at locations consistent with the positions of the neutron stars RX J0806.4-4123 and RX J2143.0+0654. No other significant infrared emission was detected from the eight neutron stars. We estimate probabilities of 63%, 33%, and 3% that, respectively, none, one, or both Herschel PACS 160 μm detections are unrelated excess sources due to background source confusion or an interstellar cirrus. If the 160 μm emission is indeed related to cold (10-22 K) dust around the neutron stars, this dust is absorbing and re-emitting ∼10% to ∼20% of the neutron stars' X-rays. Such high efficiencies would be at least three orders of magnitude larger than the efficiencies of debris disks around nondegenerate stars. While thin dusty disks around the neutron stars can be excluded as counterparts of the 160 μm emission, dusty asteroid belts constitute a viable option.

79 ASTRONOMY AND ASTROPHYSICS↗

KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s

The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low-lying level structure of the neutron-unbound $\textit{N}$ = 7 isotones

This article reports on results of an experimental search for ground state shell inversion in the neutron-unbound $\textit{N}$ = 7 isotones 9 He and 10 Li. Two different radioactive ion beams ( 11 Be, E lab = 44 MeV/u and 12 B, E lab = 45 MeV/u) impinging on a beryllium target were used to directly and selectively populate unbound states of a given ℓ in the nuclides of interest. Be( 11 Be, 8 He + $\textit{n}$) and Be( 12 B, 8 He + $\textit{n}$) reactions populated unbound states in 9 He. Fragments and neutrons were detected in coincidence to reconstruct the decay energy of 9 He using invariant mass spectroscopy. Similarly, Be( 11 Be, 9 Li + $\textit{n}$) and Be( 12 B, 9 Li + $\textit{n}$) reactions were used to populate unbound states in 10 Li, and the time-of-flight method was used to determine the relative velocity of the 9 Li fragments and neutrons in coincidence. Various states in both 9 He and 10 Li were observed and characterized. Here, the data indicate possible ground state shell inversion in both cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrahigh energy neutrinos from galactic neutron stars

An attempt is made to estimate the production rate of ultrahigh energy (UHE) neutrinos from galactic neutron stars. The statistics of various stellar populations are reviewed as well as an evolutionary scheme linking several neutron star environments. An observational test for predicting stellar evolution is made using two mass ratio intervals of less than 0.3 and greater than or approximately equal to 0.3, which is supported by kinematical evidence. Attention is given to the problem of the target material that is required by UHE protons accelerated from the pulsar's surface to their rotational kinetic energy, and to the detectability of neutron stars in the UHE neutrinos by employing the deep underwater muon and neutrino detector (DUMAND) array.

Helfand, D. J.↗

POWGEN: a third-generation high resolution high-throughput powder diffraction instrument at the Spallation Neutron Source

Powgen represents a departure from previous designs for a time-of-flight powder diffractometer at a spallation neutron source and may be considered a third-generation design. The instrument is optimized for both parametric studies of materials under a wide range of conditions (T, P, H, flowing gases, etc) and ab-initio crystal structure determinations of complex solid-state materials with asymmetric unit-cells of the order {approx}1500 {angstrom}{sup 3}. The geometric design of the instrument allows for all detected scattered neutrons to be focused onto a single diffraction profile yielding high count rate while preserving good resolution {Delta}d/d = 0.0015 at a d = 1 {angstrom}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Radioactively powered emission from black hole-neutron star mergers

Detection of the electromagnetic counterparts of gravitational wave (GW) sources is important to unveil the nature of compact binary coalescences. We perform three-dimensional, time-dependent, multi-frequency radiative transfer simulations for radioactively powered emission from the ejecta of black hole (BH)-neutron star (NS) mergers. Depending on the BH to NS mass ratio, spin of the BH, and equations of state of dense matter, BH-NS mergers can eject more material than NS-NS mergers. In such cases, radioactively powered emission from the BH-NS merger ejecta can be more luminous than that from NS-NS mergers. We show that, in spite of the expected larger distances to BH-NS merger events, the observed brightness of BH-NS mergers can be comparable to or even higher than that of NS-NS mergers. We find that, when the tidally disrupted BH-NS merger ejecta are confined to a small solid angle, the emission from BH-NS merger ejecta tends to be bluer than that from NS-NS merger ejecta for a given total luminosity. Thanks to this property, we might be able to distinguish BH-NS merger events from NS-NS merger events by multi-band observations of the radioactively powered emission. In addition to the GW observations, such electromagnetic observations can potentially provide independent information on the progenitors of GW sources and the nature of compact binary coalescences.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin-energy entanglement of a time-focused neutron

Intraparticle entanglement of individual particles such as neutrons could enable another class of scattering probes that are sensitive to entanglement in quantum systems and materials. Here, in this work, we present experimental results demonstrating quantum contextuality as a result of entanglement between the spin and energy modes (i.e., degrees of freedom) of single neutrons in a beam using a pair of resonant radio-frequency neutron spin flippers in the modulated intensity with zero effort configuration. We verified the mode entanglement by measuring a Clauser-Horne-Shimony-Holt contextuality witness S defined in the spin and energy subsystems, observing a clear breach of the classical bound of |S| ≤ 2, obtaining S = 2.40 ± 0.02. These entangled beams could enable alternative approaches for directly probing dynamics and entanglement in quantum materials whose low-energy excitation scales match those of the incident entangled neutron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of the Neutrino-4 experiment

Monte Carlo simulation of the two-section reactor antineutrino detector of the Neutrino-4 experiment is carried out. The scintillation-type detector is based on the inverse beta-decay reaction. The antineutrino is recorded by two successive signals from the positron and the neutron. The simulation of the detector sections and the active shielding is performed. As a result of the simulation, the distributions of photomultiplier signals from the positron and the neutron are obtained. The efficiency of the detector depending on the signal recording thresholds is calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-in-cell Simulations of Mildly Relativistic Outflows in Kilonova Emissions

Abstract The electromagnetic emission from neutron star mergers is comprised of multiple components. Synchrotron emission from the disk-powered jet and thermal emission from the merger ejecta (powered by a variety of sources) are among the most studied sources. The low masses and high velocities of the merger ejecta quickly develop conditions where emission from collisionless shocks becomes critical and synchrotron emission from the merger ejecta constitutes a third component to the observed signal. The aim of this project is to examine shock development, magnetic field generation, and particle acceleration in the case of mildly relativistic shocks, which are expected when the tidal ejecta of neutron star mergers drive a shock into the external medium. Using LANL’s vector particle-in-cell (VPIC) code, we have run simulations of such mildly relativistic, collisionless, weakly magnetized plasmas and computed the resultant magnetic fields and particle energy spectra. We show the effects of varying plasma conditions, as well as explore the validity of using different proton-to-electron mass ratios in VPIC. Our results have implications for observing late-time electromagnetic counterparts to gravitational wave detections of neutron star mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-barrier wellbore integrity inspection system with eccentricity correction

A downhole inspection system includes a neutron imaging device operable to generate data for detecting potential wellbore anomalies and an electromagnetic imaging device operable to generate data for detecting potential wellbore eccentricity. The neutron imaging device includes a neutron generator operable to emit neutrons, and a neutron detector fixed relative to the neutron generation unit and operable to detect backscattered neutrons from a surrounding environment. The electromagnetic imaging device includes at least one transmitter for generating electromagnetic pulse, and at least one receiver for detecting returning electromagnetic pulse. Correlation of the neutron imaging data with the electromagnetic imaging data provides additional data regarding the potential wellbore anomalies.

Kasten, Ansas Matthias↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗