The Cost of Floating Offshore Wind Energy in California Between 2019 and 2032

California’s energy planning is centered around meeting the emissions reduction and renewable energy requirements of Senate Bill 350 by 2030. However, state power system planning is expected to eventually address California’s requirement to achieve 100% of total retail electricity sales from renewable energy and zero-carbon resources by 2045, as mandated by Senate Bill 100. To comply with these directives, California needs to investigate the further development of energy efficiency, storage, and a diverse range of renewable energy, zero-carbon emission, and transmission resources, including offshore wind. Wind resources off the coast of California have the potential to generate a significant portion of the state’s electric energy as it moves toward a zero-carbon economy and can help diversify its energy mix. Floating offshore wind technology, which is suitable for the deep waters along the California coast, is currently in a precommercial phase, with approximately 84 megawatts (MW) installed worldwide at the end of 2019. Globally there are over 7,000 MW in planning and permitting phases of development, with the first commercial-scale projects expected to be operational in 2024. This study provides site-specific cost and performance data for floating offshore wind to inform California’s long-term energy planning. The identification of new resources to meet California’s policy goals at least cost is part of the Integrated Resource Planning (IRP) process, which is coordinated by the California Public Utilities Commission (CPUC). In 2019–2020 IRP modeling, offshore wind was included for the first time as a candidate resource in some sensitivity cases (CPUC 2019). The data and information presented in this report can be used to update offshore wind inputs in future IRP cycles. The authors conducted a geospatial cost analysis over portions of the offshore wind resource area of California. The analyzed spatial domain includes sites with a mean wind speed of at least 7 meters per second and water depths between 40 meters (m) and 1,300 m. Costs and energy production vary across this analysis domain. We calculated these parameters on a grid layout with over 750 sites, with each site representing a 1,000-MW commercial offshore wind power plant. Levelized cost of energy (LCOE) was calculated at each site over the analysis domain. The resulting variation in LCOE across the analysis domain is illustrated through heat maps in this report. Five study areas were selected within the analysis domain where more detailed cost analysis was conducted and cost parameters, such as annual energy production, capital cost expenditures (CapEx), operational cost expenditures (OpEx), and net capacity factors are reported. These five study areas include Morro Bay, Diablo Canyon, Humboldt, Cape Mendocino and Del Norte.

17 WIND ENERGY↗

Pilot microbial electrolysis cell closes the hydrogen loop for hydrothermal wet waste conversion to jet fuel

The global shift toward net-zero emissions necessitates resource recovery from wet waste. In this study, we demonstrate the first feasibility of combining pilot-scale microbial electrolytic cells (MECs) with hydrothermal liquefaction (HTL) for simultaneous post-hydrothermal liquefaction wastewater (PHW) treatment and efficient hydrogen (H₂) production to meet biocrude upgrading requirements. Long-term single reactor operation revealed that fixed anode potential enabled rapid startup, and low catholyte pH and high salinity were effective in suppression of cathodic methanogenesis and acetogenesis – resulting in high current density of 16.6 A m –2 and 9.3 A m –2 when feeding synthetic wastewater and PHW respectively. Additionally, the anode biofilm exhibited spatial variations in response to local environmental conditions. In conclusion, onsite parallel or serial operations of multiple MECs showed good performance using actual PHW with a record-high H 2 production rate of 0.5 L L R day –1 for MEC over 10 liters scale, and the optimal chemical oxygen demand (COD)-to-H 2 yield reached 0.127 kg-H 2 per kg-COD, supporting a self-sufficient, closed-loop upgrade to jet fuel.

08 HYDROGEN↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled CF{sub 4} plasmas

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this type of plasma source, ballistic electrons originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased electrode and are then accelerated in the sheath toward an opposite non-dc biased lower electrode. For electropositive (argon) plasmas it has been shown that the primary contribution of ballistic electrons is ionization in the dc sheath and modulation of the discharge properties. Whether applied dc power net increases or decreases the plasma electron density depends on the rf power environment of the opposing substrate electrode. When rf power is applied to a substrate electrode, the rf self-bias creates a potential well that traps the ballistic electrons, the result being that the electron density increases with dc power. In most cases the fraction of high energy electrons that reach the electrode is small. In this article, the authors describe the use of test particle Monte Carlo simulations to describe the behavior of hybrid dc/rf electronegative (CF{sub 4}) plasmas. In contrast to the behavior in argon, process experiments with electronegative gases such as CF{sub 4} indicate that the electron density is independent of dc bias power when no rf power is applied to the wafer. Test particle simulations show that CF{sub 4} provides for a 'self-confinement' effect caused by large cross sections for vibrational excitation at intermediate to low electron energies, which results in weak dependence of electron density on dc bias voltage when low frequency bias is not applied to the wafer. This emphasizes the important role of gas composition and cross-section structure in the control of dc/rf plasmas. Consistent with experiment, test particle Monte Carlo simulations also show that when rf is applied to the substrate, overall the CF{sub 4} plasma's macroscopic properties are similar manner to argon plasmas. Even so, differences between the argon and CF{sub 4} plasmas occur related to the scaling of the fraction of ballistic electrons that reach the wafer as a function of dc and rf power. A regime is identified in which CF{sub 4} and argon plasmas have the equivalent ratio of ballistic to thermal electron density adjacent to the surface. The authors explain that the differences are related to different thermalization and ionization mechanisms in these plasmas. In addition, they find the electron attachment constant is zero in the dc sheath and nearly constant value in the bulk as the transit time in the sheath is far less than the mean attachment time. The same simple function to express ionization rate constant as a function of electric field in the dc sheath, developed for argon, can be also applied to CF{sub 4}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TRIPOLI-4 criticality calculations for MOX fuelled SNEAK 7A and 7B fast critical assemblies

A prototype Generation IV fast neutron reactor is under design and development in France. The MOX fuel will be introduced into this self-generating core in order to demonstrate low net plutonium production. To support the TRIPOLI-4 Monte Carlo transport code in criticality calculations of fast reactors, the effective delayed neutron fraction {beta}eff estimation and the Probability Tables (PT) option to treat the unresolved resonance region of cross-sections are two essentials. In this study, TRIPOLI-4 calculations have been made using current nuclear data libraries JEFF-3.1.1 and ENDF/B-VII.0 to benchmark the reactor physics parameters of the MOX fuelled SNEAK 7A and 7B fast critical assemblies. TRIPOLI-4 calculated K{sub eff} and {beta}eff of the homogeneous R-Z models and the 3D multi-cell models have been validated against the measured ones. The impact of the PT option on K{sub eff} is 340 {+-} 10 pcm for SNEAK 7A core and 410 {+-} 12 pcm for 7B. Four-group spectra and energy spectral indices, f8/f5, f9/f5, and c8/f5 in the two SNEAK cores have also been calculated with the TRIPOLI-4 mesh tally. Calculated spectrum-hardening index f8/f5 is 0.0418 for SNEAK 7A and 0.0315 for 7B. From this study the SNEAK 3D models have been verified for the next revision of IRPhE (International Handbook of Evaluated Reactor Physics Benchmark Experiments). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capturing carbon dioxide from air with charged-sorbents

Emissions reduction and greenhouse gas removal from the atmosphere are both necessary to achieve net-zero emissions and limit climate change. There is thus a need for improved sorbents for the capture of carbon dioxide from the atmosphere, a process known as direct air capture. In particular, low-cost materials that can be regenerated at low temperatures would overcome the limitations of current technologies. In this work, we introduce a new class of designer sorbent materials known as ‘charged-sorbents’. These materials are prepared through a battery-like charging process that accumulates ions in the pores of low-cost activated carbons, with the inserted ions then serving as sites for carbon dioxide adsorption. We use our charging process to accumulate reactive hydroxide ions in the pores of a carbon electrode, and find that the resulting sorbent material can rapidly capture carbon dioxide from ambient air by means of (bi)carbonate formation. Unlike traditional bulk carbonates, charged-sorbent regeneration can be achieved at low temperatures (90–100 °C) and the sorbent’s conductive nature permits direct Joule heating regeneration using renewable electricity. Given their highly tailorable pore environments and low cost, we anticipate that charged-sorbents will find numerous potential applications in chemical separations, catalysis and beyond.

54 ENVIRONMENTAL SCIENCES↗

Kinetic Analysis of Competitive Electrocatalytic Pathways: New Insights into Hydrogen Production with Nickel Electrocatalysts

The hydrogen production electrocatalyst Ni(PPh2NPh2)22+ (1) is capable of traversing multiple electrocatalytic pathways. When using dimethylformamidium, DMF(H)+, the mechanism of formation of H2 catalyzed by 1 changes from an ECEC to an EECC mechanism as the potential approaches the Ni(I/0) couple. Two recent electrochemical methods, current-potential analysis and foot-of-the-wave analysis (FOWA), were performed on 1 to measure the detailed chemical kinetics of the competing ECEC and EECC pathways. A sensitivity analysis was performed on the electrochemical methods using digital simulations to gain a better understanding of their strengths and limitations. Notably, chemical rate constants were significantly underestimated when not accounting for electron transfer kinetics, even when electron transfer was fast enough to afford a reversible non-catalytic wave. The EECC pathway of 1 was found to be faster than the ECEC pathway under all conditions studied. Using buffered DMF: DMF(H)+ mixtures led to an increase in the catalytic rate constant (kobs) of the EECC pathway, but kobs for the ECEC pathway did not change when using buffered acid. Further kinetic analysis of the ECEC path revealed that added base increases the rate of isomerization of the exo-protonated Ni(0) isomers to the catalytically active endo-isomers, but decreases the net rate of protonation of Ni(I). FOWA on 1 did not provide accurate rate constants due to incomplete reduction of the exo-protonated Ni(I) intermediate at the foot of the wave, but FOWA could be used to estimate the reduction potential of this previously undetected intermediate. This research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.

electrocatalysis↗

Effects of Rangeland Evapotranspiration on Groundwater Recharge, Discharge, and Flow at the Tuba City, Arizona, Disposal Site - 17159

The US Department of Energy Office of Legacy Management is modeling groundwater flow and contaminant transport at a former uranium mill site near Tuba City, Arizona. A goal is to project groundwater travel times and flow volumes between the former mill site and Moenkopi Wash, a down-gradient stream. Aquifer recharge and discharge are sensitive model parameters; however, assigning representative rates is inexact and involves approximations. We applied a remote sensing algorithm to determine spatially variable evapotranspiration (ET), precipitation recharge, and groundwater discharge rates for use in a large scale groundwater flow model for the site. ET is the combination of evaporation and plant transpiration from soil and groundwater. We estimated landscape-scale ET over a 13-year period (2000 to 2012) for distinct plant communities within a 3531-hectare groundwater model domain (GMD), and then evaluated effects of ET on groundwater recharge and discharge within the GMD. Our empirical algorithm was derived from ground ET measurements, multispectral satellite imagery, and temperature data. Groundwater recharge or discharge rates were calculated for each plant community (or ET Zone) as the difference between precipitation (PPT) and ET rates. Recharge occurred in plant communities where PPT exceeded ET; discharge occurred where ET exceeded PPT. Estimates of groundwater recharge rates for upland plant communities that survive on meteoric water ranged from 0 to 88 mm yr{sup -1}. Estimates of groundwater discharge for phreatophyte plant communities ranged from 23 mm yr{sup -1} to 150 mm yr{sup -1}. Phreatophytes are plants that survive by extracting groundwater. Zero recharge occurred in plant communities where ET rates equaled annual average precipitation. An increase in groundwater recharge (PPT > ET) was associated with past land disturbances and heavy livestock grazing in upland areas. Groundwater discharge (ET > PPT) was highest in riparian phreatophyte communities, but lower than optimal in upland phreatophyte communities impacted by heavy grazing. Protecting phreatophyte communities from grazing at Tuba City could potentially increase ET from 153 mm yr{sup -1} to at least 500 mm yr{sup -1}. The validity of using the ET algorithm to estimate recharge and discharge was evaluated by comparing the net volumetric outflow rate for the model domain with base flow measurements collected from Moenkopi Wash. Modeled outflow approximated measured flow gains in the Wash, increasing our confidence in the ET algorithm and in the model. Results suggest that rangeland management practices that reduce groundwater recharge rates and increase groundwater discharge rates should be evaluated as part of an overall groundwater remediation strategy. (authors)

54 ENVIRONMENTAL SCIENCES↗

Global Carbon Budget 2025

Accurate assessment of anthropogenic carbon dioxide (CO 2 ) emissions and their redistribution among the atmosphere, ocean, and terrestrial biosphere in a changing climate is critical to better understand the global carbon cycle, support the development of climate policies, and project future climate change. Here we describe and synthesise datasets and methodologies to quantify the five major components of the global carbon budget and their uncertainties. Fossil CO 2 emissions (E FOS ) are based on energy and cement production data. Emissions from land-use change (E LUC ) are estimated by bookkeeping models based on land-use data. The global atmospheric CO 2 growth rate (G ATM ) is computed from changes in concentration measured at surface stations. The global net uptake of CO 2 by the ocean (S OCEAN ) is estimated with global ocean biogeochemistry models and observation-based fCO 2 -products. The global net uptake of CO 2 by the land (S LAND ) is estimated with dynamic global vegetation models. Additional lines of evidence are provided by atmospheric inversions, atmospheric oxygen measurements, ocean interior observation-based estimates, and Earth System Models. This year, we introduced corrections on the E LUC , S OCEAN and S LAND estimates. The sum of all sources and sinks results in the carbon budget imbalance (B IM ), a measure of imperfect data and incomplete understanding of the contemporary carbon cycle. All uncertainties are reported as ± 1σ. For the year 2024, E FOS increased by 1.1 % relative to 2023, with fossil emissions at 10.3 ± 0.5 GtC yr −1 (including the cement carbonation sink, 0.2 GtC yr −1 ), E LUC was 1.3 ± 0.7 GtC yr −1 , for total anthropogenic CO 2 emissions of 11.6 ± 0.9 GtC yr −1 (42.4 ± 3.2 GtCO2 yr −1 ). Also, for 2024, G ATM was 7.9 ± 0.2 GtC yr−1 (3.73 ± 0.1 ppm yr −1 ), 2.2 GtC above the 2023 growth rate. SOCEAN was 3.4 ± 0.4 GtC yr −1 and S LAND was 1.9 ± 1.1 GtC yr −1 , leaving a large negative B IM (−1.7 GtC yr −1 ), suggesting that the total sink or G ATM is strongly overestimated in 2024. The global atmospheric CO 2 concentration averaged over 2024 reached 422.8 ± 0.1 ppm. Preliminary data for 2025 suggest an increase in E FOS relative to 2024 of +1.0 % (0.2 % to 1.7 %) globally, and atmospheric CO 2 concentration increasing by 2.1 ppm reaching 425.6 ppm, 53 % above the pre-industrial level (around 278 ppm in 1750). Overall, the mean and trend in the components of the global carbon budget are consistently estimated over the period 1959–2024, with a near-zero overall budget imbalance, although discrepancies of up to around 1 GtC yr −1 persist for the representation of annual to decadal variability in CO 2 fluxes. Comparison of estimates from multiple approaches and observations shows: (1) a persistent large uncertainty in the estimate of land-use change emissions, (2) a low agreement between the different methods on the magnitude of the land CO 2 flux in the northern extra-tropics, and (3) a discrepancy between the different methods on the mean ocean sink. This living data update documents changes in methods and datasets applied to this most-recent global carbon budget as well as evolving community understanding of the global carbon cycle. The data presented in this work are available at https://doi.org/10.18160/GCP-2025 (Friedlingstein et al., 2025c).

54 ENVIRONMENTAL SCIENCES↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗

Investigation of Ga 2 O 3 as a new transparent conductive oxide for photovoltaics applications

This small innovation project intended to leverage recent activity and advances in ultrawide-bandgap oxide power electronics toward the investigation of Ga 2 O 3 as a transparent conductive oxide (TCO) for use in photovoltaics (PV). Ga 2 O 3 ’s theoretical advantage over incumbent TCOs is its very large bandgap of 4.8 eV, ensuring optical transparency of photons with λ ≥ 260 nm, effectively the full terrestrial solar spectrum. At the time of proposal writing, literature on Ga 2 O 3 as a TCO/optical material was relatively sparse — what little existed was focused on for UV sensors and/or emitters, with none related to PV. As such, this project was intended to help determine the potential of Ga 2 O 3 as a PV-oriented TCO by investigating its deposition using tools common to the PV and electronics industries — atomic layer deposition (ALD) and RF sputtering (RS), both of which are already used in PV manufacturing — and its resultant optical and electronic properties. Final project goals were to test its application to Si and III-V solar cells. Controllable film thickness and excellent uniformity was established for both methods deposition methods, with ALD providing higher precision for thinner films and RS more effective for growing thicker films. The as-deposited films were found to be amorphous in nature. Spectroscopic ellipsometry (SE) confirmed bandgaps of at least 4.8 eV and non-parasitic absorption across both AM0 and AM1.5G spectra; a refractive index approaching the expected value of 1.8 was also observed, with some degree of tunability based on process parameters. Using this initial optical data, a transfer matrix model, which interfaces with in-house EQE and LIV models, was developed to simulate Ga 2 O 3 optical effects on various solar cells, included potential in antireflection coatings (ARCs). Despite promising optical properties, the resultant resistivity / conductivity metrics did not meet expectations, regardless of deposition process. Although thick RS-deposited films, using both undoped and 1 at% Ge (n-type) doped sintered targets — demonstrated high net carrier concentrations (via C-V), and low specific resistance Ohmic contacts were demonstrated, transmission line measurements (TLM) showed very high resistivity. Further analysis indicated high vertical film conductivity, but very low lateral conductivity. Deeper characterization revealed a relatively high density of nano/microcrystalline inclusions that were ostensibly the source of the vertical conductivity, with the amorphous matrix serving as an effective insulator (likely due to high concentrations of electronic trap states). Despite extensive work to increase film polycrystallinity — demonstrated via high temperature annealing — sufficient lateral conductivity for TCO use was not achieved. The final phase of the project shifted focus toward investigation of ALD-deposited Ga 2 O 3 ’s potential as a passivant and/or passivating contact for both Si and III-V solar cells, with expectation of performance similar to Al 2 O 3 . However, initial rounds of testing using our baseline ALD process yielded minimal (but not quite zero) passivation of both GaInP and Si surfaces. Dielectric passivation is well-known to be highly process sensitive; given the unoptimized nature of the process used, this work was deemed inconclusive. The final outlook with respect to feasibility of Ga 2 O 3 as a PV-oriented TCO is, ultimately, still uncertain. The work performed in this project confirmed the optical properties and deposition methods, but the achieved electrical properties do not meet technological needs; literature reports in recent years are somewhat inconsistent and potentially untrustworthy, but generally appear to be in line with our results. At the very least it is clear that, should Ga 2 O 3 still be under consideration for PV TCO and/or selective contact applications, a significant amount of optimization and study is still needed.

14 SOLAR ENERGY↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Solvent-Free Dimerization of Isoprene at Ambient Temperature: A Green Route to Biofuel-Range Hydrocarbons

In order to achieve a net-zero carbon footprint by 2050, the global aviation industry must reduce its dependence on fossil fuels. In this regard, there is a global challenge to produce sufficient sustainable aviation fuel (SAF) from renewable sources. Isoprene is an intermediate molecule that can be derived from multiple biomass-based or biosynthetic routes. Here, in this work, we report a green route for the catalytic conversion of isoprene to hydrocarbons that are suitable for aviation fuel. By using an Amberlyst-15 catalyst without metal loading at ambient temperature (19–23 °C), as well as 40 °C, 50 °C, and 60 °C, isoprene was converted into olefinic precursors for SAF and/or blending with conventional aviation fuels. Specifically, at ambient temperature, the process achieved approximately 70 wt % conversion of isoprene with over 50 mol % carbon selectivity toward the aviation fuel range. The resulting SAF-range hydrocarbons were composed of iso-alkenes, branched olefinic monocyclic compounds, and bicyclic compounds, covering a wide range of aviation fuel components. Our work demonstrates, for the first time, the formation of diverse hydrocarbon families for SAF and/or aviation fuel blending at ambient temperature from isoprene.

09 BIOMASS FUELS↗

Stability and variations of plasma parameters in the L-2M stellarator during excitation of the induction current in the regime of ECR plasma heating

Results are presented from experimental studies of variations in the plasma parameters during the excitation of a multiaxis magnetic configuration by the induction current (up to 17 kA) in the basic magnetic configuration of the L-2M stellarator in the regime of ECR heating at a microwave power of {approx}200 kW ({approx}1 MW m{sup -3}) and an average plasma density of (1-2) x 10{sup 19} m{sup -3}. The current direction was chosen to reduce the net rotational transform (the so-called 'negative' current). The current was high enough for the rotational transform to change its sign inside the plasma column. Computer simulations of the L-2M magnetic structure showed that the surface with a zero rotational transform is topologically unstable and gives rise to magnetic islands, i.e., to a multiaxis magnetic configuration. Magnetic measurements showed that, at negative currents above 10 kA, intense bursts of MHD oscillations with a clearly defined toroidal mode number n = 0 were observed in the frequency range of several kilohertz. Unfortunately, the experimental data are insufficient to draw the final conclusion on the transverse structure of these oscillations. The radial temperature profiles along the stellarator major radius in the equatorial plane were studied. It is found that the electron temperature decreases by a factor of 1.3 in the plasma core (r/a {<=} 0.6) and that the temperature jump is retained near the boundary. A change in turbulent fluctuations of the plasma density during the excitation of a negative current was studied using wave scattering diagnostics. It is found that the probability density function of the increments of fluctuations in the plasma core differs from a Gaussian distribution. The measured distribution is heavy-tailed and broadens in the presence of the current. It is found that the spectrum of turbulent fluctuations and their Doppler shift near the plasma boundary are nonuniform in the radial direction. This may be attributed to the shear of the poloidal velocity. The experimental results indicate that the formation of regions with a zero rotational transform in the plasma core somewhat intensifies plasma transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benefits of Integration of Aerojet Rocketdyne and RTI Advanced Gasification Technologies for Hydrogen-Rich Syngas Production

The key objective for this project was to evaluate the potential to achieve substantial reductions in the production cost of H 2 -rich syngas via coal gasification with near-zero emissions due to the cumulative and synergistic benefits realized when multiple advanced technologies are integrated into the overall conversion process. In this project, Aerojet Rocketdyne’s (AR’s) advanced gasification technology (currently being offered as R-GAS™) and RTI International’s (RTI’s) advanced warm syngas cleanup technologies were evaluated via a number of comparative techno-economic case studies. AR’s advanced gasification technology consists of a dry solids pump and a compact gasifier system. Based on the unique design of this gasifier, it has been shown to reduce the capital cost of the gasification block by between 40 and 50%. At the start of this project, actual experimental work had been demonstrated through pilot plant systems for both the gasifier and dry solids pump. RTI’s advanced warm syngas cleanup technologies consist primarily of RTI’s Warm Gas Desulfurization Process (WDP) technology, which effectively allows decoupling of the sulfur and CO 2 removal allowing for more flexibility in the selection of the CO 2 removal technology, plus associated advanced technologies for direct sulfur recovery and water gas shift (WGS). WDP has been demonstrated at pre-commercial scale using an activated amine carbon dioxide recovery process which would not have been possible if a majority of the sulfur had not been removed from the syngas by WDP. This pre-commercial demonstration of RTI’s advanced warm syngas cleanup system was conducted in parallel to the activities on this project. The technical data and cost information from this pre-commercial demonstration were extensively used in this project during the techno-economic analysis. With this project, both of RTI’s advanced WGS technologies were investigated. Because RT’s advanced fixed-bed WGS (AFWGS) process was successfully implemented in the WDP pre-commercial demonstration test mentioned above, this technology was used as part of RTI’s advanced warm syngas technology package for the techno-economic analyses for this project. RTI’s advanced transport-reactor-based WGS (ATWGS) process was still conceptual at the start of this project, but one of the tasks for this project was to evaluate the technical feasibility of this technology. In each of the three application-based comparison studies conducted as part of this project, the reference case was based on an existing Department of Energy National Energy Technology Laboratory (DOE/NETL) system study. Each of these references cases used existing commercial technology and the system resulted in > 90% carbon capture. In the comparison studies for the use of the hydrogen-rich syngas generated in either an Integrated Gasification Combined Cycle (IGCC) or a Coal-to-Methanol (CTM) plant, the comparison cases consisted of the reference case, a case with the integration of each individual advanced technology (either AR or RTI), and finally a case with the integration of all the advanced technologies (AR and RTI combined). In the Coal-to-Liquids (CTL) comparison study, the comparison study consisted of only three cases, which included a reference case, a case with just RTI’s advanced syngas cleaning technology, and a case with AR’s and RTI’s advanced technologies. The results from these comparison studies showed that the integration of the advanced technologies did result in substantial benefits, and by far the greatest benefits were achieved for cases integrating all the advanced technologies. For the IGCC study, the fully integrated case resulted in a 1.4% net efficiency improvement, an 18% reduction in capital cost per kW of capacity, a 12% reduction in the operating cost per kWh, and a 75–79% reduction in sulfur emissions. For the CTM case, the fully integrated plant resulted in a 22% reduction in capital cost, a 13% reduction in operating costs, a > 99% net reduction in sulfur emissions, and a reduction of 13–15% in CO 2 emissions. Because the capital cost represents over 60% of the methanol Required Selling Price (RSP), the significant reduction in the capital cost for the advanced technology case resulted in an 18% reduction in methanol RSP. For the CTL case, the fully integrated plant resulted in a 16% reduction in capital cost, which represented a 13% reduction in diesel RSP. Finally, the technical feasibility analysis of RTI’s ATWGS process demonstrated that a fluid-bed catalyst with sufficient attrition resistance and WGS activity could be made and that the process achieved about a 24% reduction in capital cost compared to a conventional fixed-bed commercial process.

08 HYDROGEN↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Project 57 Air Monitoring Report: January 1 through December 31, 2017

On April 24, 1957, the Atomic Energy Commission (AEC) (now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley northeast of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a non-nuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and in 2007, the DOE expanded the demarked Contamination Area (CA) by posting signs 200 to 400 ft (60 to 120 m) outside of the original fence. Plutonium in soil attaches preferentially to smaller particles (Tamura, 1985; Friesen, 1992; Murarik et al., 1992; and Misra et al., 1993). Therefore, redistribution of soil particles by wind (dust) and water are the mechanisms most likely to transport plutonium beyond the boundary of the Project 57 CA. Monitoring was implemented in 2011 by Desert Research Institute (DRI) to determine if radionuclide contamination was detectable in samples of airborne dust and to characterize meteorological and environmental parameters that influence dust transport. Initially, two monitoring stations consisting of radiological, meteorological, and dust sampling equipment were installed near the southeast and northeast corners of the CA. In January 2015, the original monitoring stations were dismantled and moved farther to the west along the CA boundary. This move was made to place the monitoring stations downwind of ground zero and the High Contamination Area (HCA) during the dominant northerly and southerly winds. Samples of particles suspended in the air are collected every two weeks and submitted for laboratory assessments of gross alpha and gross beta radioactivity, and for determinations of gamma-emitting radionuclides. In calendar year (CY) 2017, the mean gross alpha concentration at monitoring station P57-4 was approximately 4.25 times the value at monitoring station P57-3. In CY2015 and CY2016, the difference in mean gross alpha concentration at the two stations was approximately 1.5. The mean gross alpha concentrations at P57-3 and P57-4 were approximately 1.9 and 7.9 times, respectively, the mean gross alpha concentrations at the surrounding Community Environmental Monitoring Program (CEMP) stations. The minimum gross alpha concentrations reported for the Project 57 stations are in the range of the minimum values observed at the CEMP stations. However, maximum gross alpha concentrations are greater than the maximum concentrations observed at the surrounding CEMP stations. Gamma spectroscopy analyses resulted in the detection of seven radionuclides. Except for americium-241 (Am-241), all reported radionuclides occur naturally in the environment. The Am-241 detection by gamma spectroscopy was confirmed by alpha spectroscopy. During each quarter of CY2017, four suspended particulate matter samples were selected for alpha spectroscopy analysis. Two were selected each quarter from the regular biweekly samples collected at each of the two monitoring stations. Of the eight samples from P57-3, one was reported to have plutonium-238 (Pu-238) above the minimum detectable activity (MDA) and five were reported to have plutonium 239/240 (Pu-239/240) above the MDA. Of the eight samples from P57-4, three were reported to have Pu-238 above the MDA and six were reported to have Pu-239/240 above the MDA. Soil material is also transported by saltation, which is a wind driven phenomena that bounces sand-sized soil particles across the land surface because they are too heavy to be suspended in the air. Samples of particles transported by saltation were collected downwind and upwind of the CA at both monitoring stations in May 2017 after a 190-day deployment and again in September 2017 after a 114-day deployment. Mass of the saltation samples was determined after oven drying. The September sample had greater mass than the May sample. The same relationship was observed for the suspended particulate matter samples during periods of saltation sample collection. The difference in the collected mass appears to be because of the amount of soil moisture. Higher soil moisture exerts additional isotopic bonds between soil particles and water molecules, and between water molecules that envelop soil particles, making it more difficult for wind to raise the particles as dust. In general, samples collected from saltation traps facing south contained more material than samples collected from traps facing north. This suggests that although saltation material may have been moving back and forth in conjunction with the two dominant wind directions, there was a net trend for saltation material to be transported toward the north. Radiological analyses of the saltation samples show that the smaller particle size faction (<63 μm) generally produced the highest activity levels of Am-241, Pu-238, and Pu-239/240. In general, the isotope activity levels decreased as the particle size increased. These results are consistent with the expectation that the greatest potential for transport of radiological contamination is with the smaller particles. Thermoluminescent dosimeters (TLDs) indicated that the average annual external radioactivity dose at the monitoring stations is slightly higher than the dose determined at the surrounding CEMP stations, but approximately half of the estimated national average dose received by the general public from exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 CA. Winds in excess of approximately 15 mph (24 km/hr) begin to generate dust movement by saltation or suspension, as determined by the monitoring instruments. Saltated particles, PM10 (i.e., inhalable dust), and PM2.5 (i.e., fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occurred for winds exceeding 20 mph (32 km/hr). When the wind/dust analysis was performed for winds separated into the dominant northerly and southerly wind directions, it was evident that the northerly winds generated the higher PM10 concentrations and had the dominate influence on the PM10 concentration determined for all wind speeds when all wind directions were evaluated together. During the year, winds in excess of 20 mph (32 km/hr) occurred approximately one percent of the time. Although winds sufficient to generate dust occur at the Project 57 site, they are infrequent and of short duration. A preliminary assessment of individual wind events suggests that dust generation in response to specific wind conditions is highly variable. Wind speeds that would be expected to generate noticeable dust may not do so in every instance. Additionally, saltation transport in response to wind conditions was less common than expected. These variations were likely because of the influence of meteorological and environmental parameters other than wind.

54 ENVIRONMENTAL SCIENCES↗