Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Magnetic order in the two-dimensional metal-organic framework manganese pyrazinecarboxylate with Mn-Mn dimers

The magnetic properties of [Mn(pyrazinecarboxylate) 2 ] n , empirical formula C 10 H 6 MnN 4 O 4 , are investigated through susceptibility, heat capacity, and neutron scattering measurements. The structure consists of Mn-Mn dimers linked on a distorted 2D hexagonal structure. The weak out-of-plane interactions create a quasi-2D magnetic material within the larger three-dimensional metal-organic framework structure. Here, we show that this material undergoes a two-stage magnetic transition, related to the low dimensionality of the Mn lattice. First, at 5 K, which is assigned to the initial development of short-range order in the 2D layers. This is followed by long-range order at 3.3 K. Applied field measurements reveal the potential to induce magnetic transitions in moderately small fields of ~2 T. Neutron powder diffraction enabled the determination of a unique magnetic space group P2 1 '/c (No. 14.77) at 1.5 K. This magnetic structure consists of antiferromagnetically coupled Mn-Mn dimers with spins principally along the out-of-plane $a$ axis.

36 MATERIALS SCIENCE↗

Spin dynamics and a nearly continuous magnetic phase transition in an entropy-stabilized oxide antiferromagnet

In this work, the magnetic order and the spin dynamics in the antiferromagnetic entropy-stabilized oxide (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O (MgO-ESO) have been studied using muon spin relaxation (μSR) and inelastic neutron scattering. We find that antiferromagnetic order develops gradually in the sample volume as it is cooled below 140 K, becoming fully ordered around 100 K. The spin dynamics show a critical slowing down in the vicinity of the transition, and the magnetic order parameter grows continuously in the ordered state. These results indicate that the antiferromagnetic transition is continuous but proceeds with a Gaussian distribution of ordering temperatures. Additionally, the magnetic contribution to the specific heat determined from inelastic neutron scattering likewise shows a broad feature centered around 120 K. High-resolution inelastic neutron scattering further reveals an initially gapped spectrum at low temperature which sees an increase in a quasielastic contribution upon heating until the ordering temperature.

36 MATERIALS SCIENCE↗

Using ISS Telescopes for Electromagnetic Follow-up of Gravitational Wave Detections of NS-NS and NS-BH Mergers

The International Space Station offers a unique platform for rapid and inexpensive deployment of space telescopes. A scientific opportunity of great potential later this decade is the use of telescopes for the electromagnetic follow-up of ground-based gravitational wave detections of neutron star and black hole mergers. We describe this possibility for OpTIIX, an ISS technology demonstration of a 1.5 m diffraction limited optical telescope assembled in space, and ISS-Lobster, a wide-field imaging X-ray telescope now under study as a potential NASA mission. Both telescopes will be mounted on pointing platforms, allowing rapid positioning to the source of a gravitational wave event. Electromagnetic follow-up rates of several per year appear likely, offering a wealth of complementary science on the mergers of black holes and neutron stars.

NS-NS and NS-BH mergers↗

Characterization of different forms of Zr-2.5Nb samples before and after neutron irradiation

Deleterious effects of hydride precipitation on the mechanical properties of Zr-based alloy systems have been studied for many years. Most of these studies have been conducted at high-temperature irradiation conditions that are compatible with those in commercial reactor systems, such as light water and pressurized water reactors. Evaluations of hydride effects on the mechanical properties of welded Zr-2.5Nb are sparse among these reported studies. Research on the mechanical properties of Zr-based alloys neutron irradiated at low temperatures (<100 °C) is also very rare in the literature. Since some companies are interested in using Zr-based alloys as structural materials and in other parts such as pressure tubes in small reactor systems, low-temperature irradiation studies of these materials are important. The current work presents an evaluation of the tensile properties of Zr-2.5Nb welded using tungsten inert gas and electron beam welding as a function of hydrogen charging and neutron irradiation at low temperatures (60–100 °C).

36 MATERIALS SCIENCE↗

U.S. Electronic Neutron Generator Use in Research and Academia – A Survey [Slides]

This is a slide deck intended for use at the upcoming IAEA workshop "EVT2002488 Consultancy Meeting on Industrial Applications of Nucleonic Control Systems based on Neutrons from sealed sources and generators". This slide deck provides a survey of U.S. commercial neutron generator technology, including manufacturers, and a few examples of use in academia, and some prior research at INL. All data and figures in this presentation are either publicly available (note citations) or are INL materials that have been previously release through STISM for public presentations or papers.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Correlated fission data measurements with DANCE and NEUANCE

To enhance the capabilities of the DANCE array, a new detector array NEUANCE was developed to enable simultaneous measurements of prompt fission neutrons and γ rays. NEUANCE was designed and constructed using 21 stilbene organic scintillator crystals. It was installed in the central cavity of the DANCE array. Signals from the 160 BaF 2 detectors of DANCE and the 21 detectors of NEUANCE were merged into a newly designed high-density high-throughput data acquisition system. The excellent pulse shape discrimination properties of stilbene enabled detection of neutrons with energy thresholds as low as 30–40 keVee. A fission reaction tagging method was developed using a NEUANCE γ-ray or neutron signal. The probability of detecting a neutron from the spontaneous fission of 252 Cf using NEUANCE is 47%. New correlated data for prompt fission neutrons and prompt fission rays were obtained for 252 Cf using this high detection efficiency experimental setup. In conclusion, average properties of prompt fission neutron emission as a function of prompt fission γ-ray quantities were also obtained, suggesting that neutron and γ-ray emission in fission are correlated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precipitation of α' in neutron irradiated commercial FeCrAl alloys

In this paper, Alkrothal 720 and Kanthal APMT™, two commercial FeCrAl alloys, were neutron irradiated up to damage doses of 7.0 displacements per atom (dpa) in the temperature range of 320 to 382 °C to characterize the α' precipitation in these alloys using small-angle neutron scattering. Both alloys exhibited α' precipitation. Kanthal APMT™ exhibited higher number densities and volume fraction, a result attributed to its higher Cr content compared with Alkrothal 720. Finally, trends observed as a function of damage dose (dpa) are consistent with literature trends for both FeCr and FeCrAl alloys

36 MATERIALS SCIENCE↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗

Evolution of noncollinear magnetism in magnetocaloric MnPtGa

MnPtGa crystallizes in the hexagonal Ni 2 In structure type in space group P6 3 /mmc and has been reported to display a ferromagnetic Curie temperature near 220K. Here we find a transition near T c = 236 K to a ferromagnetic state, albeit with a reduced moment from what is expected for collinear ordering. The peak magnetocaloric entropy change was determined to be ΔS M = –1.9 J kg –1 K –1 for an applied magnetic field of H = 5 T at the ferromagnetic ordering temperature. Magnetostructural coupling manifests as a change in the slope of the thermal expansion coefficients of the c lattice parameter near T c , with a negative spontaneous volume magnetostriction; ω = –300 ppm at 190K. In this work, neutron powder diffraction studies of the magnetic ground state reveal an evolution in complexity as temperature decreases: from a ferromagnet, to a canted antiferromagnet, to the eventual formation of a spin-density-wave state at low temperatures.

36 MATERIALS SCIENCE↗

Aberration corrected RF flipper for high resolution neutron spectroscopy

Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.

36 MATERIALS SCIENCE↗

Modulated crystal structures of phases VII and V in (NH{sub 4}){sub 3}H(SO{sub 4}){sub 2}. Neutron Laue diffraction

A study of the crystal structure of the phases VII and V of (NH{sub 4}){sub 3}H(SO{sub 4}){sub 2} by mean of neutron Laue diffraction was carried out at temperatures from 5 to 300 K. It is found that the crystal structures of phases VII and V are incommensurately modulated with different periods, and that the phase transition from phase VII to phase V is of first order.

36 MATERIALS SCIENCE↗

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated-xylene (xylene-d 10 ; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. x 3 in. deuterated-xylene organic liquid scintillator (C 8 D 10 ; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C 6 D 6 ; NE230, BC537, and E1315) this scintillator can provide good pulse shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene -based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition E1301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light -response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective ( x 10 to x 100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. Here, as we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse -selected beam (as needed for time-of-flight) is not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical structure and curing dynamics of bisphenol S, PEEK™-like, and resveratrol phthalonitrile thermoset resins

This effort provides a multifaceted analysis of the structural changes and material dynamics of thermally driven softening and curing of three distinct phthalonitrile (PN) resins that cross-link into thermally stable and oxidation-resistant thermosets. Although this material system has yielded a large subset of fire-retardant composites that require facile processing and low-temperature curing, to date, insufficient information had been available on the fundamental processes that drive their softening and curing stages. Our approach conducted a complementary analysis the chemistry, monomer mobility, and rheology of three PN polymers in order to correlate the curing processes with corresponding structural and behavioral transformations of thermosets. Here, we focused on PNs with a bisphenol S backbone, a bisphenol A (PEEK™-like) backbone, and a resveratrol backbone. We relied on quasi-elastic neutron scattering (QENS) in order to analyze the in situ dynamics and self-diffusion properties of PN monomers, and to track changes in their mobilities during cross-linking and staging. Our analysis facilitates proper control over the staging and final curing of these resins and enables more efficient processing of these thermosets.

36 MATERIALS SCIENCE↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗