Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An unmet clinical need: The history of thrombus imaging

Robust thrombus imaging is an unresolved clinical unmet need dating back to the mid 1970s. While early molecular imaging approaches began with nuclear SPECT imaging, contrast agents for virtually all biomedical imaging modalities have been demonstrated in vivo with unique strengths and common weaknesses. Two primary molecular imaging targets have been pursued for thrombus imaging: platelets and fibrin. Some common issues noted over 40 years ago persist today. Acute thrombus is readily imaged with all probes and modalities, but aged thrombus remains a challenge. Similarly, anti-coagulation continues to interfere with and often negate thrombus imaging efficacy, but heparin is clinically required in patients suspected of pulmonary embolism, deep venous thrombosis or coronary ruptured plaque prior to confirmatory diagnostic studies have been executed and interpreted. These fundamental issues can be overcome, but an innovative departure from the prior approaches will be needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Leveraging latest computer science tools to advance nuclear cardiology

Nuclear cardiology has unique advantages compared to other modalities, since the image analysis is already much more automated compared to what is currently clinically performed for CT, MR, or echocardiography imaging. The diverse image and clinical data available to assess coronary disease function, perfusion, flow, and associated CT data provide new opportunities, but logistically these additional assessments increase the overall complexity of SPECT/PET reporting, necessitating additional expertise and time. The advances in artificial intelligence software can be leveraged to obtain comprehensive risk predictions and diagnoses from all available data. They will allow nuclear cardiology to retain competitive edge compared to other modalities and improve its overall clinical utility. These tools will enhance diagnosis and risk prediction beyond what is possible by subjective visual analysis and mental integration of data by physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PET/CT and Bone Scintigraphy: Metabolic Results in Musculoskeletal Lesions

Purpose: This review aimed to provide an overview on findings from metabolic imaging modalities such as bone scintigraphy and positron emission tomography–computed tomography (PET/CT) in musculoskeletal lesions. It is conceivable that methods assessing metabolism of bone tumors, combined with the morphological assessment, could enhance the possibility for a personalized therapy with particular emphasis to malignant neoplasms. Recent Findings: The assessment of bone tumors by conventional scintigaphic and morphological imaging has been recently integrated with the morpho-metabolic appraisal obtained by PET/CT systems. Increasing availability of this diagnostic modality has been shown to stratify properly the patients and the findings correlate well with outcome. Moreover, new tracers are being implemented in the study of musculoskeletal lesions by PET/CT while the new volumetric parameters used to identify the lesions hold great promise. Summary: Results from PET/CT are associated with tumor grading and histopathology in bone malignant lesions and they could be of value for implementing treatment strategy. Additionally, the metabolic assessment has been demonstrated useful for predicting surgical response and patients’ outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Lumbar Spondylolysis in Athletes: Role of Imaging

Purpose of review: Spondylolysis is a broad term, with advances in imaging enabling more accurate diagnosis of the activity and severity of a lesion. This review discusses the role of different imaging modalities in the diagnosis and management of lumbar spondylolysis in athletes. Recent Findings: Magnetic resonance imaging (MRI) has diagnostic and practical advantages over other imaging modalities and is particularly useful for detecting early stages of bone stress, including pre-symptomatic screening for active lumbar bone stress injuries. Whilst computed tomography remains the best imaging technique to visualise cortical breaches, specialised MRI sequences offer a viable alternative to detect active bone stress and chronic non-united defects. Summary: Imaging provides important information for the clinical management of athletes with lumbar spondylolysis. Roles for imaging, in particular MRI, include: (a) proactive screening and early detection, (b) diagnosis of a symptomatic lesion and (c) monitor healing and readiness to return to sport.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AFRL Additive Manufacturing Modeling Series: Challenge 4, In Situ Mechanical Test of an IN625 Sample with Concurrent High-Energy Diffraction Microscopy Characterization

In this work, we describe 3D characterization of an additively manufactured Inconel 625 nickel-base superalloy specimen conducted during a uniaxial tension test using a suite of nondestructive x-ray techniques. High-energy diffraction microscopy in both near- and far-field modalities are employed in situ to track evolution of the material orientation and stress–strain fields at six points during the mechanical test, and these data streams are registered with micro-computed tomography reconstructions which probe the material density. This data volume was matched to a multi-modal serial sectioning characterization of the specimen taken after loading, described in this article’s companion. Twenty-eight grains which were monitored throughout the experiment were selected to form the basis for AFRL AM Modeling Series Challenge 4, Microscale Structure-to-Properties.

36 MATERIALS SCIENCE↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

Nanomedicine for the molecular diagnosis of cardiovascular pathologies

Predicting acute clinical events caused by atherosclerotic plaque rupture remains a clinical challenge. Anatomic mapping of the vascular tree provided by standard imaging technologies is not always sufficient for a robust diagnosis. Yet biological mechanisms leading to unstable plaques have been identified and corresponding biomarkers have been described. Nanosystems charged with contrast agents and targeted towards these specific biomarkers have been developed for several types of imaging modalities. The first systems that have reached the clinic are ultrasmall superparamagnetic iron oxides for Magnetic Resonance Imaging. Their potential relies on their passive accumulation by predominant physiological mechanisms in rupture-prone plaques. Active targeting strategies are under development to improve their specificity and set up other types of nanoplatforms. Preclinical results show a huge potential of nanomedicine for cardiovascular diagnosis, as long as the safety of these nanosystems in the body is studied in depth. - Highlights: • Ischemic stroke and myocardial infarction are the main causes of death in the world. • Their prevalence is related to late detection of high-risk atherosclerotic plaques. • Biomarkers of atherosclerosis evolution and potential ligands have been identified. • Nanosystems based on these ligands appear promising for early molecular diagnosis. • Preclinical and clinical nanosystems for common imaging modalities are described.

60 APPLIED LIFE SCIENCES↗

Construction of EMSC-islet co-localizing composites for xenogeneic porcine islet transplantation

Highlights: • Endothelial-like mesenchymal stem cells (EMSC) are differentiated from MSCs. • EMSC-islet co-localizing composites may be an effective islet delivery modality. • EMSC-islet composites reduce the fragmentation of porcine islets. • EMSC-islet composites enhance the vascularization potential in vitro and in vivo. Pancreatic islet transplantation is an ultimate solution for treating patients with type 1 diabetes (T1D). The pig is an ideal donor of islets for replacing scarce human islets. Besides immunological hurdles, non-immunological hurdles including fragmentation and delayed engraftment of porcine islets need solutions to succeed in porcine islet xenotransplantation. In this study, we suggest a simple but effective modality, a cell/islet co-localizing composite, to overcome these challenges. Endothelial-like mesenchymal stem cells (EMSCs), differentiated from bone-marrow derived mouse mesenchymal stem cells (MSCs), and MSCs evenly coated the surface of porcine islets (>85%) through optimized culture conditions. Both MSCs and EMSCs significantly reduced the fragmentation of porcine islets and increased the islet masses, designated as islet equivalents (IEQs). In fibrin in vitro and in vivo angiogenesis analysis, constructed EMSC-islet composites showed higher angiogenic potentials than naked islets, MSC-islet composites, or human endothelial cell-islet composites. This novel delivery method of porcine islets may have beneficial effects on the engraftment of transplanted islets by prevention of fragmentation and enhancement of revascularization.

60 APPLIED LIFE SCIENCES↗

Simulation of dynamic crystal plasticity with a Lagrangian discontinuous Galerkin hydrodynamic method

Here we present a new Lagrangian modal discontinuous Galerkin (DG) hydrodynamic method that supports a dynamic dislocation based crystal plasticity model for simulating the mechanical behavior of crystallographic materials, both single crystal and polycrystalline, under dynamic conditions. A modal DG approach is used to evolve fields relevant to conservation laws. These fields are approximated by Taylor series polynomials of varying degree. These polynomials describe macro-scale hydrodynamic behavior while their evolution is determined by evaluating the dynamic crystal plasticity model at material points within the element. The dynamic crystal plasticity model is sensitive to the time increment size, with too large of time increments leading to instability in the model. To mitigate this, the temporal evolution of the dynamic crystal plasticity model is achieved with the combination of a sub-incrementing scheme with Heun’s third-order time integration scheme, which is also used to temporally evolve the governing equations. The implementation of the dynamic crystal plasticity model within the DG framework is tested using a 2D approximation of the Taylor impact test with a single crystal material, using quadratic elements that have faces that can bend. In addition to the standard continuous material modeling, we propose a new simulation method that would represent the heterogeneous behavior of polycrystalline microstructures within an element by varying the position and material properties of the material points within the element. This method is demonstrated using random orientation distributions on materials points that are arranged in both structured and random configurations.

42 ENGINEERING↗

An artificial neural network framework for reduced order modeling of transient flows

Here, this paper proposes a supervised machine learning framework for the non-intrusive model order reduction of unsteady fluid flows to provide accurate predictions of non-stationary state variables when the control parameter values vary. Our approach utilizes a training process from full-order scale direct numerical simulation data projected on proper orthogonal decomposition (POD) modes to achieve an artificial neural network (ANN) model with reduced memory requirements. This data-driven ANN framework allows for a nonlinear time evolution of the modal coefficients without performing a Galerkin projection. Our POD-ANN framework can thus be considered an equation-free approach for latent space dynamics evolution of nonlinear transient systems and can be applied to a wide range of physical and engineering applications. Within this framework we introduce two architectures, namely sequential network (SN) and residual network (RN), to train the trajectory of modal coefficients. We perform a systematic analysis of the performance of the proposed reduced order modeling approaches on prediction of a nonlinear wave-propagation problem governed by the viscous Burgers equation, a simplified prototype setting for transient flows. We find that the POD-ANN-RN yields stable and accurate results for test problems assessed both within inside and outside of the database range and performs significantly better than the standard intrusive Galerkin projection model. Finally, our results show that the proposed framework provides a non-intrusive alternative to the evolution of transient physics in a POD basis spanned space, and can be used as a robust predictive model order reduction tool for nonlinear dynamical systems.

42 ENGINEERING↗

Dynamics of coupled thermoacoustic modes: Noise and frequency spacing effects

Practical combustion systems consist of multiple thermoacoustic modes that are linearly stable or unstable at a wide range of frequencies. When coupled, the modal interactions are a strong function of the frequency spacing between them – having very significant implications on interpretation of linear stability or instability of modes from experimental data. Frequency spacing between the modes particularly influences the stability and existence of potential limit cycle solutions. In this paper, we extend earlier deterministic studies to include the effects of noise, studying how deterministic dynamics change with the addition of noise and the simultaneous impact of frequency spacing (i.e., closely, or widely spaced). Specifically, this paper characterizes three key effects of noise, which are (1) distribution of limit cycle amplitudes (“diffusion”), (2) shift in the average limit cycle amplitudes (“noise induced drift”), and (3) introduction of new bifurcations that are not present in the deterministic system. Key conclusions from this work are that in highly noisy practical environments, a deterministic/ low noise analysis will not be sufficient to explain even critical qualitative features of the system – such as existence of stable limit cycles or their amplitudes. Furthermore, the nature of noise-induced effects on nonlinear modal interactions can be fundamentally different for degenerate, closely spaced, and widely spaced modes.

42 ENGINEERING↗

Mediated electrochemistry for redox-based biological targeting: entangling sensing and actuation for maximizing information transfer

Biology and electronics are both expert at receiving, analyzing, and responding to information, yet they use entirely different information processing paradigms. Biology processes information using networks that are intrinsically molecular while electronics process information through circuits that control the flow of electrons. There is great interest in coupling the molecular logic of biology with the electronic logic of technology, and we suggest that redox (reduction-oxidation) is a uniquely-suited modality for interfacing biology with electronics. Specifically, redox is a native biological modality and is accessible to electronics through electrodes. Here, we summarize recent advances in mediated electrochemistry to direct information transfer into biological systems intentionally altering function, exposing it for more advanced interpretation, which can dramatically expand the biotechnological toolbox.

59 BASIC BIOLOGICAL SCIENCES↗

Children, medical radiation and the environment: An important dialogue

There are unique considerations in the medical care of children, which includes the use of medical imaging. Medical imaging is frequently necessary and is essential in diagnosis and management of children with illness and injury. Much of medical imaging requires ionizing radiation. While virtually all diagnostic imaging radiation is considered low-dose level, there is still a broad misperception about what modalities use ionizing radiation and how much radiation risk exists in the medical environment. A discussion of radiation exposure is especially relevant in children due to their increased vulnerability, including to radiation-induced cancer. Ionizing radiation is both naturally occurring and man-made, including medical sources that have been increasing over the past few decades and can vary in radiation dose both between different modalities and for similar examinations. Perspectives vary regarding cancer risk and levels of radiation resulting from diagnostic imaging, however most medical and scientific organization support the perspective that the risk of cancer at these levels is uncertain. It is important to have balanced and informed resources for the use of ionizing radiation in the care of children, and it is equally important to assure that the delivery of this content is appropriate to the audience to which it is intended. For these reasons, it is valuable to review the issues related to use of ionizing radiation in medical imaging in children.

54 ENVIRONMENTAL SCIENCES↗

Imaging the Aqueous Humor Outflow Pathway in Human Eyes by Three-dimensional Micro-computed Tomography (3D micro-CT)

The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.

59 BASIC BIOLOGICAL SCIENCES↗

Using geographic information science to evaluate legal restrictions on freight transportation routing in disruptive scenarios

Disasters have consequences and freight transportation is not immune from the effects of such disruptions. In the aftermath of disasters, planners and policymakers have to utilize scarce resources and work within legal frameworks to provide recovery for affected citizens and business. As seen with Hurricane Sandy, various observers noted the challenge with freight rerouting due to inoperable infrastructure and legal barriers involved with intermodal freight transportation. This paper focuses on how Geographic Information Systems (GIS); specifically WebTRAGIS (Transportation Routing Analysis GIS), a transportation routing platform developed at Oak Ridge National Laboratory, can be used to evaluate different routing options for freight transportation. In the case of freight transportation, the Merchant Marine Act of 1920 (also known as the Jones Act) restricts Short Sea Shipping (SSS) between coastwise points within U.S. territorial waters. This restriction leads to reliance on land-side modes for handling increased freight resulting from cargo diversion. Using Hurricane Sandy and the closure of the Port of New York/New Jersey as a case study, different modal studies were conducted; ultimately highlighting the various routes and provides insight into potential review of modal restrictions such as the Jones Act.

99 GENERAL AND MISCELLANEOUS↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D Ultrasound Can Contribute to Planning CT to Define the Target for Partial Breast Radiotherapy

Purpose: The role of three-dimensional breast ultrasound (3D US) in planning partial breast radiotherapy (PBRT) is unknown. This study evaluated the accuracy of coregistration of 3D US to planning computerized tomography (CT) images, the seroma contouring consistency of radiation oncologists using the two imaging modalities and the clinical situations in which US was associated with improved contouring consistency compared to CT. Materials and Methods: Twenty consecutive women with early-stage breast cancer were enrolled prospectively after breast-conserving surgery. Subjects underwent 3D US at CT simulation for adjuvant RT. Three radiation oncologists independently contoured the seroma on separate CT and 3D US image sets. Seroma clarity, seroma volumes, and interobserver contouring consistency were compared between the imaging modalities. Associations between clinical characteristics and seroma clarity were examined using Pearson correlation statistics. Results: 3D US and CT coregistration was accurate to within 2 mm or less in 19/20 (95%) cases. CT seroma clarity was reduced with dense breast parenchyma (p = 0.035), small seroma volume (p < 0.001), and small volume of excised breast tissue (p = 0.01). US seroma clarity was not affected by these factors (p = NS). US was associated with improved interobserver consistency compared with CT in 8/20 (40%) cases. Of these 8 cases, 7 had low CT seroma clarity scores and 4 had heterogeneously to extremely dense breast parenchyma. Conclusion: 3D US can be a useful adjunct to CT in planning PBRT. Radiation oncologists were able to use US images to contour the seroma target, with improved interobserver consistency compared with CT in cases with dense breast parenchyma and poor CT seroma clarity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗