Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An instrumented fastener for shear force measurements in joints

Results are presented of a preliminary investigation of instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Calibration test results show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double splice joints. The load distribution between individual fasteners is found to be dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, James W.↗

The performance of a new instrument for in situ measurements of ClO in the lower stratosphere

Abundances of chlorine oxide (ClO) have been measured from 16 km to 30 km by a new balloon-borne in situ instrument developed from an optical design flown previously on the NASA ER-2 aircraft. This instrument, a prototype for one to be flown on the Perseus remotely piloted aircraft, was one-third the weight of that on the ER-2, yet retained the high precision and accuracy necessary for detailed photochemical studies of the lower stratosphere. In this paper we discuss the performance of the instrument during its first flight on March 31, 1991 over eastern New Mexico.

Toohey, D. W.↗

Spectral Aerosol Extinction (SpEx): A New Instrument for In situ Ambient Aerosol Extinction Measurements Across the UV/Visible Wavelength Range

We introduce a new instrument for the measurement of in situ ambient aerosol extinction over the 300-700 nm wavelength range, the Spectral Aerosol Extinction (SpEx) instrument. This measurement capability is envisioned to complement existing in situ instrumentation, allowing for simultaneous measurement of the evolution of aerosol optical, chemical, and physical characteristics in the ambient environment. In this work, a detailed description of the instrument is provided along with characterization tests performed in the laboratory. Measured spectra of NO2 and polystyrene latex spheres agreed well with theoretical calculations. Good agreement was also found with simultaneous aerosol extinction measurements at 450, 530, and 630 nm using CAPS PMex instruments in a series of 22 tests including non-absorbing compounds, dusts, soot, and black and brown carbon analogs. SpEx can more accurately distinguish the presence of brown carbon from other absorbing aerosol due to its 300 nm lower wavelength limit compared to measurements limited to visible wavelengths. In addition, the spectra obtained by SpEx carry more information than can be conveyed by a simple power law fit that is typically defined by the use of Angstrom Exponents. Future improvements aim at lowering detection limits and ruggedizing the instrument for mobile operation.

Jordan, C. E.↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Intrinsic Line Shape Measurements of the XRS Instrument on Astro-E2

The XRS instrument on the Astro-E2 observatory contains a substantially improved microcalorimeter array over the Astro-E mission. In addition to roughly a factor of 2 improvement in the detector resolution at 6 keV, the detector response is shown to be almost perfectly gaussian. We have made measurements of the detector response of the flight instrument, using a double crystal monochrometer at 4 and 8 keV, a 55-Fe internal conversion source, and x-ray induced fluorescence from a number of targets including Ti, Cu, and GaAs. The detector response has been measured to be entirely gaussian to at least 2 orders of magnitude down from the peak of the line or line complex. This is in sharp contrast to the results from the XRS on Astro-E where many channels exhibited excess counts on the high energy side of the spectral lines. Here we present details of the line shape measurement as well as the detector response as measured during the XRS ground calibration including details of the line fits and line models.

Porter, F. Scott↗

Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

Bivolaru, Daniel↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

Spectral Measurements of PMCs from SBUV/2 Instruments

The SBUV/2 (Solar Backscattered Ultraviolet, model 2) instrument is designed to monitor ozone stratospheric profile and total column ozone using measurements of the Earth's backscattered ultraviolet albedo. We have previously demonstrated that the normal radiance measurements from SBUV/2 instruments, which sample 12 discrete wavelengths between 252 and 340 nm during each scan, can be used to identify polar mesospheric clouds (PMCs). Some SBUV/2 instruments also periodically view the earth in continuous scan mode, covering the wavelength range 160-400 nm with 0.15 nm sampling. Analysis of these data show PMC occurrence rates similar to the normal discrete scan results, although the observation technique reduces the number of daily measurements by a factor of six. PMC observed by SBUV/2 instruments show a monotonic variation in the residual spectral albedo over the wavelength range 250 300 nm, with maximum enhancements of 10 15% at 250 nm. This result is consistent with microphysical model predictions from Jensen [1989. A numerical model of polar mesospheric cloud formation and evolution, Ph. D. Thesis, University of Colorado]. We find no evidence for a systematic localized increase in PMC residual albedo for wavelengths near 260 nm, in contrast to the recently reported results from the MSX UVISI instrument [Carbary J.F., et al., 2004. Evidence for bimodal particle distribution from the spectra of polar mesospheric clouds. Geophysics Research. Letters 31, L13108]. This result is observed for three different SBUV/2 instruments in both Northern and Southern Hemisphere data over a 13-year span. Our Mie scattering calculations show that the location and magnitude of the 260 nm hump feature is dependent upon the specific scattering angles appropriate to the MSX measurements. Although it explains the MSX spectrum, the bimodal size distribution proposed by Carbary et al. (2004), cannot explain the lack of scattering angle dependence of the SBUV/2 spectral shapes. The spectral signature of the SBUV/2 continuous scan PMC data is thus inconsistent with the bimodal particle size distribution suggested by Carbary et al. (2004).

DeLand, Matthew T.↗

Merged Long-Term Data Sets from TOMS and SBUV Total Ozone Measurements

Total ozone has been measured by a series of nadir-viewing satellite instruments. These measurements begin with the Total Ozone Mapping Spectrometer (TOMS) and Solar Backscatter UltraViolet (SBUV) instruments on Nimbus 7, launched in late 1978. The measurements have continued with the Meteor 3 TOMS, Earth Probe TOMS, and NOAA 9,11,14 SBUV/2 instruments. The problem for producing a long-term data set is establishing the relative calibration of the various instruments to better than 1%. There was a nearly two year gap between the Meteor 3 TOMS and the Earth Probe TOMS. This gap is filled by the NOAA 9 and 11 SBUV/2 instruments, but they were in drifting orbits that result in effective gaps in the record when the equator crossing time occurs at large solar zenith angle. We have used recently re-derived calibrations of the SBUV instruments using the D-pair (306/313 nm wavelengths) data at the equator. These equatorial D-pair measurements should maintain the internal calibration of each instrument better than previous approaches. We then use the comparisons between instruments during their overlap periods to establish a consistent calibration over the entire data set. The resulting merged ozone data set is independent of the ground-based Dobson/Brewer network.

Stolarski, Richard↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

Specific Heat and Second Sound Measurements with the DYNAMIX Instrument

In addition to its primary role of studying non-linear heat transport effects near the lambda transition of He-4, the DYNAMX apparatus is suitable for measurements of the specific heat and the velocity of second sound. We plan to take advantage of available time on orbit to make measurements in these areas near to the lambda transition. The specific heat work would be similar to LPE, aimed at improving our knowledge of the singularity in the bulk heat capacity at the transition, but would provide more accurate results close to the transition. It would focus roughly equally on each side of the transition and would be synergistic with the CQ experiment, providing wider-range data at Q = 0. The second sound measurements are made possible by the fast time constant and high resolution of the DYNAMX thermometers, which allow accurate time-of-flight measurements of second sound pulses. It appears possible to measure the second sound velocity to about 1% at a reduced temperature of t = 5x10(exp -8) by averaging over a moderate number of pulses. The data would complement and extend earlier ground-based measurements, leading to improved tests of the theory of static critical phenomena at the lambda transition.

Nissen, Joel↗

Validation and Determination of Ice Water Content - Radar Reflectivity Relationships during CRYSTAL-FACE: Flight Requirements for Future Comparisons

In order for clouds to be more accurately represented in global circulation models (GCM), there is need for improved understanding of the properties of ice such as the total water in ice clouds, called ice water content (IWC), ice particle sizes and their shapes. Improved representation of clouds in models will enable GCMs to better predict for example, how changes in emissions of pollutants affect cloud formation and evolution, upper tropospheric water vapor, and the radiative budget of the atmosphere that is crucial for climate change studies. An extensive cloud measurement campaign called CRYSTAL-FACE was conducted during Summer 2002 using instrumented aircraft and a variety of instruments to measure properties of ice clouds. This paper deals with the measurement of IWC using the Harvard water vapor and total water instruments on the NASA WB-57 high-altitude aircraft. The IWC is measured directly by these instruments at the altitude of the WB-57, and it is compared with remote measurements from the Goddard Cloud Radar System (CRS) on the NASA ER-2. CRS measures vertical profiles of radar reflectivity from which IWC can be estimated at the WB-57 altitude. The IWC measurements obtained from the Harvard instruments and CRS were found to be within 20-30% of each other. Part of this difference was attributed to errors associated with comparing two measurements that are not collocated in time an space since both aircraft were not in identical locations. This study provides some credibility to the Harvard and CRS-derived IWC measurements that are in general difficult to validate except through consistency checks using different measurement approaches.

Sayres, D. S.↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

The Cloud Physics Lidar: Instrument Description and Initial Measurement Results

The new Cloud Physics Lidar (CPL) has been built for use on the NASA ER-2 high altitude aircraft. The purpose of the CPL is to provide multi-wavelength measurements of cirrus, subvisual cirrus, and aerosols with high temporal and spatial resolution. The CPL utilizes state-of-the-art technology with a high repetition rate, a low pulse energy laser, and photon-counting detection. The first deployment for the CPL was the SAFARI-2000 field campaign during August-September 2000. We provide here an overview of the instrument and initial data results to illustrate the measurement capability of the CPL.

McGill, Matthew↗

A Comparison of Measurements from ATMOS and Instruments Aboard the ER-2 Aircraft: Halogenated Gases

We compare volume mixing ratio profiles of N2O, CFC-11, CFC-12, CCl4, SF6, and HCl in the mid-latitude lower stratosphere measured by the ATMOS Fourier transform spectrometer on the ATLAS-3 Space Shuttle Mission with in situ measurements acquired from the NASA ER-2 aircraft during Nov. 1994. Good agreement is found between ATMOS and in situ correlations of [CFC-11], [CFC-12], and [SF6] with [N2O]. ATMOS measurements of [CCl4] are 15% high compared to ER-2 data, but agree within the systematic uncertainties. ATMOS observations of [HCl] vs [N2O] are within approximately 10% of ER-2 data for [HCl] > 1 ppbv, but exceed in situ measurements by larger fractional amounts for smaller [HCl]. ATMOS measurements of [ClONO2] agree well with values inferred from in situ observations of [ClO], [NO], and [O3]. The sum of [HCl] and [ClONO2] observed by ATMOS, supplemented by a minor contribution from [ClO] estimated with a photochemical model, is consistent with the levels of inorganic chlorine inferred from in situ measurements of chlorine source gases.

Chang, A. Y.↗

A Comparison of Measurements from ATMOS and Instruments Aboard the ER-2 Aircraft: Tracers of Atmospheric Transport

We compare volume mixing ratio profiles of N2O, O3, NO(y) H2O, CH4, and CO in the mid-latitude lower stratosphere measured by the ATMOS Fourier transform spectrometer on the ATLAS-3 Space Shuttle Mission with in situ measurements acquired from the NASA ER-2 aircraft during Nov 1994. ATMOS and ER-2 observations of [N2O] show good agreement, as do measured correlations of [O3], [NO(y)], [H2O], and [CH4] with [N2O]. Thus a consistent measure of the hydrogen (H2O, CH4) content of the lower stratosphere is provided by the two platforms. The similarity of [NO(y)] determined by detection of individual species by ATMOS and the total [NO(y)] measurement on the ER-2 provides strong corroboration for the accuracy of both techniques. A 25% discrepancy in lower stratospheric [CO] observed by ATMOS and the ER-2 remains unexplained. Otherwise, the agreement for measurements of long-lived tracers demonstrates the ability to combine ATMOS data with in situ observations for quantifying atmospheric transport.

Chang, A. Y.↗