Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Np-237 LoD Measurement by TIMS-Multi-Ion Counting Total Evaporation [Poster]

Requests for ultra-low-level 237 Np analyses highlight the importance of a robust chemical purification and measurement technique for Np. In FY2022, LANL is quantifying the instrumental 237 Np LoD. Need to incorporate a chemical purification procedure for TIMS-MICTE sample preparation. What is the recovery of the chemical purification procedure? What is the ultimate detection limit that can be achieved while incorporating a chemical purification procedure? We have adapted and refined the Pu TIMS-MICTE method for Np analyses. We have determined expected uncertainties for 237 Np TIMS-MICTE measurements. We have increased sensitivity through technique improvements. We have improved method reliability for Np analyses and increased throughput. Apply knowledge gained from progress made in FY2022 to further develop Np sample purification and analyses by TIMSMICTE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hemispherical variance anomaly and reionization optical depth

ABSTRACT Cosmic microwave background (CMB) full-sky temperature data show a hemispherical asymmetry in power nearly aligned with the Ecliptic, with the Northern hemisphere displaying an anomalously low variance, while the Southern hemisphere appears consistent with expectations from the best-fitting theory, Lambda Cold Dark Matter (ΛCDM). The low signal-to-noise ratio in current polarization data prevents a similar comparison. Polarization realizations constrained by temperature data show that in ΛCDM the lack of variance is not expected to be present in polarization data. Therefore, a natural way of testing whether the temperature result is a fluke is to measure the variance of CMB polarization components. In anticipation of future CMB experiments that will allow for high-precision large-scale polarization measurements, we study how the variance of polarization depends on ΛCDM-parameter uncertainties by forecasting polarization maps with Planck’s Markov chain Monte Carlo chains. We show that polarization variance is sensitive to present uncertainties in cosmological parameters, mainly due to current poor constraints on the reionization optical depth τ, which drives variance at low multipoles. We demonstrate how the improvement in the τ measurement seen between Planck’s two latest data releases results in a tighter constraint on polarization variance expectations. Finally, we consider even smaller uncertainties on τ and how more precise measurements of τ can drive the expectation for polarization variance in a hemisphere close to that of the cosmic-variance-limited distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision luminosity measurement in proton–proton collisions at $\sqrt{s}$ = 13 TeV in 2015 and 2016 at CMS

The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton–proton collisions at √s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb -1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficacy of the Method of Four Coefficients to Determine Charge-Carrier Scattering

The investigation of the electronic properties of semiconductors from transport measurements (i.e., resistivity, Hall, and Seebeck coefficient measurements) is challenging due to the averaging of charge-carrier dynamics inherent in such measurements. Here, we investigate the incorporation of a fourth measurement of electronic transport, the Nernst coefficient, into the analysis, termed the method of four coefficients. This approach yields the Fermi level, effective mass, scattering exponent, and relaxation time prefactor. We begin with a review of the underlying mathematics and investigate the mapping between the four-dimensional material property and transport coefficient spaces. We then investigate how the traditional single-parabolic band method yields a single, potentially incorrect point on the solution subspace. This uncertainty can be resolved through Nernst coefficient measurements and we map the span of the ensuing subspace. We conclude with an investigation of how sensitive the analysis of transport coefficients is to experimental error for different sample types.

charge carriers↗

Quantifying model prediction sensitivity to model-form uncertainty

Computational and mathematical models are essential to understanding complex systems and phenomena. However, when developing such models, limited knowledge and/or resources necessitates the use of simplifying assumptions. It is therefore crucial to quantify the impact of such simplifying assumptions on the reliability and accuracy of resulting model predictions. This work develops a first-of-its-kind approach to quantify the impact of physics modeling assumptions on predictions. Here, we leverage the emerging field of model-form uncertainty (MFU) representations, which are parameterized modifications to modeling assumptions, in combination with grouped Sobol’ indices to quantitatively measure an assumption’s importance. Specifically, we compute the grouped Sobol’ index for the MFU representation’s parameters as a single importance measure of the assumption for which the MFU representation characterizes uncertainty. To ensure this approach is robust to the subjective choice of how to parameterize a MFU representation, we establish bounds for the difference between sensitivity results for two different MFU representations based on differences in model prediction statistics. The capabilities associated with this approach are demonstrated on three exemplar problems: an upscaled subsurface contaminant transport problem, ablation modeling for hypersonic flight, and nuclear waste repository modeling. We found that our grouped approach is able to assess the impact of modeling assumptions on predictions and offers computational advantages over classical Sobol’ index computation while providing more interpretable results.

97 MATHEMATICS AND COMPUTING↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Precision Measurement of the Parity Violating Asymmetry in Cold Neutron Capture on 3 He

We report the first precision measurement of the parity-violating asymmetry in the direction of proton momentum with respect to the neutron spin, in the reaction 3 He(n,p) 3 H, using the capture of polarized cold neutrons in an unpolarized active 3 He target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the least well-understood aspects of electroweak theory. The measurement provides an important benchmark for modern effective field theory and potential model calculations. Measurements like this are necessary to determine the spin-isospin structure of the hadronic weak interaction. Our asymmetry result is A PV =[1.55±0.97(stat)±0.24(sys)]×10 -8 , which has the smallest uncertainty of any hadronic parity-violating asymmetry measurement so far.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Differential Charged Current $\nu_{\mu}$ - Argon Cross Section without Pions in the Final State Measurement in MicroBooNE

MicroBooNE, an 85-tonne liquid argon time projection chamber (LArTPC) detector is on-axis to the Booster Neutrino Beam (BNB) beamline facility at Fermi National Accelerator Laboratory. MicroBooNE is elucidating neutrino interactions with argon through cross-section measurements to refine interaction models and reduce uncertainties. In this poster, we present the status of the single and double multi-differential charged current (CC) cross section with zero pions in the final state (CC-0$\pi$) as a function of muon momentum ($0.1<p_\mu<2.0\,\mathrm{GeV/c}$) and the cosine of the muon angle ($-1<\cos\theta_\mu<1$). We present the details of the event selection and cross section extraction along with a set of tests using fake data to establish the robustness of the analysis methodology. We also discuss prospects for a future combined measurement with the Gd-H$_2$O target at the ANNIE experiment, to explore MicroBooNE’s proton multiplicity alongside ANNIE’s neutron multiplicity.

43 PARTICLE ACCELERATORS↗

A Measurement of the Total Hadronic $\pi^-$ on Argon Cross Section in the Kinetic Energy Range from 0.2-1 Giga-Electron Volts in a Liquid Argon Time Projection Chamber

The liquid argon time projection chamber (LArTPC) technology offers fine-grained tracking along with excellent calorimetric and particle identification capabilities, making it a powerful tool for experimental neutrino physics. Thus, the LArTPC has become the technology of choice for studying neutrino oscillations over short ( 1000 km) baselines by experiments such as MicroBooNE, SBND, ICARUS, and DUNE. The LArIAT (Liquid Argon in a Test-beam) experiment exposes a LArTPC to a controlled beam of charged particles at the Fermilab Test Beam Facility to perform calibration studies and measurements of charged hadron-argon cross sections, with the goal of helping to reduce systematic uncertainties in LArTPC-based neutrino experiments. This work presents a measurement of the total hadronic π⁻-Ar cross section in the kinetic energy range from 0.2 GeV to 1 GeV, using data from the LArIAT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Intrusive Measurements Using Femtosecond Laser in Atmospheric Pressure Plasma Jet

Femto-second (fs) lasers offer state-of-the art non-intrusive diagnostic capabilities in plasma flow environments. The diagnostics in plasma flows using a fs-laser that are relevant to this proposal include Two-photon Absorption Laser Induced Fluorescence (TALIF) for measuring the number density of an atomic species, and Femto-second Laser Electronic Excitation Tagging (FLEET) for performing velocity measurements in plasma flows. Various aspects of these diagnostics using fs-lasers are still an active domain of research. The TALIF technique has been used to measure the number density of atomic species in various plasma flow environments like atmospheric pressure plasma jet (APPJ) and arc-jet flows. This technique utilizes a fs-laser to excite an atomic species and the subsequent relaxation process through fluorescence is recorded to make measurements. A narrow band-pass filter is used to isolate the fluorescence signal that is in the infra-red regime. However, broad-band background emissions can potentially pass through the filter and induce noise in the TALIF signal. Particularly, arc-jet plasma flows inherently contain background emissions. In such plasma flow environments, in addition to the filter, the background-subtraction technique will play an important role in reducing the noise that is induced in the number density measurements using TALIF. The proposed research focuses on evaluating the effectiveness of a background-subtraction technique by measuring atomic oxygen using a femtosecond (fs) TALIF in APPJ with induced background emissions and comparing measurements obtained without inducing the emissions. Therefore, by quantifying the changes in the signal-to-noise ratio caused by a background-subtraction technique applied for APPJ, it will enable a better understanding of the uncertainties in the background subtracted fs-TALIF measurements for arc-jet plasma flows. In addition to this, FLEET will be used to obtain velocity in the APPJ, and the impact of background emissions will be analyzed. Under this effort, the experimenters and research personnel will gain the technical know-how in the operational and theoretical aspects of the advanced fs-laser-based diagnostic techniques. The knowledge gained in this process will then also directly be applied to a separate ONR funded project at the Aerodynamics Research Center (ARC), UT Arlington, related to arc-jet flow characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmological inference from an emulator based halo model. II. Joint analysis of galaxy-galaxy weak lensing and galaxy clustering from HSC-Y1 and SDSS

Here, we present high-fidelity cosmology results from a blinded joint analysis of galaxy-galaxy weak lensing (ΔΣ) and projected galaxy clustering (w p ) measured from the Hyper Suprime-Cam Year-1 (HSC-Y1) data and spectroscopic Sloan Digital Sky Survey (SDSS) galaxy catalogs in the redshift range 0.15 < z < 0.7. We define luminosity-limited samples of SDSS galaxies to serve as the tracers of w p in three spectroscopic redshift bins, and as the lens samples for ΔΣ. For the ΔΣ measurements, we select a single sample of 4×10 6 source galaxies over 140 deg 2 from HSC-Y1 with photometric redshifts (photo z) greater than 0.75, enabling a better handle of photo- z errors by comparing the ΔΣ amplitudes for the three lens redshift bins. The deep, high-quality HSC-Y1 data enable significant detections of the ΔΣ signals, with integrated signal-to-noise ratio S/N ~ 15 in the range 3 ≤ R/[h –1 Mpc] ≤ 30 for the three lens samples, despite the small area coverage. For cosmological parameter inference, we use an input galaxy-halo connection model built on the dark emulator package (which uses an ensemble set of high-resolution N-body simulations and enables fast, accurate computation of the clustering observables) with a halo occupation distribution that includes nuisance parameters to marginalize over modeling uncertainties. We model the ΔΣ and wp measurements on scales from R≃3 and 2h –1 Mpc , respectively, up to 30 h –1 Mpc (therefore excluding the baryon acoustic oscillations information) assuming a flat Λ CDM cosmology, marginalizing over about 20 nuisance parameters and demonstrating the robustness of our results to them. With various tests using mock catalogs described in Miyatake et al. [preceding paper, Phys. Rev. D 106, 083519 (2022)], we show that any bias in the clustering amplitude S 8 ≡ σ 8 (Ω m /0.3) 0.5 due to uncertainties in the galaxy-halo connection is less than ~ 50 % of the statistical uncertainty of S 8 , unless the assembly biaseffect is unexpectedly large. Our best-fit models have S 8 = 0.795$_{-0.042}^{+0.049}$ (mode and 68% credible interval) for the flat Λ CDM model; we find tighter constraints on the quantity S 8 (α = 0.17)≡σ 8 (Ω m /0.3) 0.17 = 0.745$_{-0.031}^{+0.039}$.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermodynamic investigation of the NaCl-KCl salt system from 25 to 950 °C

NaCl-KCl molten salt system has been proposed as a primary component of several promising heat transfer eutectics and fuel host for Generation IV molten salt reactors (MSR). In this work, several key thermodynamic parameters, including high temperature enthalpies, isobaric heat capacities (C p ) and molar enthalpies of mixing (ΔH mix ), of the NaCl -KCl system (NaCl, 75mol% NaCl – 25mol% KCl, 51mol% NaCl – 49mol% KCl, 25mol% NaCl – 75mol% KCl, and KCl) were measured by high temperature drop calorimetry (HTDC) utilizing laser sealed nickel and aluminum crucibles. Salts were checked for phase purity by X-ray diffraction (XRD), and water content by Karl Fischer coulometric titrimetry and thermogravimetric analysis (TGA). Thermo-mechanical analysis (TMA) utilizing custom-built boron nitride (BN) crucibles was employed to determine temperatures of phase transitions (solid $\rightarrow$ liquid) for the salts and plotted against the pseudobinary phase diagram for the NaCl-KCl system. Small deviations (3-10 %) were found among C p values obtained from HTDC, differential scanning calorimetry (DSC), and NIST, comparable to the average uncertainty based on two standard deviations of measured data that are ~6% for DSC and ~3% for HTDC. Additionally, the measured enthalpies and C p values of mixed NaCl-KCl salts (e.g., 51mol% NaCl – 49mol% KCl eutectic) were shown to behave as statistical mixtures of its pure endmembers, consistent with ΔH mix = ~ 0 kJ/mol at 800 °C, and a regular interaction parameter of Ω = 1.20 ± 0.76 kJ/mol. In conclusion, this study represents a step towards improved accuracy and precision in determinations of thermodynamic parameters of molten salts by using DSC, TMA, and HTDC, in completion of the Molten Salt Thermal Properties Database (MSTDB).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the $\Upsilon$(1S) pair production cross section and search for resonances decaying to $\Upsilon$(1S)$\mu^+\mu^-$ in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The fiducial cross section for Y(1S) pair production in proton-proton collisions at a center-of-mass energy of 13 TeV in the region where both Y(1S) mesons have an absolute rapidity below 2.0 is measured to be 79±11(stat)±6(syst)±3(B) pb assuming the mesons are produced unpolarized. The last uncertainty corresponds to the uncertainty in the Y(1S) meson dimuon branching fraction. The measurement is performed in the final state with four muons using proton-proton collision data collected in 2016 by the CMS experiment at the LHC, corresponding to an integrated luminosity of 35.9 fb−1 . This process serves as a standard model reference in a search for narrow resonances decaying to Y(1S)μ+μ− in the same final state. Such a resonance could indicate the existence of a tetraquark that is a bound state of two b quarks and two b¯ antiquarks. The tetraquark search is performed for masses in the vicinity of four times the bottom quark mass, between 17.5 and 19.5 GeV, while a generic search for other resonances is performed for masses between 16.5 and 27 GeV. No significant excess of events compatible with a narrow resonance is observed in the data. Limits on the production cross section times branching fraction to four muons via an intermediate Y(1S) resonance are set as a function of the resonance mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗