Investigation of a submerged membrane reactor for continuous biomass hydrolysis
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The dispersion and location of Pd in alumina-supported sorbents prepared by different methods was found to influence the performance of the sorbents in the removal of mercury, arsine, and hydrogen selenide from a simulated fuel gas. When Pd is well dispersed in the pores of the support, contact interaction with the support is maximized, Pd is less susceptible to poisoning by sulfur, and the sorbent has better long-term activity for adsorption of arsine and hydrogen selenide, but poorer adsorption capacity for Hg. As the contact interaction between Pd and the support is lessened the Pd becomes more susceptible to poisoning by sulfur, resulting in higher capacity for Hg, but poorer long-term performance for adsorption of arsenic and selenium.
An optimization approach that incorporates the predictive transport code TRANSP is proposed for tokamak scenario development. Optimization methods are often employed to develop open-loop control strategies to aid access to high performance tokamak scenarios. Generally, the optimization approaches use control-oriented models, i.e. models that are reduced in complexity and prediction accuracy as compared to physics-oriented transport codes such as TRANSP. In the presented approach, an optimization procedure using the TRANSP code to simulate the tokamak plasma is considered for improved predictive capabilities. As a test case, the neutral beam injection (NBI) power is optimized to develop a control strategy that maximizes the noninductive current fraction during the ramp-up phase for NSTX-U. Simulation studies towards the achievement of noninductive ramp-up in NSTX-U have already been carried out with the TRANSP code. The optimization-based approach presented in this work is used to maximize the noninductive current fraction during ramp-up in NSTX-U, demonstrating that the scenario development task can be automated. An additional test case considers optimization of the current ramp rate in DIII-D for obtaining a stationary plasma characterized by a flat loop voltage profile in the flattop phase.
Resource constraints on the computing continuum require that we make smart decisions for serving AI-based services at the network edge. AI-based services typically have multiple implementations (e.g., image classification implementations include SqueezeNet, DenseNet, and others) with varying trade-offs (e.g., latency and accuracy). The question then is how should AI-based services be placed across Function-as-a-Service (FaaS) based edge computing systems in order to maximize total Quality-of-Service (QoS). To address this question, we propose a problem that jointly aims to solve (i) edge AI service placement and (ii) request scheduling. These are done across two time-scales (one for placement and one for scheduling). Here we first cast the problem as an integer linear program. We then decompose the problem into separate placement and scheduling subproblems and prove that both are NP-hard. We then propose a novel placement algorithm that places services while considering device-to-device communication across edge clouds to offload requests to one another. Our results show that the proposed placement algorithm is able to outperform a state-of-the-art placement algorithm for AI-based services, and other baseline heuristics, with regard to maximizing total QoS. Additionally, we present a federated learning-based framework, FLIES, to predict the future incoming service requests and their QoS requirements. Our results also show that our FLIES algorithm is able to outperform a standard decentralized learning baseline for predicting incoming requests and show comparable predictive performance when compared to centralized training.
The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.
Therapeutic proteins may be subjected to several freeze–thaw cycles throughout manufacturing and storage. The protein solution composition and the freezing conditions may lead to incomplete ice crystallization in the frozen state. This can also result in freeze-concentrate heterogeneity characterized by multiple glass transition temperatures and protein destabilization. The overall objective was to investigate the potential advantages of including a crystallizing excipient (mannitol) along with a sugar (sucrose or trehalose) for frozen storage. Here, this study showed that the addition of mannitol, a readily crystallizing excipient, facilitated ice crystallization. Inclusion of an isothermal hold during cooling (annealing) maximized the mannitol crystallization and resulted in a homogenous freeze-concentrate of a constant composition characterized by a single glass transition temperature. The role of freezing rate and annealing on both mannitol and ice crystallization were discerned using high intensity synchrotron radiation. The addition of sucrose or trehalose, at an appropriate concentration, stabilized the protein. The mannitol to sugar ratio (3:1 or 1:1, 5 % w/v) was optimized to selectively cause maximal crystallization of mannitol while retaining the sugar amorphous. Human serum albumin (1 mg/mL) in these optimized and annealed compositions did not show any meaningful aggregation, even after multiple freeze–thaw cycles. Thus, in addition to a sugar as a stabilizer, the use of a crystallizing excipient coupled with an annealing step can provide an avenue for frozen storage of proteins.
Purpose: Motexafin gadolinium (MGd) is a putative radiation enhancer initially evaluated in patients with brain metastases. This Phase I trial studied the safety and tolerability of a 2-6-week course (10-22 doses) of MGd with radiotherapy for glioblastoma multiforme. Methods and Materials: A total of 33 glioblastoma multiforme patients received one of seven MGd regimens starting at 10 doses of 4 mg/kg/d MGd and escalating to 22 doses of 5.3 mg/kg/d MGd (5 or 10 daily doses then three times per week). The National Cancer Institute Cancer Therapy Evaluation Program toxicity and stopping rules were applied. Results: The maximal tolerated dose was 5.0 mg/kg/d MGd (5 d/wk for 2 weeks, then three times per week) for 22 doses. The dose-limiting toxicity was reversible transaminase elevation. Adverse reactions included rash/pruritus (45%), chills/fever (30%), and self-limiting vesiculobullous rash of the thumb and fingers (42%). The median survival of 17.6 months prompted a case-matched analysis. In the case-matched analysis, the MGd patients had a median survival of 16.1 months (n = 31) compared with the matched Radiation Therapy Oncology Group database patients with a median survival of 11.8 months (hazard ratio, 0.43; 95% confidence interval, 0.20-0.94). Conclusion: The maximal tolerated dose of MGd with radiotherapy for glioblastoma multiforme in this study was 5 mg/kg/d for 22 doses (daily for 2 weeks, then three times weekly). The baseline survival calculations suggest progression to Phase II trials is appropriate, with the addition of MGd to radiotherapy with concurrent and adjuvant temozolomide.
Purpose: We prospectively determined whether the change in tumor volume (TV) during 2 months of neoadjuvant androgen suppression therapy (nAST) measured using conventional 1.5 Tesla endorectal magnetic resonance imaging (eMRI) was associated with the risk of recurrence after radiation (RT) and 6 months of AST. Patients and Methods: Between 1997 and 2001, 180 men with clinical stage T1c-T3cN0M0 adenocarcinoma of the prostate were registered. Fifteen were found to be ineligible and the institutional MR radiologist could not assess the TV in 32, leaving 133 for analysis. Multivariable Cox regression analysis was used to assess whether a significant association existed between eMRI-defined TV progression during nAST and time to recurrence adjusting for prostate-specific antigen (PSA) level, Gleason score (8 to 10 or 7 vs. 6 or less) and stage (T3 vs. T1-2). Results: After a median follow up of 6.7 years and adjusting for known prognostic factors, there was a significant increase in the risk of PSA failure (HR, 2.3 [95% CI, 1.1-4.5; p = 0.025) in men with eMRI-defined TV progression during nAST. Specifically, adjusted estimates of PSA failure were significantly higher (p = 0.032) in men with, compared with men without, eMRI-defined TV progression reaching 38% vs. 19%, respectively, by 5 years. Conclusion: Eradicating intraprostatic hormone refractory prostate cancer (HRPC) by maximizing local control and randomized trials assessing whether survival is improved when agents active against HRPC are combined with maximal local therapy are needed in men who progress based on eMRI during nAST.
Purpose: To identify the maximal tolerated dose level of preoperative intensity-modulated radiotherapy combined with capecitabine and oxaliplatin and to evaluate the efficacy. Patients and Methods: Patients with rectal T3-T4 and/or N0-N+ rectal cancer received capecitabine 825 mg/m{sup 2} twice daily Monday through Friday and oxaliplatin 60 mg/m{sup 2} intravenously on Days 1, 8, and 15, concurrently with intensity-modulated radiotherapy. The radiation dose was increased in 5.0-Gy steps in cohorts of 3 patients starting from 37.5 Gy in 15 fractions (dose level [DL] 1). DL2 and DL3 were designed to reach 42.5 Gy in 17 fractions and 47.5 Gy in 19 fractions, respectively. Results: No dose-limiting toxicity was observed at DL1 or DL2. Of the 3 patients treated at DL3, 1 presented with Grade 3 diarrhea, which was considered a dose-limiting toxicity, and 3 additional patients were added. Of the 6 patients treated at DL3, no new dose-limiting toxicities were observed, and DL3 was identified as the recommended dose in this study. Eight additional patients were treated at 47.5 Gy. Grade 2 proctitis was the most frequent adverse event (40%); Grade 3 diarrhea occurred in 2 patients (10%). All patients underwent surgery, and 17 patients (85%) underwent R0 resection. Four patients (20%) presented with a histologic response of Grade 4, 11 (55%) with Grade 3+, 2 (15%) with Grade 3, and 2 patients (10%) with Grade 2. Conclusion: The maximal tolerated dose in this study was 47.5 Gy. The high rates of pathologic response of Grade 3+ and 4 must be confirmed through the accrual of new patients in the Phase II study.
Purpose: To measure the three-dimensional motion of liver tumors using cine-magnetic resonance imaging (MRI) and compare it to the liver motion assessed using fluoroscopy. Methods and Materials: Liver and liver tumor motion were investigated in the first 36 patients with primary (n = 20) and metastatic (n = 16) liver cancer accrued to our Phase I stereotactic radiotherapy study. At simulation, all patients underwent anteroposterior fluoroscopy, and the maximal diaphragm excursion in the craniocaudal (CC) direction was observed. Cine-MRI using T{sub 2}-weighted single shot fast spin echo sequences were acquired in three orthogonal planes during free breathing through the centroid of the most dominant liver tumor. ImageJ software was used to measure the maximal motion of the tumor edges in each plane. The intra- and interobserver reproducibility was also quantified. Results: The average CC motion of the liver at fluoroscopy was 15 mm (range, 5-41). On cine-MRI, the average CC tumor motion was 15.5 mm (range, 6.9-35.4), the anteroposterior motion was 10 mm (range, 3.7-21.6), and the mediolateral motion was 7.5 mm (range, 3.8-14.8). The fluoroscopic CC diaphragm motion did not correlate well with the MRI CC tumor motion (r = 0.25). The mean intraobserver error was <2 mm in the CC, anteroposterior, and mediolateral directions, and 90% of measurements between observers were within 3 mm. Conclusions: The results of our study have shown that cine-MRI can be used to directly assess liver tumor motion in three dimensions. Tumor motion did not correlate well with the diaphragm motion measured using kilovoltage fluoroscopy. The tumor motion data from cine-MRI can be used to facilitate individualized planning target volume margins to account for breathing motion.
Purpose: To investigate equivalent regimens for hypofractionated stereotactic radiotherapy (HSRT) for brain tumor treatment and to provide dose-escalation guidance to maximize the tumor control within the normal brain tolerance. Methods and Materials: The linear-quadratic model, including the effect of nonuniform dose distributions, was used to evaluate the HSRT regimens. The {alpha}/{beta} ratio was estimated using the Gammaknife stereotactic radiosurgery (GKSRS) and whole-brain radiotherapy experience for large brain tumors. The HSRT regimens were derived using two methods: (1) an equivalent tumor control approach, which matches the whole-brain radiotherapy experience for many fractions and merges it with the GKSRS data for few fractions; and (2) a normal-tissue tolerance approach, which takes advantages of the dose conformity and fractionation of HSRT to approach the maximal dose tolerance of the normal brain. Results: A plausible {alpha}/{beta} ratio of 12 Gy for brain tumor and a volume parameter n of 0.23 for normal brain were derived from the GKSRS and whole-brain radiotherapy data. The HSRT prescription regimens for the isoeffect of tumor irradiation were calculated. The normal-brain equivalent uniform dose decreased as the number of fractions increased, because of the advantage of fractionation. The regimens for potential dose escalation of HSRT within the limits of normal-brain tolerance were derived. Conclusions: The designed hypofractionated regimens could be used as a preliminary guide for HSRT dose prescription for large brain tumors to mimic the GKSRS experience and for dose escalation trials. Clinical studies are necessary to further tune the model parameters and validate these regimens.
Purpose: To examine the dosimetric impact of margin reduction and quantify residual error after three-dimensional (3D) image registration using daily cone-beam computed tomography (CBCT) for prostate cancer patients. Methods and Materials: One hundred forty CBCTs from 5 prostate cancer patients were examined. Two intensity-modulated radiotherapy plans were generated on CT simulation on the basis of two planning target volume (PTV) margins: 10 mm all around the prostate and seminal vesicles except 6 mm posteriorly (10/6) and 5 mm all around except 3 mm posteriorly (5/3). Daily CBCT using the Varian On-Board Imaging System was acquired. The 10/6 and 5/3 simulation plans were overlaid onto each CBCT, and each CBCT plan was calculated. To examine residual error, PlanCT/CBCT intensity-based 3D image registration was performed for prostate localization using center of mass and maximal border displacement. Results: Prostate coverage was within 2% between the 10/6 and 5/3 plans. Seminal vesicle coverage was reduced with the 5/3 plan compared with the 10/6 plan, with coverage difference within 7%. The 5/3 plan allowed 30-50% sparing of bladder and rectal high-dose regions. For residual error quantification, center of mass data show that 99%, 93%, and 96% of observations fall within 3 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. Maximal border displacement observations range from 79% to 99%, within 5 mm for all directions. Conclusion: Cone-beam CT dosimetrically validated a 10/6 margin when soft-tissue localization is not used. Intensity-based 3D image registration has the potential to improve target localization and to provide guidelines for margin definition.
Purpose: To describe the frequency of acute and late Radiation Therapy Oncology Group (RTOG) urinary toxicity, associated predictive factors, and resolution of International Prostate Symptom Score (IPSS) in 712 consecutive prostate brachytherapy patients. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). The IPSS and RTOG toxicity data were prospectively collected. The patient, treatment, and implant factors were examined for an association with urinary toxicity. The time to IPSS resolution was examined using Kaplan-Meier curves, and multivariate modeling of IPSS resolution was done using Cox proportional hazards regression analysis. Logistic regression analysis was used to examine the factors associated with urinary toxicity. Results: The IPSS returned to baseline at a median of 12.6 months. On multivariate analysis, patients with a high baseline IPSS had a quicker resolution of their IPSS. Higher prostate D90 (dose covering 90% of the prostate), maximal postimplant IPSS, and urinary retention slowed the IPSS resolution time. The rate of the actuarial 5-year late urinary (>12 months) RTOG Grade 0, 1, 2, 3, and 4 was 32%, 36%, 24%, 6.2%, and 0.1%, respectively. At 7 years, the prevalence of RTOG Grade 0-1 was 92.5%. Patients with a larger prostate volume, greater number of needles, greater baseline IPSS, and use of hormonal therapy had more acute toxicity. On multivariate analysis, the significant predictors for late greater than or equal to RTOG toxicity 2 were a greater baseline IPSS, maximal postimplant IPSS, presence of acute toxicity, and higher prostate V150 (volume of the prostate covered by 150% of the dose). More recently implanted patients had less acute urinary toxicity and patients given hormonal therapy had less late urinary toxicity (all p < 0.02). Conclusion: Most urinary symptoms resolved within 12 months after prostate brachytherapy, and significant long-term urinary toxicity was very low. Refined patient selection and greater technical experience in prostate brachytherapy were associated with less urinary toxicity.
Purpose: Three-dimensional (3D) treatment planning has reduced the cardiac dose in postoperative radiotherapy for breast cancer; however, the overall cardiac toxicity is still an issue because of more aggressive adjuvant treatment. Toxicity models have suggested that a reduction of the heart volume treated to high doses might be particularly advantageous. We compared aperture-based multifield intensity-modulated radiotherapy (IMRT) plans to 3D-planned tangent fields using dose-volume histograms, cardiac toxicity risk, and the robustness to positioning errors. Methods and Materials: For 14 computed tomography data sets of patients with left-sided breast cancer (unfavorable thoracic geometry), a 3D treatment plan and an IMRT plan were created. The dose-volume histograms were evaluated for the target and risk organs. Excess risk of cardiac mortality was calculated for both approaches using a relative seriality model. Positioning errors were simulated by moving the isocenter. Results: IMRT reduced the maximal dose to the left ventricle by a mean of 30.9% (49.14 vs. 33.97 Gy). The average heart volume exposed to >30 Gy was reduced from 45 cm{sup 3} to 5.84 cm{sup 3}. The mean dose to the left ventricle was reduced by an average of 10.7% (10.86 vs. 9.7 Gy), and the mean heart dose increased by an average of 24% (from 6.85 to 8.52 Gy). The model-based reduction of the probability for excess therapy-associated cardiac death risk was from 6.03% for the 3D plans to 0.25% for the IMRT plans. Conclusion: Aperture-based IMRT for left-sided breast cancer significantly reduces the maximal dose to the left ventricle, which might translate into reduced cardiac mortality. Biological modeling might aid in deciding to treat with IMRT but has to be validated prospectively.
Purpose: To describe the histologic and volumetric changes in normal liver tissue after stereotactic body radiotherapy (SBRT) for liver metastases. Methods and Materials: Pre- and post-SBRT imaging studies were analyzed to evaluate the effect of SBRT on normal liver volume (NLV) in 15 patients treated in a prospective clinical trial. Two other patients underwent exploratory surgery after SBRT and histologic analyses of the irradiated liver were performed to characterize the pathologic effects of SBRT. Results: In the 15 patients studied quantitatively, the total NLV had decreased transiently at 2-3 months after SBRT and then began to regenerate at 3-8 months after SBRT. The median NLV reduction at the maximal observed effect was 315 cm{sup 3} (range, 125-600) or 19% (range, 13-33%). Among the several dosimetric parameters evaluated, the strongest linear correlation was noted for the NLV percentage receiving 30 Gy as a predictor of maximal NLV reduction (r{sup 2} = 0.72). The histologic changes observed 2 and 8 months after SBRT demonstrated distinct zones of tissue injury consistent with localized veno-occlusive disease. Conclusion: The well-demarcated focal parenchymal changes after liver SBRT (demonstrated both radiographically and histologically) within the high-dose zone are consistent with a threshold dose-induced set of phenomena. In contrast, the more global effect of NLV reduction, which is roughly proportional to whole organ dose parameters, resembles more closely an effect determined from radiobiologically parallel architecture. These observations suggest that modeling of normal tissue effects after liver SBRT might require different governing equations for different classes of effects.
Purpose: We have used dynamic conformal multiple arc therapy (DCMAT) for stereotactic body radiotherapy (SBRT) since 2001. We investigated the consistency of DCMAT for SBRT using dose-volume histogram analysis. Methods and Materials: A total of 50 patients with peripheral lung tumors underwent SBRT. The median tumor diameter was 2.4 cm (range, 0.9-5.9). Treatment planning was performed using a superposition algorithm. The prescribed 50 Gy dose was divided into five fractions. The prescribed dose was defined as 80% of the maximal dose in the planning target volume (PTV), and the leaf margins were modified to ensure the PTV was included in the 80% isodose surface. The dose-volume histogram analysis was used to assess the PTV and normal lung volume. Results: The median dose covering 95% of the PTV was 50.27 Gy (range, 46.14-52.67), essentially consistent with the prescribed dose. The median homogeneity and conformity index was 1.41 (range, 1.31-1.53) and 1.73 (range, 1.41-2.21), respectively. The median volume of lung receiving {>=}20 Gy (V{sub 20}) was 4.2% (range, 1.4-10.2%). A linear correlation was found between the tumor diameter and V{sub 20}, and an even stronger correlation was found between the PTV/(normal lung volume) and V{sub 20}. The estimated V{sub 20} was 7.1% (range, 3.9-10.4%) for a 5-cm-diameter tumor, assumed to be the maximal size limitation for SBRT. Conclusion: SBRT with DCMAT achieved high conformity and delivered adequate doses within the PTV. The median dose covering 95% of the PTV was consistent with the prescribed dose. V{sub 20} can be estimated using the tumor diameter and normal lung volume. DCMAT was thus both a feasible and a reproducible method of SBRT delivery.
Purpose: To describe the late transient worsening of urinary symptoms ('urinary symptom flare') in 712 consecutive prostate brachytherapy patients, associated predictive factors, association with rectal and urinary toxicity, and the development of erectile dysfunction. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). International Prostate Symptom Score (IPSS), Radiation Therapy Oncology Group (RTOG) toxicity, and erectile function data were prospectively collected. Flare was defined as an increase in IPSS of >=5 and of >=8 points greater than the post-treatment nadir. The relationships between the occurrence of flare and the patient, tumor, and treatment characteristics were examined. The Cox proportional hazards method was used to test individual variables and the multivariate models. Results: The incidence of flare was 52% and 30% using the flare definition of an IPSS of >=5 and >=8 points greater than the postimplant nadir, respectively. Of the patients with symptoms, 65% had resolution of their symptoms within 6 months and 91% within 1 year. Flares most commonly occurred 16-24 months after implantation. On multivariate analysis, a greater baseline IPSS and greater maximal postimplant IPSS were the predictors of flare, regardless of the flare definition used. Androgen suppression was a predictor for fewer flares (IPSS >=5). Diabetes and prostate edema predicted for more frequent flares (IPSS >=8). Patients with flare had a greater incidence of RTOG Grade 3 urinary toxicity and RTOG Grade 2 or greater rectal toxicity. No association was found between erectile dysfunction and the occurrence of flare. Conclusion: Urinary symptom flare is a common, transient phenomenon after prostate brachytherapy. A greater baseline IPSS and maximal postimplant IPSS were the strongest predictive factors. Flare was associated with a greater incidence of late RTOG Grade 3 urinary toxicity and greater rate of late RTOG Grade 2 or greater rectal toxicity.
Purpose: To describe and evaluate the modified lateral decubitus boost, a breast irradiation technique. Patients are repositioned and resimulated for electron boost to minimize the necessary depth for the electron beam and optimize target volume coverage. Methods and Materials: A total of 2,606 patients were treated with post-lumpectomy radiation at our institution between January 1, 2000, and February 1, 2008. Of these, 231 patients underwent resimulation in the lateral decubitus position with electron boost. Distance from skin to the maximal depth of target volume was measured in both the original and boost plans. Age, body mass index (BMI), boost electron energy, and skin reaction were evaluated. Results: Resimulation in the lateral decubitus position reduced the distance from skin to maximal target volume depth in all patients. Average depth reduction by repositioning was 2.12 cm, allowing for an average electron energy reduction of approximately 7 MeV. Mean skin entrance dose was reduced from about 90% to about 85% (p < 0.001). Only 14 patients (6%) experienced moist desquamation in the boost field at the end of treatment. Average BMI of these patients was 30.4 (range, 17.8-50.7). BMI greater than 30 was associated with more depth reduction by repositioning and increased risk of moist desquamation. Conclusions: The lateral decubitus position allows for a decrease in the distance from the skin to the target volume depth, improving electron coverage of the tumor bed while reducing skin entrance dose. This is a well-tolerated regimen for a patient population with a high BMI or deep tumor location.