Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Male”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Survival after Radiofrequency Ablation in 122 Patients with Inoperable Colorectal Lung Metastases

Purpose. To analyze the factors associated with favorable survival in patients with inoperable colorectal lung metastases treated with percutaneous image-guided radiofrequency ablation. Methods. Between 2002 and 2011, a total of 398 metastases were ablated in 122 patients (87 male, median age 68 years, range 29-90 years) at 256 procedures. Percutaneous CT-guided cool-tip radiofrequency ablation was performed under sedation/general anesthesia. Maximum tumor size, number of tumors ablated, number of procedures, concurrent/prior liver ablation, previous liver or lung resection, systemic chemotherapy, disease-free interval from primary resection to lung metastasis, and survival from first ablation were recorded prospectively. Kaplan-Meier analysis was performed, and factors were compared by log rank test. Results. The initial number of metastases ablated was 2.3 (range 1-8); the total number was 3.3 (range 1-15). The maximum tumor diameter was 1.7 (range 0.5-4) cm, and the number of procedures was 2 (range 1-10). The major complication rate was 3.9 %. Overall median and 3-year survival rate were 41 months and 57 %. Survival was better in patients with smaller tumors-a median of 51 months, with 3-year survival of 64 % for tumors 2 cm or smaller versus 31 months and 44 % for tumors 2.1-4 cm (p = 0.08). The number of metastases ablated and whether the tumors were unilateral or bilateral did not affect survival. The presence of treated liver metastases, systemic chemotherapy, or prior lung resection did not affect survival. Conclusion. Three-year survival of 57 % in patients with inoperable colorectal lung metastases is better than would be expected with chemotherapy alone. Patients with inoperable but small-volume colorectal lung metastases should be referred for ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

Introduction: Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients’ case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39–89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1–624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-Lumen Chest Port Infection Rates in Patients with Head and Neck Cancer

PurposeThe aim of this study was to investigate dual-lumen chest port infection rates in patients with head and neck cancer (HNC) compared to those with other malignancies (non-HNC).Materials and MethodsAn IRB-approved retrospective study was performed on 1,094 consecutive chest ports placed over a 2-year period. Patients with poor follow-up (n = 53), no oncologic history (n = 13), or single-lumen ports (n = 183) were excluded yielding a study population of 845 patients. The electronic medical records were queried for demographic information, data regarding ports and infections, and imaging review.ResultsHNC patients experienced more infections (42 vs. 30), an increased infection rate per 1,000 catheter days (0.68 vs. 0.21), and more early infections within 30 days compared to non-HNC patients (10 vs. 6) (p < 0.001, p < 0.001, p = 0.02, respectively). An existing tracheostomy at the time of port placement was associated with infection in the HNC group (p = 0.02) but was not an independent risk factor for infection in the study population overall (p = 0.06). There was a significant difference in age, male gender, and right-sided ports between the HNC and non-HNC groups (p < 0.01, p < 0.001, and p = 0.01), although these were not found to be independent risk factors for infection (p = 0.32, p = 0.76, p = 0.16).ConclusionHNC patients are at increased risk for infection of dual-lumen chest ports placed via a jugular approach compared to patients with other malignancies. Tracheostomy is associated with infection in HNC patients but is not an independent risk factor for infection in the oncologic population as a whole.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Antegrade Varicocele Embolization Via the Testicular Vein in a Patient with Recurrent Varicocele After Surgical Repair

This is a case report of an adolescent male who underwent surgical ligation for a left-sided varicocele that recurred 2 years later. Standard retrograde embolization via the left renal vein was not possible, because there was no connection from the renal vein to the gonadal vein following surgical ligation. The patient was treated via antegrade access of the spermatic vein at the inguinal level with subsequent coil embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients

PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding to a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment

PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min{sup −1} 100 mL{sup −1}); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min{sup −1} 100 mL{sup −1}; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min{sup −1} 100 mL{sup −1}, therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Microwave Ablation of Renal Angiomyolipomas

PurposeTo evaluate the safety and efficacy of US-guided percutaneous microwave (MW) ablation in the treatment of renal angiomyolipoma (AML).Materials and MethodsFrom January 2011 to April 2014, seven patients (5 females and 2 males; mean age 51.4) with 11 renal AMLs (9 sporadic type and 2 tuberous sclerosis associated) with a mean size of 3.4 ± 0.7 cm (range 2.4–4.9 cm) were treated with high-powered, gas-cooled percutaneous MW ablation under US guidance. Tumoral diameter, volume, and CT/MR enhancement were measured on pre-treatment, immediate post-ablation, and delayed post-ablation imaging. Clinical symptoms and creatinine were assessed on follow-up visits.ResultsAll ablations were technically successful and no major complications were encountered. Mean ablation parameters were ablation power of 65 W (range 60–70 W), using 456 mL of hydrodissection fluid per patient, over 4.7 min (range 3–8 min). Immediate post-ablation imaging demonstrated mean tumor diameter and volume decreases of 1.8 % (3.4–3.3 cm) and 1.7 % (27.5–26.3 cm{sup 3}), respectively. Delayed imaging follow-up obtained at a mean interval of 23.1 months (median 17.6; range 9–47) demonstrated mean tumor diameter and volume decreases of 29 % (3.4–2.4 cm) and 47 % (27.5–12.1 cm{sup 3}), respectively. Tumoral enhancement decreased on immediate post-procedure and delayed imaging by CT/MR parameters, indicating decreased tumor vascularity. No patients required additional intervention and no patients experienced spontaneous bleeding post-ablation.ConclusionOur early experience with high-powered, gas-cooled percutaneous MW ablation demonstrates it to be a safe and effective modality to devascularize and decrease the size of renal AMLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median procedural times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon Blocking Technique (BBT) for Superselective Catheterization of Inaccessible Arteries with Conventional and Modified Techniques

PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F catheter via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Shunt Fraction prior to Yttrium-90 Radioembolization Predicts Survival in Patients with Neuroendocrine Liver Metastases: Single-Center Prospective Analysis

ObjectiveTo investigate survival outcomes following radioembolization with Yttrium-90 (Y90) for neuroendocrine tumor liver metastases (NETLMs). This study was designed to assess the efficacy of Y90 radioembolization and to evaluate lung shunt fraction (LSF) as a predictor for survival.MethodsA single-center, prospective study of 44 consecutive patients (median age: 58.5 years, 29.5 % male) diagnosed with pancreatic (52.3 %) or carcinoid (47.7 %) NETLMs from 2006 to 2012 who underwent Y90 radioembolization was performed. Patients’ baseline characteristics, including LSF and median overall survival (OS) from first Y90 radioembolization, were recorded and compared between patients with high (≥10 %) and low (<10 %) LSF. Baseline comparisons were performed using Fisher’s exact tests for categorical and Mann–Whitney U test for continuous variables. Survival was calculated using the Kaplan–Meier method. Univariate (Wilcoxon rank-sum test) and multivariate analyses (Cox Proportional Hazard Model) for risk factor analysis were performed.ResultsThere was no statistically significant difference in age, gender, race, tumor properties, or previous treatments between patients with high (n = 15) and low (n = 29) LSF. The median OS was 27.4 months (95 %CI 12.73–55.23), with 4.77 months (95 %CI 2.87–26.73) for high and 42.77 months (95 %CI 18.47–59.73) for low LSF (p = 0.003). Multivariate analysis identified high LSF (p = 0.001), total serum bilirubin >1.2 mg (p = 0.016), and lack of pretreatment with octreotide (p = 0.01) as independent prognostic factors for poorer survival. Tumor type and total radiation dose did not predict survival.ConclusionsLSF ≥10 %, elevated bilirubin levels, and lack of pretreatment with octreotide were found to be independent prognostic factors for poorer survival in patients with NETLMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arteriolymphatic Fistula: An Unusual Cause of Spontaneous Swelling in the Left Supraclavicular Region

An abnormal fistulous communication between an artery and lymphatic system is a rare occurrence. We report a 38-year-old male presenting with sudden onset, spontaneous, pulsatile swelling in the left supraclavicular region following a recent cardiac catheterisation via right femoral arterial access. On evaluation, he was found to have a femoral arteriolymphatic fistula. He was managed conservatively with ultrasound-guided compression with complete resolution of symptoms at follow-up. This case describes a hitherto unknown complication of percutaneous vascular cannulation presenting in an unusual manner, diagnosed with Doppler Ultrasonography and CT angiography and managed effectively with a non-invasive therapeutic image-guided manoeuvre.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗