Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOSFETs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Poster — Thur Eve — 23: Dose and Position Quality Assurance using the RADPOS System for 4D Radiotherapy with CyberKnife

Introduction: RADPOS 4D dosimetry system consists of a microMOSFET dosimeter combined with an electromagnetic positioning sensor, which allows for performing real-time dose and position measurements simultaneously. In this report the use of RADPOS as an independent quality assurance (QA) tool during CyberKnife 4D radiotherapy treatment is described. In addition to RADPOS, GAFCHROMIC® films were used for simultaneous dose measurement. Methods: RADPOS and films were calibrated in a Solid Water® phantom at 1.5 cm depth, SAD= 80 cm, using 60 mm cone. CT based treatment plan was created for a Solid Water® breast phantom containing metal fiducials and RADPOS probe. Dose calculations were performed using iPlan pencil beam algorithm. Before the treatment delivery, GAFCHROMIC® film was inserted inside the breast phantom, next to the RADPOS probe. Then the phantom was positioned on the chest platform of the QUASAR, to which Synchrony LED optical markers were also attached. Position logging began for RADPOS and the Synchrony tracking system, the QUASAR motion was initiated and the treatment was delivered. Results: RADPOS position measurements very closely matched the LED marker positions recorded by the Synchrony camera tracking system. The RADPOS measured dose was 2.5% higher than the average film measured dose, which is within the experimental uncertainties. Treatment plan calculated dose was 4.1 and 1.6% lower than measured by RADPOS and film, respectively. This is most likely due to the inferior nature of the dose calculation algorithm. Conclusions: Our study demonstrates that RADPOS system is a useful tool for independent QA of CyberKnife treatments.

07 ISOTOPE AND RADIATION SOURCES↗

650V SiC Integrated Power Module for Automotive Inverters

The Delphi team, including CREE/Wolfspeed for SiC power devices, with packaging by Delphi supported by Oak Ridge National Laboratory, and guidance from Volvo and other OEMs resulted in a robust, high performance integrated double-side cooled SiC-based Power Module that meets or exceeds the targets identified by DOE in the original FOA. The double-side cooled packages were designed to be scalable for voltages up to 800V and for phase currents up to 500Arms and that can be paralleled for currents up to 90Arms. These modules were confirmed and demonstrated in a traction drive inverter intended for an inverter for a specific OEM vehicle application and showed improved performance as compared to inverter systems with silicon based IGBTs and Diode with losses 70% lower at lower currents and up to 40% lower at peak current levels. This teaming resulted in a WBG integrated power module to be used in an inverter manufactured in Kokomo, Indiana, which will be manufacturable in volume at a cost that will enable reduced vehicle to cost improved performance, particularly by reducing weight and space-claim for the power electronics, as well as improving reliability overall. The targeted use of this developed power module is for a vehicle traction drive to be manufactured in the CY 2021 timeframe. The direct impact of this project will accelerate commercialization of advanced wide bandgap power semiconductor technology for electrified vehicles of all types, increasing their energy efficiency and marketability. In turn, more efficient and more marketable electrified vehicles will have the overall impact of reducing greenhouse gas emissions and other air pollutants, along with reducing our nation’s dependence on foreign energy sources.

33 ADVANCED PROPULSION SYSTEMS↗

Flexible Large Power Solid State Transformer (FLP-SST)

A large power transformer (LPT) is a major component in the electric power system grid. With the passage of time their reliability in terms of failure and service maintenance has been a big concern. According to a report by EPRI, various agencies have emphasized, and recent events have demonstrated, the critical nature of power transformers in the face of possible high-impact, low-frequency (HILF) events. The HILF events include intentional malicious events (e.g., physical attacks, cyber-attacks, coordinated attacks, electromagnetic pulse weapons, and others), natural disasters (e.g., hurricanes, earthquakes, severe geomagnetic disturbances, etc.), and non-intentional or accidental events such as nuclear power plant accidents. With aging, the line frequency transformers (LFTs) are also prone to failure due to insulation degradation, coolant leakage, mechanical failure, inadequate maintenance, etc. and thus poses a bigger threat to the electrical grid. Moreover, these transformers are custom made to fit the needs at the substation and weighs approximately between 100-400 tons, hence are neither interchangeable nor stored as a spare one. Hence reasonable efforts need to be made regarding the replacement of the LPT with a more feasible technology that does not pose similar issues. The concept of Flexible Large Power Solid-State Transformer (FLPSST) has addressed the aforementioned issues to provide an economical solutions for the failure of LPTs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Organic Direct-Bonded-Copper-Based Rapid Prototyping for Silicon Carbide Power Module Packaging

Silicon carbide (SiC) power devices are playing ever- growing roles in high-power-density power electronics converters by offering benefits such as high voltage rating, fast transients, and high thermal performance. Organic direct-bonded copper (ODBC)-based packaging, due to its ductility and ease of han- dling, allows the possibility of a more flexible layout design that may better tap the potential of SiC benefits. In this work, an ODBC-based prototyping routine is developed that accelerates the iterations of packaging layout design with low cost. The properties of ODBC and its handling are briefly introduced, and tools and fabrication steps are explained. Following this routine, a 1.2-kV SiC half-bridge power module is designed and fabricated with the focus on sub-nanohenry ultra-low loop inductance. Simulation and experimental validation are also conducted.

25 ENERGY STORAGE↗

Thermal Management for Planar Package Power Electronics (CRADA Final Report)

The National Renewable Energy Laboratory (NREL) and John Deere Electronic Solutions (JDES) collaborated to develop and evaluate computer models and simulations related to the thermal performance of semiconductor device packaging for an inverter of an off-road vehicle ("Semiconductor Packaging"). The objective of the research was for NREL and JDES to develop a two or three-dimensional computer-aided design model of the Semiconductor Packaging ("Computer Model") for thermal performance evaluation in a simulation. The project developed computer models of a Semiconductor Package of silicon-carbide semiconductor devices with appropriate thermal dissipation via one or more of the following thermal features: a double-sided planar cooling configuration, an air-cooled configuration, a liquid-cooled configuration for off-road inverter applications in a relevant simulated operating environment. It is noted that surface area and prototype product embodiment consisting of air-cooled and liquid-cooled configurations may and may not be in direct contact with power semiconductor chips. The idea was to explore and develop packaging and thermal management technology for power semiconductors that was most effective in the performance yet had least burden in overall product cost for a given application.

33 ADVANCED PROPULSION SYSTEMS↗

Model Reduction by Generalized Falk Method for Efficient Field-Circuit Simulations

The Generalized Falk Method (GFM) for coordinate transformation, together with two model-reduction strategies based on this method, are presented for efficient coupled field-circuit simulations. Each model-reduction strategy is based on a decision to retain specific linearly-independent vectors, called trial vectors, to construct a vector basis for coordinate transformation. The reduced-order models are guaranteed to be stable and passive since the GFM is a congruence transformation of originally symmetric positive definite systems. We also show that, unlike the Pad´e-via-Lanczos (PVL) method, the GFM does not generate unstable positive poles while reducing the order of circuit problems. Further, the proposed GFM is also faster when compared to methods of the type Lanczos (or Krylov) that are already widely used in circuit simulations for electrothermal and electromagnetic problems. The concept of response participation factors is introduced for the selection of the trial vectors in the proposed model-reduction methods. Further, we present methods to develop simple equivalent circuit networks for the field component of the overall field-circuit system. The implementation of these equivalent circuit networks in circuit simulators is discussed. With the proposed model-reduction strategies, significant improvement on the efficiency of the generalized Falk method is illustrated for coupled field-circuit problems.

42 ENGINEERING↗

Stacking Faults Originating from Star-Defects in 4H-SiC

Intense efforts are currently in progress to study various sources of basal plane dislocations (BPDs) in SiC epitaxial layers. BPDs can generate Shockley-type stacking faults (SSFs) in SiC epitaxial layers, which have been shown to be associated with the degradation of power devices. This study shows that the star-shaped defect can be a source of several BPDs in the epitaxial layer. We investigate the complex microstructure of the star defect, the generation of BPDs, and expansion of SSFs using various complementary microscopy and optical techniques. We show direct evidence that star-defects can be a nucleation point of single-SSFs that can expand at the core of the defect. Newly found secondary dislocation arrays extending over a few centimeters away are found to be emanating from the primary arms of the star defect. The presence of such dislocation walls and the expansion of single-SSFs will affect the yield of numerous die on a wafer. Further understanding of the formation mechanism of stacking faults generated from star-defects as provided in this study helps understand their effect on SiC-based devices, which is crucial to assess device reliability.

36 MATERIALS SCIENCE↗

Improving Heat Conduction of Insulated Metal Substrate with Thermal Pyrolytic Graphite Core for SiC Power Module Packaging

TPG-core IMS concept was jointly explored in this study. Integrating high thermally conductive TPG graphite core into IMS is expected to simultaneously achieve high thermal conductivity from TPG and electrical functionalities from IMS. Nearly 2x thermal conductivity and 30% weight saving was demonstrated on TPG-core IMS compared to conventional Cu-core IMS. Significant junction temperature reduction (11°C) in steady state and power cycling was revealed by the thermal analysis as the result of improved thermal spreading in plane and through the thickness. The study also proved the manufacturability and compatibility of this TPG-core IMS structure to the existing IMS production and power module assembling. Finally, the integration of TPG and IMS paves a new packaging route to increase heat load, improve reliability, simplify module design and reduce assembling cost and number of steps.

36 MATERIALS SCIENCE↗

Low dose failures of hardened DC-DC power converters

Box-level total dose testing of the FOG (Fiber Optic Gyro) by IXSEA at ESA's GammabeamFacility were abruptly terminated at 8krad (Si) due to catastrophic failure (complete shutdown). This was unexpected because all components within the gyro were supposedly radiation tolerant. Further testing showed that the components responsible for the failure were two DC-DC converters, manufactured by Interpoint, that stopped regulating shortly before shutdown. This paper summarizes diagnostic test results for the converters to determine the underlying cause of the unexpected failure at low levels of radiation.

Interpoint Rad-hard DC-DC power converter TC4426 M↗

Silicon Carbide Power Devices and Integrated Circuits

An overview of the NASA NEPP Program Silicon Carbide Power Device subtask is given, including the current task roadmap, partnerships, and future plans. Included are the Agency-wide efforts to promote development of single-event effect hardened SiC power devices for space applications.

single-event gate rupture (SEGR)↗

Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter

The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active natural clamped converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic cancelling effect, and DC-link capacitor placement. The loop inductance of the designed busbar is verified with simulation, impedance measurements and converter experiment. The results can match with each other and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.

SiC MOSFET↗

NASA Engineering and Safety Center Technical Bulletins 2007-2023

An NESC Technical Bulletin captures critical knowledge in the form of new engineering information or best practices in a one-page format that have resulted from NESC independent testing, analysis, and assessments. This document contains all NESC Technical Bulletins from 2007 through 2023.

additive manufacturing, battery, braycote, capacit↗

X-57 Maxwell High Lift Motor Controller Electromagnetic Interference Test Results

During research and development for NASA’s X-57 Maxwell all-electric aircraft project, the efficiency and power density requirements of its electric propulsion subsystem components were met, but aspects of integrating its powertrain subsystems proved problematic. Electromagnetic interference (EMI) from the cruise motor controller (CMC) was a significant challenge for the project. This problem was exacerbated by the lack of EMI requirements imposed on subsystem powertrain components. This report presents the results of EMI testing of the X-57 high lift motor controller (HLMC) at the NASA Glenn Research Center’s EMI Laboratory. For reference, the conducted emissions are compared to DO–160G and MIL–STD–61G conducted emissions limits. After the EMI test, mitigation of the conducted emissions using lightweight EMI chokes produced at NASA Glenn was evaluated using the Fast Fourier Transform (FFT) capability of an oscilloscope in the hardware development laboratory. This process can contribute to the rapid prototyping of electric powertrain components and EMI filters and improve the likelihood of successful EMI qualification at the component and system levels.

Silicon carbide↗

RISE/FALL TIME ENHANCEMENT OF THE SPALLATION NEUTRON SOURCE LINAC LEBT CHOPPER SYSTEM

The Spallation Neutron Source (SNS) Linac Low Energy Beam Transport (LEBT) chopper system provides fast chopping of the H- ion beam in the LEBT structure. Four identical pulsed power supplies (pulsers) create a series of 2.5 kV pulses to the four deflection electrodes floating on the focusing voltage of -50 kV. Each pulser is connected to the electrode through the network which consists of high voltage (HV) cables, a blocking capacitor, HV feed-through connectors, current-limiting resistors and transient voltage suppressors. Effective beam chopping requires minimal rise/fall time of the rectangular HV pulses on the load. In the present configuration these values are approximately 100 ns. Methods of reducing rise/fall time on the LEBT electrodes are discussed. Results of simulation and comparative measurements of the original and upgraded system on the test stand are presented. Furthermore, the effect of these changes on reliability degradation caused by arcing in the LEBT structure is discussed.

LEBT chopper↗