Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METASTASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Restricted mobility of specific functional groups reduces anti-cancer drug activity in healthy cells

Here, the most common cancer treatments currently available are radio- and chemo-therapy. These therapies have, however, drawbacks, such as, the reduction in quality of life and the low efficiency of radiotherapy in cases of multiple metastases. To lessen these effects, we have encapsulated an anti-cancer drug into a biocompatible matrix. In-vitro assays indicate that this bio-nanocomposite is able to interact and cause morphological changes in cancer cells. Meanwhile, no alterations were observed in monocytes and fibroblasts, indicating that this system might carry the drug in living organisms with reduced clearance rate and toxicity. X-rays and neutrons were used to investigate the carrier structure, as well as to assess the drug mobility within the bio-nanocomposite. In conclusion, from these unique data we show that partial mobility restriction of active groups of the drug molecule suggests why this carrier design is potentially safer to healthy cells.

59 BASIC BIOLOGICAL SCIENCES↗

Prostate cancer invasion and metastasis: Insights from mining genomic data

Prostate cancer (PCa) is the second most commonly diagnosed malignancy in men in the Western world and the second leading cause of cancer-related deaths among men worldwide. Although most cancers have the potential to metastasize under appropriate conditions, PCa favors the skeleton as a primary site of metastasis, suggesting that the bone microenvironment is conducive to its growth. PCa metastasis proceeds through a complex series of molecular events that include angiogenesis at the site of the original tumor, local migration within the primary site, intravasation into the blood stream, survival within the circulation, extravasation of the tumor cells to the target organ and colonization of those cells within the new site. In turn, each one of these steps involves a complicated chain of events that utilize multiple protein–protein interactions, protein signaling cascades and transcriptional changes. Despite the urgent need to improve current biomarkers for diagnosis, prognosis and drug resistance, advances have been slow. Global gene expression methods such as gene microarrays and RNA sequencing enable the study of thousands of genes simultaneously and allow scientists to examine molecular pathways of cancer pathogenesis. In this review, we summarize the current literature that explored high-throughput transcriptome analysis toward the advancement of biomarker discovery for PCa. Novel biomarkers are strongly needed to enable more accurate detection of PCa, improve prediction of tumor aggressiveness and facilitate the discovery of new therapeutic targets for tailored medicine. Furthermore, promising molecular markers identified from gene expression profiling studies include HPN, CLU1, WT1, WNT5A, AURKA and SPARC.

59 BASIC BIOLOGICAL SCIENCES↗

Large-scale deep learning for metastasis detection in pathology reports

Objectives No existing algorithm can reliably identify metastasis from pathology reports across multiple cancer types and the entire US population. In this study, we develop a deep learning model that automatically detects patients with metastatic cancer by using pathology reports from many laboratories and of multiple cancer types. Materials and Methods We use 60 471 unstructured pathology reports from 4 Surveillance, Epidemiology, and End Results (SEER) registries. The reports were coded into 1 of 3 labels: metastasis negative, metastases positive, or metastasis undetermined. We utilize a task-specific deep neural network trained from scratch and compare its performance with a widely used large language model (LLM). Results Our deep learning architecture trained on task-specific data outperforms a general-purpose LLM, with a recall of 0.894 compared to 0.824. We quantified model uncertainty and used it to defer reports for human review. We found that retaining 72.9% of reports increased recall from 0.894 to 0.969. Discussion A smaller deep learning architecture trained on task-specific data outperforms a general LLM. Equally critical to model performance is the incorporation of uncertainty quantification, achieved here through an abstention mechanism. Conclusions This study’s finding demonstrate the feasibility of developing algorithms to automatically identify metastatic cancer cases from unstructured pathology reports.

machine learning↗

Improved age- and gender-specific radiation risk models applied on cohorts of Swedish patients

The aim of this study is to implement lifetime attributable risk (LAR) predictions for radiation induced cancers for Swedish cohorts of patients of various age and sex, undergoing diagnostic investigations by nuclear medicine methods. Methods: Calculations are performed on Swedish groups of patients with Paget's disease and with bone metastases from prostatic cancer and diagnosed with bone scintigraphy with an administration of 500 MBq 99m Tc-phosphonate. Results: The inclusion of patient survival rates into the calculations lowers the induced radiation cancer risk, as it takes into account that cohorts of patients have shorter predicted survival times than the general population. Conclusion: LAR estimations could be valuable for referring physicians, nuclear medicine physicians, nurses, medical physicists, radiologists, and oncologists and as well as ethical committees for risk estimates for specific subgroups of patients. Caution is however advised with respect to application of LAR predictions to individuals (because of individual sensitivities, circumstances, etc.).

61 RADIATION PROTECTION AND DOSIMETRY↗

USTUR Whole Body Case 0262: 33-y Follow-up of PuO2 In A Skin Wound and Associated Axillary Node

This whole body donation case (USTUR Registrant) involved two suspected plutonium oxide (Pu) inhalation intakes, each indicated by a measurable Pu alpha activity in a single urine sample, followed about 1.5 y later by a puncture wound to the thumb while working in a Pu glovebox. The study is concerned with modeling simultaneously the biokinetics of deposition and retention in the respiratory tract and at the wound site; and the biokinetics of Pu subsequently transferred to other body organs, until the donor's death. Urine samples taken after the wound incident had readily measurable Pu alpha activity over the next 14 y, before dropping below the minimum detectable excretion rate (<0.4 mBq per day). The Registrant died about 33 y after the wound intake, at the age of 71, from hepatocellular carcinoma with extensive metastases. At autopsy, all major soft tissue organs were harvested for analysis of their Pu-238, Pu-239+240 and Am-241 content. The amount of Pu-239+240 retained at the wound site was 68 ± 7 Bq (1 SD), measured by low-energy planar Ge spectrometry. A further 56.0 ± 1.2 Bq was retained in an associated axillary lymph node, measured by radiochemistry. Simultaneous mathematical analysis (modelling) of all in vivo urinary excretion data, together with the measured lung, thoracic lymph node, wound, axillary lymph node and systemic tissue contents at death, yielded estimated intake amounts of 757 and 1504 Bq, respectively, for the first and second inhalation incidents, and 204 Bq for the total wound intake. The inhaled Pu material was highly insoluble, with an estimated long-term absorption rate from the lungs of 2 E-5 per day. The Pu material deposited at the wound site was mixed: 14% was rapidly absorbed, 49% was absorbed at the rate of about 6E-5 per day, and the remainder ( 37%) was absorbed extremely slowly (at the rate of about 5E-6 per day). Thus, it was estimated that only 40% of the Pu initially deposited in the wound had been absorbed systemically over the 33-y period until the donor's death. The biokinetic modelling also indicated that, in this individual case, some of the parameter values (rate constants) incorporated in the ICRP Publication 67 Pu model were up to a factor of 2 different from ICRP's recommended values (for reference man).

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods to Track Effective Doses from Airborne Radioactive Emissions for Compliance with 40 CFR 61, SUBPART H

US Department of Energy national laboratories can play an integral role in not only the advancement of science but also in the treatment of various medical conditions through research and development activities conducted at radioisotope production facilities. Here, a project has been underway at Oak Ridge National Laboratory since 2016 whose mission is to produce and supply the radioisotope 227 Ac, which is used in a radiopharmaceutical developed to treat certain types of prostate cancer and bone metastases. Production activities result in the environmental release of airborne radioactive emissions, which are governed by Clean Air Act regulations described in 40 CFR Part 61, Subpart H. Stack 3039, the source that emits radioactive effluents from 227 Ac production, is subject to additional requirements outlined in American National Standards Institute (ANSI) N13.1-1969 due to its grandfathered status. Radioactive emissions are limited to levels below those that would cause annual compliance dose standards for members of the public to be exceeded and stack 3039 to lose its grandfathered status. To allow for maximum production of 227 Ac without exceeding relevant dose limits, monthly tracking of project emissions and resulting CAP88-PC modeled effective doses to a maximally exposed individual have been implemented. Four years of tracking data were compiled and analyzed to identify additional methods that could be used to estimate project doses more frequently, potentially further optimizing 227 Ac production while maintaining compliance with applicable regulations.

atmospheric emissions↗

A noninvasive eye fixation monitoring system for CyberKnife radiotherapy of choroidal and orbital tumors

A new noninvasive monitoring system for fixing the eye has been developed to treat orbital and choroidal tumors with CyberKnife-based radiotherapy. This device monitors the eye during CT/MRI scanning and during treatment. The results of this study demonstrate the feasibility of the fixation light system for CyberKnife-based treatments of orbital and choroidal tumors and supports the idea that larger choroidal melanomas and choroidal metastases could be treated with CyberKnife without implanting fiducial markers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-381: Radio-Dynamic Therapy (RDT) for the Treatment of Late-Stage Cancers

Purpose: Photo-dynamic therapy (PDT) is an effective treatment modality because of the preferential absorption of photosensitizing agent in tumor cells than in surrounding normal tissues. A limitation of PDT for cancer therapy is the finite penetration of laser light to activate the targeting agent in deep-seated tumors. Radio-dynamic therapy (RDT) is designed to overcome this problem by the combination of high-energy (up to 45MV) photon beams and photo/radio-sensitizers. This work investigates the feasibility of PDT for late-stage cancer patients who are no longer respond to conventional therapies available. Methods: The high-energy photon beams are generated using a LA45 RaceTrack Microtron (Top Grade Medical, Beijing, China). The targeting agent investigated is 5- aminolevulinic acid (5-ALA). Both in vitro cell lines and in vivo animal models have been used to investigate the mechanisms of RDT and its therapeutic effects and normal tissue toxicities. Oral 5-ALA (30-60 mg/kg) was administered 4-6 hours before the radiation treatment and the total radiation dose varied between 0.1-4.0Gy in 1-4 fractions. Clinical trials are initiated in China for late-stage cancer patients targeting both primary tumors utilizing localized therapies such as 3DCRT/IMRT and metastases using TBI. Results: There is clear correlation between the cell death and the 5-ALA concentration/radiation dose. The therapeutic effect of RDT is demonstrated using an animal model where the volume of parotid tumors for the RT only group continued to grow after 3Gy irradiation while the RDT group showed a complete response with the same radiation dose. The preliminary clinical results showed encouraging clinical outcome. Conclusion: RDT is a novel treatment technique that may be developed into an effective cancer treatment modality. Further studies on the mechanisms of RDT and its potential clinical applications are warranted.

60 APPLIED LIFE SCIENCES↗

Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect quantification of the estimated value in the explanted healthy lung. The proposed preclinical animal model allowed for the study of the explanted lung. As expected, the boron concentration values fell as a result of the application of the preservation protocol required to preserve the lung function. The distribution of the boron concentration retention factor was obtained for healthy lung, with a mean value of 0.46 ± 0.14 consistent with that reported for metastatic colon carcinoma model in rat perfused lung. Considering the human lung model and suitable tumor control probability for lung cancer, a promising average fraction of controlled lesions higher than 85% was obtained even for a low tumor-to-normal boron concentration ratio of 2. Conclusions: This work reports for the first time data supporting the validity of the ovine model as an adequate human surrogate in terms of boron kinetics and uptake in clinically relevant tissues. Collectively, the results and analysis presented would strongly suggest that ex situ whole lung BNCT irradiation is a feasible and highly promising technique that could greatly contribute to the treatment of metastatic lung disease in those patients without extrapulmonary spread, increasing not only the expected overall survival but also the resulting quality of life.

60 APPLIED LIFE SCIENCES↗

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

SU-E-I-81: Targeting of HER2-Expressing Tumors with Dual PET-MR Imaging Probes

Purpose: The detection of human epidermal growth factor receptor type 2 (HER2) expression in malignant tumors provides important information influencing patient management. Radionuclide in vivo imaging of HER2 may permit the detection of HER2 in both primary tumors and metastases by a single noninvasive procedure. Trastuzumab, effective in about 15 % of women with breast cancer, downregulates signalling through the Akt/PI3K and MAPK pathways.These pathways modulate metabolism which can be monitored by positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: The relationship between response of HER2 overexpressing tumours and changes in imaging PET or SPECT and MRI will be examined by a integrated bimodal imaging probe.Small (7 kDa) high-affinity anti-HER2 Affibody molecules and KCCYSL targeting peptide may be suitable tracers for visualization of HER2-expressing tumors. Peptide-conjugated iron oxide nanoparticles (Fe3O4 NPs) as MRI imaging and CB-TE2A as PET imaging are integrated into a single synthetic molecule in the HER2 positive cancer. Results: One of targeted contrast bimodal imaging probe agents was synthesized and evaluated to target HER2-expressing tumors in a HER2 positive rat model. We will report the newest results regarding the development of bimodal imaging probes. Conclusion: The preliminary results of the bimodal imaging probe presents high correlation of MRI signal and PET imaging intensity in vivo. This unique feature can hardly be obtained by single model contrast agents. It is envisioned that this bimodal agents can hold great potential for accurate detection of HER2-expressing tumors which are critical for clinical management of the disease.

60 APPLIED LIFE SCIENCES↗

SU-E-T-609: Perturbation Effects of Pedicle Screws On Radiotherapy Dose Distributions

Purpose: Radiation therapy in conjunction with surgical implant fixation is a common combined treatment in case of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced (CFR) PEEK material has been recently introduced for production of intramedullary screws and plates. Gold powder can be added to the CFR-PEEK material in order to enhance visibility of the screws during intraoperative imaging procedures. In this work, we investigated the perturbation effects of the pedicle screws made of CFR-PEEK, CFR-PEEK with added gold powder (CFR-PEEK-AU) and Titanium (Ti) on radiotherapy dose distributions. Methods: Monte Carlo (MC) simulations were performed using the EGSnrc code package for 6MV beams with 10×10 fields at SSD=100cm. By means of MC simulations, dose distributions around titanium, CFR- PEEK and CFR-PEEK-AU screws (manufactured by Carbo-Fix Orthopedics LTD, Israel) placed in a water phantom were calculated. The screw axis was either parallel or perpendicular to the beam axis. Dose perturbation (relative to dose in homogeneous water phantom) was assessed. Results: Maximum overdose due to backscatter was 10% for the Ti screws, 5% for the CFR-PEEK-AU screws and effectively zero for the CFR-PEEK screws. Maximum underdose due to attenuation was 25% for the Ti screws, 15% for the CFR-PEEK-AU screws and 5% for the CFR-PEEK screws. Conclusion: Titanium screws introduce the largest distortion on the radiation dose distribution. The gold powder added to the CFR-PEEK material improves visibility at the cost of increased dose perturbation. CFR-PEEK screws caused minimal alteration on the dose distribution. This can decrease possible over and underdose of adjacent tissue and thus favorably influence treatment efficiency. The use of such implants has potential clinical advantage in the treatment of neoplastic bone disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-A-BRD-00: Current Trends in Y90-Microsphere Therapy: Delivery and Dosimetry

Yttrium-90 (Y90) microsphere therapy, a form of radiation therapy, is an increasingly popular option for care of patients with liver metastases or unresectable hepatocellular carcinoma. The therapy directly delivers Y90 microspheres via the hepatic artery to disease sites. Following delivery, a vast majority of microspheres preferentially lodge in the capillary vessels due to their embolic size and targeted trans-arterial delivery – depositing up to 90% of its energy in the first 5 mm of tissue. There have been a number of advances in tomographic imaging within both interventional radiology and nuclear medicine that has advanced therapy planning techniques. Quantitative imaging of Y90 microsphere distribution post-therapy has also seen innovations that have led to improvements in tumor dosimetry and characterization of tumor response. A review of current trends and recent innovation in Y90 microsphere therapies will be presented. Learning Objectives: To present the imaging requirements for Y90 microsphere therapy planning To explain the standard dosimetry models used in Y90 microsphere therapy planning To report on advances in imaging for therapy planning and posttherapy assessment of tumor dosimetry and response.

60 APPLIED LIFE SCIENCES↗

MO-A-BRD-01: Clinical Perspective

Yttrium-90 (Y90) microsphere therapy, a form of radiation therapy, is an increasingly popular option for care of patients with liver metastases or unresectable hepatocellular carcinoma. The therapy directly delivers Y90 microspheres via the hepatic artery to disease sites. Following delivery, a vast majority of microspheres preferentially lodge in the capillary vessels due to their embolic size and targeted trans-arterial delivery – depositing up to 90% of its energy in the first 5 mm of tissue. There have been a number of advances in tomographic imaging within both interventional radiology and nuclear medicine that has advanced therapy planning techniques. Quantitative imaging of Y90 microsphere distribution post-therapy has also seen innovations that have led to improvements in tumor dosimetry and characterization of tumor response. A review of current trends and recent innovation in Y90 microsphere therapies will be presented. Learning Objectives: To present the imaging requirements for Y90 microsphere therapy planning To explain the standard dosimetry models used in Y90 microsphere therapy planning To report on advances in imaging for therapy planning and posttherapy assessment of tumor dosimetry and response.

60 APPLIED LIFE SCIENCES↗

TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

TU-B-210-01: MRg HIFU - Bone and Soft Tissue Tumor Ablation

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom

Purpose: Ra-223 therapy of prostate cancer bone metastases is being used to treat patients routinely. However, the absorbed dose distribution at the macroscopic and microscopic scales remains elusive, due to the inability to image the small activities injected. Accurate activity quantification through imaging is essential to calculate the absorbed dose in organs and sub-units in radiopharmaceutical therapy, enabling personalized absorbed dose-based treatment planning methodologies and more effective and optimal treatments. Methods: A 22 cm diameter by 20 cm long cylindrical phantom, containing a 3.52 cm diameter sphere, was used. A total of 2.01 MBq of Ra-223 was placed in the phantom with 177.6 kBq in the sphere. Images were acquired on a dual-head Siemens Symbia T16 gamma camera using three 20% full-width energy windows and centered at 84, 154, and 269 keV (120 projections, 360° rotation, 45 s per view). We have implemented reconstruction of Ra-223 SPECT projections using OS-EM (up to 20 iterations of 10 subsets) with compensation for attenuation using CT-based attenuation maps, collimator-detector response (CDR) (including septal penetration, scatter and Pb x-ray modeling), and scatter in the patient using the effective source scatter estimation (ESSE) method. The CDR functions and scatter kernels required for ESSE were computed using the SIMIND MC simulation code. All Ra-223 photon emissions as well as gamma rays from the daughters Rn-219 and Bi-211 were modeled. Results: The sensitivity of the camera in the three combined windows was 107.3 cps/MBq. The visual quality of the SPECT images was reasonably good and the activity in the sphere was 27% smaller than the true activity. This underestimation is likely due to partial volume effect. Conclusion: Absolute quantitative Ra-223 SPECT imaging is achievable with careful attention to compensate for image degrading factors and system calibration.

60 APPLIED LIFE SCIENCES↗