Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Magnetic field extraction of trap-based electron beams using a high-permeability grid

A method to form high quality electrostatically guided lepton beams is explored. Test electron beams are extracted from tailored plasmas confined in a Penning-Malmberg trap. The particles are then extracted from the confining axial magnetic field by passing them through a high magnetic permeability grid with radial tines (a so-called “magnetic spider”). An Einzel lens is used to focus and analyze the beam properties. Numerical simulations are used to model non-adiabatic effects due to the spider, and the predictions are compared with the experimental results. Improvements in beam quality are discussed relative to the use of a hole in a high permeability shield (i.e., in lieu of the spider), and areas for further improvement are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection efficiency of microchannel plates for e{sup −} and π{sup −} in the momentum range from 17.5 to 345 MeV/c

High-energy e{sup –} and π{sup –} were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5–300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172–345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter’s magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved magnetometer uses toroidal gating coil

Improved magnetometer employs a cylindrical, high permeability magnetic core with a toroidal gating coil and a solenoid pickup coil. Flux interaction can be reduced by electrostatically shielding the pickup coil from the gating coil. The magnetometer principle can be applied to navigation devices.

Source record↗

A study of heavy-heavy nuclear reactions

Calculations are presented for the reaction products in high energy collisions and of the atmospheric transport of particles such as protons, neutrons and other nucleons. The magnetic moments of charmed baryons are examined. Total cross sections which are required for cosmic heavy ion transport and shielding studies are also examined.

Khandelwal, G. S.↗

The electric field and global electrodynamics of the magnetosphere

The conception of the electrodynamics of the quiet-time magnetosphere obtained during the last four years of magnetospheric study is presented. Current understandings of the open magnetosphere, convective plasma flows in the plasma sheet, the shielding of the inner magnetosphere from the convective magnetospheric electric field, the space charge produced when injected electrons drift towards dawn and injected ions drift towards dusk, the disruption of the flow of the Birkeland current by plasma instabilities and the shielding of the convective electric field by the dayside magnetopause are discussed. Attention is also given to changes of magnetic field line topology magnetic storms and substorms. Unresolved questions and new tools which may play a role in the further understanding of magnetospheric electrodynamics and the role of the magnetospheric electric field are presented.

Stern, D. P.↗

Reduced to Pole Long-wavelength Magnetic Anomalies of Africa and Europe

To facilitate analysis of the tectonic framework for Africa, Europe and adjacent marine areas, MAGSAT scalar anomaly data are differentially reduced to the pole and compared to regional geologic information and geophysical data including surface free-air gravity anomaly data upward continued to satellite elevation (350 km) on a spherical Earth. Comparative analysis shows magnetic anomalies correspond with both ancient as well as more recent Cenozoic structural features. Anomalies associated with ancient structures are primarily caused by intra-crustal lithologic variations such as the crustal disturbance associated with the Bangui anomaly in west-central Africa. Anomalies correlative with Cenozoic tectonic elements appear to be related to Curie isotherm perturbations. A possible example of the latter is the well-defined trend of magnetic minima that characterize the Alpine orogenic belt from the Atlas mountains to Eurasia. In contrast, a well-defined magnetic satellite minimum extends across the stable craton from Finland to the Ural mountains. Prominent magnetic maxima characterize the Arabian plate, Iceland, the Kursk region of the central Russian uplift, and generally the Precambrian shields of Africa.

Hinze, W. J.↗

Reduced to pole long-wavelength magnetic anomalies of Africa and Europe

To facilitate analysis of the tectonic framework for Africa, Europe and adjacent marine areas, MAGSAT scalar anomaly data are differentially reduced to the pole and compared to regional geologic information and geophysical data including surface free-air gravity anomaly data upward continued to satellite elevation (350 km) on a spherical Earth. Comparative analysis shows magnetic anomalies correspond with both ancient as well as more recent Cenozoic structural features. Anomalies associated with ancient structures are primarily caused by intra-crustal lithologic variations such as the crustal disturbance associated with the Bangui anomaly in west-central Africa. Anomalies correlative with Cenozoic tectonic elements appear to be related to Curie isotherm perturbations. A possible example of the latter is the well-defined trend of magnetic minima that characterize the Alphine orogenic belt from the Atlas mountains to Eurasia. In contrast, a well-defined magnetic satellite minimum extends across the stable craton from Finland to the Ural mountains. Prominent magnetic maxima characterize the Arabian plate, Iceland, the Kursk region of the central Russian uplift, and generally the Precambrian shields of Africa.

Olivier, R.↗

MEMS Microshutter Arrays for James Webb Space Telescope

MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use as an aperture array for a Near-Infrared Spectrometer (NirSpec). The instruments will be carried on the James Webb Space Telescope (JWST), the next generation of space telescope after Hubble Space Telescope retires. The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast, Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. Light shields are made on to each shutter for light leak prevention so to enhance optical contrast, Shutters are actuated magnetically, latched and addressed electrostatically. The shutter arrays are fabricated using MEMS technologies.

Li, Mary J.↗

Transparent and Electrically Conductive Carbon Nanotube-Polymer Nanocomposite Materials for Electrostatic Charge Dissipation

In recent years, nanocomposite materials have been extensively studied because of their superior electrical, magnetic, and optical properties and large number of possible applications that range from nano-electronics, specialty coatings, electromagnetic shielding, and drug delivery. The aim of the present work is to study the electrical and optical properties of carbon nanotube(CNT)-polymer nanocomposite materials for electrostatic charge dissipation. Single and multi-wall carbon nanotubes were grown by catalytic chemical vapor deposition (CCVD) on metal/metal oxide catalytic systems using acetylene or other hydrocarbon feedstocks. After the purification process, in which amorphous carbon and non-carbon impurities were removed, the nanotubes were functionalized with carboxylic acid groups in order to achieve a good dispersion in water and various other solvents. The carbon nanostructures were analyzed, both before and after functionalization by several analytical techniques, including microscopy, Raman spectroscopy, and X-Ray photoelectron spectroscopy. Solvent dispersed nanotubes were mixed (1 to 7 wt %) into acrylic polymers by sonication and allowed to dry into 25 micron thick films. The electrical and optical properties of the films were analyzed as a function of the nanotubes' concentration. A reduction in electrical resistivity, up to six orders of magnitude, was measured as the nanotubes' concentration in the polymeric films increased, while optical transparency remained 85 % or higher relative to acrylic films without nanotubes.

Dervishi, E.↗

Electrostatic Microshutter Arrays

Based on the Microshutter Array (MSA) subsystems developed at NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST), Next Generation Microshutter Array (NGMSA) has been developed to be used as multi-object selectors for future telescopes in space applications. Microshutter arrays function as transmission devices. Selected shutters fully open at 90 degrees permitting income light going through, while the rest of shutters keep closed. The programmable microshutter open and close make the device perform as a multi object selector that can be used on space telescopes. Utilizing a multi object selector, the telescope efficiency can be increased to 100 times or more. Like JWST MSAs, NGMSA features torsion hinges, light shields, front and back electrodes for shutter actuation, latch, and closing. The difference is that JWST MSA utilized the magnetic actuation while NGMSA the electrostatic actuation.

Micro-electro-mechanical-system (MEMS)↗

Adult head-sized coil-based low-field MRI

An ultra-low field pre-pulse Magnetic Resonance Imaging (PMRI) system for a head includes RF coils defining a bore for head access, a pre-pulse coil outside the RF coils, and a coil assembly including a main magnetic field coil and gradient coils outside the pre-pulse coil. The PMRI system includes a first cylindrical shield concentric with the RF coils and made from conductive materials. The first cylindrical shield partially encloses the RF coils and inside the pre-pulse coil for shielding the RF coils from environmental electromagnetic disturbances.

Schiff, Steven J.↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200A,<2500V) through a gas column (~10cm diameter, 2m length) and ejecting the heatedgas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2eV) but needs to be stable for long test times (up to 30min) at high power (< 20MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion usingthese sensors.

Kink instability↗

Improving the Fermilab Booster Notching Efficiency, Beam Losses and Radiation Levels

A fast vertical 1.08-m long kicker (notcher) located in the Fermilab Booster Long-05 straight section is currently used to remove 3 out of 84 circulating bunches after injection to generate an abort gap. With the maximum magnetic field of 72.5 Gauss, it removes only 87% of the 3-bunch intensity at 400 MeV, with 75% loss on pole tips of the focusing Booster magnets, 11% on the Long-06 collimators, and 1% in the rest of the ring. We propose to improve the notching efficiency and reduce beam loss in the Booster by using three horizontal kickers in the Long-12 section. STRUCT calculations show that using horizontal notchers, one can remove up to 96% of the 3-bunch intensity at 400-700 MeV, directing 95% of it to a new beam dump at the Long-13 section. This fully decouples notching and collimation. The beam dump absorbs most of the impinging proton energy in its jaws. The latter are encapsulated into an appropriate radiation shielding that reduces impact on the machine components, personnel and environment to the tolerable levels. MARS simulations show that corresponding prompt and residual radiation levels can be reduced ten times compared to the current ones.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200 A,<2500 V) through a gas column (~6 cm diameter, 2 m length) and ejecting the heated gas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2 eV) but needs to be stable for long test times (up to 30 min) at high power (< 20 MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion using these sensors.

Kink instability↗

SU-GG-T-49: Real Time Dose Verification for Novel Shielded Balloon Brachytherapy

Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Remote Handling and Maintenance in the Facility for Rare Isotope Beams

Michigan State University (MSU) in East Lansing, MI was selected by the U.S. Department of Energy (DOE) to design and establish a Facility for Rare Isotope Beams (FRIB), a cutting-edge research facility to advance the understanding of rare nuclear isotopes and the evolution of the cosmos. The research conducted at the FRIB will involve experimentation with intense beams of rare isotopes within a well-shielded target cell that will result in activation and contamination of components. The target cell is initially hands-on accessible after shutdown and a brief cool-down period. Personnel are expected to have hands-on access to the tops of shielded component modules with the activated in-beam sections suspended underneath. The modules are carefully designed to include steel shielding for protecting personnel during these hand-on operations. However, as the facility has greater levels of activation and contamination, a bridge mounted servomaniputor may be added to the cell, to perform the disconnecting of services to the component assemblies. Dexterous remote handling and exchange of the modularized activated components is completed at a shielded window workstation with a pair of master-slave manipulators. The primary components requiring exchange or maintenance are the production target, the beam wedge filter, the beam dump, and the beam focusing and bending magnets. This paper provides an overview of the FRIB Target Facility remote handling and maintenance design requirements, concepts, and techniques.

36 MATERIALS SCIENCE↗

Structural, Electrical, and Magnetic Properties of Ferrite-Reinforced PANI Composites

A Y-type hexagonal ferrite with chemical composition CaBaCo{sub 2}In{sub 0.5}Fe{sub 11.5}O{sub 22} was prepared by a sol-gel auto combustion technique. Y-ferrite/PANI nanocomposites were prepared by in situ polymerization of PANI with general formula CaBaCo{sub 2}In{sub 0.5}Fe{sub 11.5}O{sub 22} (1-x) + PANI (x) (x = 0.30, 0.50, 0.8, and 1) with nomenclature CF1, CF2, CF3, and P respectively. The samples were characterized by X-ray diffraction (XRD) and electrical and magnetic measurements. X-ray diffraction revealed that Y-type ferrite was successfully prepared in a single phase form. DC resistivity increases with increasing ferrite filler in nanocomposites due to large resistive behavior of ferrite in conducting polymer matrix. The dielectric constant, dielectric loss, and AC conductivity decreases with the increase of ferrite content. The dielectric is high due to interfacial polarization at low frequency, and it is low at high frequency following Maxwell-Wagner model. The coercivity increases with the decrease of ferrite filler content whereas saturation magnetization and remanence decreases which is due to random distribution of ferrite filler particles in PANI matrix. Due to large coercivity and low values of ε′ and ε″, the present samples may be useful in recording media and electromagnetic shielding.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cluster Synthesis and Direct Ordering of Rare-Earth Transition-Metal Nanomagnets

Rare-earth transition-metal (R-TM) alloys show superior permanent magnetic properties in the bulk, but the synthesis and application of R-TM nanoparticles remains a challenge due to the requirement of high-temperature annealing above about 800 degrees C for alloy formation and subsequent crystalline ordering. Here we report a single-step method to produce highly ordered R-TM nanoparticles such as YCo(5) and Y(2)Co(17), without high-temperature thermal annealing, by employing a cluster-deposition system and investigate their structural and magnetic properties. The direct ordering is highly desirable to create and assemble R-TM nanoparticle building blocks for future permanent-magnet and other significant applications.

Balasubramanian, B↗