Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHTNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

New Lightning-Derived Vertical Total Electron Content Data Provide Unique Global Ionospheric Measurements

A newly released, novel ionospheric data set of global gridded vertical total electron content (VTEC) is introduced in this paper. This VTEC data set, provided by Los Alamos National Laboratory (LANL), is derived from very high frequency (VHF; defined as 30–300 MHz) broadband radio-frequency (RF) measurements of lightning made by U.S. Department of Defense sensing systems on board Global Positioning System (GPS) satellites. This paper presents the new data set (LANL VTEC), discusses the errors inherent in VHF TEC estimation due to ionospheric dispersion, and compares the LANL VTEC to two community standard VTEC gridded products: Jet Propulsion Laboratory's Global Ionospheric Model (JPL GIM) and the CEDAR community's Open Madrigal VTEC gridded measurements of L-band GNSS (global navigation satellite systems) TEC. We find that the LANL VTEC data have an offset of 3 TECU from CEDAR Madrigal GNSS VTEC and a full-width-half-maximum (FWHM) of 6 TECU. In comparison, the offset between LANL VTEC and the JPL GIM model is –3 TECU, but with a FWHM of 5 TECU. We also compare to Jason-3 VTEC measurements over the ocean, finding an offset of less than 0.5 TECU and an FWHM of <5 TECU. Because this technique uses a completely different methodology to determine TEC, the sources of errors are distinct from the typical ground-based GNSS L-band (GHz) TEC measurements. Also, because it is derived from RF lightning signals, this data set provides measurements in regions that are not well covered by ground-based GPS measurements, such as over oceans and over central Africa.

79 ASTRONOMY AND ASTROPHYSICS↗

Physical mechanism and numerical simulation of the inception of the lightning upward leader

The upward leader is a key physical process of the leader progression model of lightning shielding. The inception mechanism and criterion of the upward leader need further understanding and clarification. Based on leader discharge theory, this paper proposes the critical electric field intensity of the stable upward leader (CEFISUL) and characterizes it by the valve electric field intensity on the conductor surface, E{sub L}, which is the basis of a new inception criterion for the upward leader. Through numerical simulation under various physical conditions, we verified that E{sub L} is mainly related to the conductor radius, and data fitting yields the mathematical expression of E{sub L}. We further establish a computational model for lightning shielding performance of the transmission lines based on the proposed CEFISUL criterion, which reproduces the shielding failure rate of typical UHV transmission lines. The model-based calculation results agree well with the statistical data from on-site operations, which show the effectiveness and validity of the CEFISUL criterion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure of conducting channel of lightning

The spatial distribution of the plasma density in a lightning channel is studied theoretically. It is shown that the electric-field double layer is formed at the channel boundary. In this case, the electron temperature changes abruptly and ions are accelerated by the electric field of the double layer. The ion momentum flux density is close to the surrounding gas pressure. Cleaning of the channel from heavy particles occurs in particle-exchange processes between the plasma channel and the surrounding air. Hydrogen ions are accumulated inside the expanding channel from the surrounding air, which is enriched by hydrogen-contained molecules. In this case, the plasma channel is unstable and splits to a chain of equidistant bunches of plasma. The hydrogen-enrich bunches burn diffusely after recombination exhibiting the bead lightning behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resistance and internal electric field in cloud-to-ground lightning channel

Cloud-to-ground lightning with six return strokes has been recorded by slitless spectrograph and the system of fast antenna and slow antenna. The physical parameters of the discharge channel have been obtained based on the combination of spectra and synchronous radiated electric field. The resistance and internal electric field of the channel are studied as the focus in this paper. The results show that the resistances per unit length of the lightning channel are in the order of 10{sup −2}–10{sup −1 }Ω/m and the internal electric field strengths are in the order of 10{sup 3 }V/m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal power and heat energy of cloud-to-ground lightning process

A cloud-to-ground lightning flash with nine return strokes has been recorded using a high speed slitless spectrograph and a system composed of a fast antenna and a slow antenna. Based on the spectral data and the synchronous electric field changes that were caused by the lightning, the electrical conductivity, the channel radii, the resistance per unit length, the peak current, the thermal power at the instant of peak current, and the heat energy per unit length during the first 5 μs in the discharge channel have all been calculated. The results indicate that the channel radii have linear relationships with the peak current. The thermal power at the peak current time increases with increasing resistance, but exponential decays with the square of the peak current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

2019 Theoretical Division Lightning Talk Series

All members of the Theoretical (T) Division Community, students, staff members, group leaders, division management and other interested individuals are invited to come and support the following student(s) during their Lightning Talk presentation. The Lightning Talk Series is a forum for T Division students to present information about their current projects.

2019 Theoretical Division Lightning Talk Series↗

The Influence of Carbon Fiber Composite Specimen Design Parameters on Artificial Lightning Strike Current Dissipation and Material Thermal Damage

Previous artificial lightning strike direct effect research has examined a broad range of specimen design parameters. No works have studied how such specimen design parameters and electrical boundary conditions impact the dissipation of electric current flow through individual plies. This article assesses the influence of carbon fiber composite specimen design parameters (design parameters = specimen size, shape, and stacking sequence) and electrical boundary conditions on the dissipation of current and the spread of damage resulting from Joule heating. Thermal-electric finite element (FE) modelling is used and laboratory scale (<1 m long) and aircraft scale (>1 m long) models are generated in which laminated ply current dissipation is predicted, considering a fixed artificial lightning current waveform. The simulation results establish a positive correlation between the current exiting the specimen from a given ply and the amount of thermal damage in that ply. The results also establish that the distance to ground, from the strike location to the zero potential boundary conditions (ground), is the controlling factor which dictates the electric current dissipation in each ply. Significantly, this distance to ground is dependent on each of the specimen shape, dimensions, stacking sequence, and location of ground boundary conditions. Therefore, it is not possible to decouple current dissipation and damage from specimen design and boundary condition setup. However, it is possible to define a specimen size for a given specimen shape, stacking sequence, and waveform which limit the influence of specimen dimensions on the resulting current distribution and damage. For a rectangular specimen design which appears in literature multiple times, as 100 × 150 mm and with a stacking sequence of [45/0/-45/90] 4s , a specimen design of greater than 300 × 200 mm is required to limit the influence of specimen dimensions on current distribution and damage.

36 MATERIALS SCIENCE↗

Ball lightning characteristics

Comparison of frequency of ball lightning observation with ordinary lightning impact points - brightness, size, duration, or color

POINT IMPACT↗

Investigation on Improvements in Lightning Retest Criteria for Spacecraft

Spacecraft are generally protected from a direct strike by launch the vehicle and ground structures, but protocols to evaluate the impact of nearby strikes are not consistent. Often spacecraft rely on the launch vehicle constraints to trigger a retest, but launch vehicles can typically evaluate the impact of a strike within minutes while spacecraft evaluation times can be on the order of hours or even days. For launches at the Kennedy Space Center where lightning activity is among the highest in the United States, this evaluation related delay could be costly with the possibility of missing the launch window altogether. This paper evaluated available data from local lightning measurements systems and computer simulations to predict the coupled effect from various nearby strikes onto a typical payload umbilical. Recommendations are provided to reduce the typical trigger criteria and costly delays.

Models↗

On the VHF Source Retrieval Errors Associated with Lightning Mapping Arrays (LMAs)

This presentation examines in detail the standard retrieval method: that of retrieving the (x, y, z, t) parameters of a lightning VHF point source from multiple ground-based Lightning Mapping Array (LMA) time-of-arrival (TOA) observations. The solution is found by minimizing a chi-squared function via the Levenberg-Marquardt algorithm. The associated forward problem is examined to illustrate the importance of signal-to-noise ratio (SNR). Monte Carlo simulated retrievals are used to assess the benefits of changing various LMA network properties. A generalized retrieval method is also introduced that, in addition to TOA data, uses LMA electric field amplitude measurements to retrieve a transient VHF dipole moment source.

inversion↗

Preliminary Assessment of Detection Efficiency for the Geostationary Lightning Mapper Using Intercomparisons with Ground-Based Systems

As part of the calibration/validation (cal/val) effort for the Geostationary Lightning Mapper (GLM) on GOES-16, we need to assess instrument performance (detection efficiency and accuracy). One major effort is to calculate the detection efficiency of GLM by comparing to multiple ground-based systems. These comparisons will be done pair-wise between GLM and each other source. A complication in this process is that the ground-based systems sense different properties of the lightning signal than does GLM (e.g., RF vs. optical). Also, each system has a different time and space resolution and accuracy. Preliminary results indicate that GLM is performing at or above its specification.

GL↗

Flash Optical Energy from the Geostationary Lightning Mapper

The Geostationary Operational Environmental Satellite - 16 (GOES-16) Geostationary Lightning Mapper (GLM) is evaluated for many months during the Post Launch Product Test (PLPT) phase in order to ensure that optimal products are available for both the operational forecasting and broader scientific research communities. An essential aspect of the PLPT phase is to obtain a benchmark of the GLM lightning optical amplitude, so that any long-term degradation in the nadir-staring GLM camera system can be realized and quantitatively assessed. This work provides a preliminary benchmark over a 60-day period using Provisionally Validated data.

Flash↗

Volcanic lightning and plume behavior reveal evolving hazards during the April 2015 eruption of Calbuco Volcano, Chile

Soon after the onset of an eruption, model forecasts of ash dispersal are used to mitigate the hazards to aircraft, infrastructure, and communities downwind. However, it is a significant challenge to constrain the model inputs during an evolving eruption. Here we demonstrate that volcanic lightning may be used in tandem with satellite detection to recognize and quantify changes in eruption style and intensity. Using the eruption of Calbuco volcano in southern Chile on 22 and 23 April 2015, we investigate rates of umbrella cloud expansion from satellite observations, occurrence of lightning, and mapped characteristics of the fall deposits. Our remote sensing analysis gives a total erupted volume that is within uncertainty of the mapped volume (0.56 ± 0.28 km3 bulk). Furthermore, observations and volcanic plume modeling further suggest that electrical activity was enhanced both by ice formation in the ash clouds >10 km above sea level and development of a low-level charge layer from ground-hugging currents.

58 GEOSCIENCES↗

Probing the D-region ionosphere globally with Earth Networks Total Lightning Network data

An existing technique to use broadband lightning waveforms to probe the D-region ionosphere (60–90 km altitude) is shown to be extendable to a global scale using the Earth Networks Total Lightning Network (ENTLN). This paper demonstrates the technique in detail on a region of the Southeastern United States. This demonstration shows that diurnal D-region height variation and smaller time-scale variations on the order of tens of minutes to hours are evident in the measurement. The technique is then extended to three additional global regions on this same day: Northeastern U.S., India, and Japan. The diurnal behavior between these different regions is compared to a D-region model from the International Reference Ionosphere.

D-region ionosphere↗

The Illumination of Thunderclouds by Lightning: 2. The Effect of GLM Instrument Threshold on Detection and Clustering

Abstract Lightning is measured from space using optical instruments that detect transient changes in the illumination of the cloud top. How much of the flash (if any) is recorded by the instrument depends on the instrument detection threshold. NOAA's Geostationary Lightning Mapper (GLM) employs a dynamic threshold that varies across the imaging array and changes over time. This causes flashes in certain regions and at night to be recorded in greater detail than other flashes, and threshold inconsistencies will impose biases on all levels of GLM data products. In this study, we quantify the impact of the varying GLM threshold on event/group/flash detection, flash clustering, and gridded product generation by imposing artificial thresholds on the event data taken from a thunderstorm with a low instrument threshold (∼0.7 fJ). We find that even modest increases in threshold severely impact event (60% loss by 2 fJ, 90% loss by 10 fJ) and group (25% loss by 2 fJ, 81% loss by 10 fJ) detection by suppressing faint illumination of the cloud top from weak sources and scattering. Flash detection is impacted less by threshold increases (4% loss by 2 fJ), but reductions are still significant at higher thresholds (35% loss by 10 fJ, or 44% if single‐group flashes are removed). Undetected pulses cause individual flashes to be split and severely impact the construction of gridded products. All of these factors complicate the interpretation of GLM data, particularly when trended over time under a changing threshold.

54 ENVIRONMENTAL SCIENCES↗

3D Radio Frequency Mapping and Polarization Observations Show Lightning Flashes Were Ignited by Cosmic‐Ray Showers

Previous 2D radio frequency interferometric observations showed that lightning is commonly started with a positive fast discharge (+FD) before a normal negative leader continues from the origin of the +FD to the ensuing lightning flash. However, the inception and development of the +FD cannot be convincingly explained by existing discharge theories. With our new 3D broadband interferometric mapping and polarization system, we observed that the +FD was sometimes followed by an even faster and more extensive negative discharge (−FD) that propagated backward and overshoot the origin by a few hundred meters, as reported by an earlier 2D study. Surprisingly, the signal polarization, which measures the orientation of the discharge current, systematically slanted from the discharge propagation direction and rotated between the two opposite discharges, showing the +FD and −FD were driven by other storm-independent factors in addition to the storm electric field, or otherwise all would align in the same direction. Assuming a cosmic-ray shower (CRS) piercing through the cloud immediately before the +FD/−FD discharge, we found that their path is consistent with a pre-ionized path by the CRS, and the polarizations for the two opposite discharges are consistent with the respective deflected trajectories of high-energy positrons and electrons in the geomagnetic and an electric field. We further analyzed the more commonly observed +FD and showed that it is consistent with the CRS interpretation, suggesting these flashes in thunderstorms were ignited by cosmic-ray showers.

58 GEOSCIENCES↗

Evaluating the impact of air terminal geometry on lightning intercept efficacy under a strong background electric field

A comparative analysis of the attachment efficacy of sharpened vs blunted air terminals under a strong background DC electric field, similar to conditions found in naturally occurring lightning events, is presented. Testing was conducted using an oil-free, 17-stage, 1.4 MV bipolar Marx generator with a biased discharge plane that emulated the conditions found prior to the lightning return stroke. The biased discharge plane allowed the introduction of a strong DC electric field and subsequent corona formation on a time scale much longer than the brief duration over which the downward leader propagates. Initial observations indicate that despite a higher background electric field at the sharpened terminals, leading to pre-discharge corona formation where none is seen on the blunt terminal, both the sharpened and blunted terminals exhibit similar attachment probabilities during discharge events, with some discharge events attaching to both terminals.

54 ENVIRONMENTAL SCIENCES↗