Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implementation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Medium-scale to large-scale implementation of cyber-physical human experiments in live traffic

Autonomous Vehicles (AVs) such as cars and trucks are being developed and tested as Cyber-Physical Human systems while the technology improves. Before these systems can achieve full autonomy, some serve as tools in the form of adaptive cruise control. The CIRCLES Consortium investigates the potential for AVs to increase fuel efficiency of highway traffic by smoothing “stop-and-go” traffic waves that result from normal human driving behavior in congestion. We have performed an experiment to evaluate the real world effects of implementing this strategy. A medium-scale experiment was performed on I-24 near Nashville, TN in August 2021. This was a precursor to a larger experiment that will take place November 2022. We examine how the human part of the experiment will change as we scale up from an 11 vehicle test (four AVs) to 100 AVs. There are many solutions to problems of the medium-scale experiment that would be inconvenient, complicate the experience, or not be practicable. The medium-scale experiment involved 11 cars of which four had a custom control algorithm installed to be engaged by the driver. The large-scale experiment will have 100 cars, all with custom control algorithm installed to act on traffic when the controller is engaged. We examine key choices made for the medium experiment, and how some will be different for the large experiment. Our experience performing the medium-scale experiment has made it clear that repeating our methods from this smaller one are inefficient or impossible if used for the large-scale experiment and will be improved.

McQuade, Sean T.↗

Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal external radiotherapy and long-term ADT. High-quality implants can be achieved by a trained specialized team at a high-turnover center using transrectal ultrasound-based treatment plans with acceptable morbidity and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single {sup 60}Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of FDG-PET in the Implementation of Involved-Node Radiation Therapy for Hodgkin Lymphoma Patients

Purpose: This study examines the role of {sup 18}F-labeled fluorodeoxyglucose positron emission tomography (FDG-PET) in the implementation of involved-node radiation therapy (INRT) in patients treated for clinical stages (CS) I/II supradiaphragmatic Hodgkin lymphoma (HL). Methods and Material: Patients with untreated CS I/II HL enrolled in the randomized EORTC/LYSA/FIL Intergroup H10 trial and participating in a real-time prospective quality assurance program were prospectively included in this study. Data were electronically obtained from 18 French cancer centers. All patients underwent APET-computed tomography (PET-CT) and a post-chemotherapy planning CT scanning. The pre-chemotherapy gross tumor volume (GTV) and the postchemotherapy clinical target volume (CTV) were first delineated on CT only by the radiation oncologist. The planning PET was then co-registered, and the delineated volumes were jointly analyzed by the radiation oncologist and the nuclear medicine physician. Lymph nodes undetected on CT but FDG-avid were recorded, and the previously determined GTV and CTV were modified according to FDG-PET results. Results: From March 2007 to February 2010, 135 patients were included in the study. PET-CT identified at least 1 additional FDG-avid lymph node in 95 of 135 patients (70.4%; 95% confidence interval [CI]: 61.9%-77.9%) and 1 additional lymph node area in 55 of 135 patients (40.7%; 95% CI: 32.4%-49.5%). The mean increases in the GTV and CTV were 8.8% and 7.1%, respectively. The systematic addition of PET to CT led to a CTV increase in 60% of the patients. Conclusions: Pre-chemotherapy FDG-PET leads to significantly better INRT delineation without necessarily increasing radiation volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic Malignancies

Purpose: Intensity modulated proton therapy (IMPT) can improve dose conformality and better spare normal tissue over passive scattering techniques, but range uncertainties complicate its use, particularly for moving targets. We report our early experience with IMPT for thoracic malignancies in terms of motion analysis and management, plan optimization and robustness, and quality assurance. Methods and Materials: Thirty-four consecutive patients with lung/mediastinal cancers received IMPT to a median 66 Gy(relative biological equivalence [RBE]). All patients were able to undergo definitive radiation therapy. IMPT was used when the treating physician judged that IMPT conferred a dosimetric advantage; all patients had minimal tumor motion (<5 mm) and underwent individualized tumor-motion dose-uncertainty analysis and 4-dimensional (4D) computed tomographic (CT)-based treatment simulation and motion analysis. Plan robustness was optimized by using a worst-case scenario method. All patients had 4D CT repeated simulation during treatment. Results: IMPT produced lower mean lung dose (MLD), lung V{sub 5} and V{sub 20}, heart V{sub 40}, and esophageal V{sub 60} than did IMRT (P<.05) and lower MLD, lung V{sub 20}, and esophageal V{sub 60} than did passive scattering proton therapy (PSPT) (P<.05). D{sub 5} to the gross tumor volume and clinical target volume was higher with IMPT than with intensity modulated radiation therapy or PSPT (P<.05). All cases were analyzed for beam-angle-specific motion, water-equivalent thickness, and robustness. Beam angles were chosen to minimize the effect of respiratory motion and avoid previously treated regions, and the maximum deviation from the nominal dose-volume histogram values was kept at <5% for the target dose and met the normal tissue constraints under a worst-case scenario. Patient-specific quality assurance measurements showed that a median 99% (range, 95% to 100%) of the pixels met the 3% dose/3 mm distance criteria for the γ index. Adaptive replanning was used for 9 patients (26.5%). Conclusions: IMPT using 4D CT-based planning, motion management, and optimization was implemented successfully and met our quality assurance parameters for treating challenging thoracic cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee

Pencil-beam scanning (PBS) proton therapy (PT), particularly intensity modulated PT, represents the latest advanced PT technology for treating cancers, including thoracic malignancies. On the basis of virtual clinical studies, PBS-PT appears to have great potential in its ability to tightly tailor the dose to the target while sparing critical structures, thereby reducing treatment-related toxicities, particularly for tumors in areas with complicated anatomy. However, implementing PBS-PT for moving targets has several additional technical challenges compared with intensity modulated photon radiation therapy or passive scattering PT. Four-dimensional computed tomography–based motion management and robust optimization and evaluation are crucial for minimizing uncertainties associated with beam range and organ motion. Rigorous quality assurance is required to validate dose delivery both before and during the course of treatment. Active motion management (eg, breath hold), beam gating, rescanning, tracking, or adaptive planning may be needed for cases involving significant motion or changes in motion or anatomy over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eulerian finite element implementations of a dislocation density-based continuum model

In Eulerian finite element simulations, the mesh moves relative to the material. After every change of position between the mesh and the material, the state variables are interpolated to the new mesh position, which is referred to as advection. Large strain crystal plasticity models are based on the multiplicative decomposition of the total deformation gradient. Further, the stress is evaluated as a function of the thermoelastic strain, temperature, and other state variables. Advection of tensor quantities, such as the strain, is coupled with possibly significant advection errors. In an effort to reduce the advection errors, we develop two rate forms of an established dislocation density-based continuum model. To that end, we replace the multiplicative decomposition of the deformation gradient with the additive decomposition of the velocity gradient, and define the stress rate instead of the total stress. The Eulerian implementation is compared with Lagrangian calculations, and two numerical examples with severe deformation levels are presented.

36 MATERIALS SCIENCE↗

Implementation, capabilities, and benchmarking of Shift, a massively parallel Monte Carlo radiation transport code

This paper discusses the implementation, capabilities, and validation of Shift, a massively parallel Monte Carlo radiation transport package developed and maintained at Oak Ridge National Laboratory. It has been developed to scale well from laptop to small computing clusters to advanced supercomputers. Special features of Shift include hybrid capabilities for variance reduction such as CADIS and FW-CADIS, and advanced parallel decomposition and tally methods optimized for scalability on supercomputing architectures. Shift has been validated and verified against various reactor physics benchmarks and compares well to other state-of-the-art Monte Carlo radiation transport codes such as MCNP5, CE KENO-VI, and OpenMC. Some specific benchmarks used for verification and validation include the CASL VERA criticality test suite and several Westinghouse AP1000 ® problems. These benchmark and scaling studies show promising results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation of the full viscoresistive magnetohydrodynamic equations in a nonlinear finite element code

Numerical simulations form an indispensable tool to understand the behavior of a hot plasma that is created inside a tokamak for providing nuclear fusion energy. Various aspects of tokamak plasmas have been successfully studied through the reduced magnetohydrodynamic (MHD) model. The need for more complete modeling through the full MHD equations is addressed here. Our computational method is presented along with measures against possible problems regarding pollution, stability, and regularity. The problem of ensuring continuity of solutions in the center of a polar grid is addressed in the context of a finite element discretization of the full MHD equations. A rigorous and generally applicable solution is proposed here. Useful analytical test cases are devised to verify the correct implementation of the momentum and induction equation, the hyperdiffusive terms, and the accuracy with which highly anisotropic diffusion can be simulated. A striking observation is that highly anisotropic diffusion can be treated with the same order of accuracy as isotropic diffusion, even on non-aligned grids, as long as these grids are generated with sufficient care. This property is shown to be associated with our use of a magnetic vector potential to describe the magnetic field. Several well-known instabilities are simulated to demonstrate the capabilities of the new method. The linear growth rate of an internal kink mode and a tearing mode are benchmarked against the results of a linear MHD code. The evolution of a tearing mode and the resulting magnetic islands are simulated well into the nonlinear regime. The results are compared with predictions from the reduced MHD model. Finally, a simulation of a ballooning mode illustrates the possibility to use our method as an ideal MHD method without the need to add any physical dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-performance implementation of Chebyshev filter diagonalization for interior eigenvalue computations

We study Chebyshev filter diagonalization as a tool for the computation of many interior eigenvalues of very large sparse symmetric matrices. In this technique the subspace projection onto the target space of wanted eigenvectors is approximated with filter polynomials obtained from Chebyshev expansions of window functions. After the discussion of the conceptual foundations of Chebyshev filter diagonalization we analyze the impact of the choice of the damping kernel, search space size, and filter polynomial degree on the computational accuracy and effort, before we describe the necessary steps towards a parallel high-performance implementation. Because Chebyshev filter diagonalization avoids the need for matrix inversion it can deal with matrices and problem sizes that are presently not accessible with rational function methods based on direct or iterative linear solvers. To demonstrate the potential of Chebyshev filter diagonalization for large-scale problems of this kind we include as an example the computation of the 10{sup 2} innermost eigenpairs of a topological insulator matrix with dimension 10{sup 9} derived from quantum physics applications.

97 MATHEMATICS AND COMPUTING↗

Implementing contact angle boundary conditions for second-order Phase-Field models of wall-bounded multiphase flows

In the present work, a general formulation is proposed to implement the contact angle boundary conditions for the second-order Phase-Field models, which is applicable to N-phase (N ≥ 2) moving contact line problems. To remedy the issue of mass change due to the contact angle boundary condition, a source term or Lagrange multiplier is added to the original second-order Phase-Field models, which is determined by the consistent and conservative volume distribution algorithm so that the summation of the order parameters and the consistency of reduction are not influenced. To physically couple the proposed formulation to the hydrodynamics, especially for large-density-ratio problems, the consistent formulation is employed. The reduction-consistent conservative Allen-Cahn models are chosen as examples to illustrate the application of the proposed formulation. The numerical scheme that preserves the consistency and conservation of the proposed formulation is employed to demonstrate its effectiveness. Results produced by the proposed formulation are in good agreement with the exact and/or asymptotic solutions. The proposed method captures complex dynamics of moving contact line problems having large density ratios.

97 MATHEMATICS AND COMPUTING↗

An efficient explicit implementation of a near-optimal quantum algorithm for simulating linear dissipative differential equations

We propose an efficient block-encoding technique for the implementation of the Linear Combination of Hamiltonian Simulations (LCHS) for simulating dissipative initial-value problems. This algorithm approximates a target nonunitary operator as a weighted sum of Hamiltonian evolutions, thereby emulating a dissipative problem by mixing various time scales. We introduce an efficient encoding of the LCHS into a quantum circuit based on a simple coordinate transformation that turns the dependence on the summation index into a trigonometric function. Classically, this method is equivalent to the use of a highly accurate Fejér-Clenshaw-Curtis quadrature formula. Quantumly, this significantly simplifies block-encoding of a dissipative problem and allows one to perform an exponential number of Hamiltonian simulations by a single Quantum Signal Processing (QSP) circuit. The resulting LCHS circuit has high success probability and the selector scales logarithmically with the number of terms in the LCHS sum and linearly with time. Careful analysis of error convergence proves that this method is more efficient than other LCHS circuits that have recently appeared in the literature. We verify the quantum circuit and its scaling by simulating it on a digital emulator of fault-tolerant quantum computers and, as a test problem, solve the advection-diffusion equation. The proposed algorithm can be used for simulating a wide class of nonunitary initial-value problems including the Liouville equation with added dissipation and linear embeddings of nonlinear systems, such as the Koopman-von Neumann and Carleman embeddings.

Novikau, I [Lawrence Livermore National Laboratory↗

Numerical implementation of non-local polycrystal plasticity using fast Fourier transforms

Here, we present the numerical implementation of a non-local polycrystal plasticity theory using the FFT-based formulation of Suquet and co-workers. Gurtin (2002) non-local formulation, with geometry changes neglected, has been incorporated in the EVP-FFT algorithm of Lebensohn et al. (2012). Numerical procedures for the accurate estimation of higher order derivatives of micromechanical fields, required for feedback into single crystal constitutive relations, are identified and applied. A simple case of a periodic laminate made of two fcc crystals with different plastic properties is first used to assess the soundness and numerical stability of the proposed algorithm and to study the influence of different model parameters on the predictions of the non-local model. Different behaviors at grain boundaries are explored, and the one consistent with the micro-clamped condition gives the most pronounced size effect. The formulation is applied next to 3-D fcc polycrystals, illustrating the possibilities offered by the proposed numerical scheme to analyze the mechanical response of polycrystalline aggregates in three dimensions accounting for size dependence arising from plastic strain gradients with reasonable computing times.

36 MATERIALS SCIENCE↗

Generalized grain boundary constitutive description implemented in a strain-gradient large-strain FFT-based formulation: Application to nano-metallic laminates

Herein this paper presents a general treatment of grain boundary constitutive behavior in the context of strain-gradient (SG) plasticity, and its numerical implementation in a large-strain (LS) elasto-viscoplastic (EVP) fast Fourier transform (FFT)-based micromechanical model. Two novel grain boundary constitutive equations are proposed, allowing for more accurate description of the Burgers vector flow at the grain boundary. The capabilities of the generalized SG-LS-EVPFFT formulation are illustrated for the case of kink-band formation during layer-parallel compression of nano-metallic laminates (NMLs), requiring consideration of the interaction between dislocations and interfaces.

36 MATERIALS SCIENCE↗

Fuel relocation recovery implementation in Bison

During the initial rise to power in light water reactors (LWR), thermal gradients within a pellet cause radial and axial cracks to form in the fuel. The effect of these cracks is to reduce the pellet-cladding gap and accelerate the interaction between the fuel and cladding. This process is known as fuel relocation and may also include contributions from pellet eccentricity and cladding ovality. Since the cladding experiences both elevated temperatures and high external pressure due to the coolant, the cladding typically creeps inward further reducing the pellet-cladding gap. Once the gap is closed and pellet cladding mechanical interaction (PCMI) begins, both the thermal and mechanical behavior of the fuel is affected. The compressive forces exerted on the fuel due to contact with the cladding cause the fractured fuel sections to move back toward their original position which is termed relocation recovery. A model for this phenomenon is implemented in the BISON fuel performance code and applied to a set of validation test cases. In conclusion, the predicted fuel rod diameter is compared to experimental measurements to evaluate the influence of relocation recovery over a range of operating conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗