Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Differences in the hemodynamic response to event-related motor and visual paradigms as measured by near-infrared spectroscopy

Several current brain imaging techniques rest on the assumption of a tight coupling between neural activity and hemodynamic response. The nature of this neurovascular coupling, however, is not completely understood. There is some evidence for a decoupling of these processes at the onset of neural activity, which manifests itself as a momentary increase in the relative concentration of deoxyhemoglobin (HbR). The existence of this early component of the hemodynamic response function, however, is controversial, as it is inconsistently found. Near infrared spectroscopy (NIRS) allows quantification of levels of oxyhemoglobin (HbO(2)) and HbR during task performance in humans. We acquired NIRS data during performance of simple motor and visual tasks, using rapid-presentation event-related paradigms. Our results demonstrate that rapid, event-related NIRS can provide robust estimates of the hemodynamic response without artifacts due to low-frequency signal components, unlike data from blocked designs. In both the motor and visual data the onset of the increase in HbO(2) occurs before HbR decreases, and there is a poststimulus undershoot. Our results also show that total blood volume (HbT) drops before HbO(2) and undershoots baseline, raising a new issue for neurovascular models. We did not find early deoxygenation in the motor data using physiologically plausible values for the differential pathlength factor, but did find one in the visual data. We suggest that this difference, which is consistent with functional magnetic resonance imaging (fMRI) data, may be attributable to different capillary transit times in these cortices.

NASA Program Biomedical Research and Countermeasur↗

Space Infrared Telescope Facility (SIRTF) science instruments

Concepts of scientific instruments designed to perform infrared astronomical tasks such as imaging, photometry, and spectroscopy are discussed as part of the Space Infrared Telescope Facility (SIRTF) project under definition study at NASA/Ames Research Center. The instruments are: the multiband imaging photometer, the infrared array camera, and the infrared spectograph. SIRTF, a cryogenically cooled infrared telescope in the 1-meter range and wavelengths as short as 2.5 microns carrying multiple instruments with high sensitivity and low background performance, provides the capability to carry out basic astronomical investigations such as deep search for very distant protogalaxies, quasi-stellar objects, and missing mass; infrared emission from galaxies; star formation and the interstellar medium; and the composition and structure of the atmospheres of the outer planets in the solar sytem.

Ramos, R.↗

Exploring rock-regolith interfaces in Jezero crater with Mars 2020 SHERLOC

The Perseverance rover successfully landed in Jezero crater, Mars in February 2021 at the Octavia E. Butler landing site and began its mission to explore and sample an ancient crater lake basin. Principal goals of the Mars 2020 mission include characterizing the geology of Mars and seeking signs of ancient microbial life via the spacecraft cameras and spectroscopic instruments onboard. The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument is a deep UV Raman spectrometer that utilizes a 248.6nm pulsed laser. Part of SHERLOC is a color camera known as the Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). The SHERLOC suite provides coordinated, spectroscopic and imaging capabilities at high spatial resolution, to detect minerals and organic molecules in microtextural context. By pairing high spatial resolution (~100 μm) resonance Raman and native fluorescence spectroscopy with microscopic imaging in a novel spacecraft capability, SHERLOC enables texture-specific molecular composition measurements of rock and regolith targets on Mars. Coordinated rock-regolith observations illuminate unique insights into weathering processes and thereby to primary properties of rocks in Jezero crater. This work describes the potential of rock-regolith interfaces to preserve unique records of geological processes in Jezero crater and can powerfully supplement observations of the more general rock record on Mars. Linking observations of local rock texture with associated regolith reveals important lithologic information based on the interrelationship between differential weathering behavior and mineralogy, grain size, and cement chemistry. Preliminary observations indicate that the polygonally fractured lithotype common near the Octavia E. Butler landing site may weather by granular disintegration and/or surface creep, a relation that can be uniquely observed at the rock-regolith interface. SHERLOC -specific observations of microtextural and elemental composition transitions presented here trace rock-regolith boundaries at multiple indurated surfaces adjacent to regolith. At these locales, grain-scale based examinations suggest chemical weathering could be related to a variably distributed coating or rind on dark rock targets that may be mafic in composition. Granule deposits overlying widely distributed fine-grained material are also observable. Mineral identifications of each phase are presented, with cross-scale comparisons to the remote insights gained by the SuperCam instrument.

Emily L. Cardarelli↗

The Quickest, Lowest-cost Lunar Resource Assessment Program: Integrated High-tech Earth-based Astronomy

Science and technology applications for the Moon have not fully kept pace with technical advancements in sensor development and analytical information extraction capabilities. Appropriate unanswered questions for the Moon abound, but until recently there has been little motivation to link sophisticated technical capabilities with specific measurement and analysis projects. Over the last decade enormous technical progress has been made in the development of (1) CCD photometric array detectors; (2) visible to near-infrared imaging spectrometers; (3)infrared spectroscopy; (4) high-resolution dual-polarization radar imaging at 3.5, 12, and 70 cm; and equally important (5) data analysis and information extraction techniques using compact powerful computers. Parts of each of these have been tested separately, but there has been no programmatic effort to develop and optimize instruments to meet lunar science and resource assessment needs (e.g., specific wavelength range, resolution, etc.) nor to coordinate activities so that the symbiotic relation between different kinds of data can be fully realized. No single type of remotely acquired data completely characterizes the lunar environment, but there has been little opportunity for integration of diverse advanced sensor data for the Moon. Two examples of technology concepts for lunar measurements are given. Using VIS/near-IR spectroscopy, the mineral composition of surface material can be derived from visible and near-infrared radiation reflected from the surface. The surface and subsurface scattering properties of the Moon can be analyzed using radar backscattering imaging.

Pieters, Carle M.↗

Lens Model and Source Reconstruction Reveal the Morphology and Star Formation Distribution in the Cool Spiral LIRG SGAS J143845.1+145407

We present Hubble Space Telescope (HST) imaging and grism spectroscopy of a strongly lensed LIRG at z = 0.816, SGAS 143845.1+145407, and use the magnification boost of gravitational lensing to study the distribution of star formation throughout this galaxy. Based on the HST imaging data, we create a lens model for this system; we compute the mass distribution and magnification map of the z = 0.237 foreground lens. We find that the magnification of the lensed galaxy ranges between 2 and 10, with a total magnification (measured over all the images of the source) of μ = ${11.8}_{-2.4}^{+4.6}$. We find that the total projected mass density within ∼34 kpc of the brightest cluster galaxy is 6.0(+0.3,-0.7) x 10^(12)Mꙩ. Using the lens model we create a source reconstruction for SGAS 143845.1+145407, which, paired with a faint detection of Hα in the grism spectroscopy, allows us to finally comment directly on the distribution of star formation in a z ∼ 1 LIRG. We find widespread star formation across this galaxy, in agreement with the current understanding of these objects. However, we note a deficit of Hα emission in the nucleus of SGAS 143845.1+145407, likely due to dust extinction.

Samuel J. Dunham↗

COOL-LAMPS. IV. A Sample of Bright Strongly Lensed Galaxies at 3 < z < 4

We report the discovery of five bright, strong gravitationally lensed galaxies at 3 < z < 4: COOL J0101+2055 (z = 3.459), COOL J0104–0757 (z = 3.480), COOL J0145+1018 (z = 3.310), COOL J0516–2208 (z = 3.549), and COOL J1356+0339 (z = 3.753). These galaxies have magnitudes of r AB , z AB < 21.81 mag and are lensed by galaxy clusters at 0.26 < z < 1. This sample nearly doubles the number of known bright lensed galaxies with extended arcs at 3 < z < 4. We characterize the lensed galaxies using ground-based grz/giy imaging and optical spectroscopy. We report model-based magnitudes and derive stellar masses, dust content, and star formation rates via stellar population synthesis modeling. Building lens models based on ground-based imaging, we estimate source magnifications ranging from ~29 to ~180. Combining these analyses, we derive demagnified stellar masses in the range log 10 (M * /M ⊙ ) ~ 9.69 – 10.75 and star formation rates in the youngest age bin in the range log 10 (SFR/(M ⊙ yr -1 )) ~ 0.39 – 1.46, placing the sample galaxies on the massive end of the star-forming main sequence in this redshift interval. In addition, three of the five galaxies have strong Lyα emissions, offering unique opportunities to study Lyα emitters at high redshift in future work.

79 ASTRONOMY AND ASTROPHYSICS↗

Ghost-imaging-enhanced noninvasive spectral characterization of stochastic x-ray free-electron-laser pulses

Abstract High-intensity ultrashort X-ray free-electron laser (XFEL) pulses are revolutionizing the study of fundamental nonlinear x-ray matter interactions and coupled electronic and nuclear dynamics. To fully exploit the potential of this powerful tool for advanced x-ray spectroscopies, a noninvasive spectral characterization of incident stochastic XFEL pulses with high resolution is a key requirement. Here we present a methodology that combines high-acceptance angle-resolved photoelectron time-of-flight spectroscopy and ghost imaging to enhance the quality of spectral characterization of x-ray free-electron laser pulses. Implementation of this noninvasive high-resolution x-ray diagnostic can greatly benefit the ultrafast x-ray spectroscopy community by functioning as a transparent beamsplitter for applications such as transient absorption spectroscopy in averaging mode as well as covariance-based x-ray nonlinear spectroscopies in single-shot mode where the shot-to-shot fluctuations inherent to a self-amplified spontaneous emission (SASE) XFEL pulse are a powerful asset.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear and large-scale outflow in NGC 1808

NGC 1808 has been studied via deep broad-band and H-alpha images and longslit spectroscopy around the Na I D and H-alpha lines. In particular, Na I is seen blueshifted in absorption and redshifted in emission, providing incontrovertible proof of outflow. B-R images show that the dust plumes associated with the outflow reach about 3 kpc or more above the plane. The morphology of the outflow is complex. Nuclear emission and absorption line profiles show pronounced blue wings similar to those seen in far-IR luminous galaxies (FIRGs), and indicate nuclear outflow velocities up to 700 km/s. The classification of NGC 1808 as a Seyfert 2 is reviewed and dismissed; rather, on the basis of line profiles and ratios and the presence of the 'superwind', NGC 1808 is probably an example of the FIRG phenomenon.

Phillips, Andrew C.↗

Observation of bound valence excited electronic states of deprotonated 2-hydroxytriphenylene using photoelectron, photodetachment, and resonant two-photon detachment spectroscopy of cryogenically cooled anions

Polycyclic aromatic hydrocarbons (PAHs) are common atmospheric pollutants, and they are also ubiquitous in the interstellar medium. Here, we report the study of a complex O-containing PAH anion, the deprotonated 2-hydroxytriphenylene (2-OtPh–), using high-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled anions. Vibrationally resolved photoelectron spectra yield the electron affinity of the 2-OtPh radical as 2.629(1) eV and several vibrational frequencies for its ground electronic state. Photodetachment spectroscopy reveals bound valence excited electronic states for the 2-OtPh– anion, with unprecedentedly rich vibronic features. Evidence is presented for a low-lying triplet state (T1) and two singlet states (S1 and S2) below the detachment threshold. Single-color resonant two-photon photoelectron spectroscopy uncovers rich photophysics for the 2-OtPh– anion, including vibrational relaxation in S1, internal conversion to the ground state of 2-OtPh–, intersystem crossing from S2 to T1, and a long-lived autodetaching shape resonance about 1.3 eV above the detachment threshold. The rich electronic structure and photophysics afforded by the current study suggest that 2-OtPh– would be an interesting system for pump–probe experiments to unravel the dynamics of the excited states of this complex PAH anion.

Chemistry↗

COOL-LAMPS. I. An Extraordinarily Bright Lensed Galaxy at Redshift 5.04

In this paper, we report the discovery of COOL J1241+2219, a strongly lensed galaxy at redshift z = 5.043 ± 0.002 with observed magnitude z AB = 20.47, lensed by a moderate-mass galaxy cluster at z = 1.001 ± 0.001. COOL J1241+2219 is the brightest lensed galaxy currently known at optical and near-infrared wavelengths at z $\gtrsim$ 5; it is ~5 times brighter than the prior record-holder lensed galaxy, and several magnitudes brighter than the brightest unlensed galaxies known at these redshifts. It was discovered as part of COOL-LAMPS, a collaboration initiated to find strongly lensed systems in recent public optical imaging data. We characterize the lensed galaxy, as well as the central galaxy of the lensing cluster using ground-based grizJH imaging and optical spectroscopy. We report model-based magnitudes, and derive stellar masses, dust content, metallicity, and star-formation rates via stellar-population synthesis modeling. Our lens mass modeling, based on ground-based imaging, implies a median source magnification of ~30, which puts the stellar mass and star-formation rate (in the youngest age bin, closest to the epoch of observation) at logM* = ${10.11}_{-0.26}^{+0.21}$ and SFR = ${27}_{-9}^{+13} M_⊙$ yr –1 , respectively. We constrain a star-formation history for COOL J1241+2219 consistent with constant star formation across ~1 Gyr of cosmic time, and that places this galaxy on the high-mass end of the star-forming main sequence. COOL J1241+2219 is two to four times more luminous than a galaxy with the characteristic UV luminosity at these redshifts. The UV continuum slope β = –2.2 ± 0.2 places this galaxy on the blue side of the observed distribution of galaxies at z = 5, although the lack of Lyα emission indicates dust sufficient to suppress this emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Material Response During Arc-Jet Testing with Optical Methods Status and Perspectives

The characterization of ablation and recession of heat shield materials during arc jet testing is an important step towards understanding the governing processes during these tests and therefore for a successful extrapolation of ground test data to flight. The behavior of ablative heat shield materials in a ground-based arc jet facility is usually monitored through measurement of temperature distributions (across the surface and in-depth), and through measurement of the final surface recession. These measurements are then used to calibrate/validate materials thermal response codes, which have mathematical models with reasonably good fidelity to the physics and chemistry of ablation, and codes thus calibrated are used for predicting material behavior in flight environments. However, these thermal measurements only indirectly characterize the pyrolysis processes within an ablative material pyrolysis is the main effect during ablation. Quantification of pyrolysis chemistry would therefore provide more definitive and useful data for validation of the material response codes. Information of the chemical products of ablation, to various levels of detail, can be obtained using optical methods. Suitable optical methods to measure the shape and composition of these layers (with emphasis on the blowing layer) during arc jet testing are: 1) optical emission spectroscopy (OES) 2) filtered imaging 3) laser induced fluorescence (LIF) and 4) absorption spectroscopy. Several attempts have been made to optically measure the material response of ablative materials during arc-jet testing. Most recently, NH and OH have been identified in the boundary layer of a PICA ablator. These species are suitable candidates for a detection through PLIF which would enable a spatially-resolved characterization of the blowing layer in terms of both its shape and composition. The recent emission spectroscopy data will be presented and future experiments for a qualitative and quantitative characterization of the material response of ablative materials during arc-jet testing will be discussed.

Winter, Michael↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

COOL-LAMPS. II. Characterizing the Size and Star Formation History of a Bright Strongly Lensed Early-type Galaxy at Redshift 1.02

We present COOL J1323+0343, an early-type galaxy at z = 1.0153 ± 0.0006, strongly lensed by a cluster of galaxies at z = 0.353 ± 0.001. This object was originally imaged by DECaLS and noted as a gravitational lens by COOL-LAMPS, a collaboration initiated to find strong-lensing systems in recent public optical imaging data, and confirmed with follow-up data. With ground-based grzH imaging and optical spectroscopy from the Las Campanas Observatory and the Nordic Optical Telescope, we derive a stellar mass, metallicity, and star formation history from stellar-population synthesis modeling. The lens modeling implies a total magnification, summed over the three images in the arc, of μ ~ 113. The stellar mass in the source plane is M * ~ 10.64 M ⊙ and the 1σ upper limit on the star formation rate (SFR) in the source plane is SFR ~ 3.75 × 10 -2 M ⊙ yr -1 (log sSFR = -12.1 yr -1 ) in the youngest two age bins (0–100 Myr), closest to the epoch of observation. Our measurements place COOL J1323+0343 below the characteristic mass of the stellar mass function, making it an especially compelling target that could help clarify how intermediate-mass quiescent galaxies evolve. We reconstruct COOL J1323+0343 in the source plane and fit its light profile. This object is below the expected size evolution of an early-type galaxy at this mass with an effective radius r e ~ 0.5 kpc. This extraordinarily magnified and bright lensed early-type galaxy offers an exciting opportunity to study the morphology and star formation history of an intermediate-mass early-type galaxy in detail at z ~ 1.

79 ASTRONOMY AND ASTROPHYSICS↗