Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Using DSCOVR EPIC as a Transfer Radiometer to Scale Leo Imagers to the Same Calibration Reference

The NASA CERES project provides climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used in tandem with the MODIS and VIIRS instruments to retrieve cloud properties required for converting CERES radiance observations into fluxes. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua-MODIS reference to retrieve consistent imager cloud properties between sensors. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun-synchronous orbit but spaced equally apart, allowing for no simultaneous nadir overpasses (SNO) to inter-calibrate the VIIRS imagers to each other. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between neither MODIS nor VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers. The study will demonstrate the use of EPIC to radiometrically scale VIIRS and MODIS imagers to the same Aqua-MODIS calibration reference. The EPIC-based NPP and N20-VIIRS scaling factors will be compared with the Aqua-MODIS based NPP and N20-VIIRS scaling factors.

C. O. Haney↗

Man-machine interactive imaging and data processing using high-speed digital mass storage

The role of vision in teleoperation has been recognized as an important element in the man-machine control loop. In most applications of remote manipulation, direct vision cannot be used. To overcome this handicap, the human operator's control capabilities are augmented by a television system. This medium provides a practical and useful link between workspace and the control station from which the operator perform his tasks. Human performance deteriorates when the images are degraded as a result of instrumental and transmission limitations. Image enhancement is used to bring out selected qualities in a picture to increase the perception of the observer. A general purpose digital computer, an extensive special purpose software system is used to perform an almost unlimited repertoire of processing operations.

Alsberg, H.↗

A Motion-Compensating Image-Compression Scheme

Chrominance used (in addition to luminance) in estimating motion. Variable-rate digital coding scheme for compression of color-video-image data designed to deliver pictures of good quality at moderate compressed-data rate of 1 to 2 bits per pixel, or of fair quality at rate less than 1 bit per pixel. Scheme, in principle, implemented by use of commercially available application-specific integrated circuits. Incorporates elements of some prior coding schemes, including motion compensation (MC) and discrete cosine transform (DCT).

Wong, Carol↗

NIRS in Space?

Proponents of near infrared reflectance spectroscopy (NIRS) have been exceptionally successful in applying NIRS techniques to many instances of organic material analyses. While this research and development began in the 1950s, in recent years, stimulation of advancements in instrumentation is allowing NIRS to begin to find its way into the food processing systems, into food quality and safety, textiles and much more. And, imaging high spectral resolution spectrometers are now being evaluated for the rapid scanning of foodstuffs, such as the inspection of whole chicken carcasses for fecal contamination. The imaging methods are also finding their way into medical applications, such as the non-intrusive monitoring of blood oxygenation in newborns. Can these scientific insights also be taken into space and successfully used to measure the Earth's condition? Is there an analog between the organic analyses in the laboratory and clinical settings and the study of Earth's living biosphere? How are the methods comparable and how do they differ?

Peterson, David L.↗

Derivative Analysis of AVIRIS Hyperspectral Data for the Detection of Plant Stress

A remote sensing campaign was conducted over a U.S. Department of Agriculture test site at Shelton, Nebraska. The test field was set off in blocks that were differentially treated with nitrogen. Four replicates of 0-kg/ha to 200-kg/ha, in 50-kg/ha increments, were present. Low-altitude AVIRIS hyperspectral data were collected over the site in 224 spectral bands. Simultaneously, ground data were collected to support the airborne imagery. In an effort to evaluate published, derivative-based algorithms for the detection of plant stress, different derivative-based approaches were applied to the collected AVIRIS image cube. The results indicate that, given good quality hyperspectral imagery, derivative techniques compare favorably with simple, well known band ratio algorithms for detection of plant stress.

Estep, Lee↗

Hubble Space Telescope Imaging of the Circumnuclear Environments of the CfA Seyfert Galaxies: Nuclear Spirals and Fueling

We present archival Hubble Space Telescope (HST) images of the nuclear regions of 43 of the 46 Seyfert galaxies found in the volume limited,spectroscopically complete CfA Redshift Survey sample. Using an improved method of image contrast enhancement, we created detailed high-quality " structure maps " that allow us to study the distributions of dust, star clusters, and emission-line gas in the circumnuclear regions (100-1000 pc scales) and in the associated host galaxy. Essentially all of these Seyfert galaxies have circumnuclear dust structures with morphologies ranging from grand-design two-armed spirals to chaotic dusty disks. In most Seyfert galaxies there is a clear physical connection between the nuclear dust spirals on hundreds of parsec scales and large-scale bars and spiral arms in the host galaxies proper. These connections are particularly striking in the interacting and barred galaxies. Such structures are predicted by numerical simulations of gas flows in barred and interacting galaxies and may be related to the fueling of active galactic nuclei by matter inflow from the host galaxy disks. We see no significant differences in the circumnuclear dust morphologies of Seyfert 1s and 2s, and very few Seyfert 2 nuclei are obscured by large-scale dust structures in the host galaxies. If Sevfert 2s are obscured Sevfert Is, then the obscuration must occur on smaller scales than those probed by HST.

Pogge, Richard W.↗

CME-Producing Precursors to the 2006 December 13 X-Flare

We revisit one of the largest explosions observed during the Hinode era, the X4.3 class event of 2006 Dec 13. We gain insight into the main eruption through study of two sub-C-class precursor eruptions, occurring within 12 hours of and originating from the same (or nearby) neutral line as the X-flare. The precursors share some features in common with the main eruption, and their lower energy and consequent slower development renders interpretation of these features easier to decipher than in the rapidly explosive main eruption. In addition, because the weak precursors occurred in a magnetically strong region, magnetic connections indicated by soft X-ray loops are readily visible in these cases, while such connections can be much less apparent in weaker-region eruptions. Hinode/SOT magnetograms indicate that photospheric magnetic dynamic activity in the "magnetic core" is the likely ultimate source of the eruptions. All the eruptions, however, produce Coronal Mass Ejections (CMEs) that have wider spatial extent than the localized source region; this is a long-observed but puzzling phenomena, which can address directly here using the high-quality Hinode data. For the precursor eruptions, Hinode/XRT images show that the initial eruptions occur inside larger-scale magnetic structures that encompass the core. The exploding core field blows out this larger-scale structure, resulting in the CME having angular extent far exceeding that of the source-region core alone; this is the arch-arch-blowout scenario for CMEs of Moore & Sterling (2007). Similar processes occur in the main eruption, except that the much larger energy release in that eruption compared to the precursors results in much faster and larger-scale phenomena.

Sterling, Alphonse C.↗

nBn Infrared Detector Containing Graded Absorption Layer

It has been proposed to modify the basic structure of an nBn infrared photodetector so that a plain electron-donor- type (n-type) semiconductor contact layer would be replaced by a graded n-type III V alloy semiconductor layer (i.e., ternary or quarternary) with appropriate doping gradient. The abbreviation nBn refers to one aspect of the unmodified basic device structure: There is an electron-barrier ("B" ) layer between two n-type ("n" ) layers, as shown in the upper part of the figure. One of the n-type layers is the aforementioned photon-absorption layer; the other n-type layer, denoted the contact layer, collects the photocurrent. The basic unmodified device structure utilizes minority-charge-carrier conduction, such that, for reasons too complex to explain within the space available for this article, the dark current at a given temperature can be orders of magnitude lower (and, consequently, signal-to-noise ratios can be greater) than in infrared detectors of other types. Thus, to obtain a given level of performance, less cooling (and, consequently, less cooling equipment and less cooling power) is needed. [In principle, one could obtain the same advantages by means of a structure that would be called pBp because it would include a barrier layer between two electron-acceptor- type (p-type) layers.] The proposed modifications could make it practical to utilize nBn photodetectors in conjunction with readily available, compact thermoelectric coolers in diverse infrared- imaging applications that could include planetary exploration, industrial quality control, monitoring pollution, firefighting, law enforcement, and medical diagnosis.

Gunapala, Sarath D.↗

AlGaN Ultraviolet Detectors for Dual-Band UV Detection

This innovation comprises technology that has the ability to measure at least two ultraviolet (UV) bands using one detector without relying on any external optical filters. This allows users to build a miniature UVA and UVB monitor, as well as to develop compact, multicolor imaging technologies for flame temperature sensing, air-quality control, and terrestrial/counter-camouflage/biosensing applications.

Miko, Laddawan↗

Monitoring Invasive Aquatic Vegetation in Lake Okeechobee, Florida, Using NDVI Derived from Modis Data

Lake Okeechobee, located in southern Florida, encompasses approximately 1,700 sq km and is a vital part of the Lake Okeechobee and Everglades ecosystem. Major cyanobacterial blooms have been documented in Lake Okeechobee since the 1970s and have continued to plague the ecosystem. Similarly, hydrilla, water hyacinth, and water lettuce have been documented in the lake and continue to threaten the ecosystem by their rapid growth. This study examines invasive aquatic vegetation occurrence through the use of the Normalized Difference Vegetation Index (NDVI) calculated on MOD09 surface reflectance imagery. Occurrence during 2008 was analyzed using the Time Series Product Tool (TSPT), a MATLAB-based program developed at John C. Stennis Space Center. This project tracked spatial and temporal variability of cyanobacterial blooms, and overgrowth of water lettuce, water hyacinth, and hydrilla. In addition, this study presents an application of Moderate Resolution Imaging Spectroradiometer (MODIS) data to assist in water quality management.

Woods, Kate↗

Polarization Phase-Compensating Coats for Metallic Mirrors

A method of compensating for or minimizing phase differences between orthogonal polarizations of light reflected from metallic mirrors at oblique incidence, as, for example, from weakly curved mirrors, is undergoing development. The method is intended to satisfy a need to maintain precise polarization phase relationships or minimum polarization differences needed for proper operation of telescopes and other scientific instruments that include single or multiple mirrors. The basic idea of the method is to optimally coat mirrors with thin engineered layers of materials that introduce phase differences that, as nearly precisely as possible, are opposite of the undesired phase differences arising in reflection with non-optimum coatings. Depending on the specific optical system, the method could involve any or all of the following elements: a) Optimization of a single coat on all the mirrors in the system. b) Optimization of a unique coat for each mirror such that the polarization phase effects of the coat on one mirror compensate, to an acceptably high degree over an acceptably wide wavelength range, for those of the coat on another mirror. c) Tapering the coat on each mirror. Optimization could involve the choice of a single dielectric coating material and its thickness, or design of a more complex coat consisting of multiple layers of different dielectric materials and possibly some metallic materials. Such designs and coatings are particularly significant and needed for obtaining very high quality of wavefront required in high-contrast imaging instruments such as the NASA Terrestrial Planet Finder Coronagraph.

Balasubramanian, Kunjithapatham↗

A Study of Acoustic Reflections in Full-Scale Rotor Low Frequency Noise Measurements Acquired in Wind Tunnels

Difficulties in obtaining full-scale rotor low frequency noise measurements in wind tunnels are addressed via residual sound reflections due to non-ideal anechoic wall treatments. Examples illustrated with the Boeing-SMART rotor test in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel facility demonstrated that these reflections introduced distortions in the measured acoustic time histories that are not representative of free-field rotor noise radiation. A simplified reflection analysis, based on the method of images, is used to examine the sound measurement quality in such "less-than-anechoic" environment. Predictions of reflection-adjusted acoustic time histories are qualitatively shown to account for some of the spurious fluctuations observed in wind tunnel noise measurements

Barbely, Natasha L.↗

Effects of Digitization and JPEG Compression on Land Cover Classification Using Astronaut-Acquired Orbital Photographs

Studies that utilize astronaut-acquired orbital photographs for visual or digital classification require high-quality data to ensure accuracy. The majority of images available must be digitized from film and electronically transferred to scientific users. This study examined the effect of scanning spatial resolution (1200, 2400 pixels per inch [21.2 and 10.6 microns/pixel]), scanning density range option (Auto, Full) and compression ratio (non-lossy [TIFF], and lossy JPEG 10:1, 46:1, 83:1) on digital classification results of an orbital photograph from the NASA - Johnson Space Center archive. Qualitative results suggested that 1200 ppi was acceptable for visual interpretive uses for major land cover types. Moreover, Auto scanning density range was superior to Full density range. Quantitative assessment of the processing steps indicated that, while 2400 ppi scanning spatial resolution resulted in more classified polygons as well as a substantially greater proportion of polygons < 0.2 ha, overall agreement between 1200 ppi and 2400 ppi was quite high. JPEG compression up to approximately 46:1 also did not appear to have a major impact on quantitative classification characteristics. We conclude that both 1200 and 2400 ppi scanning resolutions are acceptable options for this level of land cover classification, as well as a compression ratio at or below approximately 46:1. Auto range density should always be used during scanning because it acquires more of the information from the film. The particular combination of scanning spatial resolution and compression level will require a case-by-case decision and will depend upon memory capabilities, analytical objectives and the spatial properties of the objects in the image.

Robinson, Julie A.↗

Mini-TES Observations of Comanche Carbonate and Its Distribution

The discovery by the Spirit rover of outcrops rich in Mg-Fe carbonate [Morris et al., 2010] represents another manifestation of a diverse aqueous history in Gusev crater. In 2005, observations by the Moessbauer spectrometer (MB) on outcrops dubbed Comanche provided initial indication of Fe-Mg carbonate that was subsequently supported by analysis of elemental data from the Alpha Particle X-ray Spectrometer (APXS). The recognition of a carbonate component in thermal infrared spectra measured by the Miniature Thermal Emission Spectrometer (Mini-TES) was significantly delayed due to dust contamination of the instrument's optics. With the implementation of a viable dust correction, the Comanche spectra were revisited and presented clear and compelling evidence for a Mg-Fe carbonate component that could be as much as a third of the total mineral abundance. The data from all three instruments in combination are best matched by Mg-Fe carbonate with an abundance of 16-34 wt%. Mini-TES spectra were acquired for 12 targets at various locations on the Comanche (4-5 m long) and Comanche Spur (1-2 m long) outcrops, the latter being the location of the MB and APXS measurements. The two outcrops are spectrally comparable and share similar morphology and texture based on color images from the Panoramic Camera (Pancam). The highest quality Mini-TES spectrum comes from the larger Comanche outcrop on a target named Saupitty. Linear least squares modeling of the Saupitty spectrum employed a library of laboratory spectra tailored for consistency with the APXS and MB data and included spectra representing Martian dust, a slope spectrum to account for any temperature determination errors, and a blackbody spectrum to account for differences in spectral contrast between the laboratory and Mini-TES spectrum. Successful modeling of the Comanche Saupitty spectrum required one or more carbonate phases to obtain a good fit. Excluding all carbonates from the full starting library more than doubled the root-mean-squared error of the model fit (0.147% vs. 0.299%). Because Mg-Fe carbonate and Ca-Mg carbonate (dolomite) are so spectrally similar over the range used for modeling, both provide a comparable fit. However, Carich carbonates like dolomite are precluded based on APXS data and are inconsistent with MB results. The Comanche carbonate rocks are stratigraphically above a set of olivine-rich volcaniclastic rocks known as Algonquin class that mantle the Haskin Ridge feature of the Columbia Hills. Based on ~50 Mini-TES observations, the Comanche outcrops are the only rocks that host abundant carbonate. However, a target at the base of the larger Comanche outcrop appears spectrally transitional between the carbonate and olivine units. This transitional spectral character applies to additional outcrops a few 10s of meters away from Comanche that also appear stratigraphically transitional. Additional work will attempt to establish whether we are seeing an alteration horizon or depositional unit associated with the emplacement Comanche carbonate.

Ruff, Steven W.↗

Aligning Arrays of Lenses and Single-Mode Optical Fibers

A procedure now under development is intended to enable the precise alignment of sheet arrays of microscopic lenses with the end faces of a coherent bundle of as many as 1,000 single-mode optical fibers packed closely in a regular array (see Figure 1). In the original application that prompted this development, the precise assembly of lenses and optical fibers serves as a single-mode spatial filter for a visible-light nulling interferometer. The precision of alignment must be sufficient to limit any remaining wavefront error to a root-mean-square value of less than 1/10 of a wavelength of light. This wavefront-error limit translates to requirements to (1) ensure uniformity of both the lens and fiber arrays, (2) ensure that the lateral distance from the central axis of each lens and the corresponding optical fiber is no more than a fraction of a micron, (3) angularly align the lens-sheet planes and the fiber-bundle end faces to within a few arc seconds, and (4) axially align the lenses and the fiber-bundle end faces to within tens of microns of the focal distance. Figure 2 depicts the apparatus used in the alignment procedure. The beam of light from a Zygo (or equivalent) interferometer is first compressed by a ratio of 20:1 so that upon its return to the interferometer, the beam will be magnified enough to enable measurement of wavefront quality. The apparatus includes relay lenses that enable imaging of the arrays of microscopic lenses in a charge-coupled-device (CCD) camera that is part of the interferometer. One of the arrays of microscopic lenses is mounted on a 6-axis stage, in proximity to the front face of the bundle of optical fibers. The bundle is mounted on a separate stage. A mirror is attached to the back face of the bundle of optical fibers for retroreflection of light. When a microscopic lens and a fiber are aligned with each other, the affected portion of the light is reflected back by the mirror, recollimated by the microscopic lens, transmitted through the relay lenses and the beam compressor/expander, then split so that half goes to a detector and half to the interferometer. The output of the detector is used as a feedback control signal for the six-axis stage to effect alignment.

Liu, Duncan↗

Hi-C Observations of Penumbral Bright Dots

We use high-quality data obtained by the High Resolution Coronal Imager (Hi-C) to examine bright dots (BDs) in a sunspot's penumbra. The sizes of these BDs are on the order of 1 arcsecond (1") and are therefore hard to identify using the Atmospheric Imaging Assembly's (AIA) 0.6" pixel(exp −1) resolution. These BD become readily apparent with Hi-C's 0.1" pixel(exp −1) resolution. Tian et al. (2014) found penumbral BDs in the transition region (TR) by using the Interface Region Imaging Spectrograph (IRIS). However, only a few of their dots could be associated with any enhanced brightness in AIA channels. In this work, we examine the characteristics of the penumbral BDs observed by Hi-C in a sunspot penumbra, including their sizes, lifetimes, speeds, and intensity. We also attempt to find any association of these BDs to the IRIS BDs. There are fewer Hi-C BDs in the penumbra than seen by IRIS, though different sunspots were studied. We use 193 Angstroms Hi-C data from July 11, 2012 which observed from approximately 18:52:00 UT- 18:56:00 UT and supplement it with data from AIA's 193 Angstrom passband to see the complete lifetime of the dots that were born before and/or lasted longer than Hi- C's 5-minute observation period. We use additional AIA passbands and compare the light curves of the BDs at different temperatures to test whether the Hi-C BDs are TR BDs. We find that most Hi-C BDs show clear movement, and of those that do, they move in a radial direction, toward or away from the sunspot umbra. Single BDs interact with other BDs, combining to fade away or brighten. The BDs that do not interact with other BDs tend to move less. Many of the properties of our BDs are similar to the extreme values of the IRIS BDs, e.g., they move slower on average and their sizes and lifetimes are on the higher end of the IRIS BDs. We infer that our penumbral BDs are the large-scale end of the distribution of BDs observed by IRIS.

Alpert, S. E.↗

Toward Improving Short-Term Predictions of Fine Particulate Matter Over the United States Via Assimilation of Satellite Aerosol Optical Depth Retrievals

This study develops a new approach to improve simulations of the particulate matter of aerodynamic diameter smaller than 2.5μm (PM2.5) in the Community Multiscale Air Quality (CMAQ) model via assimilation of Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical depth(AOD) retrievals using the Grid point Statistical Interpolation (GSI) system. In contrast to previous studies that only consider errors due to transport, our computation of the background error covariance matrix incorporates uncertainties in anthropogenic emissions. To understand the impact of this approach, three experiments (one background and two assimilations) are performed over the contiguous United States(CONUS) from 15 July to 14 August 2014. The background CMAQ experiment significantly underestimates both the MODIS AOD and surface PM2.5levels. MODIS AOD assimilation pushes both the CMAQ AOD and surface PM2.5distributions toward the observed distributions, but CMAQ still underestimates the observations. Averaged over CONUS, the two assimilation experiments with and without including the anthropogenic emission uncertainties improve the correlation coefficient between the model and independent observations of PM2.5 by ~67% and ~48%, respectively, and reduces the mean bias by ~38% and~10%, respectively. The assimilation improves the model performance everywhere over CONUS, except the New York and Wisconsin, where CMAQ overestimates the observed PM2.5during nighttime after assimilation likely because of overcorrection of aerosol mass concentrations by the AOD assimilation. Future work should incorporate uncertainties in other processes (biomass burning and biogenic emissions, deposition, chemistry, transport, and boundary conditions) to further enhance the value of assimilating spaceborne AOD retrievals.

Assimilation↗