Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

System Measures Loads In Bolts

Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

Allison, Sidney G.↗

Satellites for the detection of nonsolar planets

Two sensor systems for the direct detection of nonsolar planets from earth orbit are evaluated: (1) an apodized visual telescope (APOTS), and (2) a spinning infrared interferometer (IRIS). Their performance characteristics and technology requirements for a five-year mission are determined. The simpler instrument, APOTS, requires a substantial improvement in mirror fabrication techniques before it can approach its full performance potential. The IRIS requires technology development in the areas of long-lifetime cryogenic systems and of active control techniques. Technology issues of secondary importance are discussed.

Bandermann, L. W.↗

Orientational atom interferometers sensitive to gravitational waves

We present an atom interferometer that differs from common atom interferometers as it is not based on the spatial splitting of electronic wave functions, but on orienting atoms in space. As an example we present how an orientational atom interferometer based on highly charged hydrogen-like atoms is affected by gravitational waves. We show that a monochromatic gravitational wave will cause a frequency shift that scales with the binding energy of the system rather than with its physical dimension. For a gravitational wave amplitude of h=10{sup -23} the frequency shift is of the order of 110 {mu}Hz for an atom interferometer based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current atom interferometers in 1 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods and systems of characterizing and counting microbiological colonies

Described herein are methods, systems, and non-transitory computer-readable media to non-destructively acquire three-dimensional profiles of cellular microbiological samples growing on the surface of a solid growth medium. Acquisitions can be performed by an optical microscope that includes a vertical scanning interferometer. The three-dimensional profiles can enable measurement of sample parameters of microcolonies, which can be made of microbial colony forming units. The methods and systems enable early and rapid detection and quantification of microbes.

Larimer, Curtis J.↗

Impact of Measurement System Characteristics on Advanced Sounder Information Content

Advanced satellite sensors are tasked with improving global observations of the Earth's atmosphere, clouds, and surface to enable enhancements in weather prediction, climate monitoring capability, and environmental change detection. Achieving such an improvement in geophysical information inferred from these observations requires optimal usage of data from current systems as well as instrument system enhancements for future sensors. This presentation addresses results of tradeoff studies evaluating the impact of spectral resolution, spectral coverage, instrument noise, and a priori knowledge on remote sensing system information content, with a specific emphasis on thermodynamic state and trace species information obtainable from advanced atmospheric sounders. Particular attention will be devoted toward information achievable from the Atmospheric InfraRed Sounder (AIRS) on the NASA EOS Aqua satellite in orbit since 2002, the Infrared Atmospheric Sounding Interferometer (IASI) aboard MetOp-A since 2006, and the Cross-track Infrared Sounder (CrIS) instrument to fly aboard the NPP and JPSS series of satellites expected to begin in late 2011. While all of these systems cover nearly the same infrared spectral extent, they have very different number of channels, instrument line shapes, coverage continuity, and instrument noise. AIRS is a grating spectrometer having 2378 discrete spectral channels ranging from about 0.4 to 2.2/cm resolution; IASI is a Michelson interferometer with 8461 uniformly-spaced spectral channels of 0.5/cm (apodized) resolution; and CrIS is a Michelson interferometer having 1305 spectral channels of 0.625, 1.250, and 2.50/cm (unapodized) spectral resolution, respectively, over its three continuous but non-overlapping bands. Results of tradeoff studies showing information content sensitivity to assumed measurement system characteristics will be presented.

Larar, Allen M.↗

Fiberoptics technology and its application to propulsion control systems

Current work on optical sensors and optically controlled actuators for use in air-breathing engine control systems is reviewed with particular reference to the design and operation of several new fiber-optic devices. These include a tachometer, a rotary position encoder, a Fabry-Perot interferometer and a rare-earth sensor for measuring engine gas temperatures, a high-temperature photoswitch designed for the range -55 to 260 C, and optical cables and connectors. The advantages of optics over conventional wire systems used for sensing and actuator control are briefly discussed.

Baumbick, R. J.↗

Probing the antisymmetric Fano interference assisted by a Majorana fermion

As the Fano effect is an interference phenomenon where tunneling paths compete for the electronic transport, it becomes a probe to catch fingerprints of Majorana fermions lying on condensed matter systems. In this work, we benefit of this mechanism by proposing as a route for that an Aharonov-Bohm-like interferometer composed by two quantum dots, being one of them coupled to a Majorana bound state, which is attached to one of the edges of a semi-infinite Kitaev wire within the topological phase. By changing the Fermi energy of the leads and the symmetric detuning of the levels for the dots, we show that opposing Fano regimes result in a transmittance characterized by distinct conducting and insulating regions, which are fingerprints of an isolated Majorana quasiparticle. Furthermore, we show that the maximum fluctuation of the transmittance as a function of the detuning is half for a semi-infinite wire, while it corresponds to the unity for a finite system. The setup proposed here constitutes an alternative experimental tool to detect Majorana excitations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Astronomy on a manned Mars mission

Three extra-solar-system astronomical experiments onboard a manned Mars mission are proposed. First, a modest, 50 cm aperture optical-ultraviolet-infrared telescope (or pair used as an interferometer) coupled with the Mars-Sun baseline would increase the number (by a factor of 3.4) and a volume of stars with accurately measured distances via stellar parallax and, therefore, greatly improve upon the cosmic distance scale; the darker sky at Mars would also provide nearly a full astronomical magnitude deeper images of distant and low brightness objects (limited by zodiacal light). Second, a gamma-ray burst detector coupled with similar detectors in other parts of the solar system will be used to reduce the position error boxes and to study the nature of these energetic sources. Third, the long baselines on a Mars mission radio interferometer will provide a view of the radio universe at unprescedented resolution, 4 x 10 to the minus 9th arcsec at 1 mm wavelength, which can potentially resolve the engine in nearby active galaxies. Each of these experiments is relatively inexpensive, taking advantage of the human presence for operation and maintenance, and the long Earth to Mars baseline.

Burns, Jack O.↗

FIRST VISUAL ORBIT FOR THE PROTOTYPICAL COLLIDING-WIND BINARY WR 140

Wolf-Rayet (WR) stars represent one of the final stages of massive stellar evolution. Relatively little is known about this short-lived phase and we currently lack reliable mass, distance, and binarity determinations for a representative sample. Here we report the first visual orbit for WR 140 (= HD193793), a WC7+O5 binary system known for its periodic dust production episodes triggered by intense colliding winds near periastron passage. The Infrared-Optical Telescope Array and Center for High Angular Resolution Astronomy interferometers resolved the pair of stars in each year from 2003 to 2009, covering most of the highly eccentric, 7.9 year orbit. Combining our results with the recently improved double-line spectroscopic orbit of Fahed et al., we find the WR 140 system is located at a distance of 1.67 {+-} 0.03 kpc, composed of a WR star with M{sub WR} = 14.9 {+-} 0.5 M{sub Sun} and an O star with M{sub O} = 35.9 {+-} 1.3 M{sub Sun }. Our precision orbit yields key parameters with uncertainties {approx}6 Multiplication-Sign smaller than previous work and paves the way for detailed modeling of the system. Our newly measured flux ratios at the near-infrared H and Ks bands allow a spectral energy distribution decomposition and analysis of the component evolutionary states.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from SIM's Thermo-Opto-Mechanical (TOM3) Testbed

Future space-based optical interferometers, such as the Space Interferometer Mission Planet Quest (SIM), require thermal stability of the optical wavefront to the level of picometers in order to produce astrometric data at the micro-arc-second level. In SIM, the internal path of the interferometer will be measured with a small metrology beam whereas the starlight fringe position is estimated from a large concentric annular beam. To achieve the micro-arc-second observation goal for SIM, it is necessary to maintain the optical path difference between the central and the outer annulus portions of the wavefront of the front-end telescope optics to a few tens of picometers. The Thermo-Opto-Mecha nical testbed (TOM3) was developed at the Jet Propulsion Laboratory to measure thermally induced optical deformations of a full-size flight-like beam compressor and siderostat, the two largest optics on SIM, in flight-like thermal environments. A Common Path Heterodyne Interferometer (COPHI) developed at JPL was used for the fine optical path difference measurement as the metrology sensor. The system was integrated inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. The siderostat was installed in a temperature-controlled thermal shroud inside the vacuum chamber, creating a flight-like thermal environment. Detailed thermal and structural models of the test articles (siderostat and compressor) were also developed for model prediction and correlation of the thermal deformations. Experimental data shows SIM required thermal stability of the test articles and good agreement with the model predictions.

interferometry↗

SIM PlanetQuest: Mili-Kelvin Analysis of the Collector Sub-system Thermal Model

Space Interferometry Mission (SIM) PlanetQuest is part of the NASA Astronomical Search for Origins (ASO) program. It will use a Michelson Interferometer to locate extrasolar planets, among other objectives. The spacecraft's subsystems, temperature requirements, and thermal control approach are discussed. The current SIM thermal design is analyzed using a Milli-Kelvin approach and appears to meet temperature stability requirements on the OOPCC optic. SIM absolute temperature requirements are met through the robustness of the thermal design (i.e., PIC control).

PlanetQuest↗

DETECTION OF IMBHs WITH GROUND-BASED GRAVITATIONAL WAVE OBSERVATORIES: A BIOGRAPHY OF A BINARY OF BLACK HOLES, FROM BIRTH TO DEATH

Even though the existence of intermediate-mass black holes (IMBHs; black holes with masses ranging between 10{sup 2} M{sub sun} and 10{sup 4} M{sub sun}) has not yet been corroborated observationally, these objects are of high interest for astrophysics. Our understanding of the formation and evolution of supermassive black holes, as well as galaxy evolution modeling and cosmography would dramatically change if an IMBH were to be observed. From the point of view of traditional photon-based astronomy, which relies on the monitoring of innermost stellar kinematics, the direct detection of an IMBH seems to be rather far in the future. However, the prospect of the detection and characterization of an IMBH has good chances in lower frequency gravitational-wave (GW) astrophysics using ground-based detectors such as the Laser Interferometer Gravitational-Wave Observatory (LIGO), Virgo, and the future Einstein Telescope (ET). We present an analysis of the signal of a system of a binary of IMBHs based on a waveform model obtained with numerical relativity simulations coupled with post-Newtonian calculations at the highest available order. IMBH binaries with total masses between 200 and 20,000 M{sub sun} would produce significant signal-to-noise ratios in Advanced LIGO and Virgo and the ET. We have computed the expected event rate of IMBH binary coalescences for different configurations of the binary, finding interesting values that depend on the spin of the IMBHs. The prospects for IMBH detection and characterization with ground-based GW observatories would not only provide us with a robust test of general relativity, but would also corroborate the existence of these systems. Such detections should allow astrophysicists to probe the stellar environments of IMBHs and their formation processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Performance of the Keck Angle Tracker

The Keck Angle Tracker (KAT) is a key subsystem in the NASA-funded Keck Interferometer at the Keck Observatory on the summit of Mauna Kea in Hawaii. KAT, which has been in operation since the achievement of first fringes in March 2001, senses the tilt of the stellar wavefront for each of the beams from the interferometer telescopes and provides tilt error signals to fast tip/tilt mirrors for high-bandwidth, wavefront tilt correction. In addition, KAT passes low-bandwidth, desaturation offsets to the adaptive optics system of the Keck telescopes to correct for slow pointing drifts. We present an overview of the instrument design and recent performance of KAT in support of the V2 science and nulling observing modes of the Keck Interferometer.

adaptive optics↗

Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.

43 PARTICLE ACCELERATORS↗

MIT's interferometer CST testbed

The MIT Space Engineering Research Center (SERC) has developed a controlled structures technology (CST) testbed based on one design for a space-based optical interferometer. The role of the testbed is to provide a versatile platform for experimental investigation and discovery of CST approaches. In particular, it will serve as the focus for experimental verification of CSI methodologies and control strategies at SERC. The testbed program has an emphasis on experimental CST--incorporating a broad suite of actuators and sensors, active struts, system identification, passive damping, active mirror mounts, and precision component characterization. The SERC testbed represents a one-tenth scaled version of an optical interferometer concept based on an inherently rigid tetrahedral configuration with collecting apertures on one face. The testbed consists of six 3.5 meter long truss legs joined at four vertices and is suspended with attachment points at three vertices. Each aluminum leg has a 0.2 m by 0.2 m by 0.25 m triangular cross-section. The structure has a first flexible mode at 31 Hz and has over 50 global modes below 200 Hz. The stiff tetrahedral design differs from similar testbeds (such as the JPL Phase B) in that the structural topology is closed. The tetrahedral design minimizes structural deflections at the vertices (site of optical components for maximum baseline) resulting in reduced stroke requirements for isolation and pointing of optics. Typical total light path length stability goals are on the order of lambda/20, with a wavelength of light, lambda, of roughly 500 nanometers. It is expected that active structural control will be necessary to achieve this goal in the presence of disturbances.

Hyde, Tupper↗

Space Interferometry Mission (SIM): Overview and current status

The Space Interferometry Mission (SIM) will be the first in-space, long-baseline Michelson Stellar Interferometer. SIM will perform precision astrometry at the micro-arcsecond accuracy level, which will be used to characterize planetary systems around stars within about ten parsecs of Earth and address a number of other key astrophysics projects. This paper provides a broad overview of the SIM Mission. Topics covered include: the science objectives, key top level requirements, how the mission will be implemented (technical and programmatic), technology development status, who the key players are in the SIM development, an assessment of where the project is today, and prognosis for the future.

interferometer↗

Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

Sullenberger, Ryan M.↗

Unveiling contextual realities by microscopically entangling a neutron

The development of qualitatively new measurement capabilities is often a prerequisite for critical scientific and technological advances. Here we introduce an unconventional quantum probe, an entangled neutron beam, where individual neutrons can be entangled in spin, trajectory and energy. The spatial separation of trajectories from nanometers to microns and energy differences from peV to neV will enable investigations of microscopic magnetic correlations in systems with strongly entangled phases, such as those believed to emerge in unconventional superconductors. We develop an interferometer to prove entanglement of these distinguishable properties of the neutron beam by observing clear violations of both Clauser-Horne-Shimony-Holt and Mermin contextuality inequalities in the same experimental setup. Our work opens a pathway to a future of entangled neutron scattering in matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗