Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Detection of Synchrophasor False Data Injection Attack using Feature Interactive Network

The synchrophasor data recorded by Phasor Measurement Units (PMUs) plays an increasingly critical role in the regulation and situational awareness of power systems. However, the widely installed PMUs are vulnerable to multiple malicious attacks from cyber hackers during data transmission and storage. To address this problem, a Modified Ensemble Empirical Mode Decomposition (MEEMD) is proposed first to extract the intrinsic mode functions of each Synchrophasor Data Attacks (SDA). The frequency-based adaptive screening criterion embedded in MEEMD is used to eliminate the false intrinsic mode functions. Next, a Multivariate Convolutional Neural Network (MCNN) is proposed to identify multiple SDA by utilizing the extracted intrinsic mode functions and original SDA as input vectors. A fusion block as the main structure of MCNN is also leveraged to increase the diversity of features and compress the model parameters. Integrating MEEMD and MCNN, a framework with automatic feature extraction and multi-source information fusion capability, referred to as Feature Interactive Network (FIN), is proposed to detect multiple SDA. Based on the proposed FIN framework, six types of SDA are explored for the first time using actual synchrophasor data in FNET/Grideye that was collected from different locations in the U.S. Eastern Interconnection. Finally, a large quantity of experiments with different attack strengths are used to evaluate the adaptability and classification performance of the proposed FIN.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Speed to Power: Solutions for Accelerating Large Load Connections

Rapid growth in demand from data centers and other large loads is creating a range of new challenges for electricity planners, investors, system operators, and regulators, leading to bottlenecks that have slowed connection of large loads to the electric grid. In response, innovative solutions for accelerating large load connections are beginning to emerge across the U.S. Drawing on an extensive document and literature review, this report identifies more than 40 potential solutions for accelerating large load connections, organized into five functional areas: load forecasting, interconnection, resource planning and procurement, markets and operations, and cost allocation and ratemaking. The five functional areas provide a framework for organizing challenges and solutions to large load connection bottlenecks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing Energy Efficient Communication Runtime Systems for Data Centric Programming Models

The insatiable demand of high performance computing is being driven by the most computationally intensive applications such as computational chemistry, climate modeling, nuclear physics, etc. The last couple of decades have observed a tremendous rise in supercomputers with architectures ranging from traditional clusters to system-on-a-chip in order to achieve the petaflop computing barrier. However, with advent of petaflop-plus computing, we have ushered in an era where power efficient system software stack is imperative for execution on exascale systems and beyond. At the same time, computationally intensive applications are exploring programming models beyond traditional message passing, as a combination of Partitioned Global Address Space (PGAS) languages and libraries, providing one-sided communication paradigm with put, get and accumulate primitives. To support the PGAS models, it is critical to design power efficient and high performance one-sided communication runtime system. In this paper, we design and implement PASCoL, a high performance power aware one-sided communication library using Aggregate Remote Memory Copy Interface (ARMCI), the communication runtime system of Global Arrays. For various communication primitives provided by ARMCI, we study the impact of Dynamic Voltage/Frequency Scaling (DVFS) and a combination of interrupt (blocking)/polling based mechanisms provided by most modern interconnects. We implement our design and evaluate it with synthetic benchmarks using an InfiniBand cluster. Our results indicate that PASCoL can achieve significant reduction in energy consumed per byte transfer without additional penalty for various one-sided communication primitives and various message sizes and data transfer patterns.

99 GENERAL AND MISCELLANEOUS↗

Electron Ion Collider Machine Protection System: Requirements for an Electron Storage Ring abort system

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous hazards and risks of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

2022 Peer Review Project Summary: Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (mediumvoltage) level may also become common as a means for improving distribution reliability and resilience. The objective of this multiyear project is to increase the adoption of microgrids in secondary networks and meshed distribution systems by developing novel protection schemes that allow for safe reliable operation of DERs in secondary networks. We will address these challenges by working with the appropriate stakeholders of secondary network operators, protection vendors, and standards committee. The outcomes of this project include: a) development and/or demonstration of candidate methods for enabling protection of secondary networks containing high levels of DER; b) development of modeling and testing tools for protection systems designed for use with secondary networks including DERs; and c) development of new industrial partnerships to facilitate widespread results dissemination and eventual commercialization of results as appropriate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Canopy Expansion Project (Final Technical Report)

This project is a parking-lot canopy solar photovoltaic system, consisting of four canopy structures and 1,080 470-watt (W) modules. The nameplate rating of the project is 507.6 kilowatts direct current (kWDC) at Standard Test Condition (STC), and 448 kilowatts alternating current (kWAC). It is interconnected to the existing Tribe-owned medium-voltage micro-grid generation system via a step-up transformer and short medium-voltage line. This project offsets energy usage from more expensive existing sources, specifically the Tribe-owned gas-fired engine generators providing the primary power source for existing Tribal facilities and the electric utility, which provides an alternate source. The solar photovoltaic system is a renewable source, which has the benefit of reducing reliance on fossil-fuel burning sources. By reducing demand on existing Tribe-owned conventional generators, the project has avoided the need to add more conventional generation and has prolonged the lifespan of existing gas-fired engine generators. The project reduced energy costs and reliance on fossil-fuel burning power sources, increasing Tribe-owned generating sources and self-reliance, and prolonging the lifespan of existing generators. A side benefit to the project is the production of dozens of covered parking spaces in the existing parking lot.

14 SOLAR ENERGY↗

Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (medium-voltage) level may also become common as a means for improving distribution reliability and resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Energy Grids

Current frameworks to monitor, control, and optimize large-scale energy systems are becoming increasingly inadequate because of significantly high penetration levels of variable generation and distributed energy resources being integrated into electric power systems; the deluge of data from pervasive metering of energy grids; and a variety of new market mechanisms, including multilevel ancillary services. This paper outlines the concept of autonomous energy grids (AEGs). These systems are supported by a scalable, reconfigurable, and self-organizing information and control infrastructure, are extremely secure and resilient (self-healing), and can self-optimize in real time to ensure economic and reliable performance while systematically integrating energy in all forms. AEGs rely on cellular building blocks that can self-optimize when isolated from a larger grid and participate in optimal operation when interconnected to a larger grid. This paper describes the key concepts and research necessary in the broad domains of optimization theory, control theory, big data analytics, and complex system theory and modeling to realize the AEG vision.

autonomous energy grids↗

Fast Quasi-Static Time-Series (QSTS) for yearlong PV impact studies using vector quantization

The rapidly growing penetration levels of distributed photovoltaic (PV) systems requires more comprehensive studies to understand their impact on distribution feeders. IEEE P.1547 highlights the need for Quasi-Static Time Series (QSTS) simulation in conducting distribution impact studies for distributed resource interconnection. Unlike conventional scenario-based simulation, the time series simulation can realistically assess time-dependent impacts such as the operation of various controllable elements (e.g. voltage regulating tap changers) or impacts of power fluctuations. However, QSTS simulations are still not widely used in the industry because of the computational burden associated with running yearlong simulations at a 1-s granularity, which is needed to capture device controller effects responding to PV variability. This study presents a novel algorithm that reduces the number of times that the non-linear 3-phase unbalanced AC power flow must be solved by storing and reassigning power flow solutions as it progresses through the simulation. Each unique power flow solution is defined by a set of factors affecting the solution that can easily be queried. We demonstrate a computational time reduction of 98.9% for a yearlong simulation at 1-s resolution with minimal errors for metrics including: number of tap changes, capacitor actions, highest and lowest voltage on the feeder, line losses, and ANSI voltage violations. Finally, the key contribution of this work is the formulation of an algorithm capable of: (i) drastically reducing the computational time of QSTS simulations, (ii) accurately modeling distribution system voltage-control elements with hysteresis, and (iii) efficiently compressing result time series data for post-simulation analysis.

14 SOLAR ENERGY↗

Testing interconnected VLSI circuits in the Big Viterbi Decoder

The Big Viterbi Decoder (BVD) is a powerful error-correcting hardware device for the Deep Space Network (DSN), in support of the Galileo and Comet Rendezvous Asteroid Flyby (CRAF)/Cassini Missions. Recently, a prototype was completed and run successfully at 400,000 or more decoded bits per second. This prototype is a complex digital system whose core arithmetic unit consists of 256 identical very large scale integration (VLSI) gate-array chips, 16 on each of 16 identical boards which are connected through a 28-layer, printed-circuit backplane using 4416 wires. Special techniques were developed for debugging, testing, and locating faults inside individual chips, on boards, and within the entire decoder. The methods are based upon hierarchical structure in the decoder, and require that chips or boards be wired themselves as Viterbi decoders. The basic procedure consists of sending a small set of known, very noisy channel symbols through a decoder, and matching observables against values computed by a software simulation. Also, tests were devised for finding open and short-circuited wires which connect VLSI chips on the boards and through the backplane.

Onyszchuk, I. M.↗

Continuous roll-to-roll fabrication of organic photovoltaic cells via interconnected high-vacuum and low-pressure organic vapor phase deposition systems

We demonstrate continuous roll-to-roll (R2R) fabrication of single junction and tandem organic photovoltaic (OPV) cells on flexible plastic substrates employing a system that integrates organic deposition by high vacuum thermal evaporation (VTE) and low pressure organic vapor phase deposition (OVPD). By moving the substrate from chamber to chamber and then depositing films on stationary substrates, we achieve power conversion efficiencies of PCE = 8.6 ± 0.3% and 8.9 ± 0.2% for the single junction and tandem cells, respectively. Single junction OPVs are also fabricated on a continuously translating substrate at 0.3 cm/s, to achieve PCE = 8.5 ± 0.2%. Thin films grown on translating substrates by OVPD show <3% thickness non-uniformity and 0.66 nm root mean square surface roughness, similar to that obtained by VTE. Our results suggest that R2R film deposition comprising multiple vapor deposition technologies is a promising method for rapid speed and continuous manufacturing of high quality, small molecular weight organic electronic materials.

42 ENGINEERING↗

Optimal interconnection of three-terminal tandem solar cells

Three-terminal (3T) tandem solar cells require an adapted module integration scheme in order to explore their full efficiency potential. The three terminals allow to extract the power of the top and bottom cell separately. In a cell string, the wide bandgap top cells are interconnected in parallel to multiple bottom cells resulting in a parallel/series interconnection. This interconnection scheme affects the operation of the subcells, the resulting current path between the subcells, the layout of the cell interconnects, and the system level. Here, we analyze by simulations and experiments the aspects of the module integration of series- and reverse-connected 3T cells with their practical impact on module processes and performance as well as the effect of varying voltage ratios on the string-end losses. If the subcells are connected in series, the module integration requires insulation layers and significantly longer interconnects compared to devices with reverse-connected subcells. Tandem devices with a reverse connection and a voltage ratio between top and bottom cell of 2:1 allow a lean interconnection design and low integration losses. Here, we present an approach for the integration of bypass diodes for the protection against shading effects that allow to minimize string-end and shading losses for a system of modules featuring 3T cells.

14 SOLAR ENERGY↗

Hydropower operation in future power grid with various renewable power integration

Hydropower generation may play an increasingly important role in the power grid under increasing contribution of variable renewable sources such as wind and solar. An improved understanding of the changes to hydropower dispatch under future higher VRE grid conditions reveals research gap that should be informed power grid planning and reservoir water releases policies considering multiple other water uses and varying hydrologic condition. Here this study aims to understand the role of hydropower in a changing power grid by employing a production cost model, PLEXOS, across future power system scenarios, planning horizons, and regions. We explore optimized hydropower dispatch to understand its potential role in minimizing the system cost and renewable curtailment. We also examine the sensitivity of hydropower revenue under various grid scenarios of the Eastern U.S. and hydrology conditions. Results indicate hydropower generation follows net load and compensates for the variability of solar and wind generation. Although energy prices are lower during some periods in the future grid scenarios, there is a potential for higher revenue for hydropower by providing both energy and ancillary services during times of stress. Additionally, hydropower revenue is sensitive to hydrology in the SERC region, which we considered as an example. The feasibility of hydropower dispatching with higher ramps between low and high hourly-capacity factors, as indicated in the optimization model, requires further study to consider other water use and ecology constraints.

13 HYDRO ENERGY↗

Performance Analysis of Deep Learning Workloads on Leading-edge Systems

This work examines the performance of leading-edge systems designed for machine learning computing, including the NVIDIA DGX-2, Amazon Web Services (AWS) P3, IBM Power System Accelerated Compute Server AC922, and a consumer-grade Exxact TensorEX TS4 GPU server. Representative deep learning workloads from the fields of computer vision and natural language processing are the focus of the analysis. Performance analysis is performed along with a number of important dimensions. Performance of the communication interconnects and large and high-throughput deep learning models are considered. Different potential use models for the systems as standalone and in the cloud also are examined. The effect of various optimization of the deep learning models and system configurations is included in the analysis.

97 MATHEMATICS AND COMPUTING↗

North Antelope Highlands Wind Project

This is the final report on the Wind Energy Development of 190 Mw on the Rosebud Indian Reservation in collaboration with Citizens Energy Corporation. The report discusses all pre-development activities since July of 2010 when award was granted. A systems impact study along with wind data accumulated over the past 5 years is contained in this report. We have responded to several RFPs concerning the sale of energy to certain offtakers, but we have failed to win a Power Purchase Agreement due to existing wind farms that won and the interconnection costs were already included in a previous PPAs, which we don't have that luxury. We continue this effort and hopefully in the near future we will win an RFP.

17 WIND ENERGY↗

Tehachapi Wind Energy Storage Project - Technology Performance Report #3

The TSP is located at SCE’s Monolith Substation in Tehachapi, California. The 8 MW, 4 hours (32 MWh) BESS is housed in a 6,300 square foot facility and 2 x 4 MW/4.5 MVA smart inverters are on a concrete pad adjacent to the BESS facility. The project will evaluate the capabilities of the BESS to improve grid performance and assist in the integration of large-scale intermittent generation, e.g., wind. Project performance was measured by 13 specific operational uses: providing voltage support and grid stabilization, decreasing transmission losses, diminishing congestion, increasing system reliability, deferring transmission investment, optimizing renewable-related transmission, providing system capacity and resources adequacy, integrating renewable energy (smoothing), shifting wind generation output, frequency regulation, spin/non-spin replacement reserves, ramp management, and energy price arbitrage. Most of the operations either shift other generation resources to meet peak load and other electricity system needs with stored electricity, or resolve grid stability and capacity concerns that result from the interconnection of intermittent generation. SCE also demonstrated the ability of lithium ion battery storage to provide nearly instantaneous maximum capacity for supply-side ramp rate control to minimize the need for fossil fuel-powered back-up generation. The project began in October, 2010 and will continue through December, 2016.

25 ENERGY STORAGE↗

Cybersecurity Assessments on Emulated DER Communication Networks

An increasing number of public utility commissions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. The recently updated national standard, IEEE 1547-2018, requires all DER to include a Sun Spec Modbus, IEEE 2030.5, or IEEE 1815 communication interface in order to provide local and bulk power system services. Those communication protocols and associated information models will ensure system interoperability for PV and storage systems, but these new utility-to-DER communication networks must be deployed with sufficient cybersecurity to protect the U.S. power system and other critical infrastructure reliant on dependable power. Unlike bulk generators, DER are commonly connected to grid operators via public internet channels. These DER networks are exposed to a large attack surface that may leverage sophisticated techniques and infrastructure developed on IT systems, including remote exploits and distributed attacks. Although DER make up a growing portion of the national generation mix, they have limited processing capabilities and do not typically support modern security features such as encryption or authentication. In this work, Sandia National Laboratories constructed simulated DER communication net- works with a range of security features in order to study the security posture of different communication approaches. The experimental test environment was created in a Sandia-developed co-simulation platform, called SCEPTRE, which emulated Sun Spec-compliant DER equipment, the utility DER management system, communication network, and distribution power system. Adversary-based assessments were conducted and a quantitative scoring criteria was applied to evaluate the resilience of various architectures against cyber attacks and to measure the systemic impact during such attacks. The team found that network segmentation, encryption, and moving target defense improved the security of these networks and would be recommended for utility, aggregator, and local DER networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗