Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Changes in Exercise Data Management

The suite of exercise hardware aboard the International Space Station (ISS) generates an immense amount of data. The data collected from the treadmill, cycle ergometer, and resistance strength training hardware are basic exercise parameters (time, heart rate, speed, load, etc.). The raw data are post processed in the laboratory and more detailed parameters are calculated from each exercise data file. Updates have recently been made to how this valuable data are stored, adding an additional level of data security, increasing data accessibility, and resulting in overall increased efficiency of medical report delivery. Questions regarding exercise performance or how exercise may influence other variables of crew health frequently arise within the crew health care community. Inquiries over the health of the exercise hardware often need quick analysis and response to ensure the exercise system is operable on a continuous basis. Consolidating all of the exercise system data in a single repository enables a quick response to both the medical and engineering communities. A SQL server database is currently in use, and provides a secure location for all of the exercise data starting at ISS Expedition 1 - current day. The database has been structured to update derived metrics automatically, making analysis and reporting available within minutes of dropping the inflight data it into the database. Commercial tools were evaluated to help aggregate and visualize data from the SQL database. The Tableau software provides manageable interface, which has improved the laboratory's output time of crew reports by 67%. Expansion of the SQL database to be inclusive of additional medical requirement metrics, addition of 'app-like' tools for mobile visualization, and collaborative use (e.g. operational support teams, research groups, and International Partners) of the data system is currently being explored.

Buxton, R. E.↗

NASA's Bio-Inspired Acoustic Absorber Concept

Transportation noise pollutes our worlds cities, suburbs, parks, and wilderness areas. NASAs fundamental research in aviation acoustics is helping to find innovative solutions to this multifaceted problem. NASA is learning from nature to develop the next generation of quiet aircraft.The number of road vehicles and airplanes has roughly tripled since the 1960s. Transportation noise is audible in nearly all the counties across the US. Noise can damage your hearing, raise your heart rate and blood pressure, disrupt your sleep, and make communication difficult. Noise pollution threatens wildlife when it prevents animals from hearing prey, predators, and mates. Noise regulations help drive industry to develop quieter aircraft. Noise standards for aircraft have been developed by the International Civil Aviation Organization and adopted by the US Federal Aviation Administration. The US National Park Service is working with the Federal Aviation Administration to try to balance the demand for access to the parks and wilderness areas with preservation of the natural soundscape. NASA is helping by conceptualizing quieter, more efficient aircraft of the future and performing the fundamental research to make these concepts a reality someday. Recently, NASA has developed synthetic structures that can absorb sound well over a wide frequency range, and particularly below 1000 Hz, and which mimic the acoustic performance of bundles of natural reeds. We are adapting these structures to control noise on aircraft, and spacecraft. This technology might be used in many other industrial or architectural applications where acoustic absorbers have tight constraints on weight and thickness, and may be exposed to high temperatures or liquids. Information about this technology is being made available through reports and presentations available through the NASA Technical Report Server, http:ntrs.nasa.gov. Organizations who would like to collaborate with NASA or commercialize NASAs technology are encouraged to contact the NASA Glenn Technology Transfer Office, https:technology.grc.nasa.gov. The NASA Glenn Office of Education https:www.nasa.govcentersglenneducationindex.html and the NASA Glenn Virtual Interchange for Nature-Inspired Exploration https:www.grc.nasa.govvine are also helping to make research like this accessible to the public and students of all ages.

Acoustics↗

Miniature Exercise Device-2 (MED-2): Preliminary ISS Evaluation Results for a Compact Motorized Resistive and Aerobic Rowing Exercise Device

Future human missions beyond Low Earth Orbit (LEO) will require onboard equipment to provide exercise capabilities for the crew to counter the adverse physiological effects of long-duration microgravity. To accomplish this within the physical constraints of a space vehicle or transit module, a single miniature device that provides both resistive and aerobic exercise modalities is required. To meet this need, Johnson Space Center’s (JSC) Software, Robotics, and Simulation Division (ER) developed the Miniature Exercise Device-2 (MED-2). MED-2 integrates a torque-controlled servomotor and a series-elastic actuator to provide highly-controllable load profiles and a large magnitude output performance in a very small package. This innovative technology is derived from years of JSC/ER design, development and operational experience with cutting-edge robotics, motor controllers, software and actuator/sensor miniaturization, including Robonaut 2 and MED-1. MED-2 was presented at the 2016 ISS R&D Conference. This is an update now that the last of six crewmembers will have completed planned MED-2 sessions on the International Space Station (ISS) in May 2018.Current state-of-the-art ISS exercise equipment consists of two treadmills, a resistive exercise device and two cycle ergometers with a total mass of several thousand pounds and a total volume of several cubic yards. This equipment has proven vital to mitigate the musculoskeletal and cardiovascular degradation effects of microgravity. However, due to the large operational volume and mass of these ISS devices, tailoring them for smaller vehicles, such as Orion, is not possible. In addition, each of the current ISS devices targets a single specific modality. Compared to the existing spaceflight (and even terrestrial) exercise equipment, MED-2 is a new archetype altogether. The combined features of compact size, multi-modality and high-performance is attributable to its innovative series elastic actuator and motor controller. Following its arrival on ISS in 2016, MED-2 was evaluated in two parts. The first and shorter evaluation was an engineering functional checkout of the hardware. As this was a novel exercise device previously never used on ISS, the initial checkout assessed the operation of the hardware and ensured the motion and dynamic range of the crew did not present any collision or other hazards. The second portion of the study collected the heart rates, kinematics and utilized operational volumes of six astronauts to determine the quality of both the resistive and aerobic exercise modalities as delivered by MED-2. Investigators from JSC Biomedical Research and Environmental Science Division (SK) and Glenn Research Center are currently evaluating the data and preparing preliminary results. For the resistive exercise modality, MED-2 demonstrated a range of constant resistive loads from 10-150 lbf. With a displacement range of 84 inches, the MED-2 accommodates users from 5th percentile Japanese female through 95th percentile American male for all of its certified exercises. The displacement measurement accuracy has also been verified within 2.5 percent full range. The crew was able to successfully perform all prescribed resistive exercises, except Goblet Squats which were not feasible with a constant load profile. For the aerobic exercise modality, MED-2 simulated a rowing motion with prescribed and user-selected resistance levels. It has demonstrated rates up to 60 strokes per minute on the ground. MED-2 loads and displacements performance are the same as those cited for the resistive modality. Although each of the crew was able to perform the prescribed aerobic rowing sets, there was considerable variability in the rowing motion among different crewmembers. Also, as expected, the crew was unable to get the full benefits of a typical terrestrial rowing stroke because the current configuration does not allow the user to reach past their feet. These observations have already informed the requirements for other microgravity rowing devices currently in development. One of the unique features of the MED-2 device is the intuitive touch-screen control system. This One Portal graphical user interface (GUI) was developed based on JSC/ER’s heritage knowledge and experience of developing and sustaining the current ISS exercise equipment. Through this interface, the crew easily performed prepared prescriptions as well as had the ability to adjust exercise modality, load and other exercise details such as number of repetitions and number of sets. This touch-screen and GUI fulfilled the MED-2 project goal to simplify the interaction between the user and the device. Furthermore, the extent to which MED-2 utilizes a touchscreen and GUI to control exercise equipment is unmatched among the existing ISS exercise devices. As a motorized device, MED-2 technology can provide a customizable force profile that can be varied as a function of strap displacement, strap velocity or a combination of these and other variables. During 2017, JSC/ER developed and flight-certified a resistive exercise algorithm that mimics the 1-G inertial effects of free-weights and enables adjustable eccentric-to-concentric loading ratios. Subsequent development will explore varying the load profiles and incorporating additional exercises beyond the current list of certified movements.

Exercise↗

Changes in Exercise Data Management

The suite of exercise hardware aboard the International Space Station (ISS) generates an immense amount of data. The data collected, treadmill, cycle ergometer, and resistance strength training hardware, are basic exercise parameters (time, heart rate, speed, load, etc.). The raw data are processed in the laboratory and more detailed parameters are calculated from each exercise data file. Updates recently have been made to how these valuable data are stored, adding an additional level of security, increasing accessibility, and resulting in overall increased efficiency of medical report delivery. Questions regarding exercise performance or how exercise may influence other variables of crew health frequently arise within the crew health care community. Inquiries regarding the health of the exercise hardware often need quick analysis and response to ensure the exercise system is operable on a continuous basis. Consolidating all of the exercise system data in a single repository enables a quick response to both the medical and engineering communities. A SQL server database is currently in use, and provides a secure location for all of the exercise data starting at ISS Expedition 1 to current date. The database has been structured to update derived metrics automatically, making analysis and reporting available within minutes of dropping the in-flight data into the database. Commercial tools were evaluated to help aggregate and visualize data from the SQL database. The Tableau software provides manageable interface, which has improved the laboratory’s output time of crew reports by 67%. Expansion of the SQL database, to be inclusive of additional medical requirement metrics, addition of ‘app-like’ tools for mobile visualization, and collaborative use (e.g., operational support teams, research groups, and International Partners) of the data system, is currently being explored.

Buxton, R. E.↗

Medical Decision Making in the Physician Hierarchy: A Pilot Pedagogical Evaluation

Context: Recently, The American College of Graduate Medical Education (ACGME) has included the medical decision making as a core competency in several specialties. To date, the ability to demonstrate and measure a pedagogical evolution of medical judgment in a medical education program has been limited. Objective: In this study we hope to examine differences in medical decision making ability of different physicians across their various stages of post-graduate hierarchy. Method: Physcians spanning a wide spectrum of scientific disciplines were recruited for three catagories: administrative physicians(AP) representing physcians with the most experience but mostly practice administratively; resident physicians completing their postgraduate medical training (RP) and seasoned attending physicians with mastery level experience (MP). Participants completed four medical simulations focused on abdominal pain: cholecystitis (CH) and renal colic(RC) and chest pain; Cardiac ischemia (STEMI) and pneumothorax (PX). Simulation were ordered randomly so that there was no systematic bias due to learning or to fatigue. The Medical judgment metric (MJM) was used to evaluate medical decision-making. Results: There were no significant differences between the AP, RP, and MP groups in the gender, race, ethnicity, education, and baseline heart rate. There was a significant (p=0.002) interaction effect for simulation time and RP group, 6.2 minutes (+/-1.58); MP group, 8.7 minutes (+/-2.46); and AP group, 10.3 minutes (+/-2.78). The RC MJM scores were significantly (P=0.10) worse in the AP group 12.3 (+/-2.66) then the RP 14.7(+/-1.15) and MP17.7 (+/-1.15) groups. In every simulation, the AP group MJM scores were worse on average (no significantly) compared to the MP and RP groups. The AP group was significantly (P=0.040) less likely to stabilize the subject in the RC simulation than MP and RP groups. Conclusion: There remains significant variability in the medical education and skill retention influences medical decision making throughout a physician's career.

Rosasco, John↗

Pre-Flight Training of Autonomic Responses for Mitigating the Effects of Spatial Disorientation During Spaceflight

The National Aeronautics and Space Administration (NASA) has identified a potential risk of spatial disorientation, motion sickness, and degraded performance to astronauts during re-entry and landing of the proposed Orion crew vehicle. The purpose of this study was to determine if a physiological training procedure, Autogenic-Feedback Training Exercise (AFTE), can mitigate these adverse effects. Fourteen men and six women were assigned to two groups (AFTE, no-treatment Control) matched for motion sickness susceptibility and gender. All subjects received a standard rotating chair test to determine motion sickness susceptibility; three training sessions on a manual performance task; and four exposures in the rotating chair (Orion tests) simulating angular accelerations of the crew vehicle during re-entry. AFTE subjects received 2 hours of training before Orion tests 2, 3, and 4. Motion sickness symptoms, task performance, and physiological measures were recorded on all subjects. Results showed that the AFTE group had significantly lower symptom scores when compared to Controls on test 2 (p=.05), test 3 (p=.03), and test 4 (p=.02). Although there were no significant group differences on task performance, trends showed that AFTE subjects were less impaired than Controls. Heart rate change scores (20 revolutions per minute minus baseline) of AFTE subjects indicated significantly less reactivity on Test 4 compared to Test 1 (10.09 versus 16.59, p=.02), while Controls did not change significantly across tests. Results of this study indicate that AFTE may be an effective countermeasure for mitigating spatial dis-orientation and motion sickness in astronauts.

Orion↗

Cross-Cutting Computational Modeling Project: Exploration Medical Station Analysis

Astronauts will be away from Earth-based medical care for long periods during future exploration missions. Thus, it will be necessary for the astronauts to perform various medical tasks to monitor and maintain their health in the microgravity environment of space. Performance of these tasks will be constrained due to the limited volume available to perform the task, the absence of gravity and the limited resources and capabilities available in the medical work area. It is therefore necessary to evaluate exploration medical workstation designs for how well the designs will support crew performance of medical tasks. This evaluation featured two trained medical caregivers (99th percentile male, 26th percentile female) performing emergent care procedures (alone and in tandem) on a medical manikin. The procedures came from the The procedures came from the International Space Station Medical Checklist, and they are designed for spaceflight. The objectives of the evaluation included determining the operational volume required to perform the tasks, examining the effect of constraining the operational volume with partitions, determining candidate locations for foot restraints and equipment placements and determining the effect of single vs. dual caregiver on the operational volume.A marker-based motion capture system collected the motion data, which enabled computation of operational volumes and foot placement maps using custom Python code. Additional data collected included heart rate, time to perform the procedures, and feedback from the caregivers in the form of the NASA Task Load Index (TLX), the US Government System Usability Survey, and an open-ended questionnaire.

Christopher A Gallo↗

TPSAS-NF1676L-14834-DND

A recent spin-off from flight deck adaptive automation research at NASA Langley Research Center is a biocybernetic invention referred to informally as MindShift. When using the MindShift technology, a person is able to play off-the-shelf Nintendo Wii games enhanced with biofeedback, which is used to improve self-regulation of physiological functioning. Therefore, the user experiences the challenge of regulating their physiological responses during gameplay in addition to the intended challenges presented in the video game. The research projects being conducted under the supervision of Dr. Alan Pope and Chad Stephens at NASA Langley Research Center examine the effects of interacting with the MindShift invention technology on subjects' self-regulation of heart rate and brainwave activity, performance in the games, performance on cognitive tasks, and subjective experience of effort (i.e., workload). The MindShift invention's effects are being compared to the effects of interacting with the games without the MindShift technology and to the effects of interacting with commercial-off-the-shelf (COTS) brain-computer interface (BCI) technology, specifically the Mattel Mind Flex and the Uncle Milton Star Wars Force Trainer. A 32-channel electroencephalograph system is used to record subjects' brainwave and electrocardiographic activity. The potential for biofeedback game system applications is wide-ranging - from a more engaging form of clinical biofeedback training to a new challenge for avid gamers. Consequently, research needs to be conducted to fully understand the effects that these new games have on a person's physiological and psychological functioning. Biocybernetic technology like MindShift developed from the idea that operators of critical systems such as aerospace systems could hone their stress management and attention skills in biofeedback-augmented leisure activities while off-the-job in order to positively affect their on-the-job performance. This human performance enhancement technology is applicable to skill training on manually controlled critical tasks, such as unmanned aerial vehicle teleoperation, thus enabling the training of cognitive skills to be concurrent with manual skills. Furthermore, this type of technology can apply to medical and clinical uses of biofeedback by serving as an additional form of clinical biofeedback training that may be particularly useful for those with ADHD.

Brittany N Neilson↗

Motion Sickness and Concerns for Urban Air Mobility Vehicles: A Literature Review

Motion sickness is a general term for a constellation of signs and symptoms, generally due to exposure to abrupt, periodic, or unnatural accelerations, especially when traveling in a vehicle. Motion sickness results from a mismatch of the visual and nonvisual (vestibular and kinesthetic) information, the observed scene and the motion felt or lack of it. Motion sickness onset is associated with a pattern of physiological changes in heart rate, peripheral blood flow, respiration, and skin conductance and the pattern is repeatable for a particular subject but variable between subjects. Demographic factors such as gender and age that affect motion sickness are well known with children, women, and older adults more likely to be susceptible. Often motion sickness is assessed and quantified using variations of the motion sickness susceptibility questionnaires including the Pensacola Diagnostic Rating Scale and the Simulator Sickness Questionnaire. Even though symptoms are easily identified by such questionnaires, they commonly are subjective. Tools such as these questionnaires for screening individuals susceptible to motion sickness are useful, however, they are only mildly predictive. Moreover, models for predicting motion sickness, which have largely been developed for sea sickness, do not consider task characteristics. Predictions of motion sickness rates and prevalence for Urban Air Mobility (UAM) vehicles are not possible at present because data from actual flight or full-fidelity simulation are simply not yet available. Extrapolation from other modes of transportation (i.e., automobiles, buses, trains, boats, other types of aircraft) is difficult because of differences in the motion stimulus experienced, trip duration, and other factors. How UAM vehicles will change the social dynamics of passenger interaction and vehicle interior design changes (e.g., seat orientations) is unknown. Should motion sickness prove to be an issue, vehicle design modifications such as having passengers face forward, providing additional seat recline, giving each person their own climate control for airflow, perhaps ensuring the horizon is visible to all passengers (reducing visual occlusion by the headrest) and visually stabilizing displays on carry-on devices (smart phones, tablets, etc.) may benefit passengers. Several commercial companies provide wearable devices for physiological monitoring that have been validated and are suitable for use with passengers in UAM vehicles or high-fidelity simulators. Potential countermeasures for motion sickness include user-worn devices, anti-motion sickness medications, and non-pharmacological approaches such as biofeedback and Autogenic Feedback Training Exercise. Both simulator and in-vehicle UAM research is needed to evaluate the effectiveness of any potential countermeasure.

motion sickness↗

The problem of partial gravity on the Moon and Mars

Astronauts who spend many weeks or months in space in zero g suffer serious health problems including muscle atrophy, cardiovascular deconditioning, bone calcium loss, impaired vision, and immune system change. The debilitating effects of weightlessness were first demonstrated on the early Skylab, Salyut, and Mir missions, but it was too optimistically hoped that in-flight exercise and resistance training could prevent these problems. Similar problems are anticipated in the partial gravity of the Moon and Mars. Partial gravity exposure below 0.4 g seems too low to maintain musculoskeletal and cardiopulmonary conditioning in the long term. Some studies show a strong correlation between heart rate, oxygen consumption, net metabolic rate and simulated gravity from 0 to 1 g. Exposure to Moon and Mars gravities probably will cause less severe physiological deconditioning than experienced in 0 g, but the benefit of partial gravity seems likely to be roughly proportional to the 1/6 or 1/3 gravity experienced. As in 0 g, exercise countermeasures seem necessary but insufficient to preserve all physiological systems to a 1 g standard.

Harry W Jones↗

The Partial Gravity of the Moon and Mars Appears Insufficient to Maintain Human Health

Astronauts who spend many weeks or months in space in microgravity suffer serious health problems including muscle atrophy, cardiovascular deconditioning, bone calcium loss, impaired vision, and immune system changes. The debilitating effects of weightlessness were first demonstrated on the early Skylab, Salyut, and Mir missions, but it was then hoped that countermeasures including in-flight exercise and resistance training could reduce most of these problems. Similar effects are anticipated in the partial gravity of the Moon and Mars. Direct evidence of the long-term effects of partial gravity on humans is not yet available, but indirect evidence suggests that partial gravity exposure below 0.4 g will be insufficient to maintain musculoskeletal and cardiopulmonary conditioning over the long term. Some studies show a strong correlation between heart rate, oxygen consumption, net metabolic rate, and simulated gravity from 0 to 1 g. Exposure to moon and Mars gravities will probably cause less severe physiological deconditioning than microgravity, but the benefit of partial gravity seems likely to be roughly proportional to the level of gravity experienced. As in microgravity, exercise countermeasures seem useful but insufficient to preserve all physiological systems as they would be in Earth gravity.

Harry W. Jones↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks that are required by crews immediately after landing on a planetary surface are seat egress, jump, and walk. To be able to define an effective and comprehensive countermeasure strategy for preserving crew performance during exploration-class missions, there is a need to understand how these functional tasks are actually performed in partial gravity such as on the Moon or Mars. We propose to study the performance in the execution of these tasks during the partial gravity and hypergravity phases of parabolic flight. These tasks will be completed using the same equipment and procedures as the Standard Measures Sensorimotor protocol, which is performed by astronauts returning from spaceflight and by ground-based subjects after prolonged axial body unloading during bed rest. HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of vertical. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g and 10 parabolas at 0.75g. Subject also will perform tests in 1g between parabolas and in hypergravity (1.8g) during the pull-out phases. Subjects will perform the same tasks as those tested on astronauts returning from spaceflight: sit-to-stand and obstacle walk, tandem walk, jump down, and recovery from fall. Measurements will include: (a) the time for the subject to complete the test (sit-to-stand and obstacle walk, recovery from fall); (b) the time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) the mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) the percentage of correct steps and torso acceleration (tandem walk); and (f) the severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of 5 functional task tests in 0.25g, 0.5g, 0.75g, 1g, and 1.8g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. This comparison will help understanding the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element

Gilles Clement↗

How Environment and Operational Considerations Guide Requirements Development for Clinical Decision Support Beyond Low Earth Orbit

The Aerospace Medical community is acutely aware of the need for automated cognitive systems to support astronauts in responding to and making critical decisions about assessing – and treating - medical conditions and assuring wellness during exploration spaceflight missions. Such systems will be critically important to mission success as we venture farther from terrestrial settings (particularly low-earth orbit platforms) and encounter increasingly Earth-independent medical decision-making scenarios and requirements. This need would likely be met through the development of a Clinical Decision Support System (CDSS) that assimilates information from various sources (e.g., vehicle environmental control system, blood pressure cuff, and heart rate monitor) integrated with medical and wellness data to provide detailed guidance tailored to individual crew member needs. This presentation will address some of the fundamental considerations and their implications that must be fully understood by CDSS requirement developers early in the system lifecycle.

B Burian↗

HUMAN FACTORS AND BEHAVIORAL PERFORMANCE EXPLORATION MEASURES: ASSESSING ASTRONAUT RISK

INTRODUCTION: The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures to assess behavioral health and performance risk related to future exploration class missions, and to support reduction of the Human Research Program’s (HRP) Behavioral Medicine (BMed), Team, Sleep, and Human Systems Integration Architecture (HSIA) risks. This presentation will provide an overview of the HFBP-EM program, describe its implementation across spaceflight analogs and the international space station (ISS), and discuss its applicability to audience members. TOPIC: HFBP-EM is a research program designed to develop a standard set of measures that can be used in space and space-analog research to characterize BMed, Team, Sleep, and HSIA risks. It is an ongoing research project that is used examine the validity and reliability of HFBP measures, as well as their shorter forms. It also serves as a test bed for HFBP measures being considered for the spaceflight standard measures. The suite of measures is used to test the efficacy of countermeasures. To date, HFBP-EM has been collected in Human Exploration Research Analogs campaigns 4 and 5, and the SIRIUS 19 mission in the Russian Ground Based Experiment Complex. A subset of the HFBP-EM suite was collected during spaceflight as part of HRP’s Standard Measures in Spaceflight Project. Data was collected from a total of 55 multinational astronaut and astronaut-like crewmembers (mean age: 39.5, SD = 7.6; 31% female; 91% with advanced degrees). Three broad categories of HFBP-EM measures and their relevance to HRP risks will be discussed: 1) surveys that assess team functioning (Teams risk) as well as mood and affect (Bmed risk), 2) performance-based tasks of cognitive functioning and operationally relevant performance (Bmed risk), and 3) physiological biomarkers of sleep (sleep risk) and heart rate (Bmed risk). We will provide an overview of the background of the HFBP-EM program, what the suite currently includes, and next steps in its future development. We will also discuss the application to aerospace practitioners and researchers. APPLICATION: Astronaut teams selected for future space exploration missions will face several challenges that pose significant yet still unknown risks to the behavioral health and performance of astronauts. The HFBP-EM suite provides a comprehensive assessment of behavioral health and performance in space analog and spaceflight settings. This suite can be applied to both operational and research settings to advance risk reduction research for long duration space exploration missions.

S T Bell↗

Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) – Physical Workload Approximation

The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a hybrid reality exploration surface analog, “Assessments of Physiology and Cognition in Hybrid-reality Environments” (APACHE). The goal of APACHE is to create a planetary extravehicular activity (EVA) simulation environment that provides a representative physical and cognitive workload approximation using a combination of virtual reality (VR), physical reality, and hybrid reality (HR) techniques. To develop and characterize the physical workload approximation within the APACHE environment, a two-part approach was implemented. In part 1, baseline physical work load during ambulation within APACHE was evaluated and compared with that in other planetary EVA analog environments and with existing data sets from Apollo planetary EVAs and reduced gravity testing of prototype planetary spacesuits. For this evaluation, 10 subjects were asked to ambulate in three surface analog environments: a passive treadmill in APACHE, natural terrain in an outdoor field environment, and a standard motorized treadmill. Subjects’ heart rate and metabolic rate (VO2/VCO2) were measured and compared among the different test conditions and existing data sets. Gait parameters were also collected to compare with suited mechanics and to understand the role of gait kinematics in physical workload. In part 2, the aim is to evaluate the addition of a custom weighted body suit to the aforementioned surface analog environments and the ability to titrate the suit configuration to provide the best possible physical workload approximation for simulation of lunar and Martian EVAs.

Alex Baughman↗

Validation of Fitness for Duty Standards Using Pre- and Post-Flight Capsule Egress and Suited Functional Performance Tasks in Simulated Reduced Gravity (Pilot Egress Fitness)

As NASA prepares for exploration missions, it will be critical to understand and build upon known crew capabilities. Specifically, we need to know the functional capacities of crew at different stages of a mission and characterize these profiles so that the appropriate vehicle requirements and mission concepts of operations (ConOps) can be developed. One of the most complex phases of any missions is when there is a transition between gravity environments. For instance, both physiological adaptation to microgravity and subsequent re-entry into a gravity environment result in reduced functional capacity, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk tasks may have to be performed soon after gravity transitions: •Unassisted capsule egress task after return to Earth •Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study has been broken down into two phases. A pilot phase to assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing and the full Egress Fitness study, which will be part of the CIPHER complement. This study uses a functional task approach to characterize performance of these high-risk tasks in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and mobility to be able to complete the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth based emergency egress out of a functional capsule mockup, and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing can occur almost anytime pre-flight, but post-flight scheduling is much more critical with the capsule egress test occurring 1-4 hours after landing and the planetary EVA approximately 18-36 hours after landing. Data collected for both tasks includes task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed baseline pre-flight testing on 3 astronaut subjects. Post-flight testing of the first two subjects will be completed in November 2021 and the final subject around March 2022. Results and lessons learned from this pilot study will inform the full Egress Fitness study, which will incorporate additional pre-flight sessions, longer EVA tasks, and post-flight testing on R+1, 4, and 7 to characterize the timeframe of recovery

J R Norcross↗

Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) – Physical Workload Approximation

The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a hybrid reality exploration surface analog, “Assessments of Physiology And Cognition in Hybrid-reality Environments” (APACHE). The goal of APACHE is to create a planetary extravehicular activity (EVA) simulation environment that provides a representative physical and cognitive workload approximation using a combination of virtual reality (VR), physical reality, and hybrid reality (HR) techniques. To develop and characterize the physical workload approximation within the APACHE environment, a two-part approach was implemented. In part 1, baseline physical workload during ambulation within APACHE was evaluated and compared with that in other planetary EVA analog environments and with existing data sets from Apollo planetary EVAs and reduced gravity testing of prototype planetary spacesuits. For this evaluation, 10 subjects were asked to ambulate in three surface analog environments: a passive treadmill in APACHE, natural terrain in an outdoor field environment, and a standard motorized treadmill. Subjects’ heart rate and metabolic rate (VO2/VCO2)were measured and compared among the different test conditions and existing data sets. Gait parameters were also collected to compare with suited mechanics and to understand the role of gait kinematics in physical workload. In part 2, the aim is to evaluate the addition of a custom weighted body suit to the aforementioned surface analog environments and the ability to titrate the suit configuration to provide the best possible physical workload approximation for simulation of lunar and Martian EVAs.

Alexander J Baughman↗