Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

H and K maps of two star-forming regions: S 140 and CEP A OB3

The molecular clouds near S 140 and Cep A OB3 both contain regions that emit strongly in the infrared but which have relatively little or no emission in radio wavelengths. The lack of radio emission is usually interpreted to mean that little ionization has taken place, and that the IR emission comes from dust heated by a central pre-main sequence object. We have made high resolution maps of these two areas with H and K broadband filters with the 2.3m telescope of the Wyoming Infrared Observatory (WIRO). Our observations were made with an InSb detector using the standard WIRO mapping technique of multiple scanning to construct a series of 64x64 pictures. Our scanning was made in one arcsec steps with a 7 inch aperture to produce a resolution of about 6 sec FWHM. Observations of S 140 by Blair et al (1978) with moderate resolution in J, H, and K, revealed a prominent IR source that they called S 140IR. We have scanned an area surrounding their S 140IR region and have obtained total IR fluxes which are in close agreement with Blair et al. Additional detail corresponds to that seen by Dinerstein et al (1979) at 0.9 microns and Campbell (1986) at 1.0 microns. The large (H-K) values for all components of S 140IR indicates that they are probably embedded in the parent molecular cloud with A(v) = 25 mag and A(K) = 2.2 mag. Recent radio studies of Cep A by Hughes and Wouterloot (1984) and FIR studies by Evans et al (1981) have shown the similarity of Cep A to S 140. There is, however, some emission detected from ionized regions by the radio observations, indicating a slightly more advanced stage of evolution for Cep A. We observed an area around the strongest source in Cep A in both H and K, and the K map is presented. We have identified three sources separate from the main source.

Graadalen, G. L.↗

Hyperselective carbon membranes for precise high-temperature H 2 and CO 2 separation

More than 90% of the world’s hydrogen (H 2 ) is produced from fossil fuel sources, which requires energy-intensive separation and purification to produce high-purity H 2 fuel and to capture the carbon dioxide (CO 2 ) by-product. While membranes can decarbonize H 2 /CO 2 separation, their moderate H 2 /CO 2 selectivity requires secondary H 2 purification by pressure swing adsorption. Here, we report hyperselective carbon molecular sieve hollow fiber membranes showing H 2 /CO 2 selectivity exceeding 7000 under mixture permeation at 150°C, which is almost 30 times higher than the most selective nonmetallic membrane reported in the literature. The membrane is able to maintain an ultrahigh H 2 /CO 2 selectivity over 1400 under mixture permeation at 400°C. Pore structure characterization suggests that highly refined ultramicropores are responsible for effectively discriminating the closely sized H 2 and CO 2 molecules in the hyperselective carbon molecular sieve membrane. Modeling shows that the unprecedented H 2 /CO 2 selectivity will potentially allow one-step enrichment of fuel-grade H 2 from shifted syngas for decarbonized H 2 production.

Science & Technology - Other Topics↗

On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds

Purpose: To investigate the feasibility of and challenges yet to be addressed to measure dose from low energy (effective energy <50 keV) brachytherapy sources (Pd-103, Cs-131, and I-125) using polyurethane based 3D dosimeters with optical CT. Methods: The authors' evaluation used the following sources: models 200 (Pd-103), CS-1 Rev2 (Cs-131), and 6711 (I-125). The authors used the Monte Carlo radiation transport code MCNP5, simulations with the ScanSim optical tomography simulation software, and experimental measurements with PRESAGE{sup ®} dosimeters/optical CT to investigate the following: (1) the water equivalency of conventional (density = 1.065 g/cm{sup 3}) and deformable (density = 1.02 g/cm{sup 3}) formulations of polyurethane dosimeters, (2) the scatter conditions necessary to achieve accurate dosimetry for low energy photon seeds, (3) the change in photon energy spectrum within the dosimeter as a function of distance from the source in order to determine potential energy sensitivity effects, (4) the optimal delivered dose to balance optical transmission (per projection) with signal to noise ratio in the reconstructed dose distribution, and (5) the magnitude and characteristics of artifacts due to the presence of a channel in the dosimeter. Monte Carlo simulations were performed using both conventional and deformable dosimeter formulations. For verification, 2.8 Gy at 1 cm was delivered in 92 h using an I-125 source to a PRESAGE{sup ®} dosimeter with conventional formulation and a central channel with 0.0425 cm radius for source placement. The dose distribution was reconstructed with 0.02 and 0.04 cm{sup 3} voxel size using the Duke midsized optical CT scanner (DMOS). Results: While the conventional formulation overattenuates dose from all three sources compared to water, the current deformable formulation has nearly water equivalent attenuation properties for Cs-131 and I-125, while underattenuating for Pd-103. The energy spectrum of each source is relatively stable within the first 5 cm especially for I-125. The inherent assumption of radial symmetry in the TG43 geometry leads to a linear increase in sample points within the 3D dosimeter as a function of distance away from the source, which partially offsets the decreasing signal. Simulations of dose reconstruction using optical CT showed the feasibility of reconstructing dose out to a radius of 10 cm without saturating projection images using an optimal dose and high dynamic range scanning; the simulations also predicted that reconstruction artifacts at the channel surface due to a small discrepancy in refractive index should be negligible. Agreement of the measured with calculated radial dose function for I-125 was within 5% between 0.3 and 2.5 cm from the source, and the median difference of measured from calculated anisotropy function was within 5% between 0.3 and 2.0 cm from the source. Conclusions: 3D dosimetry using polyurethane dosimeters with optical CT looks to be a promising application to verify dosimetric distributions surrounding low energy brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

ON THE UBIQUITY OF MOLECULAR ANIONS IN THE DENSE INTERSTELLAR MEDIUM

Results are presented from a survey for molecular anions in seven nearby Galactic star-forming cores and molecular clouds. The hydrocarbon anion C{sub 6}H{sup -} is detected in all seven target sources, including four sources where no anions have been previously detected: L1172, L1389, L1495B, and TMC-1C. The C{sub 6}H{sup -}/C{sub 6}H column density ratio is {approx}> 1.0% in every source, with a mean value of 3.0% (and standard deviation 0.92%). Combined with previous detections, our results show that anions are ubiquitous in dense clouds wherever C{sub 6}H is present. The C{sub 6}H{sup -}/C{sub 6}H ratio is found to show a positive correlation with molecular hydrogen number density, and with the apparent age of the cloud. We also report the first detection of C{sub 4}H{sup -} in TMC-1 (at 4.8{sigma} confidence), and derive an anion-to-neutral ratio C{sub 4}H{sup -}/C{sub 4}H =(1.2 {+-} 0.4) Multiplication-Sign 10{sup -5}(= 0.0012% {+-} 0.0004%). Such a low value compared with C{sub 6}H{sup -} highlights the need for a revised radiative electron attachment rate for C{sub 4}H. Chemical model calculations show that the observed C{sub 4}H{sup -} could be produced as a result of reactions of oxygen atoms with C{sub 5}H{sup -} and C{sub 6}H{sup -}.

74 ATOMIC AND MOLECULAR PHYSICS↗

A MULTI-COLOR OPTICAL SURVEY OF THE ORION NEBULA CLUSTER. I. THE CATALOG

We present U, B, V, I broadband, 6200 A TiO mediumband, and H{alpha} narrowband photometry of the Orion Nebula Cluster (ONC) obtained with the WFI imager at the ESO/MPI 2.2 telescope at La Silla Observatory. The nearly simultaneous observations cover the entire ONC in a field of about 34 x 34 arcmin. They enable us to determine stellar colors avoiding the additional scatter in the photometry induced by stellar variability typical of pre-main-sequence stars. We identify 2612 point-like sources in the I band; 58%, 43%, and 17% of them are also detected in V, B, and U, respectively. 1040 sources are identified in the H{alpha} band. In this paper we present the observations, the calibration techniques adopted, and the resulting catalog. We show the derived color-magnitude diagram of the population and discuss the completeness of our photometry. We define a spectrophotometric TiO index that takes into account the fluxes in the V, I, and TiO bands. Comparing it with spectral types of ONC members in the literature, we find a correlation between the index and the spectral type valid for M-type stars, which is accurate to better than 1 spectral subclass for M3-M6 types and better than 2 spectral subclasses for M0-M2 types.. This allows us to newly classify 217 stars. In a similar way, we subtract from our H{alpha} photometry the photospheric continuum at its wavelength, deriving calibrated line excess for the full sample. This represents the largest H{alpha} star catalog obtained to date on the ONC. This data set enables a full re-analysis of the properties of the pre-main-sequence population in the Orion Nebula Cluster to be presented in an accompanying paper.

79 ASTRONOMY AND ASTROPHYSICS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS): The AGN catalog and its X-ray spectral properties

The eROSITA Final Equatorial Depth Survey (eFEDS), observed with eROSITA ahead of its planned 4-yr all-sky survey, is the largest contiguous-field X-ray survey at present. It yielded a large sample of X-ray sources with very rich multiband photometric and spectroscopic coverage. We present here the eFEDS active galactic nuclei (AGN) catalog and the eROSITA X-ray spectral properties of the eFEDS sources. Using a Bayesian method, we performed a systematic X-ray spectral analysis for all the eFEDS sources. We adopted multiple spectral models, including single-component power-law or hot-plasma models and double-component models of a power law plus soft excess. We investigated the capacity of eROSITA X-ray spectra for constraining AGN spectral shapes through a detailed analysis of the posterior parameter probability distribution functions. Hierarchical Bayesian modeling was used to recover the spectral parameter distribution of the sample. The source fluxes and luminosities were measured from the posterior of the spectral fitting. The eFEDS AGN catalog (22 079 sources) comprises ~80% of the eFEDS point sources. Despite a large number of faint sources, our spectral fitting provides reasonable measurements of spectral shapes and intrinsic luminosities for a majority of the sources. Because of sample selection bias, this AGN catalog is dominated by X-ray unobscured sources, with an obscured (logN H > 21.5) fraction of 8%; the power-law emission of the hot corona is also relatively soft, with a typical slope of 2.0. For type-I AGN, the X-ray emission is well correlated with the UV emission with the usual anticorrelation between the X-ray to UV spectral slope α OX and the UV luminosity. The X-ray spectral properties measured with various models are presented for all the eFEDS sources.

79 ASTRONOMY AND ASTROPHYSICS↗

The mass-sheet degeneracy and time-delay cosmography: analysis of the strong lens RXJ1131-1231

We present extended modelling of the strong lens system RXJ1131-1231 with archival data in two HST bands in combination with existing line-of-sight contribution and velocity dispersion estimates. Our focus is on source size and its influence on time-delay cosmography. We therefore examine the impact of mass-sheet degeneracy and especially the degeneracy pointed out by Schneider and Sluse (2013) [1] using the source reconstruction scale. We also extend on previous work by further exploring the effects of priors on the kinematics of the lens and the external convergence in the environment of the lensing system. Our results coming from RXJ1131-1231 are given in a simple analytic form so that they can be easily combined with constraints coming from other cosmological probes. We find that the choice of priors on lens model parameters and source size are subdominant for the statistical errors for H {sub 0} measurements of this systems. The choice of prior for the source is sub-dominant at present (2% uncertainty on H {sub 0}) but may be relevant for future studies. More importantly, we find that the priors on the kinematic anisotropy of the lens galaxy have a significant impact on our cosmological inference. When incorporating all the above modeling uncertainties, we find H {sub 0} = 86.6{sup +6.8}{sub -6.9} km s{sup -1} Mpc{sup -1}, when using kinematic priors similar to other studies. When we use a different kinematic prior motivated by Barnabè et al. (2012) [2] but covering the same anisotropic range, we find H {sub 0} = 74.5{sup +8.0}{sub -7.8} km s{sup -1} Mpc{sup -1}. This means that the choice of kinematic modeling and priors have a significant impact on cosmographic inferences. The way forward is either to get better velocity dispersion measures which would down weight the impact of the priors or to construct physically motivated priors for the velocity dispersion model.

79 ASTRONOMY AND ASTROPHYSICS↗

Li{sup +} alumino-silicate ion source development for the neutralized drift compression experiment

We report results on lithium alumino-silicate ion source development in preparation for warm dense matter heating experiments on the new neutralized drift compression experiment II. The practical limit to the current density for a lithium alumino-silicate source is determined by the maximum operating temperature that the ion source can withstand before running into problems of heat transfer, melting of the alumino-silicate material, and emission lifetime. Using small prototype emitters, at a temperature of {approx_equal}1275 deg. C, a space-charge limited Li{sup +} beam current density of J {approx_equal}1 mA/cm{sup 2} was obtained. The lifetime of the ion source was {approx_equal}50 h while pulsing at a rate of 0.033 Hz with a pulse duration of 5-6 {mu}s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Airborne flux measurements of ammonia over the Southern Great Plains using chemical ionization mass spectrometry

Ammonia (NH 3 ) is an abundant trace gas in the atmosphere and an important player in atmospheric chemistry, aerosol formation and the atmosphere-surface exchange of nitrogen. It is recognized as a major source of aerosol pollution, and it may limit the formation of cloud nuclei in remote or cold parts of the atmosphere. For soil and plants, NH 3 -mediated nitrogen can act as a harmful pollutant or as a desirable nutrient, mostly in natural and agricultural settings, respectively. Agriculture is also the main source of atmospheric NH 3 via volatilization from fertilizers and manure processing in livestock farming. The accurate determination of NH 3 emission rates remains a challenge, partly due to the propensity of NH 3 to interact with instrument surfaces leading to high detection limits and slow response times. In this paper, we present a new method for quantifying ambient NH 3 , using chemical ionization mass spectrometry (CIMS) with deuterated benzene cations as reagents. The setup aimed at limiting sample-surface interactions and achieved a 1-σ precision of 10–20 pptv and an immediate 1/e response rate < 0.4 s, which compares favorably to the existing state of the art. The sensitivity exhibited an inverse humidity dependence, in particular in relatively dry conditions. Background of up to 10 % of the total signal required consideration as well, as it responded on the order of a few minutes. To showcase the method’s capabilities, we quantified NH3 mixing ratios from measurements obtained during deployment on a Gulfstream I aircraft during the HI-SCALE (Holistic Interactions of Shallow Clouds, Aerosols and Land Ecosystems) field campaign in rural Oklahoma during May 2016. Typical mixing ratios were 1–10 parts per billion by volume (ppbv) for the boundary layer and 0.1–1 ppbv in the lower free troposphere. Sharp plumes of up to 10s of ppbv of NH3 were encountered as well. We identified two of their sources as a large fertilizer plant and a cattle farm, and our mixing ratio measurements yielded upper bounds of 350 ± 50 and 0.6 kg NH 3 h –1 for their respective momentary source rates. The fast response of the CIMS also allowed us to derive vertical NH 3 fluxes within the turbulent boundary layer via eddy covariance, for which we chiefly used the continuous wavelet transform technique. As expected for a region dominated by agriculture, we observed predominantly upward fluxes, implying net NH 3 emissions from surface. The corresponding analysis focused on the most suitable flight, which contained two straight-and-level legs at ~300 m above ground. We derived NH 3 fluxes between –4 and 18 mol km –2 h –1 for these legs, at an effective spatial resolution of 1–2 km. The analysis demonstrated how flux measurements benefit from suitably arranged flight tracks with sufficiently long straight-and-level legs, and explores the detrimental effect of measurement discontinuities. Following flux footprint estimations, comparison to the NH 3 area emissions inventory provided by the US Environmental Protection Agency indicated overall agreement, but also the absence of some sources, for instance the identified cattle farm. Our study concludes that high-precision CIMS measurements are a powerful tool for in-situ measurements of ambient NH 3 mixing ratios, and even allow for the airborne mapping of the air-surface exchange of NH 3 .

54 ENVIRONMENTAL SCIENCES↗

ALMA IMAGING OF MILLIMETER/SUBMILLIMETER CONTINUUM EMISSION IN ORION KL

We have carried out high-resolution observations with the Atacama Large Millimeter/Submillimeter Array (ALMA) of continuum emission from the Orion Kleinmann–Low (KL) region. We identify 11 compact sources at ALMA band 6 (245 GHz) and band 7 (339 GHz), including the Hot Core, Compact Ridge, SMA1, IRc4, IRc7, and a radio source I (Source I). A spectral energy distribution (SED) of each source is determined by using previous 3 mm continuum emission data. Physical properties such as size, mass, hydrogen number density, and column density are discussed based on the dust graybody SED. Among 11 identified sources, Source I, a massive protostar candidate, is a dominant energy source in Orion KL. We extensively investigate its SED from centimeter to submillimeter wavelengths. The SED of Source I can be fitted with a single power-law index of 1.97, suggesting an optically thick emission. We employ the H{sup −} free–free emission as an opacity source of this optically thick emission. The temperature, density, and mass of the circumstellar disk associated with Source I are constrained by the SED of H{sup −} free–free emission. Still, the fitting result shows a significant deviation from the observed flux densities. Combined with the thermal dust graybody SED to explain excess emission at higher frequency, a smaller power-law index of 1.60 for the H{sup −} free–free emission is obtained in the SED fitting. The power-law index smaller than two would suggest a compact source size or a clumpy structure unresolved with the present study. Future higher resolution observations with ALMA are essential to reveal more detailed spatial structure and physical properties of Source I.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-05: Dosimetric Evaluation and Validation of Newlydeveloped Well Chamber for Use in the Calibration of Brachytherapy Sources

Purpose: To evaluate the dosimetric characteristics of newly developed well type ionization chamber and to validate the results with the commercially available calibrated well chambers that are being used for the calibration of brachytherapy sources. Methods: The newly developed well type ionization chamber (BDS 1000) has been designed for the convenient use in brachytherapy which is open to atmospheric condition. The chamber has a volume of 240 cm3 and weight of 2.5 Kg. The calibration of the radioactive source with activities from 0.01 mCi to 20 Ci can be carried out using this chamber. The dosimetric parameters such as leakage current, stability, scattering effect, ion collection efficiency, reference air kerma rate and nominal response with energy were carried out with the BDS 1000 well type ion chamber. The evaluated dosimetric characteristics of BDS1000 well chamber were validated with two other commercially available well chambers (HDR 1000 plus and BTC/3007). Results: The measured leakage current observed was negligible for the newly developed BDS 1000 well type ion chamber. The ion collection efficiency was close to 1 and the response of the chamber was found to be very stable. The determined sweet spot was at 42 mm from bottom of the chamber insert. The reference air kerma rate was found to be 4.634 × 105 Gym2hr-1A-1 for the BDS 1000 well chamber. The overall dosimetric characteristics of BDS 1000 well chamber was in good agreement with the dosimetric properties of other two well chambers. Conclusion: The dosimetric study shows that the newly developed BDS 1000 well type ionization chamber is high sensitive and reliable chamber for reference air kerma strength calibration. The results obtained confirm that this chamber can be used for the calibration of HDR and LDR brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

A SPITZER VIEW OF STAR FORMATION IN THE CYGNUS X NORTH COMPLEX

We present new images and photometry of the massive star-forming complex Cygnus X obtained with the Infrared Array Camera (IRAC) and the Multiband Imaging Photometer for Spitzer (MIPS) on board the Spitzer Space Telescope. A combination of IRAC, MIPS, UKIRT Deep Infrared Sky Survey, and Two Micron All Sky Survey data are used to identify and classify young stellar objects (YSOs). Of the 8231 sources detected exhibiting infrared excess in Cygnus X North, 670 are classified as class I and 7249 are classified as class II. Using spectra from the FAST Spectrograph at the Fred L. Whipple Observatory and Hectospec on the MMT, we spectrally typed 536 sources in the Cygnus X complex to identify the massive stars. We find that YSOs tend to be grouped in the neighborhoods of massive B stars (spectral types B0 to B9). We present a minimal spanning tree analysis of clusters in two regions in Cygnus X North. The fraction of infrared excess sources that belong to clusters with {>=}10 members is found to be 50%-70%. Most class II objects lie in dense clusters within blown out H II regions, while class I sources tend to reside in more filamentary structures along the bright-rimmed clouds, indicating possible triggered star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

H i 21-cm absorption in radio-loud AGN with double-peaked [O iii ] emission

ABSTRACT Different physical processes in galaxy evolution, such as galaxy mergers that lead to coalescence of dual Active Galactic Nuclei (AGN) and outflows emanating from the narrow line region, can leave their imprint on the optical spectra of AGN in the form of double-peaked narrow emission lines. To investigate the neutral gas in the centres of such AGN, we have conducted a pilot survey of H i 21-cm absorption, using the upgraded Giant Metrewave Radio Telescope (uGMRT), in radio-loud AGN whose optical spectra show double-peaked [O iii] emission lines at z ≤ 0.4 (median z ≈ 0.14). Among the eight sources for which we could obtain clean spectra, we detect H i 21-cm absorption in three sources (detection rate of $38^{+36}_{-20}$ per cent) and find tentative indication of absorption in two other sources. The detection rate of H i 21-cm absorption is tentatively higher for the systems that show signatures of interaction or tidal disturbance (≳ 50 per cent) in the ground-based optical images than that for the systems that appear single and undisturbed (≈25 per cent). This is consistent with the high incidence of H i 21-cm absorption observed in z ≤ 0.2 galaxy mergers. Higher spatial resolution spectroscopy is required to confirm the origin of the H i absorbing gas, i.e. either gas infalling on to the radio-loud AGN, outflowing gas ejected by the AGN, or gas in rotation on the galactic-scale or circumnuclear discs.

79 ASTRONOMY AND ASTROPHYSICS↗

DIFFUSE MOLECULAR CLOUD DENSITIES FROM UV MEASUREMENTS OF CO ABSORPTION

We use UV measurements of interstellar CO toward nearby stars to calculate the density in the diffuse molecular clouds containing the molecules responsible for the observed absorption. Chemical models and recent calculations of the excitation rate coefficients indicate that the regions in which CO is found have hydrogen predominantly in molecular form and that collisional excitation is by collisions with H{sub 2} molecules. We carry out statistical equilibrium calculations using CO-H{sub 2} collision rates to solve for the H{sub 2} density in the observed sources without including effects of radiative trapping. We have assumed kinetic temperatures of 50 K and 100 K, finding this choice to make relatively little difference to the lowest transition. For the sources having T{sup ex}{sub 10} only for which we could determine upper and lower density limits, we find (n(H{sub 2})) = 49 cm{sup -3}. While we can find a consistent density range for a good fraction of the sources having either two or three values of the excitation temperature, there is a suggestion that the higher-J transitions are sampling clouds or regions within diffuse molecular cloud material that have higher densities than the material sampled by the J = 1-0 transition. The assumed kinetic temperature and derived H{sub 2} density are anticorrelated when the J = 2-1 transition data, the J = 3-2 transition data, or both are included. For sources with either two or three values of the excitation temperature, we find average values of the midpoint of the density range that is consistent with all of the observations equal to 68 cm{sup -3} for T{sup k} = 100 K and 92 cm{sup -3} for T{sup k} = 50 K. The data for this set of sources imply that diffuse molecular clouds are characterized by an average thermal pressure between 4600 and 6800 K cm{sup -3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Origin of extracted negative ions by 3D PIC-MCC modeling. Surface vs Volume comparison

The development of a high performance negative ion (NI) source constitutes a crucial step in the construction of Neutral Beam Injector (NBI) of the future fusion reactor ITER. NI source should deliver 40 A of H{sup -}(or D{sup -}), which is a technical and scientific challenge, and requires a deeper understanding of the underlying physics of the source and its magnetic filter. The present knowledge of the ion extraction mechanism from the negative ion source is limited and concerns magnetized plasma sheaths used to avoid electrons being co-extracted from the plasma together with the NI. Moreover, due to the asymmetry induced by the ITER crossed magnetic configuration used to filter the electrons, any realistic study of this problem must consider the three spatial dimensions. To address this problem, a 3D Particles-in-Cell electrostatic collisional code was developed, specifically designed for this system. Binary collisions between the particles are introduced using Monte Carlo Collision scheme. The complex orthogonal magnetic field that is applied to deflect electrons is also taken into account. This code, called ONIX (Orsay Negative Ion eXtraction), was used to investigate the plasma properties and the transport of the charged particles close to a typical extraction aperture [1]. This contribution focuses on the limits for the extracted NI current from both, plasma volume and aperture wall. Results of production, destruction, and transport of H{sup -} in the extraction region are presented. The extraction efficiency of H{sup -} from the volume is compared to the one of H{sup -} coming from the wall.

43 PARTICLE ACCELERATORS↗

TSD Dose and X/Q calculation

The purposes of this study are: Calculate the radiological dose due to a potential accident for the Transportation Safety Document (TSD). The calculation is based on the DOE Tool Box code MACCS2 Version 1.13.1 and FGR-13 dose conversion factor. Calculate the dilution factor X/Q which will be used to determine the consequence of a potential toxic chemical release. The calculation is based on the DOE Tool Box code MACCS2 Version 1.13.1. Calculate the Equivalent Source Term Mass Multiplier (ESTMM) relative to the 30-year aged fuel grade Pu for the 30-year aged weapon grade Pu, natural Uranium, enriched uranium, plutonium isotopes, uranium isotopes, and several other isotopes. The dose and X/Q are calculated based on the following two TSD potential accident scenarios for the release of 1 Ci of Pu-239 and 1 g of fuel grade plutonium: a ground level spill without building wake and a ground level fire with 5 MW sensible heat and with 20'W x 30'H building wake. The Equivalent Source Term Mass Multiplier (ESTMM) is calculated for various isotope materials. The dose and X/Q at 90 m are also calculated by extrapolation which shows that the dose and X/Q calculated by MACCS2 based on a spatial interval (0, 180 m) could be very conservative.

61 RADIATION PROTECTION AND DOSIMETRY↗

PHOTOMETRIC REDSHIFTS IN THE HAWAII-HUBBLE DEEP FIELD-NORTH (H-HDF-N)

We derive photometric redshifts (z {sub phot}) for sources in the entire (∼0.4 deg{sup 2}) Hawaii-Hubble Deep Field-North (H-HDF-N) field with the EAzY code, based on point-spread-function-matched photometry of 15 broad bands from the ultraviolet (U band) to mid-infrared (IRAC 4.5 μm). Our catalog consists of a total of 131,678 sources. We evaluate the z {sub phot} quality by comparing z {sub phot} with spectroscopic redshifts (z {sub spec}) when available, and find a value of normalized median absolute deviation σ{sub NMAD} = 0.029 and an outlier fraction of 5.5% (outliers are defined as sources having |z{sub phot} – z{sub spec} |/(1 + z{sub spec} ) > 0.15) for non-X-ray sources. More specifically, we obtain σ{sub NMAD} = 0.024 with 2.7% outliers for sources brighter than R = 23 mag, σ{sub NMAD} = 0.035 with 7.4% outliers for sources fainter than R = 23 mag, σ{sub NMAD} = 0.026 with 3.9% outliers for sources having z < 1, and σ{sub NMAD} = 0.034 with 9.0% outliers for sources having z > 1. Our z {sub phot} quality shows an overall improvement over an earlier z {sub phot} work that focused only on the central H-HDF-N area. We also classify each object as a star or galaxy through template spectral energy distribution fitting and complementary morphological parameterization, resulting in 4959 stars and 126,719 galaxies. Furthermore, we match our catalog with the 2 Ms Chandra Deep Field-North main X-ray catalog. For the 462 matched non-stellar X-ray sources (281 having z {sub spec}), we improve their z {sub phot} quality by adding three additional active galactic nucleus templates, achieving σ{sub NMAD} = 0.035 and an outlier fraction of 12.5%. We make our catalog publicly available presenting both photometry and z {sub phot}, and provide guidance on how to make use of our catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

A Synthetic Nickel Electrocatalyst With a Turnover Frequency Above 100,000 s-1 for H2 Production

Increased worldwide energy demand will require greater use of carbon-neutral sustainable energy sources. The intermittent nature of solar and wind power requires storage of energy, so electrocatalysts that convert electrical energy to chemical bonds in fuels are needed. Platinum is an excellent catalyst, but it is of low abundance and high cost. Hydrogenase enzymes in Nature catalyze the evolution of H2 and use earth-abundant metals such as nickel and iron. We report that a synthetic nickel catalyst, [Ni(7PPh2NPh)2](BF4)2, (7PPh2NPh = 1,3,6-triphenyl-1-aza-3,6-diphosphacycloheptane) catalyzes the production of H2 using [(DMF)H]+OTf as the proton source, with turnover frequencies of 31,000 s-1 in dry acetonitrile and 108,000 s-1 in the presence of H2O (1.2 M), at a potential of -1.13 V (vs. the ferrocenium/ferrocene couple). These turnover frequencies exceed those reported for the [FeFe] hydrogenase enzyme by more than an order of magnitude, and are the fastest reported for any molecular catalyst for H2 production. This material is based upon work supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science, Office of Basic Energy Sciences.

17 WIND ENERGY↗