Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Isolation and Purification of the Xenon Fraction of 252Cf Spontaneous Fission Products for the Production of Radio Xenon Calibration Standards

The presence of radioactive xenon isotopes indicates that fission events have occurred, and is used to help enforce the Comprehensive Test Ban Treaty. Idaho National Laboratory (INL) produces 135Xe, 133mXe, 133Xe, and 131mXe standards used for the calibration and testing of collection equipment and analytical techniques used to monitor radio xenon emissions. At INL, xenon is produced and collected as one of several spontaneous fission products from a 252Cf source. Further chromatographic purification of the fission gases ensures the separations of the xenon fraction for selective collection. An explanation of the fission gas collection, separation and purification is presented. Additionally, the range of 135Xe to 133Xe ratio that can be isolated is explained. This is an operational update on the work introduced previously, now that it is in operation and has been recharged with a second 252Cf source.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Organic compounds in meteorites. II.

Aromatic compounds in benzene eluate fractions from carbonaceous chondrites by high resolution capillary gas-liquid chromatography

GAS CHROMATOGRAPHY↗

Dicarboxylic acid emissions from a GDI engine equipped with a catalytic gasoline particulate filter

Dicarboxylic acids play an important role in atmospheric chemistry, yet their emissions from primary sources, such as internal combustion engines, has not been extensively studied. In this paper, KOH impregnated quartz filters were loaded with exhaust gases from a gasoline direct injection (GDI) engine equipped with a catalytic gasoline particulate filter (GPF). All filters were analyzed for carboxylic and dicarboxylic acids using a derivatized gas chromatography-mass spectroscopy method. Exhaust gas was sampled from pre-GPF and post-GPF locations to determine the performance of the GPF regarding acid conversion. Lean and stoichiometric engine modes were considered with non-oxygenated gasoline and 10% splash blended ethanol in gasoline (E10) to examine the impact of stoichiometry and fuel type. Acid emissions represented as much as 0.51% of total unburned hydrocarbon emissions for total monocarboxylic acids and as much as 0.40% for total dicarboxylic acids. Individual acid concentrations were as high as 38 mg/kg-fuel for monocarboxylic acids and as high as 29 mg/kg-fuel for dicarboxylic acids. Overall, the study found that fuel oxygenates had mixed impact on the acid emissions. Engine-out monocarboxylic acids were reduced when using the E10 fuel by approximately 30–45% for the stoichiometric condition and increased marginally for the lean condition. Dicarboxylic acid emissions were generally insensitive to ethanol content. However, the engine condition significantly affected the acid emissions. Lean operation produced a factor of two to an order of magnitude higher emissions rates of both monocarboxylic and dicarboxylic acids than the stoichiometric condition. The catalytic GPF eliminated between 80 and 92% of the acids emitted from the engine, allowing some acids to be emitted into the environment.

42 ENGINEERING↗

Endocrine disrupting chemicals in seminal plasma and couple fecundity

Highlights: • Non-persistent endocrine disruptors were detected and quantified in seminal plasma. • Concentrations were lower in seminal plasma than in urine. • Benzophenones were associated with reduced fecundability, but not significantly. • Bi-directional associations for other endocrine disruptors, but not significant. Growing evidence supports the importance of men's exposure to non-persistent endocrine disruptors (EDCs) and couple fecundability, as measured by time-to-pregnancy (TTP). This evolving literature contrasts with the largely equivocal findings reported for women's exposures and fecundity. While most evidence relies upon urinary concentrations, quantification of EDCs in seminal plasma may be more informative about potential toxicity arising within the testes. We analyzed 5 chemical classes of non-persistent EDCs in seminal plasma for 339 male partners of couples who were recruited prior to conception and who were followed daily until pregnant or after one year of trying. Benzophenones, bisphenols, parabens, and phthalate metabolites and phthalate diesters were measured using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) except for phthalate diesters, which were analyzed using gas chromatography-mass spectrometry. Cox regression with discrete-time was used to estimate fecundability odds ratios (FORs) and 95% confidence intervals (CIs) for each chemical to estimate the probability of pregnancy. While most EDCs were detected in seminal plasma, concentrations were lower than urinary concentrations previously analyzed for the cohort. None of the EDCs were significantly associated with fecundability even after covariate adjustment, though benzophenones consistently yielded FORs <1.0 (ranging from 0.72 to 0.91) in couple-adjusted models suggestive of diminished fecundity (longer TTP). The findings underscore that a range of EDCs can be quantified in seminal plasma, but the lower concentrations may require a large cohort for assessing couple fecundability, as well as the need to consider other fecundity outcomes such as semen quality.

54 ENVIRONMENTAL SCIENCES↗

Chemical analysis of outgassing contaminants on spacecraft surfaces

Methods for analyzing and characterizing outgassing contaminants from such materials as RTV 501 potting compound and S 13 G paint are presented. Fractional distillation of a gross distillate from RTV 501 rubber was carried out and the distilled fractions examined as to their ultraviolet and infrared spectra by gas liquid chromatography. A sensitive technique for structural analysis and molecular identification was found to consist of a gas chromatography-mass spectroscopy system, which was determined to be economically unfeasible at present.

Mcnutt, R. C.↗

Screening of ovarian steroidogenic pathway in Ciona intestinalis and its modulation after tributyltin exposure

In this study, we have identified several ovarian steroids in Ciona with high similarity to vertebrate steroids and showed that cholesterol, corticosterone, dehydroepiandrosterone, estrone, estradiol-17beta, testosterone, pregnenolone, progesterone, have identical molecular spectra with vertebrate steroids. In addition, we have studied the effects of an endocrine disruptor (tributyltin: TBT) on these sex hormones and their precursors, ovarian morphology, and gene expression of some key enzymes in steroidogenic pathway in the ovary of Ciona. Ovarian specimens were cultured in vitro using different concentrations of TBT (10{sup -5}, 10{sup -4} and 10{sup -3} M). Ethanol was used as solvent control. Gene expression analysis was performed for adrenodoxin (ADREN) and adrenodoxin reductase (ADOX) (mediators of acute steroidogenesis) and 17beta-hydroxysteroid dehydrogenase (17beta-HSD). These transcripts were detected and measured by quantitative (real-time) polymerase chain reaction (qPCR). Sex steroids and their precursors were identified and quantified by a gas chromatography-mass spectroscopy (GC-MS) method. Exposure of Ciona ovaries to TBT produced modulations (either increased or decreased) of sterols and sex steroid levels, whereas no significant differences in ADREN, ADOX or 17beta-HSD mRNA expression patterns were observed. Histological analysis shows that TBT produced several modifications on Ciona ovarian morphology that includes irregular outline of nuclear membrane, less compacted cytoplasm, in addition to test and granulosa cells that were detached from the oocyte membrane. Given that the ascidians represent very simple experimental models for the study of endocrine disruption by environmental contaminants, our findings provide excellent models for multiple identification and quantification of sex steroid and their precursors in biological samples exposed to endocrine-disrupting chemicals and for direct extrapolation of such effects across taxonomic groups and phyla. In addition, these results suggest that Cionaintestinalis may be a suitable species for molecular ecotoxicological studies and biomarker model for endocrine-disrupting effects in marine invertebrates.

60 APPLIED LIFE SCIENCES↗

Portable chemical detection platform for on-site monitoring of odorant levels in natural gas

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert–butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1–5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.

03 NATURAL GAS↗

Photodegradation of Paracetamol in Nitrate Solution

The photodegradation of paracetamol in nitrate solution under simulated solar irradiation has been investigated. The degradation rates were compared by varying environmental parameters including concentrations of nitrate ion, humic substance and pH values. The quantifications of paracetamol were conducted by HPLC method. The results demonstrate that the photodegradation of paracetamol followed first-order kinetics. The photoproducts and intermediates of paracetamol in the presence of nitrate ions were identified by extensive GC-MS method. The photodegradation pathways involving. OH radicals as reactive species were proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The estimation of N{sub 2}O emissions from municipal solid waste incineration facilities: The Korea case

The greenhouse gases (GHGs) generated in municipal solid waste (MSW) incineration are carbon dioxide (CO{sub 2}), methane (CH{sub 4}), and nitrous oxide (N{sub 2}O). In South Korea case, the total of GHGs from the waste incineration facilities has been increasing at an annual rate 10%. In these view, waste incineration facilities should consider to reduce GHG emissions. This study is designed to estimate the N{sub 2}O emission factors from MSW incineration plants, and calculate the N{sub 2}O emissions based on these factors. The three MSW incinerators examined in this study were either stoker or both stoker and rotary kiln facilities. The N{sub 2}O concentrations from the MSW incinerators were measured using gas chromatography-electron capture detection (GC-ECD) equipment. The average of the N{sub 2}O emission factors for the M01 plant, M02 plant, and M03 plant are 71, 75, and 153 g-N{sub 2}O/ton-waste, respectively. These results showed a significant difference from the default values of the intergovernmental panel on climate change (IPCC), while approaching those values derived in Japan and Germany. Furthermore, comparing the results of this study to the Korea Energy Economics Institute (KEEI) (2007) data on waste incineration, N{sub 2}O emissions from MSW incineration comprised 19% of the total N{sub 2}O emissions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The O{sub 2}-enriched air gasification of coal, plastics and wood in a fluidized bed reactor

Highlights: Black-Right-Pointing-Pointer The effect of the O{sub 2} in the gasification stream of a BFB gasifier has been studied. Black-Right-Pointing-Pointer Main advantage of the O{sub 2}-enriched air is the increasing of the bed temperature. Black-Right-Pointing-Pointer No remarkable effects on tar reduction. Decreasing of recognized PAHs. Black-Right-Pointing-Pointer Gasification reactions completed inside the dense bed and splashing zone. Black-Right-Pointing-Pointer Polycondensation reactions occur mainly in the freeboard region. - Abstract: The effect of oxygen-enriched air during fluidized bed co-gasification of a mixture of coal, plastics and wood has been investigated. The main components of the obtained syngas were measured by means of on-line analyzers and a gas chromatograph while those of the condensate phase were off-line analysed by means of a gas chromatography-mass spectrometer (GC-MS). The characterization of condensate phase as well as that of the water used as scrubbing medium completed the performed diagnostics. The experimental results were further elaborated in order to provide material and substances flow analyses inside the plant boundaries. These analyses allowed to obtain the main substance distribution between solid, gaseous and condensate phases and to estimate the conversion efficiency of carbon and hydrogen but also to easily visualise the waste streams produced by the process. The process performance was then evaluated on the basis of parameters related to the conversion efficiency of fuels into valuable products (i.e. by considering tar and particulate as process losses) as well as those related to the energy recovery.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

60 APPLIED LIFE SCIENCES↗

Calculation of Transactinide Homolog Isotope Production Reactions Possible with the Center for Accelerator Mass Spectrometry (CAMS) at Lawrence Livermore National Laboratory

The LLNL heavy element group has been investigating the chemical properties of the heaviest elements over the past several years. The properties of the transactinides (elements with Z > 103) are often unknown due to their low production rates and short half-lives, which require lengthy cyclotron irradiations in order to make enough atoms for statistically significant evaluations of their chemistry. In addition, automated chemical methods are often required to perform consistent and rapid chemical separations on the order of minutes for the duration of the experiment, which can last from weeks to months. Separation methods can include extraction chromatography, liquid-liquid extraction, or gas-phase chromatography. Before a lengthy transactinide experiment can be performed at an accelerator, a large amount of preparatory work must be done both to ensure the successful application of the chosen chemical system to the transactinide chemistry problem being addressed, and to evaluate the behavior of the lighter elemental homologs in the same chemical system. Since transactinide chemistry is literally performed on one single atom, its chemical properties cannot be determined from bulk chemical matrices, but instead must be inferred from the behavior of the lighter elements that occur in its chemical group and in those of its neighboring elements. By first studying the lighter group homologs in a particular chemical system, when the same system is applied to the transactinide element under investigation, its decay properties can be directly compared to those of the homologues, thereby allowing an inference of its own chemistry. The Center for Accelerator Mass Spectrometry (CAMS) at Lawrence Livermore National Laboratory (LLNL) includes a 1 MV Tandem accelerator, capable of accelerating light ions such as protons to energies of roughly 15 MeV. By using the CAMS beamline, tracers of transactinide homolog elements can be produced both for development of chemical systems and for evaluation of homolog chemical properties. CAMS also offers an environment for testing these systems 'online' by incorporating automated chemical systems into the beamline so that tracers can be created, transported, and chemically separated all on the shorter timescales required for transactinide experiments. Even though CAMS is limited in the types and energies of ions they can accelerate, there are still a wide variety of reactions that can be performed there with commercially available target materials. The half-lives of these isotopes vary over a range that could be used for both online chemistry (where shorter half-lives are required) and benchtop tracers studies (where longer lived isotopes are preferred). In this document, they present a summary of tracer production reactions that could be performed at CAMS, specifically for online, automated chemical studies. They are from chemical groups four through seven, 13, and 14, which would be appropriate for studies of elements 104-107, 113, and 114. Reactions were selected that had (a) commercially available target material, (b) half-lives long enough for transport from a target chamber to an automated chemistry system, and (c) cross-sections at CAMS available projectile energies that were large enough to produce enough atoms to result in a statistically relevant signal after losses for transport and chemistry were considered. In addition, the resulting product atoms had to decay with an observable gamma-ray using standard Ge gamma-ray detectors. The table includes calculations performed for both metal targets and their corresponding oxides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement in multiphase reacting flows

A survey is presented of diagnostic techniques and measurements made in multiphase reacting flows. The special problems encountered by the presence of liquid droplets, soot and solid particles in high temperature chemically reacting turbulent environments are outlined. The principal measurement techniques that have been tested in spray flames are spark photography, laser anemometry, thermocouples and suction probes. Spark photography provides measurement of drop size, drop size distribution, drop velocity, and angle of flight. Photographs are analysed automatically by image analysers. Photographic techniques are reliable, inexpensive and proved. Laser anemometers have been developed for simultaneous measurement of velocity and size of individual particles in sprays under conditions of vaporization and combustion. Particle/gas velocity differentials, particle Reynolds numbers, local drag coefficients and direct measurement of vaporization rates can be made by laser anemometry. Gas temperature in sprays is determined by direct in situ measurement of time constants immediately prior to measurement with compensation and signal analysis by micro-processors. Gas concentration is measured by suction probes and gas phase chromatography. Measurements of particle size, particle velocity, gas temperature, and gas concentration made in airblast and pressure atomised liquid spray flames are presented.

Chigier, N. A.↗

Detection of Agar, by Analysis of Sugar Markers, Associated with Bacillus Anthracis Spores, After Culture

Detection of small quantities of agar associated with spores of Bacillus anthracis could provide key information regarding its source or growth characteristics. Agar, widely used in growth of bacteria on solid surfaces, consists primarily of repeating polysaccharide units of 3,6-anhydro-L-galactose (AGal) and galactose (Gal) with sulfated and O-methylated galactoses present as minor constituents. Two variants of the alditol acetate procedure were evaluated for detection of potential agar markers associated with spores. The first method employed a reductive hydrolysis step, to stabilize labile anhydrogalactose, by converting to anhydrogalactitol. The second eliminated the reductive hydrolysis step simplifying the procedure. Anhydrogalactitol, derived from agar, was detected using both derivatization methods followed by gas chromatography-mass spectrometry (GC-MS) analysis. However, challenges with artefactual background (reductive hydrolysis) or marker destruction (hydrolysis) lead to the search for alternative sugar markers. A minor agar component, 6-O-methyl galactose (6-O-M gal), was readily detected in agar-grown but not broth-grown bacteria. Detection was optimized by the use of gas chromatography-tandem mass spectrometry (GC-MS-MS). With appropriate choice of sugar marker and analytical procedure, detection of sugar markers for agar has considerable potential in microbial forensics.

59 BASIC BIOLOGICAL SCIENCES↗