Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Development of BPM Electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗

Development of BPM electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability - is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗

Optimizing collimator positions using bayesian optimization in the Fermilab MI-8 transfer line

Collimators are used to minimize losses and to remove particles that would otherwise get lost downstream and irradiate the machine. Finding the optimal jaw positions is time consuming and with the upstream beam properties changing, the collimation settings would need to be readjusted each time. Therefore, a method to optimize collimator positions and to operate them at full capacity in a short time is required for loss control downstream. A study of collimator positions was conducted and a machine learning (ML) model was developed to predict optimal collimator positions. Bayesian Optimization (BO) was used to calculate new jaw positions from the ML model. The results of BO and usage of ML for better performance of the collimation system are presented in this paper.

Babacan, Betiay [Fermilab]↗

Design and testing of the New Muon Lab cryogenic system at Fermilab

Fermi National Accelerator Laboratory is constructing a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab building. The facility will be used for testing and validating cryomodule designs as well as support systems. For the initial phase of the project, a single Type III plus 1.3 GHz cryomodule will be cooled and tested using a single Tevatron style standalone refrigerator. Subsequent phases involve testing as many as two full RF units consisting of up to six 1.3 GHz cryomodules with the addition of a new cryogenic plant. The cryogenic infrastructure consists of the refrigerator system, cryogenic distribution system as well as an ambient temperature pumping system to achieve 2 K operations with supporting purification systems. A discussion of the available capacity for the various phases versus the proposed heat loads is included as well as commissioning results and testing schedule. This paper describes the plans, status and challenges of this initial phase of the New Muon Lab cryogenic system.

43 PARTICLE ACCELERATORS↗

Study of thermosiphon cooling scheme for the production solenoid of the Mu2e experiment at Fermilab

A thermosiphon cooling scheme is envisioned for the Production Solenoid of the Mu2e experiment at Fermi National Accelerator Laboratory. The thermosiphon cooling is achieved by indirect cooling with helium at 4.7 K. The siphon tubes are welded to the solenoid outer structure. The anticipated heat loads in the solenoid is presented as well as the cooling scheme design. A thermal model using ANSYS to simulate the temperature gradient is presented. The thermal analysis also makes provisions for including the heat load generated in the coils and structures by the secondary radiation simulated using the MARS 15 code. The impact of the heat loads from supports on the solenoid cooling is studied. The thermosiphon cooling scheme is also validated using pertinent correlations to study flow reversals and the cooling regime.

43 PARTICLE ACCELERATORS↗

Diffractive W and Z Production at the Fermilab Tevatron

We report on a measurement of the fraction of events with a W or Z boson produced diffractively in {bar p}p collisions at {radical}s = 1.96 TeV, using data from 0.6 fb{sup -1} of integrated luminosity collected with the CDF II detector equipped with a Roman-pot spectrometer that detects the {bar p} from {bar p} + p {yields} {bar p}+[X+W/Z]. We find that (0.97 {+-} 0.11)% of Ws and (0.85 {+-} 0.22)% of Zs are produced diffractively in a region of (anti)proton fractional momentum loss {zeta} of 0.03 < {zeta} < 0.10 and 4-momentum transferred squared t of -1 < t < 0 (GeV/c){sup 2}. We also report on searches for W and Z production in double Pomeron exchange, p+{bar p} {yields} p+[X+W/z]+{bar p}, and on exclusive Z production, {bar p}p {yields} {bar p}+Z+p. No signal is seen above background for these processes, and comparisons are made with expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transverse Instabilities in the Fermilab Recycler

Transverse instabilities of the antiproton beam have been observed in the Recycler ring soon after its commissioning. After installation of transverse dampers, the threshold for the instability limit increased significantly but the instability is still found to limit the brightness of the antiprotons extracted from the Recycler for Tevatron shots. In this paper, we describe observations of the instabilities during the extraction process as well as during dedicated studies. The measured instability threshold phase density agrees with the prediction of the rigid beam model within a factor of 2. Also, we conclude that the instability threshold can be significantly lowered for a bunch contained in a narrow and shallow potential well due to effective exclusion of the longitudinal tails from Landau damping.

43 PARTICLE ACCELERATORS↗

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Shielding experiments by the JASMIN collaboration at Fermilab (II) - Radioactivity measurement induced by secondary particles from the anti-proton production target

The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10{sub 12} protons per second. Samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.

43 PARTICLE ACCELERATORS↗

Fermilab SRF cryomodule operational experience

Fermi National Accelerator Laboratory is constructing an Advanced Accelerator Research and Development facility at New Muon Lab. The cryogenic infrastructure in support of the initial phase of the facility consists of two Tevatron style standalone refrigerators, cryogenic distribution system as well as an ambient temperature pumping system to achieve 2K operations with supporting purification systems. During this phase of the project a single Type III plus 1.3 GHz cryomodule was installed, cooled and tested. Design constraints of the cryomodule required that the cryomodule individual circuits be cooled at predetermined rates. These constraints required special design solutions to achieve. This paper describes the initial cooldown and operational experience of a 1.3 GHz cryomodule using the New Muon Lab cryogenic system.

43 PARTICLE ACCELERATORS↗

VetTech Program at Fermilab

Are you a veteran with technical or computing skills? Do you want to pursue a career at the leading edge of technology and innovation? Then we want to hear from you.

Fermilab, Fermilab↗

Artificial Intelligence Research at Fermilab

The unique challenges of high-energy physics research present opportunities for advancing AI technologies. From the principles of fundamental physics underlying massive and rich data sets to building and operating some of the world’s most complex detector and accelerator systems, the technologies we are developing have potential connections to a broad domain of cutting-edge AI research.

Fermilab, Fermilab↗

ArgoNeuT and MicroBooNE: LAr-TPC's at Fermilab

Liquid Argon Time Projection Chamber technology provides unique features in event imaging and calorimetric resolution. These characteristics, combined with a good rejection power and a (virtually) unlimited active mass, make this detector one of the best candidate for the next generation of long-baseline neutrino oscillation experiments aimed at precision measurements of the MNPS matrix elements. Up to now the largest LAr-TPC operated is the first semi-module of the ICARUS T600 detector (300 tons of LAr). The scalability of this technology to massive detectors (>=5 ktons) is still to be proven. The ArgoNeuT detector, a small LAr-TPC (0.24 ton of active mass) exposed to the NuMI beam at FNAL currently producing the first low-energy neutrino events in a LAr-TPC, is the first step of a staged US program to realize and operate a massive LAr-TPC detector. The proposed MicroBooNE experiment, a LAr-TPC of 100 tons of active mass, to be exposed to the Booster Neutrino Beam and the NuMI beam at FNAL, is the next crucial step of this program. Design details and experimental goals of both experiments are reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab courts Latin American physicists

The lab wants to build on existing connections with Mexico and Central and South America as it begins to build a flagship neutrino lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument Front-Ends at Fermilab During Run II

The optimization of an accelerator relies on the ability to monitor the behavior of the beam in an intelligent and timely fashion. The use of processor-driven front-ends allowed for the deployment of smart systems in the field for improved data collection and analysis during Run II. This paper describes the implementation of the two main systems used: National Instruments LabVIEW running on PCs, and WindRiver's VxWorks real-time operating system running in a VME crate processor.

43 PARTICLE ACCELERATORS↗

Search for new physics in the {mu}{mu}+e/{mu}+Ee{sub T} channel with a low-p{sub T} lepton threshold at the Collider Detector at Fermilab

A search for new physics using three-lepton (trilepton) data collected with the CDF II detector and corresponding to an integrated luminosity of 976 pb{sup -1} is presented. The standard model predicts a low rate of trilepton events, which makes some supersymmetric processes, such as chargino-neutralino production, measurable in this channel. The {mu}{mu}+l signature is investigated, where l is an electron or a muon, with the additional requirement of large missing transverse energy. In this analysis, the lepton transverse momenta with respect to the beam direction (p{sub T}) are as low as 5 GeV/c, a selection that improves the sensitivity to particles that are light as well as to ones that result in leptonically decaying tau leptons. At the same time, this low-p{sub T} selection presents additional challenges due to the non-negligible heavy-quark background at low lepton momenta. This background is measured with an innovative technique using experimental data. Several dimuon and trilepton control regions are investigated, and good agreement between experimental results and standard-model predictions is observed. In the signal region, we observe one three-muon event and expect 0.4{+-}0.1 {mu}{mu}+l events from standard-model processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗