Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Smart Grid Integrity Attacks: Characterizations and Countermeasures

Real power injections at loads and generators, and real power flows on selected lines in a transmission network are monitored, transmitted over a SCADA network to the system operator, and used in state estimation algorithms to make dispatch, re-balance and other energy management system [EMS] decisions. Coordinated cyber attacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm. These unobservable attacks present a serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unobservable attacks [under standard DC load flow approximations] involving the compromise of exactly two power injection meters and an arbitrary number of power meters on lines is presented. This requires O(n2m) flops for a power system with n buses and m line meters. If all lines are metered, there exist canonical forms that characterize all 3, 4, and 5-sparse unobservable attacks. These can be quickly detected in power systems using standard graph algorithms. Known secure phase measurement units [PMUs] can be used as countermeasures against an arbitrary collection of cyber attacks. Finding the minimum number of necessary PMUs is NP-hard. It is shown that p + 1 PMUs at carefully chosen buses are sufficient to neutralize a collection of p cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel consumption for various driving styles in conventional and hybrid electric vehicles: Integrating driving cycle predictions with fuel consumption optimization

Here, improving fuel economy and lowering emissions are key societal goals. Standard driving cycles, pre-designed by the US Environmental Protection Agency (EPA), have long been used to estimate vehicle fuel economy in laboratory-controlled conditions. They have also been used to test and tune different energy management strategies for hybrid electric vehicles (HEVs). This paper aims to estimate fuel consumption for a conventional vehicle and a HEV using personalized driving cycles extracted from real-world data to study the effects of different driving styles and vehicle types on fuel consumption when compared to the estimates based on standard driving cycles. To do this, we extracted driving cycles for conventional vehicles and HEVs from a large-scale U.S. survey that contains real-world GPS-based driving records. Next, the driving cycles were assigned to one of three categories: volatile, normal, or calm. Then, the driving cycles were used along with a driver-vehicle simulation that captures driver decisions (vehicle speed during a trip), powertrain, and vehicle dynamics to estimate fuel consumption for conventional vehicles and HEVs with power-split powertrain. To further optimize fuel consumption for HEVs, the Equivalent Consumption Minimization Strategy (ECMS) is applied. The results show that depending on the driving style and the driving scenario, conventional vehicle fuel consumption can vary widely compared with standard EPA driving cycles. Specifically, conventional vehicle fuel consumption was 13% lower in calm urban driving, but almost 34% higher for volatile highway driving compared with standard EPA driving cycles. Interestingly, when a driving cycle is predicted based on the application of case-based reasoning and used to tune the power distribution in a hybrid electric vehicle, its fuel consumption can be reduced by up to 12% in urban driving. Implications and limitations of the findings are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Novel Application of Parallel Betweenness Centrality to Power Grid Contingency Analysis

In Energy Management Systems, contingency analysis is commonly performed for identifying and mitigating potentially harmful power grid component failures. The exponentially increasing combinatorial number of failure modes imposes a significant computational burden for massive contingency analysis. It is critical to select a limited set of high-impact contingency cases within the constraint of computing power and time requirements to make it possible for real-time power system vulnerability assessment. In this paper, we present a novel application of parallel betweenness centrality to power grid contingency selection. We cross-validate the proposed method using the model and data of the western US power grid, and implement it on a Cray XMT system - a massively multithreaded architecture - leveraging its advantages for parallel execution of irregular algorithms, such as graph analysis. We achieve a speedup of 55 times (on 64 processors) compared against the single-processor version of the same code running on the Cray XMT. We also compare an OpenMP-based version of the same code running on an HP Superdome shared-memory machine. The performance of the Cray XMT code shows better scalability and resource utilization, and shorter execution time for large-scale power grids. This proposed approach has been evaluated in PNNL’s Electricity Infrastructure Operations Center (EIOC). It is expected to provide a quick and efficient solution to massive contingency selection problems to help power grid operators to identify and mitigate potential widespread cascading power grid failures in real time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Federal Water Management Planning Manual

This Federal Water Management Resource Guide provides direction to Federal agencies on how optimize water use at Federal facilities, use water balance analysis methods, identify design elements and procurement best practices, and expand use of alternative water. It provides best practices for managing water to be considered when developing or improving an effective facility water management program. PNNL developed this guide for the Federal Energy Management Program (FEMP). FEMP was directed by the Council on Environmental Quality (CEQ) to develop a Federal Water Management Resource Guide per the Implementing Instructions for Executive Order (E.O.) 13834, Efficient Federal Operations. This document serves to satisfy this requirement in order to provide best water management practices within the Federal Government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Water Management Planning Manual

This Federal Water Management Resource Guide provides direction to Federal agencies on how optimize water use at Federal facilities, use water balance analysis methods, identify design elements and procurement best practices, and expand use of alternative water. It provides best practices for managing water to be considered when developing or improving an effective facility water management program. PNNL developed this guide for the Federal Energy Management Program (FEMP). FEMP was directed by the Council on Environmental Quality (CEQ) to develop a Federal Water Management Resource Guide per the Implementing Instructions for Executive Order (E.O.) 13834, Efficient Federal Operations. This document serves to satisfy this requirement in order to provide best water management practices within the Federal Government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Masters Study in Advanced Energy and Fuels Management

There are currently three key drivers for the US energy sector a) increasing energy demand and b) environmental stewardship in energy production for sustainability and c) general public and governmental desire for domestic resources. These drivers are also true for energy nation globally. As a result, this sector is rapidly diversifying to alternate sources that would supplement or replace fossil fuels. These changes have created a need for a highly trained workforce with a the understanding of both conventional and emerging energy resources and technology to lead and facilitate the reinvention of the US energy production, rational deployment of alternate energy technologies based on scientific and business criteria while invigorating the overall economy. In addition, the current trends focus on the the need of Science, Technology, Engineering and Math (STEM) graduate education to move beyond academia and be more responsive to the workforce needs of businesses and the industry. The SIUC PSM in Advanced Energy and Fuels Management (AEFM) program was developed in response to the industries stated need for employees who combine technical competencies and workforce skills similar to all PSM degree programs. The SIUC AEFM program was designed to provide the STEM graduates with advanced technical training in energy resources and technology while simultaneously equipping them with the business management skills required by professional employers in the energy sector. Technical training include core skills in energy resources, technology and management for both conventional and emerging energy technologies. Business skills training include financial, personnel and project management. A capstone internship is also built into the program to train students such that they are acclimatized to the real world scenarios in research laboratories, in energy companies and in government agencies. The current curriculum in the SIUC AEFM will help fill the need for training both recent graduates seeking specialized training prior to entering the energy industry workforce as well as working professionals in the energy industry who require additional training and qualifications for further career advancement. It is expected that the students graduating from the program will be stewards of effective, sustainable and environmentally sound use of these resources to ensure energy independence and meet the growing demands.The application of this Professional Science Masters’ (PSM) program is in the fast evolving Fuels Arena. The PSM AEFM is intended to be a terminal degree which will prepare the graduates for interdisciplinary careers in team-oriented environment. The curriculum for this program was developed in concert with industry to dovetail with current and future demands based on analysis and needs. The primary objective of the project was to exploit the in house resources such as existing curriculum and faculty strengths and develop a curriculum with consultations with industry to meet current and future demands. Additional objectives was to develop courses specific to the degree and to provide the students with a set of business skills in finance accounting and sustainable project management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) [Book]

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diversecase studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Feasibility Study and Resulting Plan for the Bay Mills Indian Community

In 2011 the Inter-Tribal Council of Michigan, Inc. was awarded an Energy Efficiency Development and Deployment in Indian Country grant from the U.S. Department of Energy’s Tribal Energy Program. This grant aimed to study select Bay Mills Indian Community community/government buildings to determine what is required to reduce each building’s energy consumption by 30%. The Bay Mills Indian Community (BMIC) buildings with the largest expected energy use were selected for this study and included the Bay Mills Ellen Marshall Health Center building, Bay Mills Indian Community Administration Building, Bay Mills Community College main campus, Bay Mills Charter School and the Waishkey Community Center buildings. These five sites are the largest energy consuming Community buildings and comprised the study area of this project titled “Energy Efficiency Feasibility Study and Resulting Plan for the Bay Mills Indian Community”. The end objective of this study, plan and the Tribe is to reduce the energy consumption at the Community’s most energy intensive buildings that will, in turn, reduce emissions at the source of energy production, reduce energy expenditures, create long lasting energy conscious practices and positively affect the quality of the natural environment. This project’s feasibility study and resulting plan is intended to act as a guide to the Community’s first step towards planned energy management within its buildings/facilities. It aims to reduce energy consumption by 30% or greater within the subject facilities with an emphasis on energy conservation and efficiency. The energy audits and related power consumption analyses conducted for this study revealed numerous significant energy conservation and efficiency opportunities for all of the subject sites/buildings. In addition, many of the energy conservation measures require no cost and serve to help balance other measures requiring capital investment. Reoccurring deficiencies relating to heating, cooling, thermostat setting inefficiencies, powering computers, lighting, items linked to weatherization and numerous other items were encountered that can be mitigated with the energy conservation measures developed and specified during the course of this project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Auditor and Quality Control Inspector Competency Model

The Energy Auditor (EA) and Quality Control Inspector (QCI) Competency model was developed to identify the soft skills, foundational competencies and define the levels of Knowledge, Skills, and Abilities (KSAs) required to successfully perform the tasks defined in the EA and QCI Job Task Analysis (JTAs), the U.S. Department of Energy (DOE) used the U.S. Department of Labor's (DOL) Competency Model Clearinghouse resources to develop a QCI and EA Competency Model. To keep the QCI and EA competency model consistent with other construction and energy management competency models, DOE and the National Renewable Energy Laboratory used the existing 'Residential Construction Competency Model' and the 'Advanced Commercial Building Competency Model' where appropriate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstration of Vaisala Prototype Differential Absorption Lidar (DIAL) Field Campaign Report

Continuous water vapor profiling within the atmospheric boundary layer is a major unmet measurement requirement for improving weather analysis and prediction. Humidity profile information can be used in mesoscale numerical models for severe weather prediction, flash flood prediction, energy management, and other applications. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility has conducted several experiments at its Southern Great Plains (SGP) observatory in North Central Oklahoma to test and develop techniques for tropospheric water vapor measurements (Turner et al. 2016). This campaign concentrated on a new compact water vapor DIAL (DIfferential Absorption Lidar) instrument that the instrument manufacturer Vaisala has recently developed using a ceilometer-type telescope design (Dabberdt 2016, Roininen,2017). The DIAL system uses eye-safe class 1M semiconductor laser sources in the sub-micron wavelength range. The instrument reports water vapor mixing ratio profiles up to 3000 m within the atmospheric boundary layer, or up to the cloud base, whichever is lower. The purpose of the campaign was to test the Vaisala DIAL prototype (Figure 1) in high-humidity convective conditions at the ARM SGP site, comparing measurements against other instrumentation at the site (Münkel and Roininen 2017). Comparisons were made against Raman lidar and RS92 radiosonde observations of water vapor mixing ratio profiles. The same DIAL prototype has previously been tested in campaigns in Central and Northern Europe (Roininen et al. 2016). The ARM campaign was a collaboration between Vaisala and researchers from Pacific Northwest National Laboratory (PNNL), National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL), and National Aeronautics and Space Administration (NASA) Jet Propulsion Laboratory (JPL). The DIAL was located next to the Raman lidar at the ARM SGP site (Figure 2). Two Vaisala employees visited the site for the installation work, which was carried out on May 15, 2017.

Southern Great Plains, Raman lidar, planetary boun↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Distributed Energy Resource Risk Manager

Organizations need a comprehensive approach to managing security and privacy risks, especially for energy resources that are becoming increasingly distributed. A tool by the National Renewable Energy Laboratory (NREL) makes it possible to manage these risks and maintain the highest standards of cybersecurity. To simplify risk management for facilities and distributed energy resources, NREL has created the Distributed Energy Resource Risk Manager, an automated, user-friendly tool that helps navigate and implement one of the most widely trusted frameworks for information security, the National Institute of Standards and Technology Risk Management Framework.

compliance↗

Guide to Minimizing Compressor-based Cooling in Data Centers

This best practice guide is one in a series created by the Lawrence Berkeley National Laboratory for the Federal Energy Management Program (FEMP), a program of the U.S. Department of Energy. Geared towards architects, engineers, and data center Information Technology (IT) and facility managers, this guide provides information about technologies and practices to use in designing, constructing, and operating sustainable high-performance data centers.

Guide, Minimizing, Compressor-based, Cooling, Data↗

An Efficient Distributed Reinforcement Learning for Enhanced Multi-Microgrid Management

Economic dispatch in multi-microgrid (MMG) systems requires coordinating distributed energy resources (DERs) of different microgrids, which leads to a significant increase in the number of states for energy management. In these cases, traditional reinforcement learning (RL) approaches become computationally expensive or output a solution that causes extra-operating costs for the system. This paper proposes an RL approach that employs local learning agents to interact with microgrid environments in a distributed manner and aggregates the outcomes to train the global agent to learn the policy for the MMG system. This distributed exploration and aggregation process provides an effective solution and guides the global agent to learn the dispatch policy efficiently. Case studies are performed on a system with three microgrids with different types of DERs. Results obtained using the proposed RL and comparisons with conventional methods substantiate the effectiveness of the proposed approach in terms of operation costs, computation time, and peak-to-average ratio.

Das, Avijit↗

Applying Value at Risk Analysis towards Energy Efficiency Investments

Value at Risk (VaR) is a measure of risk for potential losses within a portfolio of investments. Investments in energy efficiency in a manufacturing environment compete in terms of payback period, ease of investment, and transaction costs with other investments (production, safety, engineering, etc.). Because manufacturers have limited amounts of capital to allocate, investments in productivity tend to be prioritized over energy efficiency projects that offer similar paybacks. Value at Risk (VaR) can be used to quantify how risk-weighted expenditures change over time. Energy efficiency investments are often believed to offer relatively stable payoffs compared to changes in production and other assets, particularly when evaluated using methodologies such as simple payback. Incorporating methodologies such as VaR can provide a stronger business case for energy efficiency investments by quantifying value beyond what is captured in other Return on Investment calculations.In this paper we outline a methodology for applying VaR in the context of the variety of investments made by manufacturing organizations. Additionally, we profile the stability of energy efficiency (EE) and renewable energy (RE) investments compared to other types of investments made in manufacturing. By applying VaR to these investments, energy managers can better translate the financial benefits of energy-related capital projects in a way that is more compelling to Corporate Finance and Treasury departments. This common language also allows Corporate Finance and Treasury departments to support large, strategic deployments of capital for such projects based on a targeted objective – the management of financial risk for the organization’s shareholders.

Levine, Eli↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗