Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Ethyl 3-ethoxybutyrate, a new component of the transportation renewable fuel portfolio

The vast majority of energy that powers our global economy is from combustion of fossil fuels with the unintended consequence of increased deposition of carbon dioxide in the atmosphere and oceans. The scientific and technical challenges for the energy sector are to develop renewable energy sources that are sufficient to meet human energy consumption, are economically viable, and are ecologically sustainable. We investigated ethyl 3-ethoxybutyrate (EEB) as a fuel oxygenate in ultra low sulfur diesel (ULSD) with a bench-scale research engine and determined its economic potential as a renewable fuel with technoeconomic modeling using wastewater treatment plant biosolids as the feedstock for poly-3-hydroxyalkanoates (PHB), a bacterial storage polymer from which EEB can be synthesized. EEB blended well with ULSD, and cetane values of 10% and 20% v/v EEB-ULSD blends exceeded 40. A diesel internal combustion engine fueled with 5%, 10%, and 20% EEB-ULSD blends met or exceeded all tested transportation diesel fuel emissions criteria. Inedible organic feedstocks may be used to produce PHB; and thus, EEB might contribute to carbon reductions without compromising performance or air pollutant emissions. However, further research is needed to determine its role in the overall fuel portfolio. (C) 2015 Elsevier Ltd. All rights reserved.

09 BIOMASS FUELS↗

Magnetic effects in sulfur-decorated graphene

The interaction between two different materials can present novel phenomena that are quite different from the physical properties observed when each material stands alone. Strong electronic correlations, such as magnetism and superconductivity, can be produced as the result of enhanced Coulomb interactions between electrons. Two-dimensional materials are powerful candidates to search for the novel phenomena because of the easiness of arranging them and modifying their properties accordingly. In this work, we report magnetic effects in graphene, a prototypical non-magnetic two-dimensional semi-metal, in the proximity with sulfur, a diamagnetic insulator. In contrast to the well-defined metallic behaviour of clean graphene, an energy gap develops at the Fermi energy for the graphene/sulfur compound with decreasing temperature. This is accompanied by a steep increase of the resistance, a sign change of the slope in the magneto-resistance between high and low fields, and magnetic hysteresis. A possible origin of the observed electronic and magnetic responses is discussed in terms of the onset of low-temperature magnetic ordering. These results provide intriguing insights on the search for novel quantum phases in graphene-based compounds.

Science & Technology - Other Topics↗

Trends in U.S. Venture Capital Investments Related to Energy: 1980 through the Third Quarter of 2010

This report documents trends in U.S. venture capital investments over the period 1980 through the third quarter of calendar year 2010 (2010 Q1+Q2+Q3). Particular attention is given to U.S. venture capital investments in the energy/industrial sector over the period 1980-2010 Q1+Q2+Q3 as well as in the more recently created cross-cutting category of CleanTech over the period 1995-2010 Q1+Q2+Q3. During the early 1980s, U.S. venture capital investments in the energy/industrial sector accounted for more than 20% of all venture capital investments. However subsequent periods of low energy prices, the deregulation of large aspects of the energy industry, and the emergence of fast growing new industries like computers (both hardware and software), biotechnology and the Internet quickly reduced the priority accorded to energy/industrial investments. To wit, venture capital investments related to the energy/industrial sector accounted for only 1% of the $132 billion (in real 2010 US$) invested in 2000 by the U.S. venture capital community. The significant increase in the real price of oil that began in 2003-2004 correlates with renewed interest and increased investment by the venture capital community in energy/industrial investment opportunities. Venture capital investments for 2009 for the energy/industrial sector accounted for $2.4 billion or slightly more than 13% of all venture capital invested that year. The total venture capital invested in energy/industrial during the first three quarters of 2010 is close to $2.4 billion accounting for slightly less than 15% of all venture capital investments during the first three quarters of 2010. In 2009, the aggregate amount invested in CleanTech was $2.1 billion (11% of the total US venture capital invested in that lean year) and for the first three quarters of 2010 US venture capital investments in CleanTech have already exceeded $2.8 billion (18% of all US venture capital investments made during the first three quarters of 2010). Between 2004 and 2009, U.S. venture capital investments in energy/industrial as well as CleanTech have more than quadrupled in real terms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guam Strategic Energy Plan

Describes various energy strategies available to Guam to meet the territory's goal of diversifying fuel sources and reducing fossil energy consumption 20% by 2020. The information presented in this strategic energy plan will be used by the Guam Energy Task Force to develop an energy action plan. Available energy strategies include policy changes, education and outreach, reducing energy consumption at federal facilities, and expanding the use of a range of energy technologies, including buildings energy efficiency and conservation, renewable electricity production, and alternative transportation. The strategies are categorized based on the time required to implement them.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commonwealth of the Northern Mariana Islands Strategic Energy Plan

Describes various energy strategies available to CNMI to meet the territory's goal of diversifying fuel sources and reducing fossil energy consumption. The information presented in this strategic energy plan will be used by the CNMI Governor's Energy Task Force to develop an energy action plan. Available energy strategies include policy changes, education and outreach, and expanding the use of a range of energy technologies, including renewable electricity production and buildings energy efficiency and conservation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building Energy Codes Program: National Benefits Assessment (1992-2040)

Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, assuring reductions in energy use and greenhouse gas emissions over the life of buildings. DOE, through the Building Energy Codes Program, supports the improvement of energy efficiency in buildings. BECP periodically assesses the impacts of its activities by estimating historical and projected energy savings, consumer savings, and avoided emissions. The Pacific Northwest National Laboratory conducted the codes benefits assessment in support of the BECP. Underlying the assessment is a series of calculations that estimate and compare energy savings under two scenarios: "with BECP" and "without BECP." The analysis covers the years 1992-2040 and includes comparing the nominal energy savings (assuming 100 percent adoption and compliance) attributable to different code versions, determining the applicable floor space (both residential and commercial) subject to the code, and estimating the final energy savings by adjusting nominal energy savings for the applicable floor space according to the estimated actual adoption and compliance levels. The resulting estimates of energy consumption for each scenario are compared, and the difference equals the impact of BECP activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends in U.S. Venture Capital Investments Related to Energy: 1980-2007

This report documents trends in U.S. venture capital investments over the period 1980-2008. Particular attention is given to U.S. venture capital investments for “internet-specific”, biotechnology, and energy / industrial sectors over the period 1980-2007. During the early 1980s, U.S. venture capital investments in the energy / industrial area accounted for more than 20% of all venture capital investments. However subsequent periods of low energy prices and the emergence of fast growing new industries like computers (both hardware and software), biotechnology and the Internet quickly reduced the priority accorded to energy / industrial investments as by 2000 these investments accounted for only 1% of the $119 billion dollars invested that year by the U.S. venture capital community. The significant increase in the real price of oil that began in 2003-2004 correlates with renewed interest and increased investment by the venture capital community in energy / industrial investment opportunities. Venture capital investments in 2007 for the energy / industrial sector accounted for $3 billion or slightly more than 10% of all venture capital invested that year.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SUBTASK 6.1 – STRATEGIC STUDIES

The Energy & Environmental Research Center (EERC) has recently completed 7 years of research through the Cooperative Agreement with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) focused on fossil energy technology development and demonstration. To support a significant number of the different activities being considered within all of our research contracts with NETL, a subtask (6.1 – Strategic Studies) was created to focus on small research efforts that came up throughout the year that would support an existing EERC–NETL project or would help to develop a new concept for inclusion in future efforts. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26- 08NT43291

01 COAL, LIGNITE, AND PEAT↗

Energy Systems Integration Partnerships: NREL + Panasonic

In collaboration with Panasonic Enterprise Solutions Company, Xcel Energy, land developer L.C. Fulenwider, and the City and County of Denver, NREL is developing a zero-energy transit-oriented campus at the Denver International Airport's Pena Station.

30 DIRECT ENERGY CONVERSION↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Development of a Trip Energy Estimation Model Using Real-World Global Positioning System Driving Data: Preprint

A data-driven technique for estimation of energy requirements for a proposed vehicle trip has been developed. Based on over 700,000 miles of driving data, the technique has been applied to generate a model that estimates trip energy requirements. The model uses a novel binning approach to categorize driving by road type, traffic conditions, and driving profile. The trip-level energy estimations can easily be aggregated to any higher-level transportation system network desired. The model has been tested and validated on the Austin, Texas, data set used to build this model. Ground-truth energy consumption for the data set was obtained from Future Automotive Systems Technology Simulator (FASTSim) vehicle simulation results. The energy estimation model has demonstrated 12.1 percent normalized total absolute error. The energy estimation from the model can be used to inform control strategies in routing tools, such as change in departure time, alternate routing, and alternate destinations, to reduce energy consumption. The model can also be used to determine more accurate energy consumption of regional or national transportation networks if trip origin and destinations are known. Additionally, this method allows the estimation tool to be tuned to a specific driver or vehicle type.

33 ADVANCED PROPULSION SYSTEMS↗

Wireless Sensor Network for Advanced Energy Management Solutions

Eaton has developed an advanced energy management solution that has been deployed to several Industries of the Future (IoF) sites. This demonstrated energy savings and reduced unscheduled downtime through an improved means for performing predictive diagnostics and energy efficiency estimation. Eaton has developed a suite of online, continuous, and inferential algorithms that utilize motor current signature analysis (MCSA) and motor power signature analysis (MPSA) techniques to detect and predict the health condition and energy usage condition of motors and their connect loads. Eaton has also developed a hardware and software platform that provided a means to develop and test these advanced algorithms in the field. Results from lab validation and field trials have demonstrated that the developed advanced algorithms are able to detect motor and load inefficiency and performance degradation. Eaton investigated the performance of Wireless Sensor Networks (WSN) within various industrial facilities to understand concerns about topology and environmental conditions that have precluded broad adoption by the industry to date. A Wireless Link Assessment System (WLAS), was used to validate wireless performance under a variety of conditions. Results demonstrated that wireless networks can provide adequate performance in most facilities when properly specified and deployed. Customers from various IoF expressed interest in applying wireless more broadly for selected applications, but continue to prefer utilizing existing, wired field bus networks for most sensor based applications that will tie into their existing Computerized Motor Maintenance Systems (CMMS). As a result, wireless technology was de-emphasized within the project, and a greater focus placed on energy efficiency/predictive diagnostics. Commercially available wireless networks were only utilized in field test sites to facilitate collection of motor wellness information, and no wireless sensor network products were developed under this project. As an outgrowth of this program, Eaton developed a patented energy-optimizing drive control technology that is complementary to a traditional variable frequency drives (VFD) to enable significant energy savings for motors with variable torque applications, such as fans, pumps, and compressors. This technology provides an estimated energy saving of 2%-10% depending on the loading condition, in addition to the savings obtained from a traditional VFD. The combination of a VFD with the enhanced energy-optimizing controls will provide significant energy savings (10% to 70% depending on the load and duty cycle) for motors that are presently connected with across the line starters. It will also provide a more favorable return on investment (ROI), thus encouraging industries to adopt VFDs for more motors within their facilities. The patented technology is based on nonintrusive algorithms that estimate the instantaneous operating efficiency and motor speed and provide active energy-optimizing control of a motor, using only existing voltage and current sensors. This technology is currently being commercialized by Eaton’s Industrial Controls Division in their next generation motor control products. Due to the common nonintrusive and inferential nature of various algorithms, this same product can also include motor and equipment condition monitoring features, providing the facility owner additional information to improve process uptime and the associated energy savings. Calculations estimated potential energy savings of 261,397GWh/Yr ($15.7B/yr), through retrofitting energy-optimizing VFDs into existing facilities, and incorporating the solution into building equipment sold by original equipment manufacturers (OEMs) and installed by mechanical and electrical contractors. Utilizing MCSA and MPSA for predictive maintenance (PM) of motors and connected equipment reduces process downtime cost and the cost of wasted energy associated with shutting down and restarting the processes. Estimated savings vary depending on the industry segment and equipment criticality per facility/process. Average downtime for an industrial facility is 4-12 hours with a cost/hr of $7500/hr, with large, critical processes reaching $50-100k/hr. Specific downtime costs are not included in this report because of customer confidentiality, but projected savings across the Industries of the Future (IoF) are still expected to be comparable to the original program estimates. Two generations of customer field deployments and evaluation have been completed during the course of this project. Results from these customer sites have been used for identifying the scope and improving the developed energy and wellness algorithms. The field deployments have confirmed that the hardware for sensing and sampling motor currents and voltages are reliable and able to provide an adequate signal-to-noise ratio from the electrical noise present on the motor signals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Key insights from US Department of Energy Better Plants workforce development bootcamps (2022–2025)

This study examines the effectiveness of the US Department of Energy’s Better Plants Program Bootcamps, which are designed to enhance participants’ technical skills in improving energy efficiency and optimizing operations in manufacturing facilities. Through the analysis of survey data collected from 529 participants across 9 bootcamps, the research investigates the motivations, benefits, and demographic trends of attendees. The findings reveal that skill acquisition and improvement are primary drivers for participation, with key benefits including hands-on training on diagnostic equipment and software tools, networking opportunities, and access to technical resources. The analysis shows strong participation from sectors characterized by high energy consumption and employment, such as chemical and transportation equipment manufacturing. Over 50% of participants have job titles that include “EHS” or “Energy” showing their key roles in leading energy efficiency and energy management efforts in manufacturing. Furthermore, the analysis highlights the distribution of participants across managerial, engineering, and technical roles, revealing a higher representation of managers and engineers. This observation suggests a need for targeted outreach to engage technicians, equipment operators, maintenance staff, and floor workers to ensure comprehensive workforce development. The post-bootcamp survey showed that the participants highly valued the opportunities for peer learning and idea exchange, and the benefits they gained from them. This research contributes to the advancement of manufacturing education by demonstrating the efficacy of specialized training in addressing critical industry challenges and fostering a more competent and empowered workforce.

Energy efficiency↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗