Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A robust and well shielded thermal conductivity device for low temperature measurements

We present a compact mechanically robust thermal conductivity measurement apparatus for measurements at low temperatures (<1 K) and high magnetic fields on small high-purity single crystal samples. A high-conductivity copper box is used to enclose the sample and all the components. The box provides protection for the thermometers, heater, and most importantly the sample increasing the portability of the mount. In addition to physical protection, the copper box is also effective at shielding radio frequency electromagnetic interference and thermal radiation, which is essential for low temperature measurements. A printed circuit board in conjunction with a braided ribbon cable is used to organize the delicate wiring and provide mechanical robustness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive wireless pressure sensor for harsh environments

Methods and apparatuses for measuring static and dynamic pressures in harsh environments are disclosed. A pressure sensor according to one embodiment of the present invention may include a diaphragm constructed from materials designed to operate in harsh environments. A waveguide may be operably connected to the diaphragm, and an electromagnetic wave producing and receiving (e.g., sensing) device may be attached to the waveguide, opposite the diaphragm. A handle may be connected between the diaphragm and the waveguide to provide both structural support and electrical functionality for the sensor. A gap may be included between the handle and the diaphragm, allowing the diaphragm to move freely. An antenna and a ground plane may be formed on the diaphragm or the handle. Electromagnetic waves may be reflected off the antenna and detected to directly measure static and dynamic pressures applied to the diaphragm.

42 ENGINEERING↗

Efficiency evaluation of ground-penetrating radar by the results of measurement of dielectric properties of soils

The work considers the depth evaluation of ground penetrating radar (GPR) surveys using the attenuation factor of electromagnetic radiation in a medium. A method of determining the attenuation factor of low-conductive non-magnetic soils is developed based on the results of direct measurements of permittivity and conductivity of soils in the range of typical frequencies of GPR. The method relies on measuring the shift and width of the resonance line after a soil sample is being placed into a tunable cavity resonator. The advantage of this method is the preservation of soil structure during the measurement.

36 MATERIALS SCIENCE↗

Determination of the in-flight spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

AVIRIS is a science research imaging spectrometer that measures radiance in 224 channels between 400 to 2450 nm in the electromagnetic spectrum. To determine the inflight spectral and radiometric characteristics of AVIRIS a validation and calibration experiment was performed. Five data sets were acquired over a calibration site on the homogeneous playa of Rogers Dry Lake, California, U.S. Surface reflectance, atmospheric optical depths, and atmospheric water vapor measurements were acquired concurrently with the overflights. These in situ measurements were used to constrain the LOWTRAN 7 radiative transfer code to predict the total spectral radiance incident at the AVIRIS aperture. These predicted radiances and the AVIRIS measured radiances were analyzed to validate the inflight characteristics. Inflight spectral channel positions and response functions over the AVIRIS spectral range were derived. Radiometric calibration coefficients were calculated for each channel as well as radiometric accuracy, intraflight stability, and noise equivalent delta radiance.

Green, Robert O.↗

Methods for multisource data analysis in remote sensing

Methods for classifying remotely sensed data from multiple data sources are considered. Special interest is in general methods for multisource classification and three such approaches are considered: Dempster-Shafer theory; fuzzy set theory; and statistical multisource analysis. To apply statistical multisource analysis successfully it is necessary to characterize the reliability of each data source. Separability measures and classification accuracy are used to measure the reliability. These reliability measures are then associated with reliability factors included in the statistical multisource analysis to multispectral scanner data where different segments of the electromagnetic spectrum are treated as different sources. A discussion is included concerning future directions for investigating reliability measures.

Benediktsson, Jon Atli↗

Microwave remote sensing: Active and passive. Volume 1 - Microwave remote sensing fundamentals and radiometry

The three components of microwave remote sensing (sensor-scene interaction, sensor design, and measurement techniques), and the applications to geoscience are examined. The history of active and passive microwave sensing is reviewed, along with fundamental principles of electromagnetic wave propagation, antennas, and microwave interaction with atmospheric constituents. Radiometric concepts are reviewed, particularly for measurement problems for atmospheric and terrestrial sources of natural radiation. Particular attention is given to the emission by atmospheric gases, clouds, and rain as described by the radiative transfer function. Finally, the operation and performance characteristics of radiometer receivers are discussed, particularly for measurement precision, calibration techniques, and imaging considerations.

Ulaby, F. T.↗

Electromagnetic Levitation: A Useful Tool in Microgravity Research

Electromagnetic levitation is one area of the electromagnetic processing of materials that has uses for both fundamental research and practical applications. This technique was successfully used on the Space Shuttle Columbia during the Spacelab IML-2 mission in July 1994 as a platform for accurately measuring the surface tensions of liquid metals and alloys. In this article, we discuss the key transport phenomena associated with electromagnetic levitation, the fundamental relationships associated with thermophysical property measurement that can be made using this technique, reasons for working in microgravity, and some of the results obtained from the microgravity experiments.

Szekely, Julian↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand’s Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the fundamental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scattering provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon's internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (GMn) to unprecedented Q2 using Durand's method, also known as the "ratio" method. Systematic errors are greatly reduced by ext

Datta, Provakar↗

Measurement of energy distribution in flowing hydrogen microwave plasmas

An electrothermal propulsion concept utilizing a microwave plasma system as the mechanism to convert electromagnetic energy into kinetic energy of a flowing gas is investigated. A calorimetry system enclosing a microwave plasma system has been developed to accurately measure the energy inputs and outputs of the microwave plasma system. The rate of energy transferred to the gas can be determined to within + or - 1.8 W from an energy balance around the microwave plasma system. The percentage of the power absorbed by the microwave plasma system transferred to the hydrogen gas as it flows through the system is found to increase with the increasing flow rate, to decrease with the increasing pressure, and to be independent of the absorbed power. An upper bound for the hydrogen gas temperature is estimated from the energy content, heat capacity, and flow rate of the gas stream. A lower bound for an overall heat-transfer coefficient is then calculated, characterizing the energy loss from the hydrogen gas stream to the air cooling of the plasma discharge tube wall. The heat-transfer coefficient is found to increase with the increasing flow rate and pressure and to be independent of the absorbed power. This result indicates that a convective-type mechanism is responsible for the energy transfer.

Chapman, R.↗

Measurement of the π 0 → e + e - γ Dalitz decay at the Mainz Microtron

The Dalitz decay π 0 → e + e - γ has been measured in the γp → π 0 p reaction with the A2 tagged-photon facility at the Mainz Microtron, MAMI. The value obtained for the slope parameter of the π 0 electromagnetic transition form factor, a π = 0.030 ± 0.010 tot , is in agreement with existing measurements of this decay and with recent theoretical calculations. The uncertainty obtained in the value of a π is lower than in previous results based on the π 0 → e + e - γ decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved optical standing-wave beam splitters for dilute Bose–Einstein condensates

Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. Here, in simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Wide-Field Imaging Using Nitrogen Vacancies

Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

Englund, Dirk Robert↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗

The NASA High Intensity Radiated Fields Laboratory

High Intensity Radiated Fields (HIRF) are the result of a multitude of intentional and nonintentional electromagnetic sources that currently exists in the world. Many of today's digital systems are susceptible to electronic upset if subjected to certain electromagnetic environments (EME). Modern aerospace designers and manufacturers increasingly rely on sophisticated digital electronic systems to provide critical flight control in both military, commercial, and general aviation aircraft. In an effort to understand and emulate the undesired environment that high energy RF provides modern electronics, the Electromagnetics Research Branch (ERB) of the Flight Electronics and Technology Division (FETD) conducts research on RF and microwave measurement methods related to the understanding of HIRF. In the High Intensity Radiated Fields Laboratory, the effects of high energy radiating electromagnetic fields on avionics and electronic systems are tested and studied.

Williams, Reuben A.↗

Multimessenger constraints on the neutron-star equation of state and the Hubble constant

Observations of neutron-star mergers with distinct messengers, including gravitational waves and electromagnetic signals, can be used to study the behavior of matter denser than an atomic nucleus and to measure the expansion rate of the Universe as quantified by the Hubble constant. We performed a joint analysis of the gravitational-wave event GW170817 with its electromagnetic counterparts AT2017gfo and GRB170817A, and the gravitational-wave event GW190425, both originating from neutron-star mergers. We combined these with previous measurements of pulsars using x-ray and radio observations, and nuclear-theory computations using chiral effective field theory, to constrain the neutron-star equation of state. We found that the radius of a 1.4–solar mass neutron star is 11.75 − 0.81 + 0.86 km at 90% confidence and the Hubble constant is 66.2 − 4.2 + 4.4 at 1σ uncertainty.

Dietrich, Tim↗

Measurement of the Isolated Nuclear Two-Photon Decay in Ge 72

The nuclear two-photon or double-gamma (2 γ ) decay is a second-order electromagnetic process whereby a nucleus in an excited state emits two gamma rays simultaneously. To be able to directly measure the 2⁢ γ decay rate in the low-energy regime below the electron-positron pair-creation threshold, we combined the isochronous mode of a storage ring with Schottky resonant cavities. The newly developed technique can be applied to isomers with excitation energies down to ~100 keV and half-lives as short as ~10 ms. The half-life for the 2⁢ γ decay of the first-excited 0 + state in bare 72 Ge ions was determined to be 23.9(6) ms, which strongly deviates from expectations.

59 ≤ A ≤ 89↗

Instabilities of low frequency, parallel propagating electromagnetic waves in the earth's foreshock region

An instability analysis is presented for parallel and antiparallel propagating electromagnetic waves generated by reflected and diffuse suprathermal ions upstream of the earth's bow shock. Calculations are performed on the basis of upstream particle observations made by the ISEE 1 Quadrispheric Lepedea instrument and low-energy electron measurements made by the ISEE 1 electron spectrometer for a single period. The electromagnetic dispersion relation is computed and the unstable modes and growth times of the fastest growing waves are determined. It is found that the reflected ions destabilize the plasma most strongly at a wave frequency 0.1 that of the ion gyrofrequency by a resonant ion beam instability for waves propagating upstream and by a nonresonant firehose-like instability for waves propagating downstream. The diffuse ions also destabilize the plasma most strongly at the same frequency by means of resonant instabilities of both right- and left-hand polarized waves propagating away from the bow shock.

Sentman, D. D.↗

The gravity and shape of the moon

This review discusses the current knowledge of the gravity and geometry of the moon, and their implications as to lunar structure. Measurements pertaining to the gravity field are, first and foremost, Doppler tracking of spacecraft that have orbited the moon, but also the laser ranging from the earth to the moon and the gravity meters and accelerometers landed with the Apollo spacecraft. Measurements pertaining to the geometry include (1) those related to the shape: the metric photography and laser altimeters on Apollo 15, 16, and 17; the electromagnetic sounder on Apollo 17; the landmark tracking from earlier Apollo orbiters; and occupations, plus (2) measurements related to the orientation: the laser ranging and interferometry from the earth. The review does not cover determinations of topography from photography taken for geologic or landing reconnaissance purposes. The discussion of tectonic implications is limited to inferences of a quantitative nature. The emphasis is on work since 1970; see Kaula [1969, 1971] for reviews of earlier work.

William M. Kaula↗