Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

High Resolution Far-Infrared Spectra of Thiophosgene with a Synchrotron Source: The nu{sub 2} and nu{sub 4} Bands Near 500 cm{sup -1}

Thiophosgene (Cl{sub 2}CS) is a favorite model system for studies of vibrational dynamics. But there are no previous rotationally-resolved infrared studies because the spectra are very congested due to its (relatively) large mass and multiple isotopic species. Here we report a detailed gas-phase study of the nu{sub 2} (approx504 cm{sup -1}) and nu{sub 4} (approx471 cm{sup -1}) fundamental bands, based on spectra obtained at the Canadian Light Source far-infrared beamline using synchrotron radiation and a Bruker IFS125 FT spectrometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of the thickness of electron beams on the gyrotron efficiency

In this paper the effect of the spread in the radii of electron guiding centers on the gyrotron efficiency is studied. First, the analytical theory is developed for describing this effect in gyrotrons operating in regimes of soft and hard self-excitations. Then, study of this effect in a 670 GHz gyrotron is carried out both analytically and numerically with the use of the available nonstationary self-consistent code. Comparison of results demonstrates very reasonable agreement between numerical data and analytical predictions. It was found that in the case of beam injection at the inner peak of the function describing the beam coupling to the wave the spread in electron guiding center radii can be significantly larger than is usually allowed. This fact greatly alleviates the design of electron guns for terahertz-range gyrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact tomography camera system using a multianode photomultiplier tube for compact torus experiments

A compact tomography camera system consisting of a photomultiplier tube, a multislit optical system, and a band-pass interference filter has been developed. The viewing area and spatial resolution can be configured by the arrangement of the slit system. The camera system has been specially designed for self-organized compact torus experiments having strong magnetohydrodynamics events with a submicrosecond time-scale. The developed system has been tested on a field-reversed configuration formed by the field-reversed theta-pinch. Performance evaluation of the system has been performed by comparison to the former optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Nonintercepting Beam-Size Monitoring with Optical Diffraction Radiation

The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as nonintercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.

43 PARTICLE ACCELERATORS↗

Heavy Mesons Decays in the Light-Front

The light-front approach is applied to calculate electromagnetic form factors of pseudoscalar mesons (ie., pion, kaon and D mesons) and semileptonic transition form factors of the heavy ones. The results are compared with the new experimental data from CLEO and lattice calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Effect On Gas Electron Multiplier Detector Performance

Gas Electron Multiplier (GEM) detector is a gas device with high gain and high efficiency. These detectors use chemically perforated 65 {mu}m thick copper clad Kapton polyimide foils. Given its potential for detecting X-rays and other radiations, GEM detectors may be used in an environment with high radioactivity. The Kapton foils manufacturer, Du Pont Inc., claims that the foils are radioactive resistant. To verify whether the GEM detector performance is affected by the exposure to radiation, several GEM foils were irradiated to a {sup 60}Co source at the gamma-ray irradiation facility at Sterigenics, Tustin, CA. Four sets of GEM foils were exposed to the level of 10 kGy, 100 kGy, 1,000 kGy and 10,000 kGy. The output signal from the GEM detectors with irradiated GEM foils were measured and compared to the detector with no irradiation. We observed that the shapes of the peaks from 5.9 KeV {sup 55}Fe X-ray were distorted and that the detector gain increased compared to that of the un-irradiated detector. In particular, the detector with 10,000 kGy irradiation appeared to have the biggest peak distortion and increased gain. It was also found from that additional electrons from radiation-induced free radicals in the Kapton film contribute to output signal of the irradiated GEM detectors. Further studies are needed to explain the mechanism of these detector performance changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission-electron diffraction by MeV electron pulses

We have developed a compact ultrafast electron diffractometer, consisting of a laser-driven rf photocathode that generates 3.0 MeV probe electron pulses, three-stage lens optics, and a custom-built detector for relativistic electrons. High-quality single-shot transmission electron diffraction has been detected from 180-nm-thick Si single crystals, with an excellent special resolution for diffracted beams; the spot width of 0.02 A{sup -1} is obtained. The pulse width is estimated to be 100 fs in duration. Characteristics of the electron beam and other diffractometer features are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Particle transport and stochastic acceleration in the giant lobes of Centaurus A

The conditions within the giant lobes of Centaurus A are reviewed in light of recent radio and {gamma}-ray observations. Data from WMAP and ground-based telescopes in conjunction with measurements from Fermi-LAT constrain the characteristic field strength and the maximum electron energy. The implications for the transport of energetic particles are discussed in terms of residence times and cooling times within the lobes. Acceleration of electrons and UHECR via the second order Fermi mechanism is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New determination of the N-{Delta}(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies revisited

We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-Delta form factor. We find an increase of 20%{approx}30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C{sub 5}{sup A} are computed. Our new results turn out to be compatible within about 1{sigma} with the former ones. We also stress the existing tension between the recent experimental determination of the {sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0}) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

Microcavity array IR photodetector

An original microcavity array IR photodetector is proposed and the sensitivity and response time of its pixels are calculated. A photosensitive element represents a composite silicon microcavity made of two optically coupled closed waveguides on a dielectric substrate whose resonance wave depends on its temperature. This dependence is used to detect IR radiation which heats an absorbing element and the composite microcavity thermally coupled with this element. It is shown that for a spatial resolution of 45 {mu}m, the time response is 30 ms and the sensitivity is 10{sup -3} K at the IR radiation power of {approx} 4.7 x 10{sup -8} W element{sup -1}. (photodetectors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic imaging of a target directly irradiated in experiments on the Iskra-5 iodine laser facility

We set forth the data of experiments involving direct microtarget irradiation by the 12 second-harmonic beams ({lambda} = 0.66 {mu}m) of iodine laser radiation carried out on the Iskra-5 facility. For microtargets we employed glass shells {approx}500 {mu}m in diameter with {approx}1-{mu}m thick walls, which were filled with a DT mixture at a pressure p{sub DT} {approx} 3-4 atm. In one of these experiments, a tomographic image of the microtarget was recorded from the images obtained using pinhole cameras, which were arranged along seven different directions. The pinhole images were acquired in the X-ray radiation with photon energies above 1.5 keV. The procedure used for reconstructing the volume luminosity of the microtarget is described. An analysis of the tomographic image suggests that the compressed microtarget domain possesses a complex asymmetric shape; 20-30 {mu}m sized structural elements being clearly visible. The resultant data set allowed us to estimate the initial nonuniformity of microtarget surface irradiation by the laser radiation. The rms nonuniformity of microtarget irradiance was estimated at {approx}60 %. (interaction of laser radiation with targets)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation conditions for a picosecond laser with an aberration thermal lens under longitudinal pulsed diode pumping

The dependence of the repetition frequency range that provides stable operation of a picosecond laser with longitudinal pulsed diode pumping on the parameters of the laser cavity and the thermal lens induced in the active element is analysed. The results of calculating the radius of the lower cavity mode as a function of pump beam average power and diameter are reported. Based on the measurements by the probe-beam method, the adequacy of the presented model of aberration thermal lens is demonstrated for the cases of uniformly doped Nd:YAG and composite YAG/Nd:YAG active elements upon tuning the pump pulse repetition frequency within the range of 0 - 1 kHz. The ways for implementing stable generation of millijoule pulses in a specified repetition frequency range are discussed. (control of laser radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IS THE BLACK HOLE IN GX 339-4 REALLY SPINNING RAPIDLY?

The wide-band Suzaku spectra of the black hole (BH) binary GX 339-4, acquired in 2007 February during the Very High state, were reanalyzed. Effects of event pileup (significant within approx3' of the image center) and telemetry saturation of the X-ray Imaging Spectrometer (XIS) data were carefully considered. The source was detected up to approx300 keV, with an unabsorbed 0.5-200 keV luminosity of 3.8 x 10{sup 38} erg s{sup -1} at 8 kpc. The spectrum can be approximated by a power law of photon index 2.7, with a mild soft excess and a hard X-ray hump. When using the XIS data outside 2' of the image center, the Fe K line appeared extremely broad, suggesting a high BH spin as already reported by Miller et al. based on the same Suzaku data and other CCD data. When the XIS data accumulation is further limited to >3' to avoid event pileup, the Fe K profile becomes narrower, and a marginally better solution appears which suggests that the inner disk radius is 5-14 times the gravitational radius (1sigma), though a maximally spinning BH is still allowed by the data at the 90% confidence level. Consistently, the optically thick accretion disk is inferred to be truncated at a radius 5-32 times the gravitational radius. Thus, the Suzaku data allow an alternative explanation without invoking a rapidly spinning BH. This inference is further supported by the disk radius measured previously in the High/Soft state.

79 ASTRONOMY AND ASTROPHYSICS↗

THE COMPLETE SPECTRUM OF THE NEUTRON STAR X-RAY BINARY 4U 0614+091

We observed the neutron star (NS) ultra-compact X-ray binary 4U 0614+091 quasi-simultaneously in the radio band (Very Large Array), mid-infrared (IR)/IR (Spitzer/Multiband Imaging Photometer for Spitzer and Infrared Array Camera), near-IR/optical (Small and Moderate Aperture Research Telescope System), optical-UV (Swift/UV-Optical Telescope), soft and hard X-rays (Swift/X-ray Telescope and Rossi-X-ray Timing Explorer). The source was steadily in its 'hard state'. We detected the source in the whole range, for the first time in the radio band at 4.86 and 8.46 GHz and in the mid-IR at 24 {mu}m, up to 100 keV. The optically thick synchrotron spectrum of the jet is consistent with being flat from the radio to the mid-IR band. The flat jet spectrum breaks in the range {approx}(1-4) x 10{sup 13} Hz to an optically thin power-law synchrotron spectrum with spectral index {approx}-0.5. These observations allow us to estimate a lower limit on the jet radiative power of {approx}3 x 10{sup 32} erg s{sup -1} and a total jet power L{sub J} {approx} 10{sup 34}mu{sup -1}{sub 0.05} E {sup 0.53}{sub c} erg s{sup -1} (where E{sub c} is the high-energy cutoff of the synchrotron spectrum in eV and mu{sub 0.05} is the radiative efficiency in units of 0.05). The contemporaneous detection of the optically thin part of the compact jet and the X-ray tail above 30 keV allows us to assess the contribution of the jet to the hard X-ray tail by synchrotron self-Compton (SSC) processes. We conclude that, for realistic jet size, boosting, viewing angle, and energy partition, the SSC emission alone, from the post-shock, accelerated, non-thermal population in the jet, is not a viable mechanism to explain the observed hard X-ray tail of the NS 4U 0614+091.

79 ASTRONOMY AND ASTROPHYSICS↗

RHESSI TESTS OF QUASI-THERMAL GAMMA-RAY BURST SPECTRAL MODELS

Prompt gamma-ray burst (GRB) spectra evolve on short timescales, suggesting that time-resolved spectral fits may help diagnose the still unknown prompt emission mechanism. We use broadband gamma-ray data from the Ramaty High-Energy Solar Spectroscopic Imager spacecraft to test quasi-thermal models with high signal-to-noise time-resolved spectra of nine bright GRBs. In contrast to results reported in more narrow energy bands, the quality of the fits of quasi-thermal models is poor in relation to fits of the phenomenological Band function. Moreover, the best-fit parameters for the simplest quasi-thermal model, a blackbody plus a nonthermal power law, show significant dependence on the fit band. Models that replace the power law with more complicated nonthermal functions are not robust for the data considered here and decrease the physical relevance of the fit blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GROWTH OF MASSIVE BLACK HOLES AT THEIR LATE STAGE

It is believed that the growth of local massive black holes was dominated by accretion during quasar phases, while a fraction of the local black hole mass was accumulated through accreting gases at very low rates. We derive the black hole mass density as a function of redshift with the bolometric luminosity function of active galactic nuclei (AGNs) assuming that massive black holes grew via accreting the circumnuclear gases, in which the derived black hole mass density is required to match the measured local black hole mass density at z = 0. Advection-dominated accretion flows (ADAFs) are supposed to be present in low-luminosity AGNs/normal galaxies, which are very hot and radiate mostly in the hard X-ray band. Most of the X-ray background (XRB) is contributed by bright AGNs, and a variety of AGN population synthesis models were developed to model the observed XRB in the last two decades. Based on our derived black hole mass density, we calculate the contribution to the XRB from the ADAFs in faint AGNs/normal galaxies with a given Eddington ratio distribution, which is mostly in the hard X-ray energy band with an energy peak at {approx}200 keV. The growth of massive black holes during the ADAF phase can therefore be constrained with the observed XRB. Combining an AGN population synthesis model with our results, we find that the fitting on the observed XRB, especially at the hard X-ray energy band with {approx_gt}100 keV, is improved provided the contribution of the ADAFs in low-luminosity AGNs/normal galaxies is properly included. It is found that less than {approx}15% of local massive black hole mass density was accreted during ADAF phases. We suggest that more accurate measurements of the XRB in the energy band with {approx_gt}100 keV in the future may help constrain the growth of massive black holes at their late stage. We also calculate their contribution to the extragalactic {gamma}-ray background (EGRB), and find that less than {approx}1% of the observed EGRB is contributed by the ADAFs in these faint sources.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTI-STRANDED AND MULTI-THERMAL SOLAR CORONAL LOOPS: EVIDENCE FROM HINODE X-RAY TELESCOPE AND EUV IMAGING SPECTROMETER DATA

Data from the X-Ray Telescope (XRT) and the EUV Imaging Spectrometer (EIS) on the Japanese/USA/UK Hinode spacecraft were used to investigate the spatial and thermal properties of an isolated quiescent coronal loop. We constructed differential emission measure (DEM) curves using Monte Carlo based, iterative forward fitting algorithms. We studied the loop as a whole, in segments, in transverse cuts, and point-by-point, always with some form of background subtraction, and find that the loop DEM is neither isothermal nor extremely broad, with approximately 96% of the EM between 6.2 {<=}log T{<=} 6.7, and an EM-weighted temperature of log T = 6.48 {+-} 0.16. We find evidence for a gradual change in temperature along the loop, with log T increasing only by {approx}0.1 from the footpoints to the peak. The combine XRT-EIS data set does a good job of constraining the temperature distribution for coronal loop plasma. Our studies show that the strong constraints at high and low temperatures provided by the combined data set are crucial for obtaining reasonable solutions. These results confirm that the observations of at least some loops are not consistent with isothermal plasma, and therefore cannot be modeled with a single flux tube and must be multi-stranded.

79 ASTRONOMY AND ASTROPHYSICS↗