Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Polarized Light Microscopy

Polarized light microscopy (PLM) is a technique which employs the use of polarizing filters to obtain substantial optical property information about the material which is being observed. This information can be combined with other microscopy techniques to confirm or elucidate the identity of an unknown material, determine whether a particular contaminant is present (as with asbestos analysis), or to provide important information that can be used to refine a manufacturing or chemical process. PLM was the major microscopy technique in use for identification of materials for nearly a century since its introduction in 1834 by William Fox Talbot, as other techniques such as SEM (Scanning Electron Microscopy), FTIR (Fourier Transform Infrared spectroscopy), XPD (X-ray Powder Diffraction), and TEM (Transmission Electron Microscopy) had not yet been developed. Today, it is still the only technique approved by the Environmental Protection Agency (EPA) for asbestos analysis, and is often the technique first applied for identification of unknown materials. PLM uses different configurations in order to determine different material properties. With each configuration additional clues can be gathered, leading to a conclusion of material identity. With no polarizing filter, the microscope can be used just as a stereo optical microscope, and view qualities such as morphology, size, and number of phases. With a single polarizing filter (single polars), additional properties can be established, such as pleochroism, individual refractive indices, and dispersion staining. With two polarizing filters (crossed polars), even more can be deduced: isotropy vs. anisotropy, extinction angle, birefringence/degree of birefringence, sign of elongation, and anomalous polarization colors, among others. With the use of PLM many of these properties can be determined in a matter of seconds, even for those who are not highly trained. McCrone, a leader in the field of polarized light microscopy, often advised, If you cant determine a specific optical property of a particle after two minutes, move onto another configuration. Since optical properties can be seen so very quickly and easily under polarized light, it is only necessary to spend a maximum of two minutes on a technique to determine a particular property, though often only a few seconds are required.

Engineering↗

Diaplectic Glass Content in Experimentally Shock-loaded Quartz Determined by X-Ray Powder Diffraction

Quartz is the most common mineral of terrestrial crustal rocks and thus a widespread indicator for impact cratering and associated shock metamorphism. Planar deformation features (PDFs) are among the most prominent and diagnostic shock features in quartz and they represent thin lamellae of glass that formed via solid-state transformations. This socalled 'diaplectic' glass becomes pervasive at higher pressures and results in optically isotropic and X-ray-amorphous phases that resemble texturally the original quartz grains (without evidence of melt flow). In the past, it has been shown that the amount of this amorphous material in experimentally shock-loaded quartz correlates with peak shock pressure. Both reports derive the glass content from density measurements of individual crystals employing the equation X(%) = (rho(sub x) - rho(sub 0))/(rho(sub x) - rho(sub gl)), where x and 0 stands for X-ray and average (optical) density, respectively. The density of glass, rho(sub gl), was adopted as 2.2 g/cu cm. Though the same procedures had been applied, the resulting glass content differs significantly among the above studies. In the present study, we are using a new approach based solely on the integral intensity of a single, carefully selected reflection in the XRD pattern, and we will compare our data to those reported in the literature.

Skala, R.↗

Feasibility investigation of integrated optics Fourier transform devices

The possibility of producing an integrated optics data processing device based upon Fourier transformations or other parallel processing techniques, and the ways in which such techniques may be used to upgrade the performance of present and projected NASA systems were investigated. Activities toward this goal include; (1) production of near-diffraction-limited geodesic lenses in glass waveguides; (2) development of grinding and polishing techniques for the production of geodesic lenses in LiNbO3 waveguides; (3) development of a characterization technique for waveguide lenses; and (4) development of a theory for corrected aspheric geodesic lenses. A holographic subtraction system was devised which should be capable of rapid on-board preprocessing of a large number of parallel data channels. The principle involved is validated in three demonstrations.

Verber, C. M.↗

Theory of crossed-beam diffraction gratings

The operation of crossed-beam gratings is analyzed in terms of diffraction efficiency and beam quality, following Solymar's method's. General solutions for arbitrary beam widths, general beam profiles, and illumination with two beams are derived. A scheme for improving the beam quality of these gratings is proposed. The analysis should be useful in integrated optics for designing beam expanders, beam contractors, and mirrors, and for analyzing waveguide interferometers.

Kenan, R. P.↗

Holographic, particle imaging and data reduction at Spectron Development Laboratores

Spectron has been deeply involved in the development and use of a wide variety of particle and flow diagnostic, electro optical instruments. Holography and imaging systems have played an important role in this work, but the extraction of data from images and holograms have always presented a limit to their use. Systems and techniques were devised to speed up and automate the extraction of data from holographic and conventional interferograms, particle images and holograms, and other types of optical flow visualization techniques. An IBM/AI based image analyzer was developed that is capable of automatically analyzing many useful image types including interferograms. A key feature of this system is the low total cost of the required hardware. In the particle field work, a commercial diffraction field analyzer was adopted to the image reconstructed from a hologram. This could expand the use of holography in particle diagnostics greatly.

Trolinger, James D.↗

Fatigue damage study in aluminum-2024 T3 alloys

The grain structure of aluminum 2024, a commonly used commercial alloy is investigated, and these findings are correlated with the fatigue property of the material. Samples of aluminum 2024 were polished and etched in different reagents. Optical micrographs (at 500X) of samples etched in Keller's reagent revealed grain boundaries as well as some particles present in the microstructure. Normal x-ray scans of samples etched for different intervals of time in Keller's reagent indicate no significant variations in diffraction peak positions; however, the width of the rocking curve increased with the time of etching. These results are consistent with the direct dependence of the width of the rocking curve on the range of grain orientation. Etching removes the preferred orientation layer of the sample produced by polishing; thereby, causing the width to increase.

Ferguson, Milton W.↗

Partial Spreading of a Laser Beam into a Light Sheet by Shock Waves and Its Use as a Shock Detection Technique

It is observed that when a laser beam is allowed to fall on a shock surface at a grazing incidence, a small part of the beam spreads out in a thin, diverging sheet of light normal to the surface, and both upstream and downstream of the shock. The phenomenon is visualized by observing a cross section of the light sheet on a screen placed normal to the laser path after it touches a shock. The light sheet disappears when the beam is moved to any other locations where there is no shock or the beam pierces the shock surface, i.e., at a non-grazing incidence. The spread angle of the light sheet is considerably higher than the angle by which the beam may bend as it passes through the shock, which produces a small difference of refractive index. Various details indicate that the spread light is a result of diffraction of a small part of the laser beam by the shock whose thickness is nearly the same as that of the laser wavelength. Shocks formed in underexpanded free jets of fully expanded Mach numbers 1.4 to 1.8 are used for this experiment. The above optical phenomenon is used as the basis of a novel shock detection technique which depends on sensing the spread light using a photomultiplier tube (PMT). The locations of the shock surfaces in the underexpanded supersonic jet, obtained using this technique, match with those inferred from the Schlieren photographs and velocity measurements. Moreover, if the shock oscillates, a periodic PMT signal is obtained which provides information about the frequency and amplitude of shock motion.

Panda, J.↗

Optical device enables small detector to see large field of view

Optical device images the sun on a mask that transmits it or prevents its transmission to a photodetector behind the mask depending on image position on the mask. The device uses a pinhole as the image former to provide a large field of view and diffraction-limited resolution.

Arndt, J. H.↗

Measurement and modeling of land mobile satellite propagation at UHF and L-band

A propagation experiment is described in which a stratospheric balloon served as a transmitter platform at 870 and 1502 MHz in simulation of a land mobile satellite. A vehicle followed the drifting balloon along roads of western Texas and New Mexico, collecting at L-band amplitude and phase, and at UHF amplitude information only for elevation angles between 25 and 45 deg. The data obtained have been analyzed and are presented along with results from modeling of multipath scattering and roadside tree attenuation. The signal, with variations caused by multipath propagation and tree shadowing, was reduced by 3 dB at L-band and 2 dB at UHF for one percent of all locations. A median ratio of 3.9 was found between peak-to-peak phase (degrees) and power (dB) fluctuations. The ratio between L-band and UHF dB attenuation averages varied from 1.3 to 1.0 at fade levels from 6 to 23 dB. Optical sky brightness was measured and used to predict fade distribution with great accuracy. A single-scatterer multipath model is introduced. It is used to duplicate some of the measured data and to show the dependence of power variations on satellite elevation angle. Using Fresnel diffraction theory, the attenuation caused by a model tree was calculated to be near 10 dB and the maximum fade was found to increase by the logarithm of the number of branches.

Vogel, Wolfhard J.↗

LDEF thermal control coatings post-flight analysis

The optical, physical, and chemical properties of selected spacecraft thermal control coatings, exposed for 10 months and 5.8 years on the leading edge (Row 9) of the LDEF, are reported. The following coatings were used: quartz/silver optical solar reflector; silvered FEP Teflon; S-13GLO, YB-71, and A-276 white paints; black paint; and sputter deposited coatings over graphite-epoxy composite substrates. The solar absorptance, total normal emittance, scanning electron and X-ray photoelectron microscopy, and X-ray diffraction analyses will be compared for the control, the 10 month exposed, and the 5.8 year exposed specimens. Data suggests that the high atomic flux over the last 6 months of the LDEF mission may have influenced the results from from this coatings experiment.

Slemp, Wayne S.↗

Liquid Crystal on Silicon Wavefront Corrector

A low cost, high resolution, liquid crystal on silicon, spatial light modulator has been developed for the correction of huge aberrations in an optical system where the polarization dependence and the chromatic nature are tolerated. However, the overall system performance suggests that this device is also suitable for real time correction of aberration in human eyes. This device has a resolution of 1024 x 768, and is driven by an XGA display driver. The effective stroke length of the device is 700 nm and 2000 nm for the visible and IR regions of the device, respectively. The response speeds are 50 Hz and 5 Hz, respectively, which are fast enough for real time adaptive optics for aberrations in human eyes. By modulating a wavefront of 2 pi, this device can correct for arbitrary high order wavefront aberrations since the 2-D pixel array is independently controlled by the driver. The high resolution and high accuracy of the device allow for diffraction limited correction of the tip and tilt or defocus without an additional correction loop. We have shown that for every wave of aberration, an 8 step blazed grating is required to achieve high diffraction efficiency around 80%. In light of this, up to 125 waves peak to valley of tip and tilt can be corrected if we choose the simplest aberration. Corrections of 34 waves of aberration, including high order Zernicke terms in a high magnification telescope, to diffraction limited performance (residual wavefront aberration less than 1/30 lambda at 632.8 nm) have been observed at high efficiency.

Pouch, John↗

Laser Beam Steering/shaping for Free Space Optical Communication

The 2-D Optical Phased Array (OPA) antenna based on a Liquid Crystal On Silicon (LCoS) device can be considered for use in free space optical communication as an active beam controlling device. Several examples of the functionality of the device include: beam steering in the horizontal and elevation direction; high resolution wavefront compensation in a large telescope; and beam shaping with the computer generated kinoform. Various issues related to the diffraction efficiency, steering range, steering accuracy as well as the magnitude of wavefront compensation are discussed.

Wang, Xinghua↗

Rectangular Luneburg-type lenses for integrated optics

Compact Luneburg-type lenses of rectangular outline as viewed from above have been made by thermal evaporation of As2S3 glass onto single-mode LiNbO3:Ti waveguides through suitably shaped masks and subsequent exposure of the glass to ultraviolet light. The best lenses had speeds of f/5.5 at an aperture of 10 mm and focal spots at reduced aperture about 1.2 times the diffraction-limited size. These lenses have a field of view of at least 25 degrees inside the waveguide.

Wood, V. E.↗

Time and space integrating acousto-optic folded spectrum processing for SETI

Time and space integrating folded spectrum techniques utilizing acousto-optic devices (AOD) as 1-D input transducers are investigated for a potential application as wideband, high resolution, large processing gain spectrum analyzers in the search for extra-terrestrial intelligence (SETI) program. The space integrating Fourier transform performed by a lens channels the coarse spectral components diffracted from an AOD onto an array of time integrating narrowband fine resolution spectrum analyzers. The pulsing action of a laser diode samples the interferometrically detected output, aliasing the fine resolution components to baseband, as required for the subsequent charge coupled devices (CCD) processing. The raster scan mechanism incorporated into the readout of the CCD detector array is used to unfold the 2-D transform, reproducing the desired high resolution Fourier transform of the input signal.

Wagner, K.↗

Radar transponder antenna pattern analysis for the space shuttle

In order to improve tracking capability, radar transponder antennas will soon be mounted on the Shuttle solid rocket boosters (SRB). These four antennas, each being identical cavity-backed helices operating at 5.765 GHz, will be mounted near the top of the SRB's, adjacent to the intertank portion of the external tank. The purpose is to calculate the roll-plane pattern (the plane perpendicular to the SRB axes and containing the antennas) in the presence of this complex electromagnetic environment. The large electrical size of this problem mandates an optical (asymptotic) approach. Development of a specific code for this application is beyond the scope of a summer fellowship; thus a general purpose code, the Numerical Electromagnetics Code - Basic Scattering Code, was chosen as the computational tool. This code is based on the modern Geometrical Theory of Diffraction, and allows computation of scattering of bodies composed of canonical problems such as plates and elliptic cylinders. Apertures mounted on a curved surface (the SRB) cannot be accomplished by the code, so an antenna model consisting of wires excited by a method of moments current input was devised that approximated the actual performance of the antennas. The improvised antenna model matched well with measurements taken at the MSFC range. The SRB's, the external tank, and the shuttle nose were modeled as circular cylinders, and the code was able to produce what is thought to be a reasonable roll-plane pattern.

Radcliff, Roger↗

Technology Demonstrator for Direct Polishing of a 50cm C/SiC Ultra Light Mirror

The NRSU portion of the contract was completed on schedule and within acceptable limits of the estimated cost. The lapping of the substrate started on schedule, and completed ahead of schedule. The polishing of the substrate was begun ahead of schedule, and was completed approximately one month ahead of schedule. It is our opinion that the substrate meets the requirements of "diffraction limited performance at 2 microns" over the measured 16 in. area. The final photos suggest that there may be edge roll-off beyond the 16 in. diameter. However, we cannot quantify this. It is our opinion that this material is suitable for use in lightweight optics as long as cladding of some type is used (Silicon, SiC, Sol-Gel, etc), as the bare material itself is too "porous" to obtain a high quality finish. We feel that this part was at the low limit of structural integrity required to mechanically polish to this level of figure requirement. Any lesser structural integrity would require some form of "non contact" figuring.

Scribner, Ken↗

Image motion compensation on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

The SOUP experiment on Spacelab 2 includes a 30 cm visible light telescope and focal plane package mounted on the Instrument Pointing System (IPS). Scientific goals of the experiment dictate pointing stability requirements of less than 0.05 arcsecond jitter over periods of 5-20 seconds. Quantitative derivations of these requirements from two different aspects are presented: (1) avoidance of motion blurring of diffraction-limited images; (2) precise coalignment of consecutive frames to allow measurement of small image differences. To achieve this stability, a fine guider system capable of removing residual jitter of the IPS and image motions generated on the IPS cruciform instrument support structure has been constructed. This system uses solar limb detectors in the prime focal plane to derive an error signal. Image motion due to pointing errors is compensated by the agile secondary mirror mounted on piezoelectric transducers, controlled by a closed-loop servo system.

Tarbell, T. D.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗