Raman structural studies of the nickel electrode

Raman spectroscopy is sensitive to empirically controlled nickel electrode structural variations, and has unique potential for structural characterization of these materials. How the structure relates to electrochemical properties is examined so that the latter can be more completely understood, controlled, and optimized. Electrodes were impregnated and cycled, and cyclic voltammetry is being used for electrochemical characterization. Structural variation was observed which has escaped detection using other methods. Structural changes are induced by: (1) cobalt doping, (2) the state of change or discharge, (3) the preparation conditions and type of buffer used, and (4) the formation process. Charged active mass has an NiOOH-type structure, agreeing with X-ray diffraction results. Discharged active mass, however, is not isostructural with beta-Ni(OH)2. Chemically prepared alpha phases are not isostructural either. A disordered structural model, containing point defects, is proposed for the cycled materials. This model explains K(+) incorporation. Band assignments were made and spectra interpreted for beta-Ni(OH)2, electrochemical NiOOH and chemically precipitated NiOOH.

Cornilsen, B. C.↗

Locating Electron Traps In A CCD

"Pocket pumping" is technique for mapping sizes of electron-trapping defects and picture elements within which traps located in charge-coupled device (CCD). Two kinds of traps: forward and reverse. Pocket pumping relies on fact that in terms of charges measurable by external circuitry, forward traps affect only forward, while reverse traps affect only reverse, transfer of charge along row or column of picture elements. Charges in picture elements shifted back and forth many times to amplify trapping effect by repetition. Traps smaller than 1 electron detected by this method.

Janesick, James↗

HCIT Broadband Contrast Performance Sensitivity Studies

One of the important milestones of the TPF Coronagraph project is to demonstrate the ability to predict the performance sensitivities of the system at levels consistent with exo-planet detection requirement. We want to gain some general understanding about the potentials and the limitations of the current single-Deformable-Mirror (DM) High-contrast imaging testbed (HCIT) system through modeling and simulations. Specifically, we want to understand the effects of some common errors on the EFC-based control of e-field over a half dark-hole region and broadband contrast. Investigated errors include: (1) Absorbing particles on a flat-mirror (2) Defects on the Occulter surface (3) Dead actuators on the DM. We also investigated the effects of control bandwidth on the broadband contrast. We used a MACOS-based simulation algorithm which (1) combines a ray trace, diffraction model, & a broadband wavefront control algorithm (2) is capable of performing full three-dimensional near-field diffraction analysis

exoplanets↗

Quantum Sensing of Insulator‐to‐Metal Transitions in a Mott Insulator

Nitrogen vacancy (NV) centers, optically active atomic defects in diamond, have attracted tremendous interest for quantum sensing, network, and computing applications due to their excellent quantum coherence and remarkable versatility in a real, ambient environment. Taking advantage of these strengths, this paper reports on NV-based local sensing of the electrically driven insulator-to-metal transition (IMT) in a proximal Mott insulator. The resistive switching properties of both pristine and ion-irradiated VO 2 thin film devices are studied by performing optically detected NV electron spin resonance measurements. These measurements probe the local temperature and magnetic field in electrically biased VO 2 devices, which are in agreement with the global transport measurement results. In pristine devices, the electrically driven IMT proceeds through Joule heating up to the transition temperature while in ion-irradiated devices, the transition occurs nonthermally, well below the transition temperature. Here, the results provide direct evidence for nonthermal electrically induced IMT in a Mott insulator, highlighting the significant opportunities offered by NV quantum sensors in exploring nanoscale thermal and electrical behaviors in Mott materials.

McLaughlin, Nathan J.↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Identification of the Ga interstitial in Al(x)Ga(1-x)As by optically detected magnetic resonance

A new optically detected magnetic resonance spectrum in Al(x)Ga(1-x)As is reported and assigned to native Ga interstitials. Luminescence-quenching signals were observed over the energy region from 0.75 to 1.1 eV. The optically detected magnetic resonance is nearly isotropic, with spin-Hamiltonian parameters g = 2.025 + or - 0.006, central hyperfine splitting A(Ga-69) = 0.050 + or - 0.001/cm, and A(Ga-71) = 0.064 + or - 0.001/cm for H near the 001 line. The strong hyperfine coupling denotes an electronic state of A1 symmetry, which current theories predict for the Ga interstitial but not the Ga antisite. The slight anisotropy probably indicates that the Ga(i) is paired with a second, unknown defect.

Kennedy, T. A.↗

Calcium citrate without aluminum antacids does not cause aluminum retention in patients with functioning kidneys

It has been suggested that calcium citrate might enhance aluminum absorption from food, posing a threat of aluminum toxicity even in patients with normal renal function. We therefore measured serum and urinary aluminum before and following calcium citrate therapy in patients with moderate renal failure and in normal subjects maintained on constant metabolic diets with known aluminum content (967-1034 mumol/day, or 26.1-27.9 mg/day, in patients and either 834 or 1579 mumol/day, or 22.5 and 42.6 mg/day, in normal subjects). Seven patients with moderate renal failure (endogenous creatinine clearance of 43 ml/min) took 50 mmol (2 g) calcium/day as effervescent calcium citrate with meals for 17 days. Eight normal women received 25 mmol (1 g) calcium/day as tricalcium dicitrate tablets with meals for 7 days. In patients with moderate renal failure, serum and urinary aluminum were normal before treatment at 489 +/- 293 SD nmol/l (13.2 +/- 7.9 micrograms/l) and 767 +/- 497 nmol/day (20.7 +/- 13.4 micrograms/day), respectively. They remained within normal limits and did not change significantly during calcium citrate treatment (400 +/- 148 nmol/l and 600 +/- 441 nmol/day, respectively). Similarly, no significant change in serum and urinary aluminum was detected in normal women during calcium citrate administration (271 +/- 59 vs 293 +/- 85 nmol/l and 515 +/- 138 vs 615 +/- 170 nmol/day, respectively). In addition, skeletal bone aluminum content did not change significantly in 14 osteoporotic patients (endogenous creatinine clearance of 68.5 ml/min) treated for 24 months with calcium citrate, 10 mmol calcium twice/day separately from meals (29.3 +/- 13.9 ng/mg ash bone to 27.9 +/0- 10.4, P = 0.727). In them, histomorphometric examination did not show any evidence of mineralization defect. Thus, calcium citrate given alone without aluminum-containing drugs does not pose a risk of aluminum toxicity in subjects with normal or functioning kidneys, when it is administered on an empty stomach at a recommended dose of 20 mmol calcium/day.

Non-NASA Center↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

Nonlocal metasurface for circularly polarized light detection

Modern-day sensing and imaging applications increasingly rely on accurate measurements of the primary physical quantities associated with light waves: intensity, wavelength, directionality, and polarization. These are conventionally performed with a series of bulky optical elements, but recently, it has been recognized that optical resonances in nanostructures can be engineered to achieve selective photodetection of light waves with a specific set of predetermined properties. Here, we theoretically illustrate how a thin silicon layer can be patterned into a dislocated nanowire-array that affords detection of circularly polarized light with an efficiency that reaches the theoretical limit for circular dichroism of a planar detector in a symmetric external environment. The presence of a periodic arrangement of dislocations is essential in achieving such unparalleled performance as they enable selective excitation of nonlocal, guided-mode resonances for one handedness of light. We also experimentally demonstrate compact, high-performance chiral photodetectors created from these dislocated nanowire-arrays. This work highlights the critical role defects can play in enabling new nanophotonic functions and devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of ultrasonic signature analysis for fatigue detection in complex structures

Ultrasonic signature analysis shows promise of being a singularly well-suited method for detecting fatigue in structures as complex as aircraft. The method employs instrumentation centered about a Fourier analyzer system, which features analog-to-digital conversion, digital data processing, and digital display of cross-correlation functions and cross-spectra. These features are essential to the analysis of ultrasonic signatures according to the procedure described here. In order to establish the feasibility of the method, the initial experiments were confined to simple plates with simulated and fatigue-induced defects respectively. In the first test the signature proved sensitive to the size of a small hole drilled into the plate. In the second test, performed on a series of fatigue-loaded plates, the signature proved capable of indicating both the initial appearance and subsequent growth of a fatigue crack. In view of these encouraging results it is concluded that the method has reached a sufficiently advanced stage of development to warrant application to small-scale structures or even actual aircraft.

Zuckerwar, A. J.↗

NASA Tech Briefs, November 2010

Topics covered include: Portable Handheld Optical Window Inspection Device; Salience Assignment for Multiple-Instance Data and Its Application to Crop Yield Prediction; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems ; Predicting Long-Range Traversability from Short-Range Stereo-Derived Geometry; Browser-Based Application for Telemetry Monitoring of Robotic Assets; Miniature Low-Noise G-Band I-Q Receiver; Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers; Differential Resonant Ring YIG Tuned Oscillator; Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines; Reducing Seal Adhesion in Low Impact Docking Systems; Optimal Flow Control Design; Corrosion-Resistant Container for Molten-Material Processing; Reusable Hot-Wire Cable Cutter; Deployment of a Curved Truss; High-Volume Airborne Fluids Handling Technologies to Fight Wildfires; Modeling of Alkane Oxidation Using Constituents and Species; Fabrication of Lanthanum Telluride 14-1-11 Zintl High-Temperature Thermoelectric Couple; A Computer Model for Analyzing Volatile Removal Assembly; Analysis of Nozzle Jet Plume Effects on Sonic Boom Signature; Optical Sidebands Multiplier; Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers; Self-Nulling Beam Combiner Using No External Phase Inverter; Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis; Maximum Likelihood Time-of-Arrival Estimation of Optical Pulses via Photon-Counting Photodetectors; Handheld White Light Interferometer for Measuring Defect Depth in Windows; Decomposition Algorithm for Global Reachability on a Time-Varying Graph; Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids; Efficient Web Services Policy Combination; Using CTX Image Features to Predict HiRISE-Equivalent Rock Density; Isolation of the Paenibacillus phoenicis, a Spore-Forming Bacterium; Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy; Cell Radiation Experiment System; Process to Produce Iron Nanoparticle Lunar Dust Simulant Composite; Inversion Method for Early Detection of ARES-1 Case Breach Failure; Use of ILTV Control Laws for LaNCETS Flight Research;and Evaluating Descent and Ascent Trajectories Near Non-Spherical Bodies.

Source record↗

Mineral detection of neutrinos and dark matter. A whitepaper

Minerals are solid state nuclear track detectors — nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred °C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials at room temperature). The damage features from the O (50) MeV fission fragments left by spontaneous fission of 238U and other heavy unstable isotopes have long been used for fission track dating of geological samples. Laboratory studies have demonstrated the readout of defects caused by nuclear recoils with energies as small as O (1) keV. This whitepaper discusses a wide range of possible applications of minerals as detectors for E R ≳ O (1) keV nuclear recoils: Using natural minerals, one could use the damage features accumulated over O (10) Myr–O (1) Gyr to measure astrophysical neutrino fluxes (from the Sun, supernovae, or cosmic rays interacting with the atmosphere) as well as search for Dark Matter. Using signals accumulated over months to few-years timescales in laboratory-manufactured minerals, one could measure reactor neutrinos or use them as Dark Matter detectors, potentially with directional sensitivity. Research groups in Europe, Asia, and America have started developing microscopy techniques to read out the O (1)–O (100) damage features in crystals left by O (0.1)–O (100) keV nuclear recoils. We report on the status and plans of these programs. Furthermore, the research program towards the realization of such detectors is highly interdisciplinary, combining geoscience, material science, applied and fundamental physics with techniques from quantum information and Artificial Intelligence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revealing the complex chemistry of grain boundaries in K-doped BaFe 2 As 2 with atom probe tomography

Iron-based superconductors have attractive properties for high-field applications, but there is a lack of understanding of the effect of grain boundary chemistry on the in-field performance. The near atomic-scale resolution, ppm sensitivity and 3D analysis offered by atom probe tomography make it a powerful tool to investigate the nanoscale structure and chemistry of these defects in fine-grained K-doped BaFe 2 As 2 samples. A computational method to systematically extract and compare the Gibbsian interfacial excess of chemical species across grain boundaries has been explored in this work. The robustness of the method has been tested by evaluating the effects of selected variables on simulated APT datasets. The accuracy and precision of the calculated Gibbsian interfacial excess were found to be stable over a range of analysis conditions: varying grain boundary widths and detection efficiencies, spatial precisions below 1.5 nm, and bin widths between 1.2 and 1.6 nm. For the K-doped BaFe 2 As 2 samples studied, segregation of As, Ba, K and impurities of O, Na, and Sb were found at grain boundaries. The Gibbsian excess values were found to vary widely between different boundaries, showing the complexity of the grain boundary chemistry in this material. Possible links between the observed critical current density (Jc) of these samples and their nano- and micro-structure have also been investigated and discussed.

36 MATERIALS SCIENCE↗

Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of High Temperature Composite Materials

The increased use of high-temperature composite materials in modern and next generation aircraft and spacecraft have led to the need for improved nondestructive evaluation and health monitoring techniques. Such technologies are desirable to improve quality control, damage detection, stress evaluation and temperature measurement capabilities. Novel eddy current sensors and sensor arrays, such as Meandering Winding Magnetometers (MWMs) have provided alternate or complimentary techniques to ultrasound and thermography for both nondestructive evaluation (NDE) and structural health monitoring (SHM). This includes imaging of composite material quality, damage detection and .the monitoring of fiber temperatures and multidirectional stresses. Historically, implementation of MWM technology for the inspection of the Space Shuttle Orbiter Reinforced Carbon-Carbon Composite (RCC) leading edge panels was developed by JENTEK Sensors and was subsequently transitioned by NASA as an operational pre and post flight in-situ inspection at the Kennedy Space Center. A manual scanner, which conformed'automatically to the curvature of the RCC panels was developed and used as a secondary technique if a defect was found during an infrared thermography screening, During a recent proof of concept study on composite overwrapped pressure vessels (COPV's), three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed excellent correlation with actual surface strain gage measurements. Recent advancements of this technology have been made applying MWM sensor technology for scanning COPVs for mechanical damage. This presentation will outline the recent advance~ in the MWM.technology and the development of MWM techniques for NDE and SHM of carbon wra~ped composite overwrapped pressure vessels (COPVs) including the measurement of internal stresses via a surface mounted sensor array. In addition, this paper will outline recent efforts to produce sensors capable of making real-time measurements at temperatures up to 850 C, and discuss previous results demonstrating capability to monitor carbon fiber temperature changes within a composite material.

Russell, Richard↗

Autonomous scanning probe microscopy investigations over WS2 and Au{111}

Abstract Individual atomic defects in 2D materials impact their macroscopic functionality. Correlating the interplay is challenging, however, intelligent hyperspectral scanning tunneling spectroscopy (STS) mapping provides a feasible solution to this technically difficult and time consuming problem. Here, dense spectroscopic volume is collected autonomously via Gaussian process regression, where convolutional neural networks are used in tandem for spectral identification. Acquired data enable defect segmentation, and a workflow is provided for machine-driven decision making during experimentation with capability for user customization. We provide a means towards autonomous experimentation for the benefit of both enhanced reproducibility and user-accessibility. Hyperspectral investigations on WS 2 sulfur vacancy sites are explored, which is combined with local density of states confirmation on the Au{111} herringbone reconstruction. Chalcogen vacancies, pristine WS 2 , Au face-centered cubic, and Au hexagonal close-packed regions are examined and detected by machine learning methods to demonstrate the potential of artificial intelligence for hyperspectral STS mapping.

36 MATERIALS SCIENCE↗

Field ionization device used for measuring the pulse height defect of He/+/ in silicon

A neutral particle detector using field ionization and liquid-nitrogen-cooled solid state detectors has been developed to investigate the pulse height defect of low energy He(+) ions in silicon. The field ionization tip is fabricated from a short length of tungsten wire; a typical detector is of the surface-barrier Si type with a thin Au window and low capacitance (about 15 pF); the assembly is mounted in a cylindrical vacuum chamber which is pumped to about 10 to the -6th torr. As an example, pulse height distributions for He(+) and H(+) taken at tip bias of 25.7 kV are presented. The detected energy of the H and He ions are studied as a function of the actual energies of accelerated ions, for a detector having a gold front conducting surface layer of 32 micrograms/sq cm.

Curtis, C. C.↗

3D Broadband, Noncontact, and Nonlinear Phased Array

Researchers at Los Alamos have developed a 3D broadband, noncontact, and nonlinear ultrasonic phased array technology that enables businesses to characterize and identify cracks and defects using laserbased sensing at ultra-high resolution. It can be applied to a wide range of commercial and industrial markets, e.g., aerospace, aeronautical, nuclear energy, oil and gas, and civil and material engineering and more broadly to those interested in the non-destructive evaluation (NDE) of materials and structures. Traditional phased-array technology for subsurface imaging operate over a narrow frequency range, with a limited number of sensors, using one type of ultrasonic waves which may decrease the likelihood of detecting a structural material crack. This technology fills the information gap by utilizing the potential of laser-based sensing to remove all these limitations. We are seeking a commercialization partner to license the technology or fund us through a Cooperative Research and Development Agreement (CRADA) to further develop a usable product for commercial purposes.