Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CONTROL SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Battery test expert systems

The characteristics of NIHBES (nickel-hydrogen battery expert system) are described, with attention also given to NICBES-2 (nickel-cadmium battery expert system-2). The nickel-hydrogen battery testbed is set up almost identically to the nickel-cadmium battery testbed, with the exceptions of no battery protection and reconditioning circuits (BPRCs) and the frequency of transmission of data. The Ni-H2 testbed has no BPRCs and the data are transmitted every 30 s instead of every minute. An expert system shell was chosen to develop this particular expert system. The GoldWorks expert system shell from Gold Hill Computers was chosen for the task. NIHBES will extract the desired data and return fault diagnosis, status and advice, and decision support. Expert systems have been proven to be viable tools in the control and monitoring of space power systems. Presently, the DDAS (digital data acquisition system) monitors and controls the orbit time, and is responsible for limit checking, data acquisition, and data summaries. It is concluded that in the future control of the Hubble Space Telescope breadboard will be passed to NIHBES. NIHBES will be more beneficial to the testbed than the DDAS alone due to the limitations of the DDAS. The DDAS cannot provide long-term trend analysis, plotting capability, fault diagnosis, or advice.

Johnson, Yvette B.↗

Improvements To Progressive Wave Tube Performance Through Closed-Loop Control

This report documents recent improvements to the acoustic and thermal control systems of the Thermal Acoustic Fatigue Apparatus (TAFA), a progressive wave tube test facility at the NASA Langley Research Center, Hampton, Virginia. A brief summary of past acoustic performance is given first to serve as a basis for comparison with the new performance data using a multiple-input, closed-loop, narrow-band controller. Performance data in the form of test section acoustic power spectral densities and coherence are presented in three of six facility configurations for a variety of input spectra. Tested spectra include uniform, two cases of pink noise, three cases of narrow-band random, a simulated launch payload bay environment for an expendable launch vehicle, and a simulated external acoustic load for the aft section of a reusable launch vehicle. In addition, a new closed-loop temperature controller and thermocouple data acquisition system are described.

Rizzi, Stephen A.↗

Development of Miniaturized High-Temperature Multi-Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings.

20 FOSSIL-FUELED POWER PLANTS↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Demand Response and Open Automated Demand Response Opportunities for Data Centers

This study examines data center characteristics, loads, control systems, and technologies to identify demand response (DR) and automated DR (Open Auto-DR) opportunities and challenges. The study was performed in collaboration with technology experts, industrial partners, and data center facility managers and existing research on commercial and industrial DR was collected and analyzed. The results suggest that data centers, with significant and rapidly growing energy use, have significant DR potential. Because data centers are highly automated, they are excellent candidates for Open Auto-DR. 'Non-mission-critical' data centers are the most likely candidates for early adoption of DR. Data center site infrastructure DR strategies have been well studied for other commercial buildings; however, DR strategies for information technology (IT) infrastructure have not been studied extensively. The largest opportunity for DR or load reduction in data centers is in the use of virtualization to reduce IT equipment energy use, which correspondingly reduces facility cooling loads. DR strategies could also be deployed for data center lighting, and heating, ventilation, and air conditioning. Additional studies and demonstrations are needed to quantify benefits to data centers of participating in DR and to address concerns about DR's possible impact on data center performance or quality of service and equipment life span.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corporate Delivery of a Global Smart Buildings Program

Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20% savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planetary spacecraft - SEPS interface design

The interactions between a spacecraft which would rendezvous with the comet Tempel II, the stage, and the mission design are summarized along with solar electric propulsion system design issues. Attention is given to data communication, the spacecraft pointing control system, spacecraft power, plasma interactions, the release of a probe to study the comet Halley, and thruster usage. It was concluded that for a planetary mission design using a low-thrust stage, the control of the mission should reside in the payload spacecraft and that the power should be provided by the stage; the NASA standard 28 VDC bus is recommended.

Pless, L. C.↗

Control Systems Cyber Security: Defense-in-Depth Strategies

Information infrastructures across many public and private domains share several common attributes regarding IT deployments and data communications. This is particularly true in the control systems domain. A majority of the systems use robust architectures to enhance business and reduce costs by increasing the integration of external, business, and control system networks. However, multi-network integration strategies often lead to vulnerabilities that greatly reduce the security of an organization, and can expose mission-critical control systems to cyber threats. This document provides guidance and direction for developing ‘defense-in-depth’ strategies for organizations that use control system networks while maintaining a multi-tier information architecture that requires: • Maintenance of various field devices, telemetry collection, and/or industrial-level process systems • Access to facilities via remote data link or modem • Public facing services for customer or corporate operations • A robust business environment that requires connections among the control system domain, the external Internet, and other peer organizations.

99 GENERAL AND MISCELLANEOUS↗

NASA metrology information system: A NEMS subsystem

the NASA Metrology Information Systems (NMIS) is being developed as a standardized tool in managing the NASA field Center's instrument calibration programs. This system, as defined by the NASA Metrology and Calibration Workshop, will function as a subsystem of the newly developed NASA Equipment Management System (NEMS). The Metrology Information System is designed to utilize and update applicable NEMS data fields for controlled property and to function as a stand alone system for noncontrolled property. The NMIS provides automatic instrument calibration recall control, instrument historical performance data storage and analysis, calibration and repair labor and parts cost data, and instrument user and location data. Nineteen standardized reports were developed to analyze calibration system operations.

German, E. S., Jr.↗

Stochastic availability analysis of operational data systems in the Deep Space Network

Existing availability models of standby redundant systems consider only an operator's performance and its interaction with the hardware performance. In the case of operational data systems in the Deep Space Network (DSN), in addition to an operator system interface, a controller reconfigures the system and links a standby unit into the network data path upon failure of the operating unit. A stochastic (Markovian) process technique is used to model and analyze the availability performance and occurrence of degradation due to partial failures are quantitatively incorporated into the model. Exact expressions of the steady state availability and proportion degraded performance measures are derived for the systems under study. The interaction among the hardware, operator, and controller performance parameters and that interaction's effect on data availability are evaluated and illustrated for an operational data processing system.

Issa, T. N.↗

Unified Beam Control System of J-PARC Linac

A beam control system has been developed for the J-PARC linac to achieve strict design goals of beam performance and beam loss suppression in the high-intensity beams. An emerging concept of unified beam control has been adopted in the system, where a unified data source, standardized control units, a unified online model, and uniform high-level application frameworks have been designed and implemented. For precise beam controls, various beam tuning algorithms have been developed and tested. Design goals of beam performance, beam stability, and beam loss suppression have been achieved in the linac.

43 PARTICLE ACCELERATORS↗

The L-CAPE Project at FNAL

The controls system at FNAL records data asynchronously from several thousand Linac devices at their respective cadences, ranging from 15Hz down to once per minute. In case of downtimes, current operations are mostly reactive, investigating the cause of an outage and labeling it after the fact. However, as one of the most upstream systems at the FNAL accelerator complex, the Linac’s foreknowledge of an impending downtime as well as its duration could prompt downstream systems to go into standby, potentially leading to energy savings. The goals of the Linac Condition Anomaly Prediction of Emergence (L-CAPE) project that started in late 2020 are (1) to apply data-analytic methods to improve the information that is available to operators in the control room, and (2) to use machine learning to automate the labeling of outage types as they occur and discover patterns in the data that could lead to the prediction of outages. We present an overview of the challenges in dealing with time-series data from 2000+ devices, our approach to developing an ML-based automated outage labeling system, and the status of augmenting operations by identifying the most likely devices predicting an outage.

43 PARTICLE ACCELERATORS↗

Programming Abstractions for Managing Workflows on Tiered Storage Systems

Scientific workflows in High Performance Computing (HPC) environments are processing large amounts of data. The storage hierarchy on HPC systems is getting deeper, driven by new technologies (NVRAMs, SSDs, etc.) There is a need for new programming abstractions that allow users to seamlessly manage data at the workflow level on multi-tiered storage systems, and provide optimal workflow performance and use of storage resources. In previous work, we introduced a software architecture Managing Data on Tiered Storage for Scientific Workflows (MaDaTS) that used a Virtual Data Space (VDS) abstraction to hide the complexities of the underlying storage system while allowing users to control data management strategies. In this article, we detail the data-centric programming abstractions that allow users to manage a workflow around its data on the storage layer. The programming abstractions simplify data management for scientific workflows on multi-tiered storage systems, without affecting workflow performance or storage capacity. We measure the overheads and effectiveness introduced by the programming abstractions of MaDaTS. Our results show that these abstractions can optimally use the storage capacity in lesser capacity storage tiers, and simplify data management without adding any performance overheads.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗