Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems: Preprint

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 mus. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at the Savannah River Plutonium Processing Facility

The Aqueous Recovery System (ARS) at the Savannah River Plutonium Processing Facility (SRPPF) recovers and purifies plutonium (Pu) using aqueous chemistry techniques. The neutralization tanks in the ARS collect waste streams with various impurities and greatly reduced concentrations of Pu than are produced during aqueous processing. Criticality safety is primarily achieved in the ARS by using geometrically favorable process vessels. However, due to the geometry of neutralization tanks, each tank is administratively limited to no more than 450 g Pu, thus representing the transition from geometry to mass control. To ensure that this mass limit is not exceeded, an administrative control requires taking two samples of any solution to be sent to a neutralization tank. Normal operations are expected to result in less than 50 g Pu in a neutralization tank filled to its capacity of 250 L. Process upsets may cause an inadvertent transfer of up to 1000 g Pu to a neutralization tank, producing a system that is potentially not subcritical for all possible configurations of the tank. To ensure that a neutralization tank remains safety subcritical, passive engineered controls (e.g. changing tank geometry or adding fixed poisons), active engineered controls (e.g. interlocks), and administrative controls (e.g. soluble poisons and valve isolation) were considered and their viability evaluated. Ultimately, the team chose an administrative, dual-valve isolation strategy. This paper will thoroughly discuss the various control strategy options and why many of the options were not feasible for maintaining criticality safety.

Dressman, Phillip M. [Savannah River Nuclear Solut↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at the Savannah River Plutonium Processing Facility

The Aqueous Recovery System (ARS) at the Savannah River Plutonium Processing Facility (SRPPF) recovers and purifies plutonium (Pu) using aqueous chemistry techniques. The neutralization tanks in the ARS collect the waste streams, containing various impurities and greatly reduced concentrations of Pu, that are produced during aqueous processing. Criticality safety is primarily achieved in the ARS by using geometrically favorable process vessels. However, due to the geometry of neutralization tanks, each tank is administratively limited to no more than 450 g Pu, thus representing the transition from geometry to mass control. To ensure that this mass limit is not exceeded, an administrative control requires taking two samples of any solution to be sent to a neutralization tank. Normal operations are expected to result in less than 50 g Pu in a neutralization tank filled to its capacity of 250 L. Process upsets may cause an inadvertent transfer of up to 1000 g Pu to a neutralization tank, producing a system that is potentially not subcritical for all possible configurations of the tank. To ensure that a neutralization tank remains safety subcritical, passive engineered controls (e.g.changing tank geometry or adding fixed poisons), active engineered controls (e.g. interlocks), and administrative controls (e.g. soluble poisons and valve isolation) were considered and their viability evaluated. Ultimately, the team chose an administrative, dual-valve isolation strategy. This paper will thoroughly discuss the various control strategy options and why many of the options were not feasible for maintaining criticality safety.

Dressman, Phillip M. [Savannah River Nuclear Solut↗

Fermilab PIP-II CDS and CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗

Safe Physics-Informed Machine Learning for Dynamics and Control

This tutorial paper focuses on safe physics-informed machine learning in the context of dynamics and control, providing a comprehensive overview of how to integrate physical models and safety guarantees. As machine learning techniques enhance the modeling and control of complex dynamical systems, ensuring safety and stability remains a critical challenge, especially in safety-critical applications like autonomous vehicles, robotics, medical decision-making, and energy systems. We explore various approaches for embedding and ensuring safety constraints, including structural priors, Lyapunov and Control Barrier Functions, predictive control, projections, and robust optimization techniques. Additionally, we delve into methods for uncertainty quantification and safety verification, including reachability analysis and neural network verification tools, which help validate that control policies remain within safe operating bounds even in uncertain environments. The paper includes illustrative examples demonstrating the implementation aspects of safe learning frameworks that combine the strengths of data-driven approaches with the rigor of physical principles, offering a path toward the safe control of complex dynamical systems.

Drgona, Jan↗

Multi-Agent Control Planes for Quantum Networks: A Scalable Architecture for Autonomous Quantum Internet Management

Quantum networks are expected to enable distributed quantum computing, secure communication, and global entanglement distribution. However, operating such networks presents significant challenges, including stochastic quantum processes, fragile entanglement resources, dynamic topology, and cross-layer control requirements. Current quantum network control architectures largely rely on centralized or hierarchical controllers inspired by classical software-defined networking (SDN). While effective for small testbeds, these approaches face scalability, latency, and reliability limitations as quantum networks grow. This paper proposes a multi-agent control plane architecture for quantum networks. In this design, intelligent software agents operate at quantum nodes, repeaters, and orchestration layers, collectively managing entanglement generation, routing, purification, and scheduling. The distributed intelligence of the agent system allows the network to adapt dynamically to quantum hardware variability and environmental noise. We argue that multi-agent systems provide significant advantages over centralized control approaches, including scalability, resilience, local autonomy, and real-time adaptation. The paper discusses architectural design principles, agent coordination mechanisms, and research challenges in deploying multi-agent control planes for the emerging quantum Internet.

Alnajjar, Anees [ORNL] (ORCID:0000000237101601)↗

Adaptive Model-Free Vehicle Path-Tracking via Fast-Converging Prescribed-Time Newton-Based Extremum-Seeking Control

Model-free control (MFC) offers a simple and effective approach to automated vehicle path-tracking without requiring an explicit plant model for control law design. However, gain tuning in MFC is typically carried out through trial-and-error, which can be time-consuming and may lead to suboptimal performance. To address this limitation, extremum-seeking-based adaptive MFC has shown promise by enabling real-time adaptation of control gains, without relying on a predefined vehicle model. Nonetheless, existing ESC approaches often suffer from slow convergence. This paper integrates MFC, employing longitudinal and lateral ultra-local models of a rear-wheel-drive vehicle, with a novel prescribed-time (PT) Newton-based extremum-seeking control (ESC) strategy that ensures rapid convergence of control gains within the prescribed time. Unlike conventional gradient-based ESC methods, the PT Newton-based ESC leverages artificial delays and time-periodic gains, not only to guarantee convergence within the specified time, but also to compensate for feedback delays. Simulation results demonstrate that the proposed approach significantly improves gain adaptation speed and tracking accuracy. This work advances adaptive model-free vehicle control by offering a high-performance, delay-resilient alternative to existing ESCMFC frameworks.

Waleed khan, Muhammad [The University of Texas at ↗

Controllers for Distributed Grid Support for Power Systems using Hybrid DER plants with Electrolyzers [SWR-20-06]

This software presents the design and control for a hybrid DER site with integrated dispatchable electrolyzers. It is a comprehensive solution for regulating the dispatch of electrolyzer demand to support the grid using the respective control functions. Multiple control functions (ramp control, frequency support control, dispatch prioritization) are developed to integrate the proposed site for multiple services around load, voltage and frequency control. This allows the site owners to participate in both distribution and bulk system energy markets for grid ancillary services.

Jain, Rishabh↗

Real-time control of connected vehicles in signalized corridors using pseudospectral convex optimization

Recent advances in Connected and Automated Vehicle (CAV) technologies have opened up new opportunities to enable safe, efficient, and sustainable transportation systems. However, developing reliable and rapid speed control algorithms in highly dynamic environments with complex inter-vehicle interactions and nonlinear vehicle dynamics is still a daunting task. In this paper, we develop a novel speed control method for CAVs to produce optimal speed profiles that minimize the fuel consumption and avoid idling at signalized intersections. To this end, an optimal control problem is formulated using the information of the upcoming traffic signal to adapt vehicles' speeds to avoid frequent stop-and-go driving patterns. Here, by applying the pseudospectral discretization method and the sequential convex programming method, the computational efficiency is greatly improved, enabling potential real-time on-vehicle applications. In addition, the algorithm is implemented under a model predictive control framework to ensure online control with instant response for collision avoidance and robust vehicle coordination. The proposed algorithm is verified through numerical simulations of three different traffic scenarios. The convergence and accuracy of the proposed approach are demonstrated by comparing with a popular nonlinear solver. Furthermore, the benefit of the proposed method in both traffic mobility and fuel efficiency is validated using the speed profile determined from a traffic following model in a simulation software as the baseline.

42 ENGINEERING↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyber‐Resilient Distributed Energy Resource Control Algorithms for Smart Distribution Grids

ABSTRACT This paper focuses on the development of cyber‐resilient gradient‐based optimisation algorithms and theoretical proof for grid‐interactive distributed energy resource (DER) control to enable two grid services of virtual power plants (VPPs) dispatch and grid voltage regulation, considering the communication and security impacts. Firstly, the combined DER dispatch and voltage regulation as a real‐time gradient‐based optimisation problem is recapped. Thereafter, we consider a probabilistic traffic model to characterise packet delays and loss in a communication network, and study how the delays enter the process of information exchange among the grid measurement units, local DER controllers and the grid control centre that execute this control algorithm in a coordinated manner. Then, a strategy combining delay thresholds and message update rules is proposed to immunity the asynchrony resulting from the communications traffic and it avoids possible numerical instabilities and sensitivities of the power tracking and voltage regulation capabilities, resulting as cyber‐resilient DER control algorithms. Additionally, their convergence is theoretically proved. Effectiveness of proposed cyber‐resilient algorithms has been validated on the IEEE 37‐bus system in terms of convergence, VPP tracking and voltage regulation performance for smart distribution systems with high penetration of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Quantification for Consensus-Based Power Flow Control between Transmission and Distribution Power Systems

With increasing integration of distributed energy resources (DERs), distribution systems (DS) with DERs are expected to provide proactive grid services. The result is that power references, or known as dispatch signals, required for DS can become faster changing than in legacy power system. Consensus-based integral controls have been proposed for the purpose of coordinating power generations of DERs in DS to match the power references. These existing controls assume the integral control signal to be sufficiently slow or constant, and ignore the potential dynamics of the integral controller when tracking more varying power references. Therefore, in this paper we present an improvement for such controls by deriving the stability condition utilizing generalized Nyquist criterion. The stability condition is quantified by a set of integral gains that guarantee stability in closed-loop system without assuming a constant integral signal. A rule-of-thumb criterion is also derived to instruct the design of the consensus topology that can provide faster convergence rate for the closed-loop system. Here, the stability and convergence improvements developed in this paper are demonstrated and verified through numerical examples.

42 ENGINEERING↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗