Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Harnessing High‐Throughput Computational Methods to Accelerate the Discovery of Optimal Proton Conductors for High‐Performance and Durable Protonic Ceramic Electrochemical Cells

Abstract The pursuit of high‐performance and long‐lasting protonic ceramic electrochemical cells (PCECs) is impeded by the lack of efficient and enduring proton conductors. Conventional research approaches, predominantly based on a trial‐and‐error methodology, have proven to be demanding of resources and time‐consuming. Here, this work reports the findings in harnessing high‐throughput computational methods to expedite the discovery of optimal electrolytes for PCECs. This work methodically computes the oxygen vacancy formation energy (E V ), hydration energy (E H ), and the adsorption energies of H 2 O and CO 2 for a set of 932 oxide candidates. Notably, these findings highlight BaSn x Ce 0.8‐x Yb 0.2 O 3‐δ (BSCYb) as a prospective game‐changing contender, displaying superior proton conductivity and chemical resilience when compared to the well‐regarded BaZr x Ce 0.8‐x Y 0.1 Yb 0.1 O 3‐δ (BZCYYb) series. Experimental validations substantiate the computational predictions; PCECs incorporating BSCYb as the electrolyte achieved extraordinary peak power densities in the fuel cell mode (0.52 and 1.57 W cm −2 at 450 and 600 °C, respectively), a current density of 2.62 A cm −2 at 1.3 V and 600 °C in the electrolysis mode while demonstrating exceptional durability for over 1000‐h when exposed to 50% H 2 O. This research underscores the transformative potential of high‐throughput computational techniques in advancing the field of proton‐conducting oxides for sustainable power generation and hydrogen production.

08 HYDROGEN↗

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

Parallel processing and expert systems

Whether it be monitoring the thermal subsystem of Space Station Freedom, or controlling the navigation of the autonomous rover on Mars, NASA missions in the 1990s cannot enjoy an increased level of autonomy without the efficient implementation of expert systems. Merely increasing the computational speed of uniprocessors may not be able to guarantee that real-time demands are met for larger systems. Speedup via parallel processing must be pursued alongside the optimization of sequential implementations. Prototypes of parallel expert systems have been built at universities and industrial laboratories in the U.S. and Japan. The state-of-the-art research in progress related to parallel execution of expert systems is surveyed. The survey discusses multiprocessors for expert systems, parallel languages for symbolic computations, and mapping expert systems to multiprocessors. Results to date indicate that the parallelism achieved for these systems is small. The main reasons are (1) the body of knowledge applicable in any given situation and the amount of computation executed by each rule firing are small, (2) dividing the problem solving process into relatively independent partitions is difficult, and (3) implementation decisions that enable expert systems to be incrementally refined hamper compile-time optimization. In order to obtain greater speedups, data parallelism and application parallelism must be exploited.

Lau, Sonie↗

Electricity Bill Calculator (elecprice) v0.1.0

The Electricity Bill Calculator Library is a generic tool for manipulating the tariffs of electricity, with an emphasis on commercial Time-Of-Use (TOU) rates in the U.S. and residential Net Energy Metering tariffs in CA. Typical uses of the package are price signal generation and bill computation. To generate price signals from a specific tariff and given a time window, the tool creates a pandas dataframes containing the various components of the electricity charges, at each time step. This is particularly useful for Demand Response (DR) applications, such as price-based optimization of energy in buildings. The tool also computes bills given a building's power consumption and a specific tariff and returning the corresponding cost of electricity, as well as a breakdown per type of rate.

Prakash, Anand Krishnan↗

Extending the path for efficient extreme ultraviolet sources for advanced nanolithography

Developing efficient light sources for extreme ultraviolet (EUV) lithography is one of the most important problems of high volume manufacturing (HVM) of the next generation computer chips. Critical components of this technology are continued to face challenges in the demanding performance for HVM. Current investigations of EUV and beyond EUV (BEUV) community are focused on the dual-pulse laser produced plasma (LPP) using droplets of mass-limited targets. Two main objectives as well as challenges in the optimization of these light sources are related to enhancement of the conversion efficiency (CE) of the source and increase components lifetime of the collector optical system. These require significant experimental and computer simulation efforts. These requirements call for fine detail analysis of various plasma physics processes involved in laser target interactions and their effects on source optimization. We continued to enhance our comprehensive HEIGHTS simulation package and upgrade our CMUXE laboratories to study and optimize the efficiency of LPP sources. Integrated modeling and experimental research were done to both benchmark simulation results and to make projections and realistic predictions of the development path for powerful EUVL devices for HVM requirements. We continued the detail analysis of dual-pulse laser systems using various laser wavelengths and delay times between the two pulses. We showed that the efficiency of EUV sources can be improved utilizing the higher harmonics of Nd:YAG laser for the prepulse and the first harmonics for the main pulse, while still having lower efficiency than the combination involving CO{sub 2} laser in the range of parameters studied in this case. The differences in optimization process as well as in the source characteristics for two combinations of laser wavelengths were analyzed based on details of atomic and hydrodynamics processes during the evolving plasma plumes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

The ABCs of On-Demand Transit (ODT)

On-demand mobility - also referred to as on-demand transit (ODT) - is a form of public mobility that is flexible with respect to where and when service is provided, and ODT deployments have increased significantly in recent years. Transit agencies are becoming increasingly interested in ODT, and due to differing definitions and various service design and business model options, it can be difficult to learn about the emerging industry. This work provides an overview of the definitions of ODT, recent trends internationally and in the U.S., ODT's benefits and challenges (particularly compared to fixed-route transit), three primary service design options, system costs and funding considerations, and a metrics framework for evaluating ODT systems to ensure continued successful performance. Identified benefits include increased service areas, short ride and wait times, increased user flexibility, potential to reduce energy consumption and emissions through shared trips and smaller, right-sized vehicles, increased safety and comfort through door-to-door service, and rich data streams including granular spatio-temporal data that can be analyzed to continuously improve the service. Challenges include scaling ODT service up as small increases in ridership require additional supply to keep service quality high, serving peak times including keeping low wait times, the lack of fixed schedule being challenging for commuters, integrating ODT services with nearby transit systems, and equity for riders without smartphones who cannot track the vehicle in a mobile app. Finally, an overview of seven ODT case studies (in Texas, Missouri, New York, and Ontario, Canada) performed by NREL and related analysis of travel time, energy and emissions, costs, and equity are presented. Initial key findings include: ODT can be cost- and energy-effective compared to fixed-route transit, ODT serves more people than other transit options, and ODT system deployments can be followed by rapid growth.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient core-excited state orbital perspective on calculating x-ray absorption transitions in determinant framework

X-ray absorption spectroscopy (XAS) is an explicit probe of the unoccupied electronic structure of materials and an invaluable tool for fingerprinting various electronic properties and phenomena. Computational methods capable of simulating and analyzing such spectra are therefore in high demand for complementing experimental results and for extracting valuable insights therefrom. In particular, a recently proposed first-principles approach titled many-body XAS (MBXAS), which approximates the final (initial) state as a Slater determinant constructed from Kohn-Sham (KS) orbitals optimized in the absence (presence) of the relevant core electron has shown promising prospects in evaluating the transition amplitudes. In this article, we show that the MBXAS approach can be rederived using a transition operator expressed entirely in the basis of core-excited state KS orbitals and that this reformulation offers substantial practical and conceptual advantages. In addition to circumventing previous issues of convergence with respect to the number of unoccupied ground-state orbitals, the aforementioned representation reduces the computational expense by rendering the calculation of such orbitals unnecessary altogether. Furthermore, the reformulated approach also provides a direct pathway for comparing the many-body approximation with the so-called single-particle treatment and indicates the relative importance in observed XAS intensity of the relaxation of the valence occupied subspace induced by the core excitation. Finally, using the core-excited state basis, we define auxiliary orbitals for x-ray absorption and demonstrate their utility in explaining the spectral intensity by contrasting them with single-particle approximations to the excited state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Neural operator transformers capture bifurcating drift-wave turbulence in fusion plasma simulations

Self-consistent modeling of turbulence-driven transport is critical for optimizing confinement in magnetically confined fusion plasmas, such as tokamaks and stellarators. In particular, capturing the long-term co-evolution of turbulence, flow, and background plasma profiles remains computationally challenging. Direct numerical simulation of these multiscale, highly nonlinear processes is often demanding and impractical for real-time control or design optimization. To address this bottleneck, we investigate transformer-based neural operator partial differential equation surrogates for emulating the dynamics of drift-wave turbulence bifurcation mediated by zonal flows, using the modified Hasegawa–Wakatani (MHW) model as a prototypical system. We find that the finetuned neural operator model has excellent performance in capturing the multi-spatiotemporal-scales of MHW turbulence bifurcation and is robust to testing on rare and out-of-distribution dynamics. Specifically, we demonstrate that a single unified model accurately predicts both quasi-steady-state turbulence and a wide range of dynamical transition processes, such as nonlinear saturation, spontaneous suppression of turbulence, and the emergence of macroscopic zonal flows, over time horizons vastly exceeding the local turbulence correlation time. This computationally efficient approach establishes a strong foundation for fast, AI-based modeling of complex, multiscale phenomena in magnetized fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-space pseudopotential method for computing the vibrational Stark effect

The vibrational Stark shift is an important effect in determining the electrostatic environment for molecular or condensed matter systems. However, accurate ab initio calculations of the vibrational Stark effect are a technically demanding challenge. In this paper, we make use of density functional theory constructed on a real-space grid to expedite the computation of this effect. Our format is especially advantageous for the investigation of small molecules in finite fields as cluster boundary conditions eliminate spurious supercell interactions and allow for charged systems, while convergence is controlled by a single parameter, the grid spacing. The Stark tuning rate is highly sensitive to the interaction between anharmonicity in a vibrational mode and the applied field. To ensure this subtle interaction is fully captured, we apply three parallel approaches: a direct finite field, a perturbative method, and a molecular dynamics method. Finally, we illustrate this method by applying it to several small molecules containing C–O and C–N bonds and show that a consistent result can be obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

CoSim: A Simulator for Co-Scheduling of Batch and On-Demand Jobs in HPC Datacenters

The increasing scale and complexity of scientific applications are rapidly transforming the ecosystem of tools, methods, and workflows adopted by the high-performance computing (HPC) community. Big data analytics and deep learning are gaining traction as essential components in this ecosystem in a variety of scenarios, such as, steering of experimental instruments , acceleration of high-fidelity simulations through surrogate computations, and guided ensemble searches. In this context, the batch job model traditionally adopted by the supercomputing in-frastructures needs to be complemented with support to schedule opportunistic on-demand analytics jobs, leading to the problem of efficient preemption of batch jobs with minimum loss of progress. In this paper, we design and implement a simulator, CoSim, that enables on-the-fly analysis of the trade-offs arising between delaying the start of opportunistic on-demand jobs, which leads to longer analytics latency, and loss of progress due to preemption of batch jobs, which is necessary to make room for on-demand jobs. To this end, we propose an algorithm based on dynamic programming with predictable performance and scalability that enables supercomputing infrastructure schedulers to analyze the aforementioned trade-off and take decisions in near real-time. Compared with other state-of-art approaches using traces of the Theta pre-Exascale machine, our approach is capable of finding the optimal solution, while achieving high performance and scalability.

batch job preemption↗

MgSiP 2 : An Infrared Nonlinear Optical Crystal with a Large Non‐Resonant Phase‐Matchable Second Harmonic Coefficient and High Laser Damage Threshold

Superior infrared nonlinear optical (NLO) crystals are in urgent demand in the development of lasers and optical technologies for communications and computing. The critical challenge is to find a crystal with large non‐resonant phase‐matchable NLO coefficients and high laser damage threshold (LDTs) simultaneously, which however scale inversely. This work reports such a material, MgSiP 2, that exhibits a large second harmonic generation (SHG) coefficient of d 14 ≈ d 36 = 89 ± 5 pm V −1 at 1550 nm fundamental wavelength, surpassing the commercial NLO crystals AgGaS 2 , AgGaSe 2 , and ZnGeP 2 . First principles theory reveals the polarizability and geometric arrangement of the [SiP 4 ] tetrahedral units as the origin of this large nonlinear response. Remarkably, it also exhibits a high LDT value of 684 GW cm −2 , which is six times larger than ZnGeP 2 and three times larger than CdSiP 2 . It has a wide transparency window of 0.53–10.35 µm, allowing broadband tunability. Further, it is Type I and Type II phase‐matchable with large effective SHG coefficients of d eff,I ≈80.2 pm V −1 and d eff,II ≈73.4 pm V −1 . The outstanding properties of MgSiP 2 make it a highly attractive candidate for optical frequency conversion in the infrared.

36 MATERIALS SCIENCE↗

Joint Design of Multimodal Transit Networks and Shared Autonomous Mobility Fleets

Providing quality transit service to travelers in low-density areas, particularly travelers without personal vehicles, is a constant challenge for transit agencies. The advent of fully-autonomous vehicles (AVs) and their inclusion in mobility service fleets may allow transit agencies to offer better service and/or reduce their own capital and operational costs. This study focuses on the problem of allocating resources between transit patterns and operating (or subsidizing) shared-use AV mobility services (SAMSs) in a large metropolitan area. To address this question, a joint transit network redesign and SAMS fleet size determination problem (JTNR-SFSDP) is introduced, and a bi-level mathematical programming formulation and solution approach are presented. The upper-level problem modifies a transit network frequency setting problem (TNFSP) formulation via incorporating SAMS fleet size as a decision variable and allowing the removal of bus routes. The lower-level problem consists of a dynamic combined mode choice-traveler assignment problem (DCMC-TAP) formulation. The heuristic solution procedure involves solving the upper-level problem using a nonlinear programming solver and solving the lower-level problem using an iterative agent-based assignment-simulation approach. To illustrate the effectiveness of the modeling framework, this study uses traveler demand from Chicago along with the regions existing multimodal transit network. The computational results indicate significant traveler benefits, in terms of improved average traveler wait times, associated with optimizing the joint design of multimodal transit networks and SAMS fleets compared with the initial transit network design.

bi-level programming↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Effective closed form mathematical approach to determine kinetic constants of NR vulcanized with sulphur and accelerators at different concentrations

The basic reaction scheme due to Han and co-workers for NR vulcanized with sulphur is adopted and modified taking into account the single contributions of the different accelerators, focusing in particular on some experimental data ad hoc obtained at Pirelli’s laboratories, where NR was vulcanized at different temperatures (from 150 to 180 °C) and concentrations of sulphur, using TBBS and DPG in the mixture as co-agents. Typically, the chain reactions are initiated by the formation of macro-compounds that are responsible of the formation of the unmatured crosslinked polymer. This first reaction depends on the reciprocal concentrations of all components and their chemical nature. In presence of two accelerators, it was considered that the reactions between each single accelerator and the NR raw material occur in parallel, making the reasonable assumption that there are no mutual reactions between the two accelerators. From the kinetic scheme adopted, a closed form solution was found for the crosslink density, with the only limitation that the induction period is excluded from computations. Even kinetic constants are evaluated in closed form, avoiding a numerically demanding least-squares best fitting on rheometer experimental data. Two series of experiments available, relying into rheometer curves at different temperatures and different concentrations of sulphur and accelerator, are utilized to evaluate the fitting capabilities of the mathematical model. Very good agreement between numerical output and experimental data is experienced in all cases analysed.

36 MATERIALS SCIENCE↗

RANGE: A robust adaptive nature-inspired global explorer of potential energy surfaces

With the growing demand for realistic representations of chemical structures and the advent of exascale computing, the intelligent sampling of potential energy surfaces and efficient identification of global minima have become more essential but also more feasible. Building on prior studies demonstrating the efficiency of the Artificial Bee Colony (ABC) swarm intelligence algorithm, we report a hybrid metaheuristic framework that integrates the adaptive exploration capabilities of ABC coupled with the exploitation strengths of genetic algorithms (GA) in a scalable, Python-based implementation. The resulting tool, RANGE (Robust Adaptive Nature-inspired Global Explorer), provides seamless interfaces to multiple potential energy evaluators, either directly or via widely used Python libraries, and is designed for high-performance computing environments. We describe the implementation details of RANGE and evaluate its performance, relative to ABC- or GA-alone based algorithms, on a variety of chemical systems, including molecular clusters and heterogeneous surfaces. In conclusion, our results demonstrate RANGE’s efficiency, robustness, and broad applicability in addressing challenging global optimization problems in computational chemistry and materials science.