Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The Morrison Bearingless Switched Reluctance Motor

Switched reluctance motors typically consist of pairs of poles protruding outward from a central rotor, surrounded by pairs of coils protruding inward from a stator. The pairs of coils, positioned a short distance from opposing sides of the rotor, are connected in series. A current runs through the coils, generating a magnetic flux between the coils. This attracts the protruding poles on the rotor, and just as the poles on the rotor approach the coils, the current to the coils is inverted, repelling the rotor s poles as they pass the coils. This current switching, back and forth, provides a continuous rotational torque to the rotor. reliability, durability, low cost, and operation in adverse environments such as high temperatures, extreme temperature variations, and high rotational speeds. However, because rotors are often manufactured with minute flaws due to imperfections in the machining process, traditional switched reluctance motors often suffer from substantial amounts of vibration. In addition, the current in the coils imparts a strong radial magnetic force on the rotor; the continuous alternating of the direction of this force also causes vibration. As a result, switched reluctance motors require bearings that, run at high speeds, can require lubrication apparatus and are subject to problems with heat and wear. My mentor s recent invention, the "Bearingless" Switched Reluctance Motor, actually uses magnetic bearings instead of traditional physical bearings. Sensors are used to continuously determine the position of the rotor. A computer reads the position sensor input, performs calculations, and outputs a current to a set of extra coils (in addition to the coils rotating the rotor). This current provides a magnetic force that counters and damps the vibration. The sense-calculate-update loop iterates more than thirty thousand times per second. For now, our goal is to have the rotor rotate at about 6000 rprn, and at that speed, the magnetic bearing is adjusting the rotor s position more than 300 times per rotation. and vibration-suppression capacity for the switched reluctance motor. Traditional switched reluctance motors possess many positive traits, including It is hoped that this new invention will increase load-carrying capacity, stiffness, and vibration-suppression capacity for the switched reluctance motor.

Wong, David S.↗

ITER Central Solenoid support structure analysis

The ITER Central Solenoid (CS) is comprised of six independent coils held together by a pre-compression support structure. This structure must provide enough preload to maintain sufficient coil-to-coil contact and interface load throughout the current pulse. End of burn (EOB) represents one of the most extreme time-points doing the reference scenario when the currents in the CS3 coils oppose those of CS1 & CS2. The CS structure is performance limited by the room temperature static yield requirements needed to support the roughly 180 MN preload to resist coil separation during operation. This preload is applied by inner and external tie plates along the length of the coil stack by mechanical fastening methods utilizing Superbolt technology. The preloading structure satisfies the magnet structural design criteria of ITER and will be verified during mockup studies. The solenoid is supported from the bottom of the toroidal field (TF) coil casing in both the vertical radial directions. The upper support of the CS coil structure maintains radial registration with the TF coil in the event of vertical disruptions (VDE) loads and earthquakes. All of these structure systems are analyzed via a global finite element analysis (FEA). The model includes a complete sector of the TF coil and the CS coil/structure in one self-consistent analysis. The corresponding results and design descriptions are described in this report.

42 ENGINEERING↗

Concept Design of Active Shielding for Dynamic Wireless Charging of Light-duty EV

Dynamic wireless charging of electric vehicles is a flexible and state of the art charging technology with the potential capability of enabling fully automated in-motion charging. With charging power increasing to more than 100 kW for light duty vehicles, electromagnetic field (EMF) emission becomes a critical challenge. Due to the high costs of ferrite materials, this paper proposes an active shielding solution with multiple canceling coils installed on the ground side to supplement ferrite passive shielding to ensure electromagnetic safety. Two canceling coils are designed on two sides of the ground side coil. The canceling coils are small in size and 180 degree opposite in phase to the ground coil. Simulation and modeling shows that the canceling coils can reduce EMF emission from 37.2 µT to 18.2 µT at 0.8 m during 100 kW operation with only 2.5% of ground side current flowing in the canceling coils. These results have been preliminarily verified by inductance measurements and magnetic field measurement at 1.1 m distance without canceling coils. By further increasing the canceling coils’ currents to 4%, EMF emission can also be mitigated at 200 kW, although the canceling coils’ shape, position, and phase angle can be further optimized to improve the three-dimensional field distribution.

25 ENERGY STORAGE↗

Electromagnetic propulsion system

An electromagnetic propulsion system comprises a plurality of stator coils wound about a first axis, a plurality of support structures, a coupler that surrounds a portion of the stator coils, and a plurality of rotor coils wound about an axis that is parallel to the first axis. The stator coils are configured to receive electric current to induce a first magnetic field. The support structures support the stator coils. The coupler includes a notch oriented so that one of the support structures can pass through the notch when the coupler moves along the stator coils. The rotor coils are attached to the coupler and are configured to receive electric current to induce a magnetic field that interacts with the first magnetic field so that a magnetic force is applied to the rotor coils, thereby propelling the coupler and the rotor coils along the stator coils.

Hartman, Seth↗

Electromagnetic propulsion system

An electromagnetic propulsion system is provided. The system comprises first and second pluralities of stator coils wound about first and second axes, a plurality of support structures, first and second couplers that surround portions of the first and second pluralities of stator coils, and first and second pluralities of sets of rotor coils wound about axes that are parallel to the first and second axes. The stator coils are configured to receive electric current through an outside controller selecting appropriately coupled stator sections or through a sliding electrical contact system or bearing system to induce at least a first magnetic field. The plurality of support structures supports the first and second plurality of stator coils. The first and second couplers include notches and are oriented so that their notches pass over the plurality of support structures when the couplers move along the stator coils. The couplers may have an adjustable segment to close the notch. The sets of rotor coils are equidistantly attached to the couplers and are configured to receive electric current to induce magnetic fields that interact with the magnetic fields of the stator coils so that magnetic forces are applied to the plurality of rotor coils, thereby propelling the couplers along the stator coils.

Hartman, Seth↗

Electromagnetic propulsion system

An electromagnetic propulsion system is provided. The system comprises first and second pluralities of stator coils wound about first and second axes, a plurality of support structures, first and second couplers that surround portions of the first and second pluralities of stator coils, and first and second pluralities of sets of rotor coils wound about axes that are parallel to the first and second axes. The stator coils are configured to receive electric current through an outside controller selecting appropriately coupled stator sections or through a sliding electrical contact system or bearing system to induce at least a first magnetic field. The plurality of support structures supports the first and second plurality of stator coils. The first and second couplers include notches and are oriented so that their notches pass over the plurality of support structures when the couplers move along the stator coils. The couplers may have an adjustable segment to close the notch. The sets of rotor coils are equidistantly attached to the couplers and are configured to receive electric current to induce magnetic fields that interact with the magnetic fields of the stator coils so that magnetic forces are applied to the plurality of rotor coils, thereby propelling the couplers along the stator coils.

Hartman, Seth↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ARC physics basis–magnetohydrodynamics

ARC is designed to produce 400 ⁢MW of net electricity and prove the commercial feasibility of a fusion power plant. In order to achieve this goal ARC has to operate with optimal core performance in a stationary scenario that minimises wear on the first wall and divertor. This requires avoiding or mitigating magnetohydrodynamic (MHD) instabilities which have the potential to not only degrade the plasma core but also lead to deleterious transient heat loads on plasma facing components. Therefore, this work aims at characterising the MHD stability of the high performance ARC scenario and inform the design of error field correction coils. Firstly, simulations of vertical displacement events show that an in-vessel coil is not needed and instead the poloidal shaping coils can be used to control vertical stability. These simulations also inform the demands on the corresponding coil power supplies. Stability analysis of the ideal kink mode with or without a conducting wall and kinetic effects suggests that the ARC baseline scenario operates deeply in the stable region. Using RDCON, tearing modes at the 𝑚/𝑛 =2/1 and 3/2 surfaces (with poloidal mode number 𝑚, and toroidal mode number 𝑛) are shown to be linearly stable, and including thermal transport effects in the rational surfaces lead to further stabilisation. However, other transient plasma instabilities can seed neoclassical tearing modes (NTMs). The marginally stable width of NTMs in ARC strongly depends on the internal inductance and can fall below 0.1% of the normalised poloidal flux. Furthermore, an empirical cross-machine model of the 𝑛 =1 error field leading to a disruption predicts a critical error field larger than SPARC but smaller than ITER. Three-dimensional coils can be designed with the Generalised Purturbed Equilbium Code based on a simple model that calculates the maximum correctable error field that is limited by the neoclassical toroidal viscosity torque. Broad scans of different coil geometries identify a set of 2 rows of off-midplane coils to be a suitable solution. It is also determined that such a set of three-dimensional coils is capable of correcting 𝑛 =2 error fields to some degree and creating strong enough 𝑛 =2 or 𝑛 =3 edge resonant perturbation fields for the suppression of edge-localised modes at reasonable coil currents. The final design of the first ARC will be further informed by results from SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring Microphase Separation in Semi-Fluorinated Diblock Copolymers: A Combined Experimental and Modeling Investigation

We report the combined experimental and theoretical study of the bulk self-assembly behavior of polystyrene-blockpoly( 2,3,4,5,6-pentafluorostyrene) diblock copolymers. These block copolymers were designed to create highly antagonistic blocks (with a high Flory−Huggins interaction parameter, χ) with minimum disruption to the molecular construct (i.e., only replacing five hydrogen atoms with five fluorine atoms). A large library of diblock copolymers (41 samples) was synthesized by reversible addition− fragmentation chain transfer (RAFT) polymerization to map out a major portion of the phase space. All block copolymers exhibited narrow molecular weight distributions with dispersity (D) values between 1.07 and 1.32, and subsequent thermal annealing revealed phase separation into well-defined nanoscale morphologies depending on their molecular composition, as determined from small-angle X-ray scattering and transmission electron microscopy analyses, with an experimental phase diagram being constructed. The χ value at 25 °C for this block copolymer was estimated to be 0.2 using strong segregation theory, based on trends in phase-separated domain spacing and interfacial width. When applying theoretical approaches, the majority of the domain spacing data trends were captured by a coil−coil diblock copolymer model; however, a better fit to the data for samples with shorter fluorinated blocks was obtained with a rod−coil model, indicating that the chains in these fluorinated blocks likely have a higher inherent stiffness and were thus rod-like. This observation demonstrates that, due to the very high value of χ, a transition from coil−coil to rod−coil behavior can be obtained purely by reducing the length of the stiffer of the two blocks and without varying temperature or the chemical composition of the polymers. Here, this work showcases the presence of strong microphase separation within AB diblock copolymers despite the relatively similar chemical composition of the constituent “A” and “B” units, with a clear transition from rod−coil to coil−coil segregation behavior.

RAFT polymerization↗

Crystal structure of a plectonemic RNA supercoil

Genome packaging is an essential housekeeping process in virtually all organisms for proper storage and maintenance of genetic information. Although the extent and mechanisms of packaging vary, the process involves the formation of nucleic-acid superstructures. Crystal structures of DNA coiled coils indicate that their geometries can vary according to sequence and/or the presence of stabilizers such as proteins or small molecules. However, such superstructures have not been revealed for RNA. Here we report the crystal structure of an RNA supercoil, which displays one level higher molecular organization than previously reported structures of DNA coiled coils. In the presence of an RNA-binding protein, two interlocking RNA coiled coils of double-stranded RNA, a 'coil of coiled coils', form a plectonemic supercoil. Molecular dynamics simulations suggest that protein-RNA interaction is required for the stability of the supercoiled RNA. This study provides structural insight into higher order packaging mechanisms of nucleic acids.

59 BASIC BIOLOGICAL SCIENCES↗

Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrating novel stellarator single-stage optimization algorithms to design the Columbia stellarator experiment

Abstract The Columbia Stellarator eXperiment (CSX), currently being designed at Columbia University, aims to test theoretical predictions related to QA plasma behavior, and to pioneer the construction of an optimized stellarator using three-dimensional, non-insulated high-temperature superconducting (NI-HTS) coils. The magnetic configuration is generated by a combination of two circular planar poloidal field (PF) coils and two 3D-shaped interlinked (IL) coils, with the possibility to add windowpane coils to enhance shaping and experimental flexibility. The PF coils and vacuum vessel are repurposed from the former Columbia Non-Neutral Torus experiment, while the IL coils will be custom-wound in-house using NI-HTS tapes. To obtain a plasma shape that meets the physics objectives with a limited number of coils, novel single-stage optimization techniques are employed, optimizing both the plasma and coils concurrently, in particular targeting a tight aspect ratio QA plasma and minimized strain on the HTS tape. Despite the increased complexity due to the expanded degrees of freedom, these methods successfully identify optimized plasma geometries that can be realized by coils meeting engineering specifications. This paper discusses the derivation of the constraints and objectives specific to CSX, and describe how two recently developed single-stage optimization methodologies are applied to the design of CSX. A set of selected configurations for CSX is then described in detail.

Baillod, A. (ORCID:0000000303529180)↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Satellite Attitude Control Utilizing the Earth's Magnetic Field

A study was conducted to determine the feasibility of a satellite attitude fine-control system using the interaction of the earth's magnetic field with current-carrying coils to produce torque. The approximate intensity of the earth's magnetic field was determined as a function of the satellite coordinates. Components of the magnetic field were found to vary essentially sinusoidally at approximately twice orbital frequency. Amplitude and distortion of the sinusoidal components were a function of satellite orbit. Two systems for two-axis attitude control evolved from this study, one using three coils and the other using two coils. The torques developed by the two systems differ only when the component of magnetic field along the tracking line is zero. For this case the two-coil system develops no torque whereas the three-coil system develops some effective torque which allows partial control. The equations which describe the three-coil system are complex in comparison to those of the two-coil system and require the measurement of all three components of the magnetic field as compared with only one for the two-coil case. Intermittent three-axis torquing can also be achieved. This torquing can be used for coarse attitude control, or for dumping the stored momentum of inertia reaction wheels. Such a system has the advantage of requiring no fuel aboard the satellite. For any of these magnetic torquing schemes the power required to produce the magnetic moment and the weight of the coil seem reasonable.

White, John S.↗

Measurement of Two-Phase Flow Characteristics Under Microgravity Conditions

This paper describes the technical approach and initial results of a test program for studying two-phase annular flow under the simulated microgravity conditions of KC-135 aircraft flights. A helical coil flow channel orientation was utilized in order to circumvent the restrictions normally associated with drop tower or aircraft flight tests with respect to two-phase flow, namely spatial restrictions preventing channel lengths of sufficient size to accurately measure pressure drops. Additionally, the helical coil geometry is of interest in itself, considering that operating in a microgravity environment vastly simplifies the two-phase flows occurring in coiled flow channels under 1-g conditions for virtually any orientation. Pressure drop measurements were made across four stainless steel coil test sections, having a range of inside tube diameters (0.95 to 1.9 cm), coil diameters (25 - 50 cm), and length-to-diameter ratios (380 - 720). High-speed video photographic flow observations were made in the transparent straight sections immediately preceding and following the coil test sections. A transparent coil of tygon tubing of 1.9 cm inside diameter was also used to obtain flow visualization information within the coil itself. Initial test data has been obtained from one set of KC-135 flight tests, along with benchmark ground tests. Preliminary results appear to indicate that accurate pressure drop data is obtainable using a helical coil geometry that may be related to straight channel flow behavior. Also, video photographic results appear to indicate that the observed slug-annular flow regime transitions agree quite reasonably with the Dukler microgravity map.

Keshock, E. G.↗

Laboratory-Model Integrated-System FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster [1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In a previous paper [3], the authors presented a basic design for a 100 J/pulse FARAD laboratory-version thruster. The design was based upon guidelines and performance scaling parameters presented in Refs. [4, 5]. In this paper, we expand upon the design presented in Ref. [3] by presenting a fully-assembled and operational FARAD laboratory-model thruster and addressing system and subsystem-integration issues (concerning mass injection, preionization, and acceleration) that arose during assembly. Experimental data quantifying the operation of this thruster, including detailed internal plasma measurements, are presented by the authors in a companion paper [6]. The thruster operates by first injecting neutral gas over the face of a flat, inductive acceleration coil and at some later time preionizing the gas. Once the gas is preionized current is passed through the acceleration coil, inducing a plasma current sheet in the propellant that is accelerated away from the coil through electromagnetic interaction with the time-varying magnetic field. Neutral gas is injected over the face of the acceleration coil through a fast-acting valve that feeds a central distribution manifold. The thruster is designed to preionize the gas using an RF-frequency ringing signal produced by a discharging Vector Inversion Generator (VIG). The acceleration stage consists of a multiple-turn, multiple-strand spiral induction coil (see Fig. 1, left panel) and is designed for operation at discharge energies on the order of 100 J/pulse. Several different pulsed power train modules can be used to drive current through the acceleration coil. One such power train is based upon the Bernardes and Merryman circuit topology, which restricts voltage reversal on the capacitor banks and can be clamped to eliminate current reversal in the coil. A second option is a pulse-compression-ring power train (see Fig. 1, right panel), which takesa temporally broad, low current pulse and transforms it into a short, high current pulse.

Polzin, K.A.↗

Analysis of NSTX Upgrade OH Magnet and Center Stack

The new ohmic heating (OH) coil and center stack for the National Spherical Torus Experiment (NSTX) upgrade are required to meet cooling and structural requirements for operation at the enhanced 1 Tesla toroidal field and 2 MA plasma current. The OH coil is designed to be cooled in the time between discharges by water flowing in the center of the coil conductor. We performed resistive heating and thermal hydraulic analyses to optimize coolant channel size to keep the coil temperature below 100 C and meet the required 20 minute cooling time. Coupled electromagnetic, thermal and structural FEA analyses were performed to determine if the OH coil meets the requirements of the structural design criteria. Structural response of the OH coil to its self-field and the field from other coils was analyzed. A model was developed to analyze the thermal and electromagnetic interaction of centerstack components such as the OH coil, TF inner legs and the Bellville washer preload mechanism. Torsional loads from the TF interaction with the OH and poloidal fields are transferred through the TF flag extensions via a torque transfer coupling to the rest of the tokamak structure. A 3D FEA analysis was performed to qualify this design. The results of these analyses, which will be presented in this paper, have led to the design of OH coil and centerstack components that meet the requirements of the NSTX-upgrade structural design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accomplishments in Field Period Assembly for NCSX* This is how we did it

The National Compact Stellarator Experiment (NCSX) was a collaborative effort between ORNL and PPPL. PPPL provided the assembly techniques with guidance from ORNL to meet design criteria. The individual vacuum vessel segments, modular coils, trim coils, and toroidal field coils components were delivered to the Field Period Assembly (FPA) crew who then would complete the component assemblies and then assemble the final three field period assemblies, each consisting of two sets of three modular coils assembled over a 120o vacuum vessel segment with the trim coils and toroidal field coils providing the outer layer. The requirements for positioning the modular coils were found to be most demanding. The assembly tolerances required for accurate positioning of the field coil windings in order to generate sufficiently accurate magnetic fields strained state of the art techniques in metrology and alignment and required constant monitoring of assembly steps with laser trackers, measurement arms, and photogrammetry. The FPA activities were being performed concurrently while engineering challenges were being resolved. For example, it was determined that high friction electrically isolated shims were needed between the modular coil interface joints and low distortion welding was required in the nose region of those joints. This took months of analysis and development yet the assembly was not significantly impacted because other assembly tasks could be performed in parallel with ongoing assembly tasks as well as tasks such as advance tooling setup preparation for the eventual welding tasks. The crew technicians developed unique, accurate time saving techniques and tooling which provided significant cost and schedule savings. Project management displayed extraordinary foresight and every opportunity to gain advanced knowledge and develop techniques was taken advantage of. Despite many risk concerns, the cost and schedule performance index was maintained nearly 1.0 during the assembly phase until project cancellation. In this paper, the assembly logic, the engineering challenges, solutions to those challenges and some of the unique and clever assembly techniques, will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗