Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

NEW IMPROVED CALIBRATION RELATIONS FOR THE DETERMINATION OF ELECTRON TEMPERATURES AND OXYGEN AND NITROGEN ABUNDANCES IN H II REGIONS

New improved empirical calibrations for the determination of electron temperatures and oxygen and nitrogen abundances in H II regions from the strong emission lines of oxygen, nitrogen, and sulfur are given. They are derived using spectra of H II regions with measured electron temperatures as calibrating data. Calibration relations are given separately for three classes of H II regions: cool, warm, and hot ones. Criteria for assigning a H II region to one of these classes are suggested. We find that classification ambiguities arise only in the case of hot H II regions with enhanced nitrogen abundances. The derived calibrations provide reliable abundances for H II regions: the mean difference between oxygen abundances determined from the calibrations and T{sub e} -based oxygen abundances is {approx}0.075 dex, while it is {approx}0.05 dex for nitrogen abundances.

79 ASTRONOMY AND ASTROPHYSICS↗

ACCOUNTING FOR CALIBRATION UNCERTAINTIES IN X-RAY ANALYSIS: EFFECTIVE AREAS IN SPECTRAL FITTING

While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here, we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can be applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

CALIBRATING THE STAR FORMATION RATE AT z {approx} 1 FROM OPTICAL DATA

We present a star formation rate (SFR) calibration based on optical data that is consistent with average observed rates in both the red and blue galaxy populations at z {approx} 1. The motivation for this study is to calculate SFRs for DEEP2 Redshift Survey galaxies in the 0.7 < z < 1.4 redshift range, but our results are generally applicable to similar optically selected galaxy samples without requiring UV or IR data. Using SFR fits from UV/optical spectral energy distributions (SEDs) in the All-Wavelength Extended Groth Strip International Survey, we explore the behavior of rest-frame B-band magnitude, observed [O II] luminosity, and rest-frame color with SED-fit SFR for both red sequence and blue cloud galaxies. The resulting SFR calibration is based on three optical-band observables: M{sub B} , (U - B), and (B - V). The best-fit linear relation produces residual errors of 0.3 dex rms scatter for the full color-independent sample with minimal correlated residual error in L[O II] or stellar mass. We then compare the calibrated z {approx} 1 SFRs to two diagnostics that use L[O II] as a tracer in local galaxies and correct for dust extinction at intermediate redshifts through either galaxy B-band luminosity or stellar mass. We find that an L[O II]-M{sub B} SFR calibration commonly used in the literature agrees well with our calculated SFRs after correcting for the average B-band luminosity evolution in L{sub *} galaxies. However, we find better agreement with a local L[O II]-based SFR calibration that includes stellar mass to correct for reddening effects, indicating that stellar mass is a better tracer of dust extinction for all galaxy types and less affected by systematic evolution than galaxy luminosity from z = 1 to the current epoch.

79 ASTRONOMY AND ASTROPHYSICS↗

ADVANCES IN THE RXTE PROPORTIONAL COUNTER ARRAY CALIBRATION: NEARING THE STATISTICAL LIMIT

During its 16 years of service, the Rossi X-Ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observations of variable X-ray sources for fast timing studies. It is, therefore, very important to have the most reliable calibration of RXTE instruments. The Proportional Counter Array (PCA) is the primary instrument on board RXTE which provides data in 3-50 keV energy range with submillisecond time resolution in up to 256 energy channels. In 2009, the RXTE team revised the response residual minimization method used to derive the parameters of the PCA physical model. The procedure is based on the residual minimization between the model spectrum for Crab Nebula emission and a calibration data set consisting of a number of spectra from the Crab and the on-board Am{sub 241} calibration source, uniformly covering the whole RXTE mission operation period. The new method led to a much more effective model convergence and allowed for better understanding of the PCA energy-to-channel relationship. It greatly improved the response matrix performance. We describe the new version of the RXTE/PCA response generator PCARMF v11.7 (HEASOFT Release 6.7) along with the corresponding energy-to-channel conversion table (version e05v04) and their difference from the previous releases of PCA calibration. The new PCA response adequately represents the spectrum of the calibration sources and successfully predicts the energy of the narrow iron emission line in Cas-A throughout the RXTE mission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STUDY OF CALIBRATION OF SOLAR RADIO SPECTROMETERS AND THE QUIET-SUN RADIO EMISSION

This work presents a systematic investigation of the influence of weather conditions on the calibration errors by using Gaussian fitness, least chi-square linear fitness, and wavelet transform to analyze the calibration coefficients from observations of the Chinese Solar Broadband Radio Spectrometers (at frequency bands of 1.0–2.0 GHz, 2.6–3.8 GHz, and 5.2–7.6 GHz) during 1997–2007. We found that calibration coefficients are influenced by the local air temperature. Considering the temperature correction, the calibration error will reduce by about 10%–20% at 2800 MHz. Based on the above investigation and the calibration corrections, we further study the radio emission of the quiet Sun by using an appropriate hybrid model of the quiet-Sun atmosphere. The results indicate that the numerical flux of the hybrid model is much closer to the observation flux than that of other ones.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring infrared surface brightness fluctuation distances with HST WFC3: Calibration and advice

We present new calibrations of the near-infrared (near-IR) surface brightness fluctuation (SBF) distance method for the F110W (J{sub 110}) and F160W (H{sub 160}) bandpasses of the Wide Field Camera 3 Infrared Channel (WFC3/IR) on the Hubble Space Telescope. The calibrations are based on data for 16 early-type galaxies in the Virgo and Fornax clusters observed with WFC3/IR and are provided as functions of both the optical (g{sub 475}−z{sub 850}) and near-infrared (J{sub 110}−H{sub 160}) colors. The scatter about the linear calibration relations for the luminous red galaxies in the sample is approximately 0.10 mag, corresponding to a statistical error of 5% in distance. Our results imply that the distance to any suitably bright elliptical galaxy can be measured with this precision out to about 80 Mpc in a single-orbit observation with WFC3/IR, making this a remarkably powerful instrument for extragalactic distances. The calibration sample also includes much bluer and lower-luminosity galaxies than previously used for IR SBF studies, revealing interesting population differences that cause the calibration scatter to increase for dwarf galaxies. Comparisons with single-burst population models show that as expected, the redder early-type galaxies contain old, metal-rich populations, while the bluer dwarf ellipticals contain a wider range of ages and lower metallicities than their more massive counterparts. Radial SBF gradients reveal that IR color gradients are largely an age effect; the bluer dwarfs typically have their youngest populations near their centers, while the redder giant ellipticals show only weak trends and in the opposite sense. Because of the population variations among bluer galaxies, distance measurements in the near-IR are best limited to red early-type galaxies. We conclude with some practical guidelines for using WFC3/IR to measure reliable SBF distances.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 2 data

This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb -1 of LHC proton-proton collision data recorded at $\sqrt{s}$ = 13 TeV between 2015 and 2018. Methods for the measurement of electron and photon energies are outlined, along with the current knowledge of the passive material in front of the ATLAS electromagnetic calorimeter. The energy calibration steps are discussed in detail, with emphasis on the improvements introduced in this paper. The absolute energy scale is set using a large sample of Z-boson decays into electron-positron pairs, and its residual dependence on the electron energy is used for the first time to further constrain systematic uncertainties. The achieved calibration uncertainties are typically 0.05% for electrons from resonant Z-boson decays, 0.4% at E T ~ 10 GeV, and 0.3% at E T ~ 1 TeV; for photons at E T ~ 60 GeV, they are 0.2% on average. This is more than twice as precise as the previous calibration. The new energy calibration is validated using J/ψ → ee and radiative Z-boson decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE MID-INFRARED TULLY-FISHER RELATION: CALIBRATION OF THE TYPE Ia SUPERNOVA SCALE AND H{sub 0}

This Letter builds on a calibration of the Type Ia supernova (SNIa) absolute distance scale begun with a core of distances based on the correlation between galaxy rotation rates and optical I{sub C} -band photometry. This new work extends the calibration through the use of mid-infrared photometry acquired at 3.6 {mu}m with the Spitzer Space Telescope. The great virtue of the satellite observations is the constancy of the photometry at a level better than 1% across the sky. The new calibration is based on 39 individual galaxies and 8 clusters that have been the sites of well-observed SNIa. The new 3.6 {mu}m calibration is not yet as extensively based as the I{sub C} -band calibration but is already sufficient to justify a preliminary report. Distances based on the mid-infrared photometry are 2% greater in the mean than reported at the I{sub C} band. This difference is only marginally significant. The I{sub C} -band result is confirmed with only a small adjustment. Incorporating a 1% decrease in the Large Magellanic Cloud distance, the present study indicates H{sub 0} = 75.2 {+-} 3.0 km s{sup -1} Mpc{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling study of a proposed field calibration source using K-40 and high-Z targets for sodium iodide detectors

Calibration sources based on the primordial isotope potassium-40 ( 40 K) have reduced controls on the source’s activity due to its terrestrial ubiquity and very low specific activity. Potassium–40’s beta emissions and 1,460.8 keV gamma ray can be used to induce K-shell fluorescence x rays in high-Z metals between 60 and 80 keV. A gamma ray calibration source that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument is thus proposed. The calibration source was designed in collaboration with the Sandia National Laboratory using the Monte Carlo N-Particle eXtended (MCNPX) transport code. Two methods of x-ray production were explored. First, a thin high-Z layer (HZL) was interposed between the detector and the potassium chloride-urethane source matrix. Second, bismuth metal powder was homogeneously mixed with a urethane binding agent to form a potassium chloride-bismuth matrix (KBM). The bismuth-based source was selected as the development model because it is inexpensive, nontoxic, and outperforms the high-Z layer method in simulation. As a result, based on the MCNPX studies, sealing a mixture of bismuth powder and potassium chloride into a thin plastic case could provide a light, inexpensive field calibration source.

40K↗

Investigation of workplace-like calibration fields via a deuterium-tritium (D-T) neutron generator

Radiation survey meters and personal dosimeters are typically calibrated in reference neutron fields based on conventional radionuclide sources, such as Americium Beryllium (AmBe) or Californium-252 (252Cf), either unmodified or heavy-water moderated. However, these calibration neutron fields differ significantly from the workplace fields in which most of these survey meters and dosimeters are being used. Although some detectors are designed to yield an approximately dose-equivalent response over a particular neutron energy range, the response of other detectors is highly dependent upon neutron energy. This, in turn, can result in significant over- or underestimation of the intensity of neutron radiation and/or personal dose equivalent determined in the work environment. The use of simulated workplace neutron calibration fields that more closely match those present at the workplace could improve the accuracy of worker, and workplace, neutron dose assessment. This work provides an overview of the neutron fields found around nuclear power reactors and interim spent fuel storage installations based on available data. The feasibility of producing, in an existing calibration facility, workplace-like calibration fields has been investigated via Monte Carlo simulations. Several moderating assembly configurations, paired with a neutron generator using the deuterium tritium (D-T) fusion reaction, were explored

D–T Generator, neutron calibration, workplace neut↗

Optimal calibration accuracy for gravitational-wave detectors

Calibration errors in the response function of a gravitational-wave detector degrade its ability to detect and then to measure the properties of any detected signals. This paper derives the needed levels of calibration accuracy for each of these data-analysis tasks. The levels derived here are optimal in the sense that lower accuracy would result in missed detections and/or a loss of measurement precision, while higher accuracy would be made irrelevant by the intrinsic noise level of the detector. Calibration errors affect the data-analysis process in much the same way as errors in theoretical waveform templates. The optimal level of calibration accuracy is expressed therefore as a joint limit on modeling and calibration errors: increased accuracy in one reduces the accuracy requirement in the other.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIST Standard Reference Material 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering

The certification of a new standard reference material for small-angle scattering [NIST Standard Reference Material (SRM) 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering (SAXS)], based on glassy carbon, is presented. Creation of this SRM relies on the intrinsic primary calibration capabilities of the ultra-small-angle X-ray scattering technique. This article describes how the intensity calibration has been achieved and validated in the certified Q range, Q = 0.008–0.25 Å –1 , together with the purpose, use and availability of the SRM. The intensity calibration afforded by this robust and stable SRM should be applicable universally to all SAXS instruments that employ a transmission measurement geometry, working with a wide range of X-ray energies or wavelengths. As a result, the validation of the SRM SAXS intensity calibration using small-angle neutron scattering (SANS) is discussed, together with the prospects for including SANS in a future renewal certification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-Reference Procedure to Reduce Uncertainty in Module Calibration

This paper presents a composite measurement approach that capitalizes on complimentary strengths of 3 different test beds to significantly reduce uncertainty in I-V parameters for secondary module calibration. This approach addresses PV manufacturers' need for reduced uncertainty in the calibration modules that provide the basis for their module power ratings. This new method enables NREL to reduce uncertainty for secondary module calibration in commercial c-Si modules from +/-3.2% to +/-0.7% for I SC and from +/-3.3% to +/-1.1% for P MAX . This new module self-reference, or MSR procedure is based on the sensitivity of module voltage to temperature plus the uniformity of outdoor sunlight. By calibrating module V OC in thermal equilibrium on a flash simulator we provide an accurate gauge of junction temperature for subsequent measurements. By calibrating I SC outdoors in natural sunlight we enable the module to serve as its own reference device in setting the intensity of a continuous simulator, effectively eliminating the impact of spatial non-uniformity and spectral mismatch on the I-V measurement. These procedures significantly reduce measurement errors due to temperature uncertainty, spatial non-uniformity, and spectral mismatch.

14 SOLAR ENERGY↗

Calibration of 2-D soil zymography for correct analysis of enzyme distribution

Soil zymography is a new technique developed to visualize two-dimensional distributions of enzyme activities. The method is composed of incubating a membrane saturated with an enzyme-specific fluorogenic substrate on a surface of the soil sample, followed by recording the membrane image generated by a fluorescent product (e.g. MUF: methylumbelliferone) in ultraviolet light. Despite its relative ease of use, performing zymography involves multiple user-made decisions that might affect the accuracy of enzyme activity estimates. Thus, unification of the zymography methodology is required for correct estimations and comparisons of various studies. We investigated the following methodological aspects of the implementation of zymography: (a) camera settings and image processing, (b) effects of evaporation and (c) calibration procedures. Camera settings (shutter speeds or exposure time) affected the intensity of background fluorescence and signal-to-noise ratios (SNR). However, because their combined effects varied depending on MUF concentrations, light and camera setting need to be optimized for the expected range of MUF concentrations prior to zymography. Evaporation of MUF solution from the membrane had no effect on fluorescence. Relations between MUF concentration and intensity of fluorescence during calibrations demonstrated a saturated pattern and were strongly affected by image noise outside the optimal range (e.g. 8–14 μm MUF pixel -1 ). We developed a new calibration approach that is based on a piecewise linear regression. The new approach accounted for specific ranges of MUF concentration and uses nonuniformly saturated membranes, reflecting the real distribution of enzyme activities in soil. The new calibration algorithm eliminated biases of the standard calibration and resulted in greater accuracy in predicting MUF concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

Estimating Material Properties Under Extreme Conditions by Using Bayesian Model Calibration with Functional Outputs

Summary Dynamic material properties experiments provide access to the most extreme temperatures and pressures attainable in a laboratory setting; the data from these experiments are often used to improve our understanding of material models at these extreme conditions. We apply Bayesian model calibration to dynamic material property applications where the experimental output is a function: velocity over time. This framework can accommodate more uncertainties and facilitate analysis of new types of experiments relative to techniques traditionally used to analyse dynamic material experiments. However, implementation of Bayesian model calibration requires more sophisticated statistical techniques, because of the functional nature of the output as well as parameter and model discrepancy identifiability. We propose a novel Bayesian model calibration process to simplify and improve the estimation of the material property calibration parameters. Specifically, we propose scaling the likelihood function by an effective sample size rather than modelling the auto-correlation function to accommodate the functional output. Additionally, we propose sensitivity analyses by using the notion of 'modularization' to assess the effect of experiment-specific nuisance input parameters on estimates of the physical parameters. The Bayesian model calibration framework proposed is applied to dynamic compression of tantalum to extreme pressures, and we conclude that the procedure results in simple, fast and valid inferences on the material properties for tantalum.

36 MATERIALS SCIENCE↗