Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Circulating Current Resonant Oscillation in Modular Multilevel Converters for Variable Frequency Operation and Its Suppression Method

This paper studies the phenomenon of resonant oscillation in Modular Multilevel Converters (MMCs) for variable frequency operation. Without proper control, it may easily induce huge MMC inner circulating currents and damage major power devices. A Laplace model is established to clarify the mechanism of resonant oscillation in MMCs, and Bode diagrams are used to study the frequency response over a wide frequency range. Meanwhile, a straightforward resonant suppression method based on circulating current control is used to damp out the resonant condition, and a cross comparison is conducted in terms of system losses, capacitor voltage ripples, and load voltage harmonics with and without the resonant oscillation. Both simulation and experimental results are provided to validate the MMC resonant oscillation theory and its suppression control method.

Modular multilevel converter, resonant oscillation↗

A Novel Discharging Control Strategy for Modular Multilevel Converter Submodules without Using External Circuit

A novel discharging control strategy is proposed and implemented for submodules in modular multilevel converters (MMCs). By sequentially controlling the arm currents of a MMC to the arm resistors, all submodule capacitors are discharged safely and rapidly without adding additional devices and circuits, resulting in improved performance and reduced cost. Both open- and closed-loop control methods are evaluated for effectiveness of the new control strategy. Simulation and experimental results are provided to validate the new control strategy.

Modular multilevel converter, discharging method, ↗

Investigation and Compensation of Circulating Current Errors in Low Frequency Operation of Modular Multilevel Converters

The errors between the reference and actual injected circulating currents are investigated for modular multilevel converters (MMCs) in low frequency operation. These errors cause low frequency oscillatory power components in the MMC arms and large voltage fluctuations in the submodule capacitors. By adjusting the circulating current reference with a single parameter, it is possible to compensate the errors and suppress the undesired voltage fluctuations. Computer simulations and experimental results are provided to verify the theoretical derivations.

modular multilevel converter, low frequency operat↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs - including hardware, balance of system, and maintenance costs - and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200 kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.01% efficiency, and an LCOE reduction of 2.0%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

Circulating Current Suppressing Control’s Impact on Arm Inductance Selection for Modular Multilevel Converter

Arm inductor in a modular multilevel converter (MMC) is used to limit the circulating current and dc short circuit fault current. The circulating current in MMC is dominated by second-order harmonic, which can be largely reduced with circulating current suppressing control. By analyzing the mechanism of the circulating current suppressing control, it is found that the circulating current at switching frequency becomes the main harmonic when suppression control is implemented. Unlike the second-order harmonic that circulates only within the three phases, switching frequency harmonic also flows through the dc side and may further cause high-frequency dc voltage harmonic. This article develops the theoretical relationship between the arm inductance and switching frequency circulating current, which can be used to guide the arm inductance selection. The experimental results with a downscaled MMC prototype verify the existence of the switching frequency circulating current and its relationship with arm inductance.

30 DIRECT ENERGY CONVERSION↗

A Phase-Disposition PWM Enabled Model Predictive Control for a Nine-Level Inner-Interleaved Hybrid Multilevel Converter

This article brings forward a phase-disposition pulse width modulation enabled model predictive control (PDPWM-MPC) for a nine-level inner-interleaved hybrid multilevel converter (9L-IHMC). Firstly, three layers of virtual space vector diagrams (VSVD) are established based on the sign patterns of the original and virtual reference vectors in the abcframe, respectively, to achieve the phase-disposition pulse width modulation (PD-PWM) in a non-independent three-phase way. Then, three adjacent virtual vectors in the third-layer VSVD, together with their optimized duty cycles, are applied to guarantee the optimal current tracking. Finally, through the use of the duty cycle alternation approach, dc-link and floating capacitors voltages are balanced and circulating currents are mitigated as well. The proposed PDPWM-MPC can not only enable the decoupling of the low-and high-frequency stages in the 9L-IHMC, but also reduce both output current ripples and computational burden. In addition, it can achieve a constant equivalent switching frequency and address the disproportion of power losses associated with the PD-PWM. Here, both simulations and experiments on a silicon carbide device-based prototype substantiate the effectiveness of the proposed control strategy.

42 ENGINEERING↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave Energy Converter Power Take-Off Modeling and Validation From Experimental Bench Tests

This article describes the implementation of a new numerical model of the power take-off system installed in the Monterey Bay Aquarium Research Institute wave energy converter, a device developed to provide power to various oceanic research missions. The simultaneous presence of hydraulic, pneumatic, and electrical subsystems in the power take-off system represents a significant challenge in forging an accurate model able to replicate the main dynamic characteristics of the system. The validation of the new numerical model is addressed by comparing simulations with the measurements obtained during a series of bench tests. Data from the bench tests show good agreement with the numerical model. The validated model provides deeper insights into the complex nonlinear dynamics of the power take-off system and will support further performance improvements in the future.

16 TIDAL AND WAVE POWER↗

Operando Temperature Measurements of Photovoltaic Laser Power Converter Devices Under Continuous High-Intensity Illumination

Photovoltaic devices that operate under extremely high irradiances, such as laser power converters (LPCs), may also operate at elevated temperatures, even under active cooling, as the result of large temperature gradients. We demonstrate the operation of GaAs LPC devices under orders of magnitude of irradiances up to 150 W/cm 2 in a monochromatic laser simulator with an active cooling stage. The steady-state open-circuit voltage (V OC ) as a function of irradiance is known to droop at high irradiance as the result of junction heating, but the junction temperature can be difficult to measure by conventional methods. Fast, transient V OC measurements under these extreme operating conditions are used here to determine the junction temperature. Empirical V OC temperature coefficients of the devices at each irradiance of interest are determined and used as an integral part of this technique. We show that the thermal design of different LPC devices strongly affects the operating temperature of the junctions. Knowledge of the operating temperature can be a strong tool for understanding the nature of loss mechanisms and improving the design for the operation of photovoltaic LPCs at high irradiances. Furthermore, this technique can be used for laboratory devices during initial design as well as to characterize mass-produced and packaged devices for quality control.

14 SOLAR ENERGY↗

Time Sequence Machine Learning-Based Data Intrusion Detection for Smart Voltage Source Converter-Enabled Power Grid

Smart inverters of distributed energy resources can enable cloud computing, condition monitoring, result visualization, remote control, and peer-to-peer energy trading in advanced power systems. However, the advent of data injection attacks in the communication architecture can alter measurement characteristics of power grids and have devastating consequences. In this article, we propose a time sequence machine learning-based anomaly detection methodology for detecting cyber intrusion into control signal setpoints and dc voltage signal measurement bias of the voltage source converter (VSC) in wind generators. We first investigated the effects of four types of denial of service, tampering signal, and stealthy-type data intrusion attacks on smart VSCs and overall wind farms. We then proposed a novel time sequence machine learning-based intrusion detection framework that can be implemented to detect different cyberattacks in the VSCs. The performance of the proposed framework has been compared with that of autoencoder and clustering-based intrusion detection framework. The proposed framework was validated by using the IEEE 39 bus power system in the presence of four wind farms in different locations. Using several metrics for intrusion detection performance, we validated the effectiveness of the proposed framework.

42 ENGINEERING↗

Economic Comparison Between Battery and Supercapacitor for Hourly Dispatching Wave Energy Converter Power

This paper demonstrates a dispatching scheme of slider-crank wave energy converter (WEC) power generation using two different kinds of energy storage components, namely, Lithium-ion (Li-ion) battery and Supercapacitors (SC). The performance of the two energy storage components has been compared in order to develop the most economical energy storage system for WEC hourly dispatching scheme. The cost optimization of the energy storage system considering both cycling and calendar aging expenses is made based on its usage of depth of discharge. In this study, extensive simulation is conducted in MATLAB/Simulink platform, and it is found that SC is a better solution than Li-ion battery in terms of economic assessment for hourly dispatching WEC power.

50 EE - Wind and Water Power Program - Water (EE-4↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging—Power Die, Power Module, and Converter Level: Part 2

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. Here, to increase power density, performance, efficiency, and reliability-as well as to reduce cost-innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental R&D related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics, packaging materials, thermal materials and interfaces, fluid-based thermal management technologies, reliability, condition monitoring, and prognostics. Latest developments in this area are published as a Special Section on Multiphysics Aspects of Power Electronics Packaging. The first part was published in the May 2024 issue of the IEEE Transactions on Components, Packaging and Manufacturing Technology (Volume 14, Issue 5). The second part of that Special Section is being published in this issue. A brief summary of the papers included in the second part are given below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comments on Control of Wave Energy Converters

The main objective of this letter is to consolidate the knowledge about the dynamics and control of oscillating-body wave energy converters (WECs). A number of studies have shown that control systems strongly affect power absorption; however, there remains a need for a concise and integrated explanation of the theoretical and practical implications that control can have on both performance and the broader WEC design process. This short letter attempts to fill this gap by presenting a discussion on the key practical aspects concerning the dynamics and control of oscillating-body WEC. In particular, the focus is on the choice of control models and a simple causal control scheme suitable for real-time implementation. To conclude, consideration is given to the effect of the power takeoff (PTO) on the maximization of electrical power, thus leading to the derivation of useful conditions for the control co-design of the PTO system.

42 ENGINEERING↗

Design Principles for Resonant Wave Energy Converters: Benchmarking Power Capture and Flow

Control co-design (CCD) in Wave Energy Converters (WECs) integrates the controller, power take-off (PTO), and buoy models during system design to optimize power output. Using the bi-conjugate impedance matching principle, this study models the PTO as a two-port network, revealing impedance matching conditions at the input and output ports as a function of the buoy, PTO, and controller. Here, this study examines the pairing of a flywheel-type pitch resonator PTO within a given buoy constrained by limited space and ballast capacity. The results show that physical constraints imposed by the buoy affect PTO performance. While controller tuning achieves optimal output impedance matching and flywheel inertia is maximized within the buoy's limitations, the PTO's input impedance remains smaller than the complex conjugate of the buoy's intrinsic impedance. This mismatch limits the PTO's ability to generate sufficient reaction torque, particularly outside the resonance frequency, resulting in narrow-band power transfer. The findings emphasize the need for PTO design modifications to improve input power transfer. Pendulum-based PTO mechanisms are proposed as alternatives to couple with multiple buoy motion modes and improve wave-to-wire efficiency while respecting system constraints.

Control Co-Design↗

Converter-Based Emulation of Battery Energy Storage Systems (BESS) for Grid Applications

Battery energy storage systems (BESSs) tend to be too costly, restrictive, and require high maintenance for experimental use, but power system tests often need their representation. As a solution, we propose an all-in-one, reconfigurable BESS emulation tool for grid applications that only requires one three-phase voltage-source converter. This emulator provides chemistry-specific battery behavior like previous work, but it also includes the BESS's power electronics interface and control as well as automatic frequency and voltage support functions for the attached power system. Thus, it allows simple, plug-and-play BESS emulation for grid applications. Here, this paper details the construction, verification, and use of the BESS emulator in an existing grid testbed and concludes that it provides an inexpensive, easy-to-use alternative to using real BESSs in power system experiments.

25 ENERGY STORAGE↗

Zero-Cost Closed-Loop Discharging Method for Modular Multilevel Converter Submodules Without External Circuits

A novel submodule capacitor discharging control strategy is introduced and implemented for modular multilevel converters (MMCs). By sequentially controlling the arm currents of anMMC,all submodule capacitors are discharged rapidly through internal arm resistors without additional devices and circuits, resulting in improved performance and reduced cost. A closed-loop control method is explored for the effectiveness of the new control strategy.Acomparison study is evaluated between the proposed method and the traditional methods using bleeding resistors, auxiliary resistors, and load resistors. Confirmed by the simulation and experiment, the proposed method has the maximum benefits including zero hardware cost, fast discharging time, and negligible load current impact

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗