Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A compact surface decontamination system for surface-sensitive magnetic imaging

A surface decontamination system for application in surface sensitive magnetic imaging tools, such as a spin-polarized scanning electron microscope, is described. Adsorbed contaminant is chemically decomposed with the use of active oxygen in a compact vacuum chamber mounted in a microscope. The present method is especially suitable for fragile magnetic surfaces of complex oxide materials to which the conventional physical etching widely used for magnetic metals could cause serious structural damage. We have succeeded in detecting magnetic signals from a decontaminated oxide surface and visualizing domain images with sufficient magnetic contrast to analyze detailed domain structures.

36 MATERIALS SCIENCE↗

Laser-driven electron beam acceleration and future application to compact light sources

Laser-driven plasma accelerators are gaining much attention by the advanced accelerator community due to the potential these accelerators hold in miniaturizing future high-energy and medium-energy machines. In the laser wakefield accelerator (LWFA), the ponderomotive force of an ultrashort high intensity laser pulse excites a longitudinal plasma wave or bubble. Due to huge charge separation, electric fields created in the plasma bubble can be several orders of magnitude higher than those available in conventional microwave and RF-based accelerator facilities which are limited (up to approx100 MV/m) by material breakdown. Therefore, if an electron bunch is injected into the bubble in phase with its field, it will gain relativistic energies within an extremely short distance. Here, in the LWFA we show the generation of high-quality and high-energy electron beams up to the GeV-class within a few millimeters of gas-jet plasmas irradiated by tens of terawatt ultrashort laser pulses. Thus we realize approximately four orders of magnitude acceleration gradients higher than available by conventional technology. As a practical application of the stable high-energy electron beam generation, we are planning on injecting the electron beams into a few-meters long conventional undulator in order to realize compact X-ray synchrotron (immediate) and FEL (future) light sources. Stable laser-driven electron beam and radiation devices will surely open a new era in science, medicine and technology and will benefit a larger number of users in those fields.

43 PARTICLE ACCELERATORS↗

A compact molecular beam machine

We have developed a compact, low cost, modular, crossed molecular beam machine. The new apparatus utilizes several technological advancements in molecular beams valves, ion detection, and vacuum pumping to reduce the size, cost, and complexity of a molecular beam apparatus. We apply these simplifications to construct a linear molecular beam machine as well as a crossed-atomic and molecular beam machine. The new apparatus measures almost 50 cm in length, with a total laboratory footprint less than 0.25 m{sup 2} for the crossed-atomic and molecular beam machine. We demonstrate the performance of the apparatus by measuring the rotational temperature of nitric oxide from three common molecular beam valves and by observing collisional energy transfer in nitric oxide from a collision with argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation of stable Alfven eigenmodes by application of alternating magnetic field perturbations in the Compact Helical System

Stable toroidicity-induced Alfven eigenmodes (TAEs) with low toroidal mode number (n=1 and n=2) were excited by application of alternating magnetic field perturbations generated with a set of electrodes inserted into the edge region of neutral beam injection heated plasmas on the Compact Helical System [K. Nishimura, K. Matsuoka, M. Fujiwara et al., Fusion Technol. 17, 86 (1990)]. The gap locations of TAEs excited by the electrodes are in the plasma peripheral region of {rho}>0.7 ({rho} is the normalized minor radius) where energetic ion drive is negligibly small, while some AEs are excited by energetic ions in the plasma core region of {rho}<0.4. The damping rate of these stable TAEs derived from plasma responses to applied perturbations is fairly large, that is, {approx}9% to {approx}12% of the angular eigenfrequency. This large damping rate is thought to be dominantly caused by continuum damping and radiative damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact shell solitons in K field theories

Some models providing shell-shaped static solutions with compact support (compactons) in 3+1 and 4+1 dimensions are introduced, and the corresponding exact solutions are calculated analytically. These solutions turn out to be topological solitons and may be classified as maps S{sup 3}{yields}S{sup 3} and suspended Hopf maps, respectively. The Lagrangian of these models is given by a scalar field with a nonstandard kinetic term (K field) coupled to a pure Skyrme term restricted to S{sup 2}, rised to the appropriate power to avoid the Derrick scaling argument. Further, the existence of infinitely many exact shell solitons is explained using the generalized integrability approach. Finally, similar models allowing for nontopological compactons of the ball type in 3+1 dimensions are briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tandem-based compact dual-energy gamma generator

A dual-energy tandem-type gamma generator has been developed at E. O. Lawrence Berkeley National Laboratory and Sandia National Laboratories. The tandem accelerator geometry allows higher energy nuclear reactions to be reached, thereby allowing more flexible generation of MeV-energy gammas for active interrogation applications. Both positively charged ions and atoms of hydrogen are created from negative ions via a gas stripper. In this paper, we show first results of the working tandem-based gamma generator and that a gas stripper can be utilized in a compact source design. Preliminary results of monoenergetic gamma production are shown.

43 PARTICLE ACCELERATORS↗

Electron density measurements of a field-reversed configuration plasma using a novel compact ultrastable second-harmonic interferometer

A compact high-sensitivity second-harmonic interferometer for line-integrated electron density measurements on a large plasma machine is presented. The device is based on a fiber coupled near-infrared continuous-wave Nd:YAG laser and is remotely controlled. The performances of the instrument are tested on the Irvine field-reversed configuration machine, and a sensitivity of few 10{sup 14} cm{sup -2} in measuring line integrated electron density is demonstrated with a time resolution of a few microseconds. The interferometer is self calibrated, has an impressive stability, and it does not require any further alignment after proper installation. These features make this device a real turn-key system suitable for electron density measurement in large plasma machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose Compact Spectrometric Unit

A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage, Real Time Clock and several voltage regulators providing the power for user peripherals (e.g. amplifier, temperature sensors, etc.). Spectrometer is connected with a notebook via high-speed USB 2.0 bus. The spectrometer is multipurpose device, which is planned to be used for measurements of Rn activities, energy of detected particles by CdTe pixel detector or for coincidence measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a compact, permanent magnet electron cyclotron resonance ion source for proton and H{sub 2}{sup +} beam production

A 2.45 GHz microwave ion source was developed at China Institute of Atomic Energy (CIAE) for proton beam production of over 60 mA [B.-Q. Cui, Y.-W. Bao, L.-Q. Li, W.-S. Jiang, and R.-W. Wang, Proceedings of the High Current Electron Cyclotron Resonance (ECR) Ion Source for Proton Accelerator, APAC-2001, 2001 (unpublished)]. For various proton beam applications, another 2.45 GHz microwave ion source with a compact structure is designed and will be built at CIAE as well for high current proton beam production. It is also considered to be used for the test of H{sub 2}{sup +} beam, which could be injected into the central region model cyclotron at CIAE, and accelerated to 5 MeV before extraction by stripping. The required ECR magnetic field is supplied by all the permanent magnets rather than electrical solenoids and six poles. The magnetic field distribution provided by this permanent magnets configuration is a large and uniformly volume of ECR zone, with central magnetic field of a magnitude of {approx}875 Gs[T. Taylor and J. S. C. Wills, Nucl. Instrum. Methods Phys. Res. A 309, 37 (1991)]. The field adjustment at the extraction end can be implemented by moving the position of the magnet blocks. The results of plasma, coupling with 2.45 GHz microwave in the ECR zone inside the ion source are simulated by particle-in-cell code to optimize the density by adjusting the magnetic field distribution. The design configuration of the ion source will be summarized in the paper.

43 PARTICLE ACCELERATORS↗

A compact multipurpose nanomanipulator for use inside a scanning electron microscope

A compact, two-stage nanomanipulator was designed and built for use inside a scanning electron microscope. It consists of a fine stage employing piezostacks that provide a 15 {mu}m range in three dimensions and a coarse stage based on commercially available stick-slip motors. Besides the fabrication of enhanced probes for scanning probe microscopy and the enhancement of electron field emitters, other novel manipulation processes were developed, such as locating, picking up, and positioning small nanostructures with an accuracy of {approx}10 nm. In combination with in situ I-V experiments, welding, and etching, this results in a multipurpose nanofactory, enabling a new range of experiments.

36 MATERIALS SCIENCE↗

The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University

A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; meanwhile this prototype produced over 1 e mA of C{sup 4+} using C{sub 2}H{sub 2} gas (660 W and 40 kV). The beam intensity of C{sup 4+} was 600 e {mu}A with CH{sub 4} gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e {mu}A.

43 PARTICLE ACCELERATORS↗

A compact and continuously driven supersonic plasma and neutral source

A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact stellar objects under the influence of strong magnetic fields

In the present work we study the properties of compact objects under the influence of strong magnetic fields. We consider a gas of nucleons, electrons and muons with beta equilibrium under the influence of different values of magnetic fields, with and without anomalous magnetic moment. Equations of state and mass-radius relations are calculated for different values of the magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Perveance and ion bunch structure from a 'compact, high-pressure' laser ion source

The Dublin City University (DCU) laser ion source (LIS) is a 'compact high-pressure' laser ion source utilizing a table top Q-switched laser. The DCU-LIS combines high laser fluence (F>4 kJ cm{sup -2}), high laser intensity (I>10{sup 11} W cm{sup -2}) with a short field free region (L=48 mm) and high source potential (V{sub ext}>40 kV) in order to offset recombination losses within the plasma and maximize the proportion of highly charged ions which are extracted from the plasma plume. Such a configuration also provides high peak currents (I{sub p}>3 mA), high current densities (J>5 mA cm{sup -2}), and high charge states (Cu{sup 6+}) in the extracted ion-bunch train. However, to obtain and utilize these parameter values in a high pressure LIS requires characterization and control of a number of processes related to ion dynamics and space charge effects on the extracted ions at the plasma plume-anode-extraction gap interface. Relevant issues include electric field distortion, Debye shielding, beam divergence, overfocusing, and perveance (P) in addition to current density profiles for the extracted ion beam. In this paper we focus on these issues and their impact on charge particle extraction and acceleration with a view to elucidating the parameter regimes within which the DCU-LIS performance envelope is optimal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Compact Ion Source with a Hot Hollow Cathode

A compact ion source with 14 mm diameter, 30 mm long discharge region was developed. A total size of the ion source including the beam extraction system was 60 mm in diameter and 160 mm in length. A high temperature coaxial cathode consisting of thin-wall tantalum and tungsten tubes produced a discharge plasma. A source gas was supplied through the inner W tube of the coaxial cathode. A stable plasma of H{sub 2} was maintained with the discharge current of 2.0 A at 68 A cathode heating current. The optimum H{sub 2} gas pressure for ion beam extraction was 2x10{sup -2} Pa. Hydrogen ion beam current was 120 {mu}A (1 mA/cm{sup 2}) at 2.0 A discharge current and 3.0 kV extraction voltage.

43 PARTICLE ACCELERATORS↗

Compact formulas for guiding-center orbits in axisymmetric tokamak geometry

Compact formulas for trapped-particle and passing-particle guiding-center orbits in axisymmetric tokamak geometry are given in terms of the Jacobi elliptic functions and complete elliptic integrals. These formulas can find applications in bounce-center kinetic theory as well as guiding-center Fokker-Planck kinetic theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗