Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Digital array scanned interferometers for astronomy

Investigations are reported of digital array scanned interferometers (DASI) with silicon CCD array detectors to define the operational capabilities of a mapping (polarimetric) spectrometer for astronomical applications based on these instruments. For spectral mapping, spatially resolved spectra using a cylindrical lens to image in the interferometers's redundant coordinate are given. The signal-to-noise characteristics of the Fourier transformed data are demonstrated with regard to the effects of a rectangular sampling function, spectral multiplexing and the pixel-to-pixel variation of the CCD array. These data indicate that DASIs can offer simple, versatile (polarization) mapping spectrometers suitable for spectral mapping observations from the ultraviolet to the infrared of extended sources at variable spatial resolution, particularly where long term stable operation is essential, as for spacecraft instruments.

Smith, Wm. Hayden↗

A new candidate orbital period for KO Velorum (E1013-477)

CCD photometry of KO Vel obtained on five nights in April 1987 is reported. From this and the two previously published sets of CCD photometry, a new candidate orbital period of 0.422 d (10.12 h) is derived. The shape of the folded light curve is nonsinusoidal, which has made the Fourier transform method less effective than usual. It is shown that all three sets of light curves examined here are consistent with the proposed period. All three data sets for the presence of a shorter period are examined, and no conclusive evidence for a periodic variation on an approximately 1 hr time scale is found. The nature of KO Vel therefore still remains an open question.

Mukai, K.↗

Pluto-Charon stellar occultation candidates - 1990-1995

A search to identify stars that might be occulted by Pluto or Charon during the period 1990-1995 and part of 1996 is studied. This search was made with an unfiltered CCD camera operated in the strip scanning mode, and it reaches an R magnitude of approximately 17.5 - about 1.5 mag fainter than previous searches. Circumstances for each of the 162 potential occultations are given, including an approximate R magnitude of the star, which allows estimation of the signal-to-noise ratio (S/N) for observation of each occultation. The faintest stars in the list would yield an S/N of about 20 for a 1 s integration when observed with a CCD detector on an 8 m telescope under a dark sky. The astrometric precision (+/- 0.2 arcsec, with larger systematic errors possible for individual cases) is insufficient to serve as a final prediction for these potential occultations, but is sufficient to identify stars deserving of further, more accurate, astrometric observations. Statistically, about 32 of these events to be observable somewhere on earth are expected. The number of events actually observed will be substantially smaller because of clouds and the sparse distribution of large telescopes. Finder charts for each of the 91 stars involved are presented.

Dunham, E. W.↗

Eliminating Bias In Acousto-Optical Spectrum Analysis

Scheme for digital processing of video signals in acousto-optical spectrum analyzer provides real-time correction for signal-dependent spectral bias. Spectrum analyzer described in "Two-Dimensional Acousto-Optical Spectrum Analyzer" (NPO-18092), related apparatus described in "Three-Dimensional Acousto-Optical Spectrum Analyzer" (NPO-18122). Essence of correction is to average over digitized outputs of pixels in each CCD row and to subtract this from the digitized output of each pixel in row. Signal processed electro-optically with reference-function signals to form two-dimensional spectral image in CCD camera.

Ansari, Homayoon↗

Planetary Spectroscopy

The effort is divided into instrumentation and observational research. In the area of instrumentation, the primary objective is the maintenance and slow improvement of the CCD camera and data acquisition system for continuing use of any interested LPL user. The main goal of the observational research is CCD spectroscopic and imaging studies of the solar system in support of spacecraft investigations. The studies include the physical behavior of comets, the atmospheres of the gaseous planets, and the solid surfaces of satellites and asteroids.

Fink, Uwe↗

Groundbased cometary studies

The physical properties of comets were studied by applying a wide variety of observational techniques. Emphasis is on simultaneous or coordinated observations in different spectral regions (e.g., visible and thermal IR or visible and far UV) or with different instrumentation (imaging, spectroscopy, and photometry). The aim was to: (1) measure the basic properties of cometary nuclei by studying comets whose comae are so anemic that the signal from the nucleus can be extracted; (2) investigate the group characteristics of comets by narrowband photometry applied uniformly to a large sample of comets; (3) understand the detailed physics and chemistry occurring in cometary comae through wide-field charge coupled device (CCD) imaging using narrow filters and through long-slit CCD spectroscopy; and (4) investigate the rotational states of comets through time-resolution photometry.

Schleicher, David G.↗

Storm on Saturn

In September 1990, a white spot appeared on Saturn's atmosphere, which later spread over the entire equatorial region. The accompanying images were obtained as part of an effort to refine techniques for obtaining high resolution groundbased charge coupled device (CCD) images of the planets, and show the turbulent disturbance in Saturn's atmosphere. These broad red-band CCD images were obtained in November 1990 with the Catalina 1.5 m telescope. The planet was low in the sky at sunset, but the viewing was good enough to show detail in the equatorial region over all longitudes. Visibility of the features is enhanced by digital spatial filtering techniques. A storm of this magnitude has not been seen on Saturn since 1933.

Larson, Stephen M.↗

Model-based frequency response characterization of a digital-image analysis system for epifluorescence microscopy

Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.

Hazra, Rajeeb↗

SHAPES - Spatial, high-accuracy, position-encoding sensor

Future space systems will require control sensors capable of real-time measurements of position coordinates of many structural locations. Applications for such a sensor include figure and vibration control, rendezvous and docking, and structure assembly verification. The paper discusses an experimental study of SHAPES (spatial, high-accuracy, position-encoding sensor), a 3D position sensor that provides range and two angular positions of laser-illuminated retroreflector targets that mark the locations to be measured. Simultaneous range measurements to multiple targets by a time-of-flight corelation of short laser pulses are made with a CCD-equipped streak tube. Angular positions are measured with a CCD camera. Position measurements of 24 targets with sub-millimeter range accuracy at a 10 Hz update rate have been demonstrated.

Nerheim, Noble M.↗

Growth of a delta-doped silicon layer by molecular beam epitaxy on a charge-coupled device for reflection-limited ultraviolet quantum efficiency

Low-temperature silicon molecular beam epitaxy is used to grow a delta-doped silicon layer on a fully processed charge-coupled device (CCD). The measured quantum efficiency of the delta-doped backside-thinned CCD is in agreement with the reflection limit for light incident on the back surface in the spectral range of 260-600 nm. The 2.5 nm silicon layer, grown at 450 C, contained a boron delta-layer with surface density of about 2 x 10 exp 14/sq cm. Passivation of the surface was done by steam oxidation of a nominally undoped 1.5 nm Si cap layer. The UV quantum efficiency was found to be uniform and stable with respect to thermal cycling and illumination conditions.

Hoenk, Michael E.↗

Electronic Still Camera

A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

Holland, S. Douglas↗

How to get unlimited observing time on a 4 metre telescope

As the astronomical community moves ever more towards fewer and larger telescopes it is not just desirable but essential to make the maximum possible use of these new facilities. The Hitchhiker parallel CCD camera has been specially designed to increase the scientific output of a large telescope by imaging the off-axis field of view. The large data set collected by this instrument consists of deep CCD multicolor data of the distant Universe and is extremely well suited to the study of faint galaxies and their evolution, as well as other areas. The instrument's design and some of its projects are briefly discussed below and demonstrates the scientific value such instruments could have if incorporated on all new telescopes.

Driver, S. P.↗

Searching for Lyman alpha emission from a possible Zel'dovich pancake

The detection of 2 x 10(exp 14) solar mass of neutral hydrogen at a redshift of 3.397 has been reported. Top-down theories of structure formation predict such a mass of hydrogen collapsing to form a protocluster of galaxies. We sought to observe this object in Lyman-alpha, which could be produced through ionization by the metagalactic ionizing radiation field or through internal ionization processes. On 29 Apr. 1992, the region of the reported HI emission for 1800 seconds with the 1.3 meter McGraw-Hill reflector at Michigan-Dartmouth-M.I.T. Observatory was observed. Because the H1 emission reported has a transverse scale of 300 sec, a 1/3.06 reducing camera and a Thomson CCD were used to obtain a field of view of about 600 sec by 840 sec. A filter 88 A wide, centered at 5354 A was used; Lyman-alpha emission at z = 3.4 is redshifted to 5347 A. In order to avoid saturating the CCD with a bright star in the field, nine 200 second exposures were taken. The combination of these images shows no obvious extended Lyman-alpha emission at a level of about 28 magnitudes per square arcsecond. The field observed also shows a distant cluster of galaxies. In order to determine if the cluster could in any way be associated with the cloud of neutral hydrogen at z = 3.4, we sought to estimate its redshift from the size and magnitude of the galaxies and of the cluster as a whole. Omega = 1 and H(sub O) = 50 km s(sup -1) Mpc(sup -1) were adopted; our redshift estimates range from z = 0.2 to z = 0.6. The cluster is clearly not associated with the HI cloud at z = 3.4.

Cox, Caroline↗

Dust and ionized gas in elliptical galaxies: Signatures of merging collisions

Traditionally elliptical galaxies were thought to be essentially devoid of interstellar matter. However, recent advances in instrumental sensitivity have caused a renaissance of interest in dust and gas in - or associated with - elliptical galaxies. In particular, the technique of co-adding IRAS survey scans has led to the detection of more than half of all ellipticals with BT less than 11 mag. in the Revised Shapley-Ames catalog, indicating the presence of 10(exp 7) - 10(exp 8) solar mass of cold interstellar matter (Jura et al. 1987). In addition, CCD multi-color surface photometry shows dust patches in about 30 percent of the cases studied to date (e.g., Veron-Cetty & Veron 1988). Thorough study of the gas and dust in ellipticals is important to (1) determine its origin (mass-loss from late-type stars, merging collisions with other galaxies or accretion inflows from cooling X-ray gas), and (2) investigate the 3-D shape of ellipticals, as can be derived from the orientation of the dust lanes and the 2-D velocity field of the gas. An important result of our comprehensive CCD imaging program is that a relevant fraction (approximately 40 percent) of the sample objects exhibits dust patches within extended H-alpha+(NII) line-emitting filaments. This common occurrence can be easily accounted for if the dust and gas have an external origin, i.e., mergers or interactions with gas-rich galaxies. Evidence supporting this suggestion: (1) the ionized gas is usually dynamically decoupled from the stellar velocity field (see, e.g., Sharples et al. 1983, Bertola & Bettoni 1988); (2) it is shown in a companion paper (Goudfrooij et al. 1992) that internal stellar mass loss alone can not account for the dust content of elliptical galaxies.

Goudfrooij, Paul↗

Multicolor photometry of x ray selected Abell clusters

Strong evidence of evolution in cluster of galaxies at relatively low redshift has been indicated by recent x-ray studies. We are conducting a comprehensive optical study of a sample of Abell clusters that are strong x-ray emitters in order to test the x-ray evolution scenarios that have been proposed. The initial observations consist of three-color (B, R, I) imaging of low-redshift (0.025 less than z less than 0.25) Abell clusters using the T2KA CCD on the 0.9m telescope at KPNO the large field (23 ft. x 23 ft., approx. 1 Mpc at z = 0.025 and approx. 7 Mpc at z = 0.25) gives the unprecedented ability to sample most of the extent of the field of low-redshift clusters using a CCD. Given the advantages of CCDs over photographic plates, we expect to improve on many of the previous studies. A list of x-ray selected cluster of galaxies provides a homogeneous sample of true clusters that cannot be mistaken from apparent over-densities due to projection effects of field galaxies. Some optical indicators of cluster evolution are the population of ratios of cluster galaxies and their spatial distribution, a regular spiral-poor cluster is expected to be more evolved than an irregular spiral-rich cluster. Also regular spiral-poor clusters present high central concentrations while irregular spiral-rich are less concentrated. Variations in the Luminosity Function (LF) can indicate evolution. But in order to build reliable LFs it is necessary to determine the Hubble types of the cluster galaxies. In the past the classifications of cluster galaxies have been done by visual inspection on photographic material, this technique is very limited and can lead to errors when the galaxies are faint. The Hubble types of cluster galaxies can be determined in an objective manner by comparing colors and profiles from surface photometry. To show that this approach is feasible, I have presented preliminary results from the photometric analysis of the Abell-cluster A1213. Colors and profiles of the surface brightness distribution were compared to determine the Hubble types of the cluster galaxies.

Lopez-Cruz, Omar↗

New technologies for UV detectors

Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

Joseph, C. L.↗

A Compact Imaging Detector of Polarization and Spectral Content

A new type of image detector will simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging Detector (IDID) consists of a polarizing beam splitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. The polarizing beam splitter can be either a Ronchi ruling, or an array of cylindrical lenslets, bonded to a birefringent wafer. The wafer, in turn, is bonded to the CCD so that light in the two orthogonal planes of polarization falls on adjacent pairs of pixels. The use of a high-index birefringent material, e.g., rutile, allows the IDID to operate at f-numbers as high as f/3.5. Other aspects of the detector are discussed.

Rust, D. M.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗