Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Advanced ISOCS In Situ Gamma Spectrometry Services Tool to Reduce Uncertainties in Waste Characterization Projects - 16311

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function. It avoids the need for radioisotope standards which can be costly and prohibitively difficult to produce. Uncertainties in the sample - detector geometry lead to uncertainties in the calibrations. Canberra's ISOCS Uncertainty Estimator (IUE) tool offers an automated means of accommodating known model geometry uncertainties, with calculation of robust defensible calibration uncertainties. However these uncertainties may be large leading to potential over-estimation of under-estimation of activity. This can be equated directly to waste disposal costs if one is using ISOCS for waste sentencing to classify wastes as (for example) Transuranic Waste (TRU) or Low Level Waste (LLW). An Advanced ISOCS in-situ Gamma Spectrometry (AIGS) services tool has been developed to reduce the uncertainties. This system is based on generating and comparing geometry models that yield Figures of Merit (FoM) indicative of improved consistency between modelled data and available diverse measurement data. This paper describes the development and features of AIGS, focusing on recent testing with radioisotope sources in a 200 litre drum filled with a simulated waste matrix. The results demonstrate a significant advantage for Am-241 where uncertainties can otherwise amount to a factor of 2 or more. We show how our specialist teams can develop procedures for deployment of standard ISOCS hardware, adapting measurement geometries and procedures through careful planning, to provide data that can be used to greatly reduce the uncertainties in the measured activities. Lastly, we comment on the range of potential applications for this new technique and the wider benefits for the decommissioning industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiometric Calibration of A Non-Imaging Airborne Spectrometer To Measure the Greenland Ice Sheet Surface

Methods to radiometrically calibrate a non-imaging airborne visible-to-shortwave infrared (VSWIR) spectrometer to measure the Greenland ice sheet surface are presented. Airborne VSWIR measurement performance for bright Greenland ice and dark bare rock/soil targets is compared against the MODerate resolution atmospheric TRANsmission (MODTRAN ® ) radiative transfer code (version 6.0), and a coincident Landsat 8 Operational Land Imager (OLI) acquisition on 29 July 2015 during an in-flight radiometric calibration experiment. Airborne remote sensing flights were carried out in northwestern Greenland in preparation for the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2) laser altimeter mission. A total of nine science flights were conducted over the Greenland ice sheet, sea ice, and open-ocean water. The campaign's primary purpose was to correlate green laser pulse penetration into snow and ice with spectroscopic-derived surface properties. An experimental airborne instrument configuration that included a nadir-viewing (looking downward at the surface) non-imaging Analytical Spectral Devices (ASD) Inc. spectrometer that measured upwelling VSWIR (0.35 to 2.5 µm) spectral radiance (Wm −2 sr −1 µm −1 ) in the two-color Slope Imaging Multi-polarization Photon-Counting Lidar's (SIMPL) ground instantaneous field of view, and a zenith-viewing (looking upward at the sky) ASD spectrometer that measured VSWIR spectral irradiance (W m −2 nm −1 ) was flown. National Institute of Standards and Technology (NIST) traceable radiometric calibration procedures for laboratory, in-flight, and field environments are described in detail to achieve a targeted VSWIR measurement requirement of within 5 % to support calibration/validation efforts and remote sensing algorithm development. Our MODTRAN predictions for the 29 July flight line over dark and bright targets indicate that the airborne nadir-viewing spectrometer spectral radiance measurement uncertainty was between 0.6 % and 4.7 % for VSWIR wavelengths (0.4 to 2.0 µm) with atmospheric transmittance greater than 80 %. MODTRAN predictions for Landsat 8 OLI relative spectral response functions suggest that OLI is measuring 6 % to 16 % more top-of-atmosphere (TOA) spectral radiance from the Greenland ice sheet surface than was predicted using apparent reflectance spectra from the nadir-viewing spectrometer. While more investigation is required to convert airborne VSWIR spectral radiance into atmospherically corrected airborne surface reflectance, it is expected that airborne science flight data products will contribute to spectroscopic determination of Greenland ice sheet surface optical properties to improve understanding of their potential influence on ICESat-2 measurements.

Christopher J. Crawford↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

SU-E-T-191: Commissioning and Dosimetric Characteristics of Elekta Agility for Total Skin Electron Beam (TSEB) Therapy

Purpose The purpose of this work is to publish beam data from Elekta Synergy(R) linear accelerators with Agility(TM) MLC for total skin electron beam (TSEB) therapy using the HDRE1 (High Dose Rate Electron 6MeV) energy. Method & Materials The optimal gantry angles for TSEB were determined using ion chamber measurements along a vertical profile at 450cm SSD. After gantry angles were chosen, field uniformity was measured over the entire treatment area. Uniformity was measured with and without the patient support device, allowing the dosimetric effect of the support device to be determined. Beam output and PDD were measured at the calibration point (450cm SSD) for a dual beam using a parallel plate chamber in solid water. These measurements were repeated with the chamber and phantom rotated about the patient isocenter at various angles, in order to measure the contribution from oblique beams. This technique provides a precise measurement of the treatment skin dose (TSD). Lastly, ion chamber measurements were verified by film and diodes. Results The optimal gantry angle for 450 cm SSD was determined to be 90±16°. This achieved uniformity better than 96% on the vertical axis, and 92% along the horizontal axis. HDRE1 was calibrated to deliver 10 cGy/MU at standard geometry (100 cm SSD, 1.2 cm depth). Thus at TSEB geometry (450 cm SSD, 0.1 cm depth) the output of the AP dual field was measured to be 0.35 cGy/MU. The TSD of a 20 cm radius cylinder for six (equally, 60° spaced) dual fields was measured to be 1.19 cGy/MU. Percent Depth Dose data for the AP dual field and TSD are shown in Figure 2. Conclusion This paper provides a modern procedure for commissioning TSEB therapy on a linear accelerator, and clinical beam data for the Elekta Synergy(R) with Agility(TM) MLC.

60 APPLIED LIFE SCIENCES↗

Waste Characterization Using Gamma Ray Spectrometry with Automated Efficiency Optimization - 13404

Gamma ray spectrometry using High Purity Germanium (HPGe) detectors is commonly employed in assaying radioactive waste streams from a variety of sources: nuclear power plants, Department of Energy (DOE) laboratories, medical facilities, decontamination and decommissioning activities etc. The radioactive material is typically packaged in boxes or drums (for e.g. B-25 boxes or 208 liter drums) and assayed to identify and quantify radionuclides. Depending on the origin of the waste stream, the radionuclides could be special nuclear materials (SNM), fission products, or activation products. Efficiency calibration of the measurement geometry is a critical step in the achieving accurate quantification of radionuclide content. Due to the large size of the waste items, it is impractical and expensive to manufacture gamma ray standard sources for performing a measurement based calibration. For well over a decade, mathematical efficiency methods such as those in Canberra's In Situ Object Counting System (ISOCS) have been successfully employed in the efficiency calibration of gamma based waste assay systems. In the traditional ISOCS based calibrations, the user provides input data such as the dimensions of the waste item, the average density and fill height of the matrix, and matrix composition. As in measurement based calibrations, the user typically defines a homogeneous matrix with a uniform distribution of radioactivity. Actual waste containers can be quite nonuniform, however. Such simplifying assumptions in the efficiency calibration could lead to a large Total Measurement Uncertainty (TMU), thus limiting the amount of waste that can be disposed of as intermediate or low activity level waste. To improve the accuracy of radionuclide quantification, and reduce the TMU, Canberra has developed the capability to optimize the efficiency calibration using the ISOCS method. The optimization is based on benchmarking the efficiency shape and magnitude to the data available in the analyzed gamma ray spectra. Data from measurements of a given item in multiple counting geometries are among the powerful benchmarks that could be used in the optimization. Also, while assaying a waste stream with fission products and activation products emitting gamma lines of multiple energies, optimizing the efficiency on the basis of line activity consistency is very effective. In the present paper, the ISOCS- based optimization methodology is applied to measurement scenarios involving multiple counting geometries, and multi-gamma-line radionuclides. Results will be presented along with accuracy and precision estimates for each measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA s Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial and moderate resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists are also using the SSC V&V site to characterize thermal infrared systems and active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

Technical Note: Radiation properties of tissue- and water-equivalent materials formulated using the stoichiometric analysis method in charged particle therapy

Purpose: Five tissue- and water-equivalent materials (TEMs) mimicking ICRU real tissues have been formulated using a previously established stoichiometric analysis method (SAM) to be applied in charged particle therapy. The purpose of this study was an experimental verification of the TEMs-SAM against charged particle beam measurements and for different computed tomography (CT) scanners. The potential of the TEMs-SAM to be employed in the dosimetry was also investigated. Methods: Experimental verification with three CT scanners was carried out to validate the calculated Hounsfield units (HUs) of the TEMs. Water-equivalent path lengths (WEPLs) of the TEMs for proton (106.8 MeV/u), helium (107.93 MeV/u), and carbon (200.3 MeV/u) ions were measured to be compared with the computed relative stopping powers. HU calibration curves were also generated. Results: Differences between the measured HUs of the TEMs and the calculated HUs of the ICRU real tissues for all CT scanners were smaller than 4 HU except for the skeletal tissues which deviated up to 21 HU. The measured WEPLs verified the calculated WEPLs of the TEMs (maximum deviation was 0.17 mm) and were in good agreement with the calculated WEPLs of the ICRU real tissues (maximum deviation was 0.23 mm). Moreover, the relative stopping powers converted from the measured WEPLs differed less than 0.8% and 1.3% from the calculated values of the SAM and the ICRU, respectively. Regarding the relative nonelastic cross section per unit of volume for 200 MeV protons, the ICRU real tissues were generally well represented by the TEMs except for adipose which differed 3.8%. Further, the HU calibration curves yielded the mean and the standard deviation of the errors not larger than 0.5% and 1.9%, respectively. Conclusions: The results of this investigation implied the potential of the TEMs formulated using the SAM to be employed for both, beam dosimetry and HU calibration in charged particle therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fast wavelength calibration method for spectrometers based on waveguide comb optical filter

A novel fast wavelength calibration method for spectrometers based on a standard spectrometer and a double metal-cladding waveguide comb optical filter (WCOF) is proposed and demonstrated. By using the WCOF device, a wide-spectrum beam is comb-filtered, which is very suitable for spectrometer wavelength calibration. The influence of waveguide filter’s structural parameters and the beam incident angle on the comb absorption peaks’ wavelength and its bandwidth are also discussed. The verification experiments were carried out in the wavelength range of 200–1100 nm with satisfactory results. Comparing with the traditional wavelength calibration method based on discrete sparse atomic emission or absorption lines, the new method has some advantages: sufficient calibration data, high accuracy, short calibration time, fit for produce process, stability, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ monitoring of flow-permeable surface area of high explosive powder using small sample masses

To ensure good performance of high explosive devices over long periods of time, initiating powders need to maintain their specific surface area within allowed margins during the entire duration of deployment. A common diagnostic used in this context is the Fisher sub-sieve surface area (FSSA). Furthermore, commercial permeametry instruments measuring the FSSA requires the utilization of a sample mass equal to the crystal density of the sample material, an amount that is often one or two orders of magnitude larger than the typical masses found in standard detonator applications. Here we develop a customization of the standard device that can utilize just tens of milligram samples, and with simple calibration yield FSSA values at ac curacy levels comparable to the standard apparatus. This necessitated a newly designed sample holder, made from a material of low coefficient of thermal expansion, which is conveniently transferred between an aging chamber and a re-designed permeametry tube. This improves the fidelity of accelerated aging studies by allowing measurement on the same physical sample at various time - instants during the aging process, and by obviating the need for a potentially FSSA-altering powder re-compaction step. We used the customized apparatus to monitor the FSSA evolution of a number of undoped and homolog-doped PETN powder samples that were subjected to artificial aging for several months at elevated temperatures. These results, in conjunction with an Arrhenius-based aging model were used to assess powder-coarsening - rates under long-term storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of inorganic mercury by selective extraction and coprecipitation for determination of methylmercury in mercury-contaminated soils by chemical vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS)

A procedure is developed for selective extraction of methylmercury (CH 3 Hg + ) from heavily Hg-contaminated soils and sediments for determination by chemical vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS). Soils artificially contaminated with 40 μg g –1 inorganic mercury (Hg 2+ ) or methylmercury chloride (CH 3 HgCl) were agitated by shaking or exposing to ultrasounds in dilute hydrochloric acid (HCl) or nitric acid (HNO 3 ) solutions at room temperature. Extractions in HCl (5 or 10% v/v) resulted in substantial leaching of Hg 2+ from soils, whereas 5% (v/v) HNO 3 provided selectivity for quantitative extraction of CH 3 Hg + with minimum Hg 2+ leaching. Agitation with ultrasounds in 5% (v/v) HNO 3 for about 3 min was sufficient for extraction of all CH 3 Hg + from soils. Coprecipitations with Fe(OH) 3 , Bi(OH) 3 and HgS were investigated for removal of residual Hg 2+ in soil extracts. Hydroxide precipitations were not effective. Thiourea or l-cysteine added to soil extracts prior to hydroxide precipitation improved precipitation of Hg 2+ , but also resulted in removal of CH 3 Hg + . HgS precipitation was made with dilute ammonium sulfide solution, (NH 4 ) 2 S. Adding 30 μL of 0.35 mol L –1 (NH 4 ) 2 S to soil extracts in 5% (v/v) HNO 3 resulted in removal of all residual Hg 2+ without impacting CH 3 Hg + levels. Vapor generation was carried out by reacting Hg 2+ -free soil extracts with 1% (m/v) NaBH 4 . No significant interferences were observed from (NH 4 ) 2 S on the vapor generation from CH 3 Hg + . The slopes of the calibration curves for CH 3 HgCl standard solutions in 5% (v/v) HNO 3 with and without (NH 4 ) 2 S were similar. Limits of detection (LOD, 3s method) were around 0.08 μg L –1 for 5% (v/v) HNO 3 blanks (n = 10) and 0.10 μg L –1 for 5% (v/v) HNO 3 + 0.005 mol L –1 (NH 4 ) 2 S blanks (n = 10). Percent relative standard deviation (%RSD) for five replicate measurements varied between 3.1% and 6.4% at 1.0 CH 3 HgCl level. The method is validated by analysis of two certified reference materials (CRM); purely Methylmercury sediment (SQC1238, 10.00 ± 0.291 ng g –1 CH 3 Hg + ) and Hg-contaminated Estuarine sediment (ERM – CC580, 75 ± 4 ng g–1 CH 3 Hg + and 132 ± 3 μg g –1 total Hg). CH 3 Hg + values for SQC1238 were between 13.0 and 13.2 ng g –1 , and 79 and 81 ng g –1 for ERM – CC580. Hg-contaminated soils (57–96 μg g –1 total Hg) collected from the floodplains of Oak Ridge, TN were analyzed for CH 3 Hg + using the procedure by CVG-ICPMS. CH 3 Hg + levels ranged from 30 to 51 ng g –1 and did not correlate with total Hg levels (R 2 = 0.01).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sodium doping effect on physicochemical properties of K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) for the determination of mercury(II): Application in seawater samples

Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values ​​obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.

36 MATERIALS SCIENCE↗

Risk Assessment in a Chemical Laboratory Following an Explosive Incident Involving a Novel Diazonium Compound: Retrospective Analysis and Lessons Learned

Diazonium compounds are synthetically useful in the production of dyes and textiles, however they are highly explosive under dry conditions. Explosion prevention becomes more difficult when new diazonium compounds are synthesized, because while some syntheses include a counterion to increase their stability, this is not always a reliable method to prevent an explosive incident. Due to the uncertainty surrounding the explosiveness of different diazonium compounds, it is important to understand how to safely clean up after an incident and how to determine when it is safe to return a laboratory to typical operational use, particularly when the incident involves a novel compound where a standard does not exist for instrument calibration. Here, an explosive event is discussed involving the synthesis of 4-bromo-benzenediazonium-2-carboxylate. Following the explosive incident and 3-step cleanup, which involved a precautionary neutralization step, samples were collected from the fume hood where the incident occurred. Because the incident involved an unstable, novel compound that is not commercially available and was deemed unsafe to resynthesize for instrument calibration, we assessed the risk of further explosion by analyzing for the stable decomposition products. Mass spectrometry analysis confirmed that the residue in the fume hood contained 5-bromosalicylic acid, a decomposition product of 4-bromo-benzenediazonium-2-carboxylate. Samples were taken from multiple points in the fume hood and analyzed to estimate the spatial distribution of the decomposition product. Based on this analysis, we inferred that the primary decomposition product was far more abundant than residual energetic, indicating the energetic had been consumed or neutralized to a trace quantity where the risk of further explosion was low. Furthermore, the steps presented here─specifically, initial neutralization and then analyzing the spatial distribution of expected decomposition products to assess risk when a novel explosive material is detonated in a confined space─were our approach to assess further risk following an explosion due to a novel diazonium compound without the need for any further handling or resynthesis of the energetic. Here, we present our approach and critically analyze these steps by discussing retrospective lessons learned and alternative analytical approaches.

Computer simulations↗

Measuring shape and size of micrometric particles from the analysis of the forward scattered field

Characterizing nano- and micro-particles in fluids still proves to be a significant challenge for both science and industry. Here, we show how to determine shape and size distributions of polydisperse water suspensions of micron-sized particles by the analysis of the field scattered in the forward direction by single particles illuminated by a laser beam. We exploit the novel Single Particle Extinction and Scattering method in connection with shear conditions which give preferred orientations to the particles passing through the scattering volume. Water suspensions of calibrated non-spherical particles, polydisperse standard monophasic mineral samples of quartz and kaolinite, and a mixture of quartz and illite are studied in detail. Application and limitation of the method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗