Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Interfacial thermodynamics of cryogenic fluids: The effect on non-condensable gas on fluid storage

Propellant tanks that contain cryogenic fluids (CFs) in low gravity conditions are usually pressurized with non-condensable (NC) gases for fast extraction. Unfortunately, the presence of NC gases causes CFs to exhibit higher boil-offs compared to pure CF systems. For optimal utilization of the cryogenic fuels, these higher boil-off rates must be minimized. Our goal is to quantify the effects NC gases have on the evaporation and condensation dynamics of CFs to develop strategies that mitigate the higher boil-offs. The hypothesis is that the NC gas accumulates around the CF’s liquid vapor interface in the Knudsen layer, creating a kinetic barrier for both evaporation and condensation. Testing this hypothesis with experimental methods is difficult due to the transient nature of the Knudsen layer, which is only a few nanometers thick. Furthermore, experimental capabilities are limited in low gravity conditions and extremely expensive. Accordingly, we approach this problem from a theoretical perspective. In this study, we employ molecular dynamics (MD) simulations to probe the interfacial mechanisms that affect CF’s evaporation and condensation at varying concentrations of NC gases. Specifically, we use nitrogen (N2) and oxygen (O2) as our CFs and neon (Ne) as our NC gas. Using MD simulations, we show that Ne accumulates at N2 liquid vapor interface across a wide range of Ne concentrations, thereby impeding mass transport of N2. Our simulations allow for direct computation of the molar flux as well as the mass accommodation coefficient (MAC) which can then be used as input parameters to continuum fluid dynamics (CFD) models for optimal storage tank design.

Michael Robert DeLyser↗

Microbial Survival in Brewed Tea

Loose-leaf bagged tea is a commonly requested crew food item that comprises up to 7% of samples in the spaceflight food system. Tea preferences are typically specific and vary between different crew members, and there is significant interest to provide preferred food selections for the physical and mental wellbeing of the crew. Loose leaf bagged teas are made from herbs and spices that frequently have high microbial loads which do not meet the microbiological standards outlined in NASA-STD-3001. The food industry on earth does not require standards for microbial load of loose-leaf teas, because tea is brewed in boiling (100C) water, which is assumed to reduce the number of microorganisms. However, hot water from the ISS PWD is typically dispensed at a temperature between 155F (68C) and 175F (79C), which is below the suggested temperature range for safe brewing (180F/80C – 212F/100C). In this study, a commonly requested chamomile tea bags were infected with Bacillus cereus, a pathogenic, spore forming bacterium known to cause foodborne illness. Brewing B. cereus infected tea bags with boiling (212F/100C) or ISS PWD (155F/68C) temperature water showed no significant reduction in the overall microbial load of the tea (p=0.535). The addition of boiling and ISS PWD temperature water also was not sufficient to kill 100% of the infected B. cereus, and in one case of ISS PWD temperature water, B. cereus was detected at levels above a previously reported infectious dose. This study showed that the microbiological risk associated with drinking brewed tea on ISS is not reduced by the brewing process.

S G Thornhill↗

Endogenous Microbial Survival in Brewed Tea

Loose-leaf bagged tea is a commonly requested beverage item that comprises up to 7% of the microbiological samples from the space food systems. As loose-leaf tea blends often contain herbs and spices that frequently have high microbial loads, they have a high failure rate as defined by the microbiological standards outlined in NASA-STD-3001, which are more stringent than the limits set for industry. Between April 2019 and September 2022, 54.8% of loose-leaf teas submitted for microbiological testing have failed, necessitating the evaluation of a variety of brands and lot numbers of each requested tea type to meet crew preference requests, which are typically specific, resulting in excess labor and material costs to provide a single product for spaceflight consumption. Attempts to identify specific brands or ingredients that are less likely to produce a failure have been unsuccessful, as to date, no trends in those measures have been identified. We have, however, noticed a trend in types of teas (spiced and herbal) which are more likely to fail. Of additional concern, hot water available for brewing tea on ISS is dispensed at a lower temperature than the CDC recommended brewing temperature. In a study we previously reported, we found that that brewing water temperature may not have a significant impact on the number of aerobic bacteria in chamomile tea, as there were no significant differences in the total microbial load between tea brewed with boiling, ISS-like, or room temperature waters. It did appear that ISS temperature water was similarly effective to boiling water against a pathogenic bacterial species. In this study, we aim to assess whether the total number of aerobic bacteria of other high-fail-rate tea types is similarly unaffected when brewing tea in room temperature or boiling water. Data from this study and the previous study, as well as additional analysis of every tea product that has been tested as part of the normal food system since April 2019, will be used to determine the expected typical microbial load for loose-leaf teas, which we will compare to existing industry limits so that we can recommend a new microbiological limit for loose-leaf teas that accurately reflects the true risk of consuming brewed teas in spaceflight.

space flight food↗

Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCANAIR-BISON BENCHMARK ON CIP0-1 RIA TEST

In the frame of their research programs on fuel safety, the French “Institut de Radioprotection et de Sûreté Nucléaire” (IRSN) and the Idaho National Laboratory (INL) have developed respectively SCANAIR and BISON codes to describe the thermo-mechanical behavior of irradiated fuel rods during Reactivity Initiated Accidents (RIA) in LWR. A RIA, characterized by a very rapid increase of reactivity and power in some rods of the reactor, can be schematically represented in two main phases. First, the energy deposition leads to a rapid rise of the fuel temperature which induces thermal swelling of the fuel pellets. During this phase, the Pellet Clad Mechanical Interaction (PCMI) leads to clad deformation and potentially to failure depending on fuel enthalpy increase and on the level of clad embrittlement. After the PCMI phase, the increase of clad temperature can lead to the boiling crisis of the water surrounding the rod. During the film boiling phase, the clad to coolant heat transfer becomes very low and the clad can reach high temperature (>700°C). Depending on the internal gas pressure, the ductile clad can undergo large deformation and possible failure. The RIA codes have to predict properly these two phases of the transient in order to be used, in particular, to assess current fuel safety criteria but also to be able to predict the behavior of upcoming fuel (such as accident tolerant fuel). In this paper, codes computation comparison against experimental data obtained on CIP0-1 test is done for the first phase of the transient, the PCMI phase, in order to point out the strengths and weaknesses of the codes. The CIP0-1 experiment was performed with UO2 high burnup fuel in the CABRI sodium loop facility, at 280°C and low pressure (~3 bars) without boiling crisis and no failure of the fuel rod. The initial state of the rod calculated by irradiation codes are compared with measurements before the transient. Then global rod thermal behavior during the CIP0-1 test is assessed with the sodium coolant temperature measurements. The rod mechanical behavior is analyzed with the fuel and clad elongation and the clad residual hoop strain. Finally comparison of the fission gas behavior between codes is performed and compared to the measurements of the fission gas released in the experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity and uncertainty analysis for a combined depletion and criticality calculation chain of a BWR FA

This paper examines the prerequisites and boundary conditions for extending burnup credit from pressurized water reactors to boiling water reactors with validated depletion codes by performing uncertainty and sensitivity analyses on a modern boiling water reactor fuel assembly design. We developed a computational chain consisting of an axial boiling water reactor axial irradiation model, followed by a series of depletion calculations and a three-dimensional criticality calculation. The irradiation model puts into relation the profiles of power, burnup and moderator density of the fuel assembly at 24 axial locations. In a simplified fashion it also includes the insertion of control blades. The depletion calculations of the fuel assembly were performed in axial slices with the 2D-depletion code HELIOS 1.12. The criticality calculations were done in 3D-geometry with KENO-Va from the SCALE 6.2.1 package, in which several fuel assemblies are placed into a generic transport cask. For the uncertainty and sensitivity analyses a Monte Carlo sampling based approach is used applying the GRS tool SUnCISTT. We performed several generic investigations testing the capabilities and the limitations of the whole computational chain. The impact of variations of the irradiation model on the resulting reactivity of the fuel assemblies inside a transport cask or storage pool was investigated using an uncertainty and sensitivity analysis on the whole computational chain. Geometrical uncertainties were also included in the evaluation and a parameter study on the use of control blades during irradiation was performed. The goal was to develop the procedures and tools to be able to obtain quantitative uncertainty data which can be used in the future to derive conservative irradiation profiles without unnecessary excess reactivity margins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unforeseen Events Alter Stewardship Strategies at the Decommissioned BONUS Reactor in Puerto Rico - 19572

The decommissioned Boiling Nuclear Superheater (BONUS) reactor northwest of Rincon, Puerto Rico, was developed as a prototype nuclear power plant to investigate the feasibility of the integral boiling superheating concept. Through a combined effort of the US Atomic Energy Commission (AEC) and the Puerto Rico Water Resources Authority (PRWRA), the reactor first achieved a controlled nuclear chain reaction in 1964 and remained operational until June 1968. It was the eighth nuclear reactor constructed in the world and one of only two boiling-water superheater reactors ever developed in the United States. Following its decommissioning in 1970, AEC, the predecessor to the US Department of Energy (DOE), and PRWRA, the predecessor to the Puerto Rico Electric Power Authority (PREPA), worked together post-closure to address the remaining residual contamination and safely open the facility to the public for science educational outreach. Presently, the DOE Office of Legacy Management (LM) has long-term stewardship responsibilities for the reactor entombment, which includes periodic site inspections of the entombment system and oversight of the Radiological Protection Program (RPP) implemented by PREPA. PREPA has responsibility for conducting radiological measurements in accordance with the approved RPP for the facility, recordkeeping and reporting, and facility control and maintenance. The entombment system has a design life of 140 years; DOE has an obligation to ensure long-term protectiveness at the site for the next 90 years until the contact dose of the entombment system reaches background conditions. As part of the long-term protectiveness strategy, in September 2000, the BONUS reactor facility was renamed the Dr. Modesto Iriarte Technology Museum, and then in 2007, the facility was listed under the National Register of Historical Places. The museum contains numerous displays that recount the history of the BONUS site, as well as the development of electric power and nuclear energy, and receives approximately 100 visitor requests each year. The best long-term strategies need to be flexible and are subject to change. As such, the long-term maintenance responsibilities at the BONUS reactor facility were formerly documented in the 2010 Letter of Agreement between LM and PREPA to reaffirm the joint commitment of long-term protectiveness. This commitment did not waiver despite two devastating hurricanes in 2017, Irma and Maria, and the recent bankruptcy filing by the territory of Puerto Rico. To address the financial uncertainties facing PREPA, secure LM's commitment to long-term stewardship liabilities in the future, and offer a level of care similar to that at other LM sites, LM has offered several strategic opportunities to ensure the long-term sustainability of the site. Both LM and PREPA share a common and long-term stewardship commitment at the BONUS reactor facility, which includes ensuring protectiveness of the entombed radiological waste material. Protection of human health and the environment is at the forefront of the DOE mission, and the beneficial reuse of legacy sites continues to be a goal of the agency. The collaborative ability of both organizations to transform a Cold War-era facility such as a former nuclear reactor to an educational center embodies a unique ability to present local history while educating future generations on LM's mission to protect human health and the environment across the 92 sites it manages. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding and Controlling Cesium Loading on Crystalline Silicotitanate - 19601

Savannah River Remediation (SRR) contracted with Westinghouse Electric Corporation (WEC), Columbia Energy and Environmental Services (CEES), to build and deliver a modular ion exchange process that will be used to remove radioactive cesium from dissolved salt solution contained in Tank 10 at the Savannah River Site (SRS). The resulting decontaminated salt solution will be sent to Tank 11 and then to Tank 50 for final disposition in grout at the Saltstone facility. At the end of processing, the loaded ion exchange (IX) columns are drained, rinsed, and dried. The IX columns are removed from the modular unit and stored at Interim Safe Storage (ISS). This ion exchange process is called the Tank Closure Cesium Removal (TCCR) system. The TCCR system consists of several unit operations and process monitoring capability housed within three modular units. The first modular unit contains the process control computer, the second modular unit contains the main process equipment (two prefilters, four IX columns, and resin trap (post filtration)), and the third modular unit is the ventilation system. The main unit operations of the TCCR system are filtration, ion exchange, and ventilation. The ion exchange media utilized is a form of inorganic Crystalline Silicotitanate (CST), IONSIV{sup TM} R9120-B supplied by UOP Honeywell. CST has a high selectivity for cesium (Cs) and has some affinity for other Group IA alkali metals on the periodic chart (hydrogen, lithium, sodium, potassium, rubidium, and francium). CST has also been shown to have affinity for strontium and actinides. Cesium loading on the CST is dependent on many factors including chemical composition (cations and anions), temperature, and pH of the salt solution. The actual amount of Cs loaded onto an IX column is dependent on the factors above along with the salt solution volume fed to the IX column. Because of CST's high selectivity for Cs, the Cs-137 equilibrium loading can contribute enough decay heat to result in an ion exchange column boiling event under no flow conditions in the IX column. The boiling event under no flow is a safety concern that must be prevented from occurring. To prevent boiling of the column under no flow conditions, the Cs-137 equilibrium loading must be determined and understood. Several methodologies were evaluated for performing the Cs-137 equilibrium loading determination for CST. After review of available research and development (R and D), batch equilibrium contact test data, and Zheng Anthony Miller (ZAM) model predictions for the salt solution chemistry in Tank 10, a methodology for determining the Cs-137 equilibrium loading on CST was selected. The methodology selected involves an in-tank batch equilibrium contact test performed in duplicate that considers additional corrections to account for anticipated operational evolutions. The in-tank batch equilibrium contact test utilizes ∼0.1 grams of CST secured in a slotted sample vial. The slotted sample vial design allows for salt solution to be in contact with the CST. The slotted sample vials containing the CST are submerged in Tank 10 and exposed to the salt solution for ten days. After ten days, the samples are retrieved and sent to the Savannah River National Laboratory (SRNL) for analysis of the Cs-137 equilibrium loading. Additional corrections are then made to the Cs-137 results to account for anticipated operational evolutions. Anticipated operational evolutions include external additions (water/caustic) to Tank 10 that result in a change to its chemical composition, tank temperature effects, departures from the laboratory testing (mixed vs. stagnant tank conditions), and IX column flushes. A description of the methodologies considered, feasibility of methodology deployment, and the down select process (benefits vs. risks) is discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

An experimental study of the role of subsurface plumbing on geothermal discharge

In order to better understand the diverse discharge styles and eruption intervals observed at geothermal features, we performed here three series of laboratory experiments with differing plumbing geometries. A single, straight conduit that connects a hot water bath (flask) to a vent (funnel) can originate geyser-like periodic eruptions, continuous discharge like a boiling spring, and fumarole-like steam discharge, depending on the conduit length and radius. The balance between the heat loss from the conduit walls and the heat supplied from the bottom determines whether and where water can condense which in turn controls discharge style. Next, we connected the conduit to a cold water reservoir through a branch, simulating the inflow from an external water source. Colder water located at a higher elevation than a branching point can flow into the conduit to stop the boiling in the flask, controlling the periodicity of the eruption. When an additional branch is connected to a second cold water reservoir, the two cold reservoirs can interact. Our experiments show that branching allows new processes to occur, such as recharge of colder water and escape of steam from side channels, leading to greater variation in discharge styles and eruption intervals. This model is consistent with the fact that eruption duration is not controlled by emptying reservoirs. We show how differences in plumbing geometries can explain various discharge styles and eruption intervals observed in El Tatio, Chile, and Yellowstone, USA.

58 GEOSCIENCES↗

Thermal stability of the complex of pyrene–β-cyclodextrin dimer with aromatic amino acids

Using the method of adsorption spectroscopy, the temperature dependence of the electronic absorption spectra of the fluorescent chemosensor (CS), based on the supramolecular pyrene–2β-cyclodextrin complex (Pyr@2βCD, PCD), was studied in the absence and in the presence of phenylalanine (Phe). The application of CS, where pyrene serves as a fluorescent probe, is based on the ability of CS to form the inclusion complexes with small organic molecules as well as with aromatic amino acids (AA) such as Phe, tryptophan (Trp), tyrosine (Tyr), and histidine (His) in aqueous solutions. Upon heating to 55 °C, the PCD complex in the presence of Phe shows a higher stability as compared to that in the absence of Phe. The molecular dynamics simulation was applied to study the thermal stability of PCD and its complexes with the above AAs in water. The PCD complex exists in two configurations. In configuration 1 the planar Pyr molecule lies in the equatorial plane of the βCD dimer, the plane of Pyr is nearly perpendicular to the vertical axis of the dimer 2βCD, and water fills up the empty part of the cavity. In configuration 2, the plane of Pyr is inclined with respect to the axis of the 2βCD dimer by ~30°. The PCD complex initially prepared in state 1 is spontaneously transformed into state 2 and remains stable up to the boiling temperature. The transition of PCD from the form 1 to 2 is provided by fluctuations in water content in its cavities. The inclusion complexes of amino acids 2AA@PCD exist in a single conformation 1. Complexes of PCD with Trp and Phe are stable up to the boiling temperature, i.e., these AAs are preserved within the PCD cavities even at the elevated temperature. The complex with Tyr decays at 60 °C, and the complex with His is unstable at room temperature and above.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the prediction of critical heat flux using a physics-informed machine learning-aided framework

The critical heat flux (CHF) corresponding to the departure from nucleate boiling (DNB) crisis is essential to the design and safety of a two-phase flow boiling system. Despite the abundance of predictive tools available to the thermal engineering community, the path for an accurate, robust CHF model remains elusive due to lack of consensus on the DNB triggering mechanism. This work aims to apply a physics-informed machine learning (ML)-aided hybrid framework to achieve superior predictive capabilities. Such a hybrid approach takes advantage of existing understanding in the field of interest (i.e., domain knowledge) and uses ML to capture undiscovered information from the mismatch between the actual and domain knowledge-predicted target. A detailed case study is carried out with an extensive DNB-specific CHF database to demonstrate (1) the improved performance of the hybrid approach as compared to traditional domain knowledge-based models, and (2) the hybrid model’s superior generalization capabilities over standalone ML methods across a wide range of flow conditions. The hybrid framework could also readily extend its applicability domain and complexity on the fly, showing an elevated level of flexibility and robustness. Based on the case study conclusions, the window-type extrapolation mapping methodology is further proposed to better inform high-cost experimental work.

42 ENGINEERING↗

Effect of helical micro-fins on two-phase flow behavior of R410A evaporating in horizontal round tubes obtained through visualization

This paper presents a new approach in visualization of the evaporation mechanism and the two phase flow. The visualization test section is a transparent micro-fin tube made by 3D printing. The 3D printing technology helps reproduce the real geometry in commercial metal micro-fin tubes. Even though the wall material is different from the real metal, this new method provides a more complete understanding of the mechanisms of flow boiling and the heat transfer enhancement due to micro-fin geometry. To investigate the effect of micro-fin geometries on two-phase flow behavior, R410A flow boiling experiments are conducted at 1°C saturation temperature and visualized through a clear smooth tube and micro-fin tubes of 0°, 10° and 18° helix angles. The results showed that the annular flow pattern in the helical micro-fin tube occurred at a lower vapor quality than the smooth and axial micro-fin tubes. Helix angle affects the transition boundary of stratified wavy flow to wavy annular flow, which shifts downward (to lower mass flux and vapor quality conditions) as the helix angle increases. Other transitions are not significantly affected by the helix angle. Helical micro-fin tubes with different groove directions were made to understand the flow behavior on the upward side and downward side of the tube.

3D printing↗