Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Hand-held UXO Discriminator

With prior funding (UX-1225, MM-0437, and MM-0838), we have successfully designed and built a cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (e.g., Gasperikova et al., 2007, 2009). It is a multi-transmitter multi-receiver active electromagnetic system that is able to discriminate UXO from scrap at a single measurement position, hence eliminates equirement of a very accurate sensor location. The cart-mounted system comprises of three orthogonal transmitters and eight pairs of differenced receivers (Smith et al., 2007). Receiver coils are located on ymmetry lines through the center of the system and see identical fields during the on-time of the pulse in all of the transmitter coils. They can then be wired in opposition to produce zero output during the n-ime of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform ver the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt of the receivers in the Earth's magnetic field, and therefore reatly enhances receivers sensitivity to the gradients of the target.

54 ENVIRONMENTAL SCIENCES↗

MADmap: A MASSIVELY PARALLEL MAXIMUM LIKELIHOOD COSMIC MICROWAVE BACKGROUND MAP-MAKER

MADmap is a software application used to produce maximum likelihood images of the sky from time-ordered data which include correlated noise, such as those gathered by cosmic microwave background (CMB) experiments. It works efficiently on platforms ranging from small workstations to the most massively parallel supercomputers. Map-making is a critical step in the analysis of all CMB data sets, and the maximum likelihood approach is the most accurate and widely applicable algorithm; however, it is a computationally challenging task. This challenge will only increase with the next generation of ground-based, balloon-borne, and satellite CMB polarization experiments. The faintness of the B-mode signal that these experiments seek to measure requires them to gather enormous data sets. MADmap is already being run on up to O(10{sup 11}) time samples, O(10{sup 8}) pixels, and O(10{sup 4}) cores, with ongoing work to scale to the next generation of data sets and supercomputers. We describe MADmap's algorithm based around a preconditioned conjugate gradient solver, fast Fourier transforms, and sparse matrix operations. We highlight MADmap's ability to address problems typically encountered in the analysis of realistic CMB data sets and describe its application to simulations of the Planck and EBEX experiments. The massively parallel and distributed implementation is detailed and scaling complexities are given for the resources required. MADmap is capable of analyzing the largest data sets now being collected on computing resources currently available, and we argue that, given Moore's Law, MADmap will be capable of reducing the most massive projected data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Post-embedding tem signal-to-noise ratio of S-100

We assessed the reactivity of purified S-100 antiserum in immuno-electron microscopy by counting the number of gold particles per microns 2 over inner ear tissues embedded in different media. Sections containing predominantly Schwann's cell cytoplasm and nucleus, afferent fiber axoplasm and myelin sheath of chick cochleae were reacted with anti-S-100 IgG, an antibody to a calcium binding protein of neuronal tissues, then labeled with anti-IgG-gold conjugate. This investigation was conducted because previously published procedures, unmodified, did not yield acceptable results. Preparation of all specimens was identical. Only the medium (PolyBed 812, Araldite or Spurr epoxies; and LR White, LR Gold or Lowicryl plastics) was changed. The medium was made the changing variable because antigens available in post-embedding immuno-electron microscopy are decreased by heat, either used and/or released during polymerization of the embedding medium. The results indicate that: (a) none of the embedding media above provided optimal signal-to-noise ratio for all parts of the nerve stained in the same section; (b) aggregation of gold particles over cells was highest in embedding media with high background labeling over areas devoid of tissue (noise); (c) aggregation occurred randomly throughout both cellular and acellular regions; and (d) particles aggregated less and were distributed more evenly in tissues from media yielding good ultrastructural integrity.

Non-NASA Center↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Ultra-Sensitive Transition-Edge Sensors for the Background Limited Infrared/Sub-mm Spectrograph (BLISS)

We report progress in fabricating ultra-sensitive superconducting transition-edge sensors (TESs) for BLISS. BLISS is a suite of grating spectrometers covering 35-433 micron with R approx. 700 cooled to 50 mK that is proposed to fly on the Japanese space telescope SPICA. The detector arrays for BLISS are TES bolometers readout with a time domain SQUID multiplexer. The required noise equivalent power (NEP) for BLISS is NEP = 10(exp -19) W/Hz(exp 1/2) with an ultimate goal of NEP= 5 x 10(exp -20) W/Hz(exp 1/2) to achieve background limited noise performance. The required and goal response times are tau = 150 ms and tau = 50ms respectively to achieve the NEP at the required and goal optical chop frequency 1-5 Hz. We measured prototype BLISS arrays and have achieved NEP = 6 x 10(exp -18) W/Hz(exp 1/2) and tau = 1.4 ms with a Ti TES (T(sub C) = 565 mK) and NEP approx. 2.5 x 10(exp -19) W/Hz(exp 1/2) and tau approximates 4.5 ms with an Ir TES (T(sub C) = 130 mK). Dark power for these tests is estimated at 1-5 fW.

transition-edge sensors (TESs)↗

MADmap: A Massively Parallel Maximum-Likelihood Cosmic Microwave Background Map-Maker

MADmap is a software application used to produce maximum-likelihood images of the sky from time-ordered data which include correlated noise, such as those gathered by Cosmic Microwave Background (CMB) experiments. It works efficiently on platforms ranging from small workstations to the most massively parallel supercomputers. Map-making is a critical step in the analysis of all CMB data sets, and the maximum-likelihood approach is the most accurate and widely applicable algorithm; however, it is a computationally challenging task. This challenge will only increase with the next generation of ground-based, balloon-borne and satellite CMB polarization experiments. The faintness of the B-mode signal that these experiments seek to measure requires them to gather enormous data sets. MADmap is already being run on up to O(1011) time samples, O(108) pixels and O(104) cores, with ongoing work to scale to the next generation of data sets and supercomputers. We describe MADmap's algorithm based around a preconditioned conjugate gradient solver, fast Fourier transforms and sparse matrix operations. We highlight MADmap's ability to address problems typically encountered in the analysis of realistic CMB data sets and describe its application to simulations of the Planck and EBEX experiments. The massively parallel and distributed implementation is detailed and scaling complexities are given for the resources required. MADmap is capable of analysing the largest data sets now being collected on computing resources currently available, and we argue that, given Moore's Law, MADmap will be capable of reducing the most massive projected data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrievals of Thick Cloud Optical Depth from the Geoscience Laser Altimeter System (GLAS) by Calibration of Solar Background Signal

Laser beams emitted from the Geoscience Laser Altimeter System (GLAS), as well as other space-borne laser instruments, can only penetrate clouds to a limit of a few optical depths. As a result, only optical depths of thinner clouds (< about 3 for GLAS) are retrieved from the reflected lidar signal. This paper presents a comprehensive study of possible retrievals of optical depth of thick clouds using solar background light and treating GLAS as a solar radiometer. To do so we first calibrate the reflected solar radiation received by the photon-counting detectors of GLAS' 532 nm channel, which is the primary channel for atmospheric products. The solar background radiation is regarded as a noise to be subtracted in the retrieval process of the lidar products. However, once calibrated, it becomes a signal that can be used in studying the properties of optically thick clouds. In this paper, three calibration methods are presented: (I) calibration with coincident airborne and GLAS observations; (2) calibration with coincident Geostationary Operational Environmental Satellite (GOES) and GLAS observations of deep convective clouds; (3) calibration from the first principles using optical depth of thin water clouds over ocean retrieved by GLAS active remote sensing. Results from the three methods agree well with each other. Cloud optical depth (COD) is retrieved from the calibrated solar background signal using a one-channel retrieval. Comparison with COD retrieved from GOES during GLAS overpasses shows that the average difference between the two retrievals is 24%. As an example, the COD values retrieved from GLAS solar background are illustrated for a marine stratocumulus cloud field that is too thick to be penetrated by the GLAS laser. Based on this study, optical depths for thick clouds will be provided as a supplementary product to the existing operational GLAS cloud products in future GLAS data releases.

Yang, Yuekui↗

Adaptive Thresholding and Parameter Estimation for PPM

A method of adaptive setting of a threshold level for the detection of pulses in a pulse-position modulation (PPM) free-space optical communication system has been developed. In simplified terms, it is desirable to set a threshold value high enough to greatly reduce the probability (PFA as defined below) of erroneously detecting noise as signal pulses but not so high as to greatly reduce the probability (PD as defined below) of detecting any signal pulses that may be present along with noise. In the present method, the threshold level is varied with time, in response to changing conditions in the optical-communication channel, in an effort to maintain a balance between the aforesaid competing requirements. An integral part of this adaptation scheme is a scheme for estimating key parameters of the optical-communication channel in particular, parameters that describe the fading and total attenuation in the channel, and parameters that characterize spreading of pulses by atmospheric and other effects. The method can be implemented by software processing of digitized optoelectronic-detector output, and has been tested by computational simulation. In the first stage of processing by this method, the digitized values of the detector output during noise-only time slots of received PPM symbols are averaged to obtain a background level. This background level is subtracted from the detector output in the hope of reducing or eliminating the noise component in the remaining signal. (This background level should not be confused with the detection threshold, which is computed in the last stage of processing.) Next, the remaining signal - in effect, a vector of pulse samples - is normalized by dividing it by its L1 norm (in general, the L1 norm of a vector is defined as the sum of absolute magnitudes of its orthogonal components).

Arabshahi, Payman↗

Improving the space surveillance telescope's performance using multi-hypothesis testing

The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers

For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HST/COS OBSERVATIONS OF THE QUASAR HE 2347-4342: PROBING THE EPOCH OF He II PATCHY REIONIZATION AT REDSHIFTS z = 2.4-2.9

We report ultraviolet spectra of the high-redshift (z{sub em} {approx} 2.9) quasar, HE 2347 - 4342, taken by the Cosmic Origins Spectrograph (COS) on the Hubble Space Telescope. Spectra in the G130M (medium resolution, 1135-1440 A) and G140L (low resolution, 1030-2000 A) gratings exhibit patchy Gunn-Peterson absorption in the 303.78 A Ly{alpha} line of He II between z = 2.39-2.87 (G140L) and z = 2.74-2.90 (G130M). With COS, we obtain better spectral resolution, higher signal-to-noise ratio (S/N), and better determined backgrounds than previous studies, with sensitivity to abundance fractions x{sub He{sub II}} {approx} 0.01 in filaments of the cosmic web. The He II optical depths from COS are higher than those with the Far Ultraviolet Spectroscopic Explorer and range from {tau}{sub He{sub II}} {<=} 0.02 to {tau}{sub He{sub II}} {>=} 5, with a slow recovery in mean optical depth to ({tau}{sub He{sub II}}) {<=} 2 at z < 2.7. The He II/H I optical-depth ratio varies ({eta}{approx} 10-100 for 2.4 < z < 2.73 and {eta} = 5-500 for 2.75 < z < 2.89) on scales {Delta}z {approx}< 0.01 (10.8 Mpc in comoving radial distance at z = 2.8), with numerous flux-transmission windows between 1135 and 1186 A. The He II absorption extends to 1186.26 A (z = 2.905), including associated absorbers with z{sub abs} {approx} z{sub QSO} and minimal 'proximity effect' of flux transmission at the He II edge. We propose a QSO systemic redshift z{sub QSO} = 2.904 {+-} 0.002, some {Delta}z = 0.019 higher than that derived from O I {lambda}1302 emission. Three long troughs (4-10 A or 25-60 Mpc comoving distance) of strong He II absorption between z = 2.75and2.90 are uncharacteristic of the intergalactic medium if He II reionized at z{sub r} {approx} 3. Contrary to recent indirect estimates (z{sub r} = 3.2 {+-} 0.2) from H I optical depths, the epoch of He II reionization may extend to z {approx}< 2.7.

79 ASTRONOMY AND ASTROPHYSICS↗

Using CN 3883-A spectroheliograms to map weak photospheric magnetic fields.

By photographically averaging time sequences of high-resolution CN 3883-A spectroheliograms, the noise level due to the rapidly fluctuating intensity of the solar background has been reduced significantly. Very faint faculae that are lost in the noise on a single frame are easily visible on such an enhanced picture. A comparison between these enhanced spectroheliograms and a photoelectric magnetogram suggests that the brightness-magnetic field correlation extends to much weaker field strengths and fainter faculae than can be detected on a single, high quality CN spectroheliogram.

Sheeley, N. R., Jr.↗

Online thermal profile prediction for large format additive manufacturing: A hybrid CNN-LSTM based approach

Large format additive manufacturing (LFAM) is an advanced 3D printing technique that efficiently fabricates large-scale components through a layer-by-layer extrusion and deposition process. Accurate surface layer temperature monitoring is essential to prevent manufacturing failures and ensure final product quality. Traditional physics-based offline approaches for simulating thermal behavior are often inefficient and complex, posing challenges on real-time, in-situ monitoring. Here, to address this, we propose a data-driven hybrid CNN-LSTM model to predict sequential thermal images of arbitrary length using real-time infrared thermal imaging. In this approach, a Convolutional Neural Networks (CNN) is trained offline to capture spatial features, reduce dimensional complexity, and enhance time efficiency, while a stacked Long Short-Term Memory (LSTM) is applied online to capture temporal information for improved prediction of future thermal behavior in subsequent printing layers. Model performance is evaluated using MSE, SSIM, and PSNR metrics and is benchmarked against stacked LSTM and convolutional LSTM models, demonstrating superior accuracy and applicability. Additionally, to mitigate noise from moving extruders and gantry backgrounds in thermal images, a fine-tuned semantic segmentation model is implemented offline to extract printing geometry, enabling precise temperature tracking along the tool path for further thermal analysis. The frameworks developed in this study significantly advance temperature monitoring, thermal analysis, and in-situ manufacturing control for LFAM, bridging the gap between theoretical modeling and practical application.

Geometry extraction↗

Caged luciferins for bioluminescent activity-based sensing

Bioluminescence imaging is a powerful modality for in vivo imaging owing to its low background and high signal-to-noise ratio. Because bioluminescent emission occurs only upon the catalytic reaction between the luciferase enzyme and its luciferin substrate, caging luciferins with analyte-reactive triggers offers a general approach for activity-based sensing of specific biochemical processes in living systems across cell, tissue, and animal models. In this review, we summarize recent efforts in the development of synthetic caged luciferins for tracking enzyme, small molecule, and metal ion activity and their contributions to physiological and pathological processes.

59 BASIC BIOLOGICAL SCIENCES↗

Pulse height model for deuterated scintillation detectors

This work includes the theoretical calculation of pulse height distribution and elaborate measurement at Ohio University using deuterated organic scintillation detector, which allows us to thoroughly investigate the light output spectrum induced by fast neutrons and convincingly compensate the pulse deficiency due to application of threshold to minimize noises either from electronics or environmental background. Specifically, a complete and self-contained analytic model of pulse height distribution for EJ-315 is created. In the model, considering impacts of detector geometry on light output and neutron leakage, a non-uniform angular distribution is also taken into account. An energy range of incident neutron from 1 MeV to 10 MeV is investigated. In return, based on the Peierls-formula, the completed calculation exhibits quantitative probability of fast neutron slowing down history due to stochastic collisions with carbon or deuterium nuclei. The quantitative collision probability conjoining with light output function, which was measured and corrected in view of detector response to several gamma rays, for continuous neutron flux generated by the tandem Van De Graaff Generator gives the light output for various collisions. Furthermore, the individual collision structure of the light pulse spectrum is analyzed and compared to the corresponding pulse height distribution from experimental measurement. Lastly, the resulting light pulse height distribution generated in this model offers intriguing advantages for identifying or characterizing nuclear materials and estimating potentials of various fast recoil detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

We report past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal-to-background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09–360 ppb, a 1.4–13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1– 840 ppb),with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from0.5–2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4–2.4% RSD observed when no spatial filtering is used. In conclusion, spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tile-Based Fisher-Ratio Software for Improved Feature Selection Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Data

Two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a highly capable instrumental platform that produces complex and information-rich multi-dimensional chemical data. The complex data can be overwhelming, especially when many samples (of various sample classes) are analyzed with multiple injections for each sample. Thus, the data must be analyzed in such a way to extract the most meaningful information. The pixel-based and peak table-based algorithmic use of Fisher ratios has been used successfully in the past to reduce the multi-dimensional data down to those chemical compounds that are changing between classes relative to those that are not (i.e., chemical feature selection). We report on the initial development of a computationally fast novel tile-based Fisher-ratio software that addresses challenges due to 2D retention time misalignment without explicitly aligning the data, which is a problem for both pixel-based and peak table- based methods. Concurrently, the tile-based Fisher-ratio software maximizes the sensitivity contrast of true positives against a background of potential false positives and noise. To study this software, eight compounds, plus one internal standard, were spiked into diesel at various concentrations. The tile-based F-ratio software was able to discover all spiked analytes, within the complex diesel sample matrix with thousands of potential false positives, in each possible concentration comparison, even at the lowest absolute spiked analyte concentration ratio of 1.06.

chemometrics↗