Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Using support vector machines to improve elemental ion identification in macromolecular crystal structures

A method to automatically identify possible elemental ions in X-ray crystal structures has been extended to use support vector machine (SVM) classifiers trained on selected structures in the PDB, with significantly improved sensitivity over manually encoded heuristics. In the process of macromolecular model building, crystallographers must examine electron density for isolated atoms and differentiate sites containing structured solvent molecules from those containing elemental ions. This task requires specific knowledge of metal-binding chemistry and scattering properties and is prone to error. A method has previously been described to identify ions based on manually chosen criteria for a number of elements. Here, the use of support vector machines (SVMs) to automatically classify isolated atoms as either solvent or one of various ions is described. Two data sets of protein crystal structures, one containing manually curated structures deposited with anomalous diffraction data and another with automatically filtered, high-resolution structures, were constructed. On the manually curated data set, an SVM classifier was able to distinguish calcium from manganese, zinc, iron and nickel, as well as all five of these ions from water molecules, with a high degree of accuracy. Additionally, SVMs trained on the automatically curated set of high-resolution structures were able to successfully classify most common elemental ions in an independent validation test set. This method is readily extensible to other elemental ions and can also be used in conjunction with previous methods based on a priori expectations of the chemical environment and X-ray scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving Positioning in High-Dose Radiotherapy for Prostate Cancer: Safety and Visibility of Frequently Used Gold Fiducial Markers

Purpose: The use of gold fiducial markers (GFMs) for prostate positioning in high-dose radiotherapy is gaining interest. The purpose of this study was to compare five GFMs regarding feasibility of ultrasound-based implantation in the prostate and intraprostatic lesion (IPL); toxicity; visibility on transabdominal ultrasound (TU) and cone-beam CT (CBCT); reliability of automatic, soft tissue, and GFM-based CBCT patient positioning by comparing manual and automatic fusion CBCT. Methods and Materials: Twenty-five patients were included. Pain and toxicity were scored after implantation and high-dose radiotherapy. Fisher exact test was used to evaluate the correlation of patients' characteristics and prostatitis. Positioning was evaluated on TU and kilovoltage CBCT images. CBCT fusion was performed automatically (Elekta XVI technology, release 3.5.1 b27, based on grey values) and manually on soft tissue and GFMs. Pearson correlation statistics and Bland-Altman evaluation were used. Five GFMs were compared. Results: Twenty percent of the patients developed prostatitis despite antibiotic prophylaxis. Cigarette smoking was significantly correlated with prostatitis. The visualization of all GFMs on TU was disappointing. Consequently we cannot recommend the use of these GFMs for TU-based prostate positioning. For all GFMs, there was only fair to poor linear correlation between automatic and manual CBCT images, indicating that even when GFMs are used, an operator evaluation is imperative. However, when GFMs were analyzed individually, a moderate to very strong correlation between automatic and manual positioning was found for larger GFMs in all directions. Conclusion: The incidence of prostatitis in our series was high. Further research is imperative to define the ideal preparation protocol preimplantation and to select patients. Automatic fusion is more reliable with larger GFMs at the cost of more scatter. The stability of all GFMs was proven.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model Order Reduction Algorithm for Estimating the Absorption Spectrum

The ab initio description of the spectral interior of the absorption spectrum poses both a theoretical and computational challenge for modern electronic structure theory. Due to the often spectrally dense character of this domain in the quantum propagator’s eigenspectrum for medium-to-large sized systems, traditional approaches based on the partial diagonalization of the propagator often encounter oscillatory and stagnating convergence. Electronic structure methods which solve the molecular response problem through the solution of spectrally shifted linear systems, such as the complex polarization propagator, offer an alternative approach which is agnostic to the underlying spectral density or domain location. This generality comes at a seemingly high computational cost associated with solving a large linear system for each spectral shift in some discretization of the spectral domain of interest. In this work, we present a novel, adaptive solution to this high computational overhead based on model order reduction techniques via interpolation. Model order reduction reduces the computational complexity of mathematical models and is ubiquitous in the simulation of dynamical systems and control theory. The efficiency and effectiveness of the proposed algorithm in the ab initio prediction of X-ray absorption spectra is demonstrated using a test set of challenging water clusters which are spectrally dense in the neighborhood of the oxygen K-edge. On the basis of a single, user defined tolerance we automatically determine the order of the reduced models and approximate the absorption spectrum up to the given tolerance. We also illustrate that, for the systems studied, the automatically determined model order increases logarithmically with the problem dimension, compared to a linear increase of the number of eigenvalues within the energy window. Furthermore, we observed that the computational cost of the proposed algorithm only scales quadratically with respect to the problem dimension.

IDREAM, K-Edge, theoretical, computational, electr↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming

Purpose: Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation in chest radiographs. Methods: A two stage method is proposed to segment the cavity borders, given a user defined seed point close to the center of the cavity. First, a supervised learning approach is employed to train a pixel classifier using texture and radial features to identify the border pixels of the cavity. A likelihood value of belonging to the cavity border is assigned to each pixel by the classifier. The authors experimented with four different classifiers:k-nearest neighbor (kNN), linear discriminant analysis (LDA), GentleBoost (GB), and random forest (RF). Next, the constructed likelihood map was used as an input cost image in the polar transformed image space for dynamic programming to trace the optimal maximum cost path. This constructed path corresponds to the segmented cavity contour in image space. Results: The method was evaluated on 100 chest radiographs (CXRs) containing 126 cavities. The reference segmentation was manually delineated by an experienced chest radiologist. An independent observer (a chest radiologist) also delineated all cavities to estimate interobserver variability. Jaccard overlap measure Ω was computed between the reference segmentation and the automatic segmentation; and between the reference segmentation and the independent observer's segmentation for all cavities. A median overlap Ω of 0.81 (0.76 ± 0.16), and 0.85 (0.82 ± 0.11) was achieved between the reference segmentation and the automatic segmentation, and between the segmentations by the two radiologists, respectively. The best reported mean contour distance and Hausdorff distance between the reference and the automatic segmentation were, respectively, 2.48 ± 2.19 and 8.32 ± 5.66 mm, whereas these distances were 1.66 ± 1.29 and 5.75 ± 4.88 mm between the segmentations by the reference reader and the independent observer, respectively. The automatic segmentations were also visually assessed by two trained CXR readers as “excellent,” “adequate,” or “insufficient.” The readers had good agreement in assessing the cavity outlines and 84% of the segmentations were rated as “excellent” or “adequate” by both readers. Conclusions: The proposed cavity segmentation technique produced results with a good degree of overlap with manual expert segmentations. The evaluation measures demonstrated that the results approached the results of the experienced chest radiologists, in terms of overlap measure and contour distance measures. Automatic cavity segmentation can be employed in TB clinics for treatment monitoring, especially in resource limited settings where radiologists are not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-05: Development and Clinical Introduction of Automated Radiotherapy Treatment Planning for Prostate Cancer

Purpose: To develop an automated radiotherapy treatment planning and optimization workflow for prostate cancer in order to generate clinical treatment plans. Methods: A fully automated radiotherapy treatment planning and optimization workflow was developed based on the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). To evaluate our method, a retrospective planning study (n=100) was performed on patients treated for prostate cancer with 5 field intensity modulated radiotherapy, receiving a dose of 35×2Gy to the prostate and vesicles and a simultaneous integrated boost of 35×0.2Gy to the prostate only. A comparison was made between the dosimetric values of the automatically and manually generated plans. Operator time to generate a plan and plan efficiency was measured. Results: A comparison of the dosimetric values show that automatically generated plans yield more beneficial dosimetric values. In automatic plans reductions of 43% in the V72Gy of the rectum and 13% in the V72Gy of the bladder are observed when compared to the manually generated plans. Smaller variance in dosimetric values is seen, i.e. the intra- and interplanner variability is decreased. For 97% of the automatically generated plans and 86% of the clinical plans all criteria for target coverage and organs at risk constraints are met. The amount of plan segments and monitor units is reduced by 13% and 9% respectively. Automated planning requires less than one minute of operator time compared to over an hour for manual planning. Conclusion: The automatically generated plans are highly suitable for clinical use. The plans have less variance and a large gain in time efficiency has been achieved. Currently, a pilot study is performed, comparing the preference of the clinician and clinical physicist for the automatic versus manual plan. Future work will include expanding our automated treatment planning method to other tumor sites and develop other automated radiotherapy workflows.

60 APPLIED LIFE SCIENCES↗

Charging Decision Making for Automated Electric Vehicles

Abstract: Overview/Significance With the emerging of autonomous driving and its application in electric vehicles, the charging decision making should be taken over by the vehicles. Autonomous electric vehicles will require the capability to make charging decisions according to the battery energy state, the travel demand and also the available charging infrastructure. The introduction of autonomous driving technology would remove the challenge of co-locating charging infrastructure with driver destinations and presents a driver-free method for EVs to reach nearby charging stations. This will significantly change the charging behavior of electric vehicles. EV driver will no longer need to be present at charging stations for charging actions. Automated EVs can drive to nearby charging stations to perform charging actions by themselves when necessary. Meanwhile, connected vehicles technology makes electric vehicles have the capability to sense and obtain pertinent information from nearby charging station networks and then calculate the corresponding costs and availability for charging. All these promising capabilities bring new opportunities to construct an automatic charging decision making system and improve energy efficiency of charging actions for automatic electric vehicles. Abstract: Methodology This research introduces optimization tools and case studies on charging decision making for automated electric vehicles under personal usage scenario. The designed optimization tools aim to provide charging strategies, i.e. the optimal choice of charging station outside home and the amount of charged energy, by considering constraints from personal daily itineraries and existing charging infrastructure. Abundant real world EV data is utilized to construct stochastic energy consumption prediction model under realistic driving conditions. Advanced dynamic programming technology is utilized to model and solve the potential multi-stage decision making process by considering realistic uncertainties of EV energy cost and dynamics of itinerary information. Large-scale simulation studies using Chicago itinerary data are demonstrated to illustrate energy benefits from automatic charging decision making for future autonomous EVs. Abstract: Results/Conclusions Optimal automatic charging decision making and its energy benefits have been studied for personal automated electric vehicles. A data-driven method based on large amount of real-world data and the corresponding real-time update algorithm have been proposed to construct multi-channel stochastic energy consumption prediction model. Based on the energy cost prediction, dynamic multi-stage charging decision-making models are established for optimal strategies during a daily itinerary. Derived charging strategies can minimize the monetary and energy cost of charging actions for autonomous vehicles. Simulations and case studies show the potential ability of autonomous electric vehicles to reduce the range anxiety and charging infrastructure dependency. Automatic charging decision making can mitigate the pain from electric vehicle charging necessity outside home. In conclusion, automated electric vehicles equipped with an appropriate automatic charging decision making system will help EV driver to relieve from heavy time cost of recharging, reduce the energy cost of performing charging actions and improve the energy efficiency in future electrified transportation system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Spine, Carina, and Tumor as Registration Landmarks for Volumetric Image-Guided Lung Radiotherapy

Purpose: To assess the feasibility, reproducibility, and accuracy of volumetric lung image guidance using different thoracic landmarks for image registration. Methods and Materials: In 30 lung patients, four independent observers conducted automated and manual image registrations on Day 1 cone-beam computed tomography data sets using the spine, carina, and tumor (720 image registrations). The image registration was timed, and the couch displacements were recorded. The intraclass correlation was used to assess reproducibility, and the Bland-Altman analysis was used to compare the automatic and manual matching methods. Tumor coverage (accuracy) was assessed through grading the tumor position after image matching against the internal target volume and planning target volume. Results: The image-guided process took an average of 1 min for all techniques, with the exception of manual tumor matching, which took 4 min. Reproducibility was greatest for automatic carina matching (intraclass correlation, 0.90-0.93) and lowest for manual tumor matching (intraclass correlation, 0.07-0.43) in the left-right, superoinferior, and anteroposterior directions, respectively. The Bland-Altman analysis showed no significant difference between the automatic and manual registration methods. The tumor was within the internal target volume 62% and 60% of the time and was outside the internal target volume, but within the planning target volume, 38% and 40% of the time after automatic spine and automatic carina matching, respectively. Conclusion: For advanced lung cancer, the spine or carina can be used equally for cone-beam computed tomography image registration without compromising target coverage. The carina was more reproducible than the spine, but additional analysis is required to confirm its validation as a tumor surrogate. Soft-tissue registration is unsuitable at present, given the limitations in contrast resolution and the high interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BigNeuron: a resource to benchmark and predict performance of algorithms for automated tracing of neurons in light microscopy datasets

BigNeuron is an open community bench-testing platform with the goal of setting open standards for accurate and fast automatic neuron tracing. We gathered a diverse set of image volumes across several species that is representative of the data obtained in many neuroscience laboratories interested in neuron tracing. Here, we report generated gold standard manual annotations for a subset of the available imaging datasets and quantified tracing quality for 35 automatic tracing algorithms. The goal of generating such a hand-curated diverse dataset is to advance the development of tracing algorithms and enable generalizable benchmarking. Together with image quality features, we pooled the data in an interactive web application that enables users and developers to perform principal component analysis, t-distributed stochastic neighbor embedding, correlation and clustering, visualization of imaging and tracing data, and benchmarking of automatic tracing algorithms in user-defined data subsets. The image quality metrics explain most of the variance in the data, followed by neuromorphological features related to neuron size. Furthermore, we observed that diverse algorithms can provide complementary information to obtain accurate results and developed a method to iteratively combine methods and generate consensus reconstructions. The consensus trees obtained provide estimates of the neuron structure ground truth that typically outperform single algorithms in noisy datasets. However, specific algorithms may outperform the consensus tree strategy in specific imaging conditions. Finally, to aid users in predicting the most accurate automatic tracing results without manual annotations for comparison, we used support vector machine regression to predict reconstruction quality given an image volume and a set of automatic tracings.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-48: Automated Quality Assurance for XML Controlled Linacs

Purpose: To automate routine imaging QA procedures so that complying with TG 142 and TG 179 can be efficient and reliable. Methods: Two QA tests for a True Beam Linac were automatized. A Winston Lutz test as described by Lutz et al{sup 1} using the Winston Lutz test kit from BrainLab, Germany and a CBCT Image Quality test as described in TG 179 using the EMMA phantom, Siemens Medical Physics, Germany were performed in our True Beam. For each QA procedure tested, a 3 step paradigm was used. First, the data was automatically acquired using True Beam Developer Mode and XML scripting. Second, the data acquired in the first step was automatically processed using in-home grown Matlab GUIs. Third, Machine Learning algorithms were used to automatically classify the processed data and reports generated. Results: The Winston Luzt test could be performed by an experienced medical physicist in 29.0 ± 8.0 min. The same test, if automated using our paradigm, could be performed in 3.0 ± 0.1 min. In the same lieu, time could be substantially saved for image quality tests. In this case, the amount of time saved will depend on the phantoms used and the initial localization method. Additionally, machine learning algorithms could automatically identify the roots of the problems if any and possibly help reduce machine down time. Conclusion: Modern linear accelerators are equipped with advanced 2D and 3D imaging that are used for patient alignment substantially improving IGRT protocols. However, this extra complexity exponentially increases the number of QA tests needed. Using the new paradigm described above, not only bare minimum but best practice QA programs could be implemented with the same manpower. This work is supported by Varian, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-373: A Motorized Stage for Fast and Accurate QA of Machine Isocenter

Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-497: Semi-Automated in Vivo Radiochromic Film Dosimetry Using a Novel Image Processing Algorithm

Purpose: To validate an automated image processing algorithm designed to detect the center of radiochromic film used for in vivo film dosimetry against the current gold standard of manual selection. Methods: An image processing algorithm was developed to automatically select the region of interest (ROI) in *.tiff images that contain multiple pieces of radiochromic film (0.5x1.3cm{sup 2}). After a user has linked a calibration file to the processing algorithm and selected a *.tiff file for processing, an ROI is automatically detected for all films by a combination of thresholding and erosion, which removes edges and any additional markings for orientation. Calibration is applied to the mean pixel values from the ROIs and a *.tiff image is output displaying the original image with an overlay of the ROIs and the measured doses. Validation of the algorithm was determined by comparing in vivo dose determined using the current gold standard (manually drawn ROIs) versus automated ROIs for n=420 scanned films. Bland-Altman analysis, paired t-test, and linear regression were performed to demonstrate agreement between the processes. Results: The measured doses ranged from 0.2-886.6cGy. Bland-Altman analysis of the two techniques (automatic minus manual) revealed a bias of -0.28cGy and a 95% confidence interval of (5.5cGy,-6.1cGy). These values demonstrate excellent agreement between the two techniques. Paired t-test results showed no statistical differences between the two techniques, p=0.98. Linear regression with a forced zero intercept demonstrated that Automatic=0.997*Manual, with a Pearson correlation coefficient of 0.999. The minimal differences between the two techniques may be explained by the fact that the hand drawn ROIs were not identical to the automatically selected ones. The average processing time was 6.7seconds in Matlab on an IntelCore2Duo processor. Conclusion: An automated image processing algorithm has been developed and validated, which will help minimize user interaction and processing time of radiochromic film used for in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-423: Automating Treatment Planning for Cervical Cancer in Low- and Middle- Income Countries

Purpose: To develop and test two independent algorithms that automatically create the photon treatment fields for a four-field box beam arrangement, a common treatment technique for cervical cancer in low- and middle-income countries. Methods: Two algorithms were developed and integrated into Eclipse using its Advanced Programming Interface:3D Method: We automatically segment bony anatomy on CT using an in-house multi-atlas contouring tool and project the structures into the beam’s-eye-view. We identify anatomical landmarks on the projections to define the field apertures. 2D Method: We generate DRRs for all four beams. An atlas of DRRs for six standard patients with corresponding field apertures are deformably registered to the test patient DRRs. The set of deformed atlas apertures are fitted to an expected shape to define the final apertures. Both algorithms were tested on 39 patient CTs, and the resulting treatment fields were scored by a radiation oncologist. We also investigated the feasibility of using one algorithm as an independent check of the other algorithm. Results: 96% of the 3D-Method-generated fields and 79% of the 2D-method-generated fields were scored acceptable for treatment (“Per Protocol” or “Acceptable Variation”). The 3D Method generated more fields scored “Per Protocol” than the 2D Method (62% versus 17%). The 4% of the 3D-Method-generated fields that were scored “Unacceptable Deviation” were all due to an improper L5 vertebra contour resulting in an unacceptable superior jaw position. When these same patients were planned with the 2D method, the superior jaw was acceptable, suggesting that the 2D method can be used to independently check the 3D method. Conclusion: Our results show that our 3D Method is feasible for automatically generating cervical treatment fields. Furthermore, the 2D Method can serve as an automatic, independent check of the automatically-generated treatment fields. These algorithms will be implemented for fully automated cervical treatment planning.

60 APPLIED LIFE SCIENCES↗

QGLab v0.0.1

A software program for experimenting with holographic teleportation protocol on quantum computers. The code implements the protocol that was proposed in https://arxiv.org/abs/1911.06314. The code is an end-to-end software solution that facilitates conducting the holographic teleportation experiments on state-of-the-art and emergent generations of QPUs supported by the Qiskit and tket SDKs. The code bundles all stages of an experiment as a single configurable workflow allowing faster development and experimentation cycles. Features: 1. Easy switching between Qiskit and tket quantum compilers. 2. Semi-automatic facilities for finding optimal compilation solutions beyond what Qiskit and tket provide by default. 3. Experiment resolution scaling (based on automatic jobs' batching). 4. Automatic experiment scaling over qubits. 5. Automatic readout error mitigation. 6. Automatic reproducibility analysis. 7. Standalone error-mitigation tools (randomized compiling, mitigation with estimation circuits, zero-noise extrapolation)

Shapoval, Illya↗

Dynamic Tuning of Seismic Signal Detector Trigger Levels for Local Networks

The quality of automatic signal detections from sensor networks depends on individual detector trigger levels (TLs) from each sensor. The largely manual process of identifying effective TLs is painstaking and does not guarantee optimal configuration settings, yet achieving superior automatic detection of signals and ultimately, events, is closely related to these parameters. In this paper, we present a Dynamic Detector Tuning (DDT) system that automatically adjusts effective TL settings for signal detectors to the current state of the environment by leveraging cooperation within a local neighborhood of network sensors. After a stabilization period, the DDT algorithm can adapt in near-real time to changing conditions and automatically tune a signal detector to identify (detect) signals from only events of interest. Our current work focuses on reducing false signal detections early in the seismic signal processing pipeline, which leads to fewer false events and has a significant impact on reducing analyst time and effort. This system provides an important new method to automatically tune detector TLs for a network of sensors and is applicable to both existing sensor performance boosting and new sensor deployment. Finally, with ground truth on detections from a local neighborhood of seismic sensors within a network monitoring the Mount Erebus volcano in Antarctica, we show that DDT reduces the number of false detections by 18% and the number of missed detections by 11% when compared with optimal fixed TLs for all sensors.

58 GEOSCIENCES↗