Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADULTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Radiation dose from cigarette tobacco

The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as {sup 226}Ra and {sup 210}Pb of the uranium series and {sup 228}Ra of the thorium series and/or man-made produced radionuclides, such as {sup 137}Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for {sup 226}Ra varied from 42.5 to 178.6 {mu}Sv y{sup -1} (average 79.7 {mu}Sv y{sup -1}), while for {sup 228}Ra from 19.3 to 116.0 {mu}Sv y{sup -1} (average 67.1 {mu}Sv y{sup -1}) and for {sup 210}Pb from 47.0 to 134.9 {mu}Sv y{sup -1} (average 104.7 {mu}Sv y{sup -1}), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 {mu}Sv y{sup -1} (average 251.5 {mu}Sv y{sup -1}). The annual effective dose from {sup 137}Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 nSv y{sup -1} (average 199.3 nSv y{sup -1})

61 RADIATION PROTECTION AND DOSIMETRY↗

Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues--Preliminary Results

Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo and in vitro toxicological effects of titanium dioxide nanoparticles on small intestine

In European Union, titanium dioxide (TiO{sub 2}) as bulk material is a food additive (E171) and - as nanoparticle (NP) - is used as a white pigment in several products (e.g. food, cosmetics, drugs). E171 contains approximately 36% of particles less than 100 nm in at least one dimension and TiO{sub 2} NP exposure is estimated fairly below 2.5 mg/person/day. The gastrointestinal tract is a route of entry for NPs, thus representing a potential target of effects. In in vivo study, the effects of TiO{sub 2} NP in adult rat small intestine have been evaluated by oral administration of 0 (CTRL), 1 and 2 mg/kg body weight per day - relevant to human dietary intake. Detailed quali/quantitative histopathological analyses were performed on CTRL and treated rat samples. Scanning electron microscopy (SEM) analysis was performed on small intestine. An in vitro study on Caco-2 cells was also used in order to evaluate the potential cytotoxic effects directly on enterocytes through the lactate dehydrogenase (LDH) assay. Suspensions of TiO{sub 2} NPs for in vitro and in vivo study were characterized by EM. Histomorphometrical data showed treatment-related changes of villus height and widths in male rats. Significantly different from CTRL decreased LDH levels in the medium were detected in vitro at 24h with 2.5, 5, 10 and 20 µg/cm{sup 2} levels of TiO{sub 2} NPs. SEM analysis showed no damaged areas. Overall the results showed that enterocytes may represent a target of TiO{sub 2} NP toxicity by direct exposure both in vivo and in vitro models.

60 APPLIED LIFE SCIENCES↗

New maxillofacial infrared detection technologies

At the dental clinic the infrared range radiation spectrum of tissues was used to study the dynamics of local temperature and structure of the skin, subcutaneous fat, and other tissues of the maxillofacial area in adult healthy volunteers and patients. In particular, we studied the dynamics of local temperature of mucous membranes of the mouth, teeth, and places in the mouth and dental structures in the norm and in various pathological conditions of the lips, gums, teeth, tongue, palate, and cheeks before, during and after chewing food, drinking water, medication, and inhalation of air. High safety and informational content of infrared thermography are prospective for the development of diagnostics in medicine. We have 3 new methods for infrared detection protected by patents in Russia.

60 APPLIED LIFE SCIENCES↗

Radiological dosimetry measurements in Costa Rica

The main cause of human exposure to artificial radiation corresponds to medical applications, so it is essential to reduce the dose to patients, workers and consequently the entire population [1]. Although there is no dose limit for patients, is necessary to reduce it to a minimum possible while still getting all the necessary diagnostic information, taking economic and social factors into account [2]. Based on this proposal, agencies such as the International Atomic Energy Agency has been dedicated to providing guidelines levels, whose function is to serve as standards for the optimization of the medical exposure [3]. This research was created as a preliminary survey with the claim of eventually determine the guidance levels in Costa Rica for three different studies of general radiology: Lumbar Spine-AP, Chest - PA and Thoracic Spine - AP (for screens with speeds of 400 and 800), and cranio-caudal study in mammography, applied to Costa Rica’s adult population, perform properly in the institutions of Caja Costarricense del Seguro Social (CCSS).

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing a model human gut microbiota composed of members of its two dominant bacterial phyla

The adult human distal gut microbial community is typically dominated by 2 bacterial phyla (divisions), the Firmicutes and the Bacteroidetes. Little is known about the factors that govern the interactions between their members. Here, we examine the niches of representatives of both phyla in vivo. Finished genome sequences were generated from Eubacterium rectale and E. eligens, which belong to Clostridium Cluster XIVa, one of the most common gut Firmicute clades. Comparison of these and 25 other gut Firmicutes and Bacteroidetes indicated that the Firmicutes possess smaller genomes and a disproportionately smaller number of glycan-degrading enzymes. Germ-free mice were then colonized with E. rectale and/or a prominent human gut Bacteroidetes, Bacteroides thetaiotaomicron, followed by whole-genome transcriptional profiling, high-resolution proteomic analysis, and biochemical assays of microbial microbial and microbial host interactions. B. thetaiotaomicron adapts to E. rectale by up-regulating expression of a variety of polysaccharide utilization loci encoding numerous glycoside hydrolases, and by signaling the host to produce mucosal glycans that it, but not E. rectale, can access. E. rectale adapts to B. thetaiotaomicron by decreasing production of its glycan-degrading enzymes, increasing expression of selected amino acid and sugar transporters, and facilitating glycolysis by reducing levels of NADH, in part via generation of butyrate from acetate, which in turn is used by the gut epithelium. This simplified model of the human gut microbiota illustrates niche specialization and functional redundancy within members of its major bacterial phyla, and the importance of host glycans as a nutrient foundation that ensures ecosystem stability.

59 BASIC BIOLOGICAL SCIENCES↗

Small animal simultaneous PET/MRI: initial experiences in a 9.4T microMRI

We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 3, Results, Variability, and Uncertainty

This paper is part three of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. The radionuclides of interest are the 238U series (14 nuclides), the actinium series (headed by 235U; 11 nuclides), and the 232Th series (11 nuclides); primordial radionuclides 87Rb and 40K; cosmogenic and fallout radionuclides 14C and 3H; and purely anthropogenic radionuclides 137Cs-137mBa, 129I and 90Sr-90Y. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Part two described the methods used to organize the data collected in part one and segregate it into the ages and genders defined by the study, imputed missing values from the existing data, apportioned activity in bone, and imputed activity in hollow organ contents and the remainder of the body. This paper estimates equivalent doses to target tissues from source regions and maps target tissues to lists of tissues with International Commission on Radiation Protection (ICRP) tissue-weighting factors or to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue-weighting factors recommended in 1977, 1990, and 2007, are then calculated, and an upper bound of variability of the effective dose is estimated by calculating the average coefficients of variation (CV), assuming all variance is due to variability. Most of the data were for adult males, whose average annual effective dose is estimated to be 337 μSv (CV = 0.65, geometric mean = 283 μSv, geometric standard deviation sG = 1.81) using 2007 ICRP tissue-weighting factors. This result is between the National Council on Radiation Protection & Measurements’ 1987 estimate of 390 μSv (using 1977 wTs) and its 2009 estimate of 285 μSv (using 2007 wTs) and is higher than the United Nations Scientific Committee on the Effects of Atomic Radiation’s 2000 estimate of 310 μSv (using 1990 wTs). The methods and software developed for this project are sufficiently detailed and sufficiently general to be usable with autopsy data from any or all countries.

59 BASIC BIOLOGICAL SCIENCES↗

RECONSTRUCTION OF LONG-LIVED RADIONUCLIDE INTAKES FOR TECHA RIVERSIDE RESIDENTS: STRONTIUM-90

Releases of radioactive materials from the Mayak Production Association in 1949-1956 resulted in contamination of the Techa River; a nuclide of major interest was 90Sr, which downstream residents consumed with water from the river and with milk contaminated by cow's consumption of river water and contaminated pasture. Over the years, several reconstructions of dose have been performed for the approximately 30,000 persons who make up the Extended Techa River Cohort. The purpose of the study described here was to derive a revised reference-90Sr-intake function for the members of this cohort. The revision was necessary because recently discovered data have provided a more accurate description of the time course of the releases, and more is now known about the importance of the pasture grass-cow-milk pathway for the members of this cohort. The fundamental basis for the derivation of the reference-90Sr-intake function remains the same: thousands of measurements of 90Sr content in bone with a special whole-body counter, thousands of measurement of beta-activity of front teeth with a special tooth-beta counter, and a variety of other measurements, including post mortem measurements of 90Sr in bone, measurements of 90Sr in cow's milk, and measurements of beta activity in human excreta. Results of the new analyses are that the major intake started in September 1950 and peaked somewhat later than originally postulated. However, the total intake for adult residents has not changed significantly. For children of some birth years, the intake and incorporation of 90Sr in bone tissue have changed substantially.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron radiation analysis of possible correlations between metal status in human cementum and periodontal disease

Periodontitis is a serious disease that affects up to 50% of an adult population. It is a chronic condition involving inflammation of the periodontal ligament and associated tissues leading to eventual tooth loss. Some evidence suggests that trace metals, especially zinc and copper, may be involved in the onset and severity of periodontitis. Thus we have used synchrotron X-ray fluorescence imaging on cross sections of diseased and healthy teeth using a microbeam to explore the distribution of trace metals in cementum and adhering plaque. The comparison between diseased and healthy teeth indicates that there are elevated levels of zinc, copper and nickel in diseased teeth as opposed to healthy teeth. This preliminary correlation between elevated levels of trace metals in the cementum and plaque of diseased teeth suggests that metals may play a role in the progress of periodontitis.

60 APPLIED LIFE SCIENCES↗

Structure determination and analysis of a haemolytic gingipain adhesin domain from Porphyromonas gingivalis

Porphyromonas gingivalis is an obligately anaerobic bacterium recognized as an aetiological agent of adult periodontitis. P. gingivalis produces cysteine proteinases, the gingipains. The crystal structure of a domain within the haemagglutinin region of the lysine gingipain (Kgp) is reported here. The domain was named K2 as it is the second of three homologous structural modules in Kgp. The K2 domain structure is a 'jelly-roll' fold with two anti-parallel {beta}-sheets. This fold topology is shared with adhesive domains from functionally diverse receptors such as MAM domains, ephrin receptor ligand binding domains and a number of carbohydrate binding modules. Possible functions of K2 were investigated. K2 induced haemolysis of erythrocytes in a dose-dependent manner that was augmented by the blocking of anion transport. Further, cysteine-activated arginine gingipain RgpB, which degrades glycophorin A, sensitized erythrocytes to the haemolytic effect of K2. Cleaved K2, similar to that found in extracted Kgp, lacks the haemolytic activity indicating that autolysis of Kgp may be a staged process which is artificially enhanced by extraction of the protein. The data indicate a functional role for K2 in the integrated capacity conferred by Kgp to enable the porphyrin auxotroph P. gingivalis to capture essential haem from erythrocytes.

36 MATERIALS SCIENCE↗

In-patient to isocenter KERMA ratios in CT

Purpose: To estimate in-patient KERMA for specific organs in computed tomography (CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom.Method: A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma K{sub CT} at the CT scanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (R{sub K}) as K/ K{sub CT}, which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). R{sub K} values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CT dosimetry. CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV. Results: At 120 kV, median R{sub K} values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile R{sub K} values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile R{sub K} values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average R{sub K} for the 25 Rando organs at 120 kV was 0.61 {+-} 0.08. Average R{sub K} values in the head, chest, and abdomen showed little variation. Relative to R{sub K} values in the head, chest, and abdomen obtained at 120 kV, R{sub K} values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average R{sub K} values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in R{sub K} value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average R{sub K} value by 9%. Conclusions: In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organ doses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissue dose would require the use of energy-appropriate conversion factors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of respiratory motion on internal radiation dosimetry

Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences the absorbed dose for external exposure to radiation. However, to their knowledge, the effect of respiratory motion on internal radiation dosimetry has never been reported before. Methods: Thirteen computational models representing the adult male at different respiratory phases corresponding to the normal respiratory cycle were generated from the 4D dynamic XCAT phantom. Monte Carlo calculations were performed using the MCNP transport code to estimate the specific absorbed fractions (SAFs) of monoenergetic photons/electrons, the S-values of common positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124), and the absorbed dose of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) in 28 target regions for both the static (average of dynamic frames) and dynamic phantoms. Results: The self-absorbed dose for most organs/tissues is only slightly influenced by respiratory motion. However, for the lung, the self-absorbed SAF is about 11.5% higher at the peak exhale phase than the peak inhale phase for photon energies above 50 keV. The cross-absorbed dose is obviously affected by respiratory motion for many combinations of source-target pairs. The cross-absorbed S-values for the heart contents irradiating the lung are about 7.5% higher in the peak exhale phase than the peak inhale phase for different positron-emitting radionuclides. For {sup 18}F-FDG, organ absorbed doses are less influenced by respiratory motion. Conclusions: Respiration-induced volume variations of the lungs and the repositioning of internal organs affect the self-absorbed dose of the lungs and cross-absorbed dose between organs in internal radiation dosimetry. The dynamic anatomical model provides more accurate internal radiation dosimetry estimates for the lungs and abdominal organs based on realistic modeling of respiratory motion. This work also contributes to a better understanding of model-induced uncertainties in internal radiation dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impaired Organization and Function of Myofilaments in Single Muscle Fibers from a Mouse Model of Pompe Disease

Pompe disease, a deficiency of lysosomal acid {alpha}-glucosidase, is a disorder of glycogen metabolism that can affect infants, children, or adults. In all forms of the disease, there is progressive muscle pathology leading to premature death. The pathology is characterized by accumulation of glycogen in lysosomes, autophagic buildup, and muscle atrophy. The purpose of the present investigation was to determine if myofibrillar dysfunction in Pompe disease contributes to muscle weakness beyond that attributed to atrophy. The study was performed on isolated myofibers dissected from severely affected fast glycolytic muscle in the {alpha}-glucosidase knockout mouse model. Psoas muscle fibers were first permeabilized, so that the contractile proteins could be directly relaxed or activated by control of the composition of the bathing solution. When normalized by cross-sectional area, single fibers from knockout mice produced 6.3 N/cm{sup 2} of maximum Ca{sup 2+}-activated tension compared with 12.0 N/cm{sup 2} produced by wild-type fibers. The total protein concentration was slightly higher in the knockout mice, but concentrations of the contractile proteins myosin and actin remained unchanged. Structurally, X-ray diffraction showed that the actin and myosin filaments, normally arranged in hexagonal arrays, were disordered in the knockout muscle, and a lower fraction of myosin cross bridges was near the actin filaments in the relaxed muscle. The results are consistent with a disruption of actin and myosin interactions in the knockout muscles, demonstrating that impaired myofibrillar function contributes to weakness in the diseased muscle fibers.

59 BASIC BIOLOGICAL SCIENCES↗

A combinatorial model for dentate gyrus sparse coding

The dentate gyrus forms a critical link between the entorhinal cortex and CA3 by providing a sparse version of the signal. Concurrent with this increase in sparsity, a widely accepted theory suggests the dentate gyrus performs pattern separation—similar inputs yield decorrelated outputs. Although an active region of study and theory, few logically rigorous arguments detail the dentate gyrus’s (DG) coding. We suggest a theoretically tractable, combinatorial model for this action. The model provides formal methods for a highly redundant, arbitrarily sparse, and decorrelated output signal.To explore the value of this model framework, we assess how suitable it is for two notable aspects of DG coding: how it can handle the highly structured grid cell representation in the input entorhinal cortex region and the presence of adult neurogenesis, which has been proposed to produce a heterogeneous code in the DG. We find tailoring the model to grid cell input yields expansion parameters consistent with the literature. In addition, the heterogeneous coding reflects activity gradation observed experimentally. Lastly, we connect this approach with more conventional binary threshold neural circuit models via a formal embedding.

60 APPLIED LIFE SCIENCES↗

Why Travel for Complex Cancer Surgery? Americans React to ‘Brand-Sharing’ Between Specialty Cancer Hospitals and Their Affiliates

Introduction: Leading cancer hospitals have increasingly shared their ‘brand’ with smaller hospitals through affiliations. Because each brand evokes a distinct reputation for the care provided, ‘brand-sharing’ has the potential to impact the public’s ability to differentiate the safety and quality within hospital networks. The general public was surveyed to determine the perceived similarities and differences in the safety and quality of complex cancer surgery performed at top cancer hospitals and their smaller affiliate hospitals. Methods: A national, web-based KnowledgePanel (GfK) survey of American adults was conducted. Respondents were asked about their beliefs regarding the quality and safety of complex cancer surgery at a large, top-ranked cancer hospital and a smaller, local hospital, both in the presence and absence of an affiliation between the hospitals. Results: A total of 1010 surveys were completed (58.1% response rate). Overall, 85% of respondents felt ‘motivated’ to travel an hour for complex surgery at a larger hospital specializing in cancer, over a smaller local hospital. However, if the smaller hospital was affiliated with a top-ranked cancer hospital, 31% of the motivated respondents changed their preference to the smaller hospital. When asked to compare leading cancer hospitals and their smaller affiliates, 47% of respondents felt that surgical safety, 66% felt guideline compliance, and 53% felt cure rates would be the same at both hospitals. Conclusions: Approximately half of surveyed Americans did not distinguish the quality and safety of surgical care at top-ranked cancer hospitals from their smaller affiliates, potentially decreasing their motivation to travel to top centers for complex surgical care.

60 APPLIED LIFE SCIENCES↗