Study of Unmanned Systems to Evaluate the Martian Environment. Volume IV - Summary
Unmanned space mission to determine Martian environmental factors influencing design of systems for manned space mission to Mars - summary report
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Unmanned space mission to determine Martian environmental factors influencing design of systems for manned space mission to Mars - summary report
A program was conducted to determine the merit of a combined structure/thermal meteoroid protection system for a cryogenic vehicle propulsion module. Structural concepts were evaluated to identify least weight designs. Thermal analyses determined optimum tank arrangements and insulation materials. Meteoroid penetration experiments provided data for design of protection systems. Preliminary designs were made and compared on the basis of payload capability. Thermal performance tests demonstrated heat transfer rates typical for the selected design. Meteoroid impact tests verified the protection characteristics. A mockup was made to demonstrate protection system installation. The best design found combined multilayer insulation with a truss structure vehicle body. The multilayer served as the thermal/meteoroid protection system.
A marketing study to determine the acceptance and utilization of a STOL aircraft short-haul air transportation system was conducted. The relationship between STOL characteristics and the economic and social viability of STOL as a short-haul reliever system was examined. A study flow chart was prepared to show the city pair and traffic split analysis. The national demand for STOL aircraft, as well as the foreign and military markets, were analyzed.
In the study to determine the role of man in Sortie Lab operations, a functional model of a generalized experiment system was developed. The results are presented of a requirements analysis which was conducted to identify performance requirements, information requirements, and interface requirements associated with each function in the model.
A study was conducted to determine the functional requirements for onboard management of space shuttle consumables. A generalized consumable management concept was developed for application to advanced spacecraft. The subsystems and related consumables selected for inclusion in the consumables management system are: (1) propulsion, (2) power generation, and (3) environmental and life support.
The state of the art determination was made for radar measurement of: soil moisture, snow, standing and flowing water, lake and river ice, determination of required spacecraft radar parameters, study of synthetic-aperture radar systems to meet these parametric requirements, and study of techniques for on-board processing of the radar data. Significant new concepts developed include the following: scanning synthetic-aperture radar to achieve wide-swath coverage; single-sideband radar; and comb-filter range-sequential, range-offset SAR processing. The state of the art in radar measurement of water resources parameters is outlined. The feasibility for immediate development of a spacecraft water resources SAR was established. Numerous candidates for the on-board processor were examined.
Several engine concepts examined to determine a preferred design which most effectively exploits the characteristics of hydrogen fuel in aircraft tanks received major emphasis. Many candidate designs of tank structure and cryogenic insulation systems were evaluated. Designs of all major elements of the aircraft fuel system including pumps, lines, valves, regulators, and heat exchangers received attention. Selected designs of boost pumps to be mounted in the LH2 tanks, and of a high pressure pump to be mounted on the engine were defined. A final design of LH2-fueled transport aircraft was established which incorporates a preferred design of fuel system. That aircraft was then compared with a conventionally fueled counterpart designed to equivalent technology standards.
Purpose: This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Methods: Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Results: Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ − 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Conclusion: Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.∑σ.
Ti-5Al-5Mo-5V-3Cr (Ti-5553) is a metastable beta titanium alloy with high hardenability, good ductility, and high strength. Different microstructures with different volume fractions and distribution of α phase can be produced in this alloy by suitable heat treatment. In this study, the workability of this alloy has been determined as a function of the volume fraction of α phase in the microstructure. Workability is an important parameter indicating the ability of the material to be deformed without the occurrence of fracture. Specimens with three different volume fractions of alpha phase were produced using suitable heat treatments. Two different volume fractions of α (approx 3 and 23%) were obtained by air and furnace cooling, respectively, after solutionizing at 877 °C, i.e., 25 °C above the beta transus temperature. The third specimen with approximately 18% volume fraction of α was obtained by solutionizing at 800 °C for 4 h, followed by water quenching. Workability was investigated by conducting upsetting tests on cylindrical specimens with varying height-to-diameter ratios. Workability limit diagrams have been obtained as a function of axial and hoop strains at fracture. The workability for the furnace cooled specimens was found to be very poor compared to the other two specimens. The results were evaluated using four popular ductile fracture criteria, and the values of critical damage constants at fracture initiation have been calculated using the experimental upsetting test data. The theoretical fracture strains were estimated using the critical constants obtained for all the four ductile fracture criteria and were compared with experimental test data. The Cockroft and Latham, Brozzo et al., and Oh et al. showed close agreement with the experimental values and therefore can be used as ductile fracture criteria for this alloy.
Purpose: The seed implant technique at our institution involves using a published nomogram for seed ordering based on CT based volume studies of the prostate. Ultrasound volume studies are subsequently used in the operating room for planning a modified peripheral loading with urethra sparing seed implant. The purpose of this study is to determine the appropriate modality for prostate volume measurement and creating an updated nomogram for intra-operative planning specific to our technique for pd-103 brachytherapy for efficient seed ordering. Methods: Prostate volumes based on pre-implant CT (Pre-CT), intra-operative ultrasound (TRUS), and post-implant CT (post-CT) studies as well as the total airkerma strength (AKS) of the implants were analyzed for 135 seed implant cases (69 monotherapy, 66 boost). Regression analysis was performed to derive the relationship between the total AKS and pre-CT and TRUS volumes. The correlation between TRUS and pre-CT volumes and TRUS and post-CT volumes were also studied. Results: Ultrasound based prostate volume exhibited a stronger correlation with total AKS than the pre-implant CT volume (R{sup 2} = 0.97 vs 0.88 for monotherapy and 0.96 vs 0.89 for boost). In general the pre-CT overestimated the prostate volume leading to ordering of a larger number of seeds and thus leading to higher number of unused/wasted seeds. Newly derived TRUS based nomogram was better suited for our technique than the published data. The post-implant CT volume closely followed the ultrasound volume (R{sup 2} = 0.88) as compared to pre-implant CT volumes (R{sup 2} = 0.57). Conclusion: In an era of costconscious health care where waste reduction is of utmost importance, an updated technique-specific nomogram is useful for ordering optimal number of seeds resulting in significant cost savings. In addition, our study shows that ultrasound based prostate volume is a better predictor for seed ordering for intra-operative planning than pre-implant CT.
A single-scan radiography system has been interfaced to a minicomputer, and the combined system has been used with a variety of fluoroscopic systems and image intensifiers available in clinical facilities. The system's response range is analyzed, and several applications are described. These include determination of the gray scale for typical X-ray-fluoroscopic-television chains, measurement of gallstone volume in patients, localization of markers or other small anatomical features, determinations of organ areas and volumes, computer reconstruction of tomographic sections of organs in motion, and computer reconstruction of transverse axial body sections from fluoroscopic images. It is concluded that this type of system combined with a minimum of statistical processing shows excellent capabilities for delineating small changes in differential X-ray attenuation.
In the present study, the multiphase volume distribution problem, where there can be an arbitrary number of phases, is addressed using a consistent and conservative volume distribution algorithm. The proposed algorithm satisfies the summation constraint, the conservation constraint, and the consistency of reduction. The first application of the volume distribution algorithm is to determine the Lagrange multipliers in multiphase Phase-Field models that enforce the mass conservation, and a multiphase conservative Allen-Cahn model that satisfies the consistency of reduction is developed. A corresponding consistent and conservative numerical scheme is developed for the model. The multiphase conservative Allen-Cahn model has a better ability than the multiphase Cahn-Hilliard model to preserve under-resolved structures. The second application is to develop a numerical procedure, called the boundedness mapping, to map the order parameters, obtained numerically from a multiphase model, into their physical interval, and at the same time to preserve the physical properties of the order parameters. Along with the consistent and conservative schemes for the multiphase Phase-Field models, the numerical solutions of the order parameters are reduction consistent, conservative, and bounded, which are theoretically analyzed and numerically validated. Then, the multiphase Phase-Field models are coupled with the momentum equation by satisfying the consistency of mass conservation and the consistency of mass and momentum transport, thanks to the consistent formulation. Finally, it is demonstrated that the proposed model and scheme converge to the sharp-interface solution and are capable of capturing the complicated multiphase dynamics even when there is a large density and/or viscosity ratio.
Purpose: To evaluate the effect of trimodal image fusion using computed tomography (CT), magnetic resonance imaging (MRI) and {sup 11}C-methionine positron emission tomography (MET-PET) for gross tumor volume delineation in fractionated stereotactic radiotherapy of skull base meningiomas. Patients and Methods: In 32 patients with skull base meningiomas, the gross tumor volume (GTV) was outlined on CT scans fused to contrast-enhanced MRI (GTV-MRI/CT). A second GTV, encompassing the MET-PET positive region only (GTV-PET), was generated. The additional information obtained by MET-PET concerning the GTV delineation was evaluated using the PET/CT/MRI co-registered images. The sizes of the overlapping regions of GTV-MRI/CT and GTV-PET were calculated and the amounts of additional volumes added by the complementing modality determined. Results: The addition of MET-PET was beneficial for GTV delineation in all but 3 patients. MET-PET detected small tumor portions with a mean volume of 1.6 {+-} 1.7 cm{sup 3} that were not identified by CT or MRI. The mean percentage of enlargement of the GTV using MET-PET as an additional imaging method was 9.4% {+-} 10.7%. Conclusions: Our data have demonstrated that integration of MET-PET in radiotherapy planning of skull base meningiomas can influence the GTV, possibly resulting in an increase, as well as in a decrease.
An idealized diffusion–evaporation model of time-dependent mixing between a cloud volume and a droplet-free volume is analyzed. The initial droplet size distribution (DSD) in the cloud volume is assumed to be monodisperse. It is shown that evolution of the microphysical variables and the final equilibrium state are unambiguously determined by two non-dimensional parameters. The first one is the potential evaporation parameter R, proportional to the ratio of the saturation deficit to the liquid water content in the cloud volume, that determines whether the equilibrium state is reached at 100 % relative humidity, or is characterized by a complete evaporation of cloud droplets. The second parameter Da is the Damkölher number equal to the ratio of the characteristic mixing time to the phase relaxation time. Parameters R and Da determine the type of mixing. The results are analyzed within a wide range of values of R and Da. It is shown that there is no pure homogeneous mixing, since the first mixing stage is always inhomogeneous. The mixing type can change during the mixing process. Any mixing type leads to formation of a tail of small droplets in DSD and, therefore, to DSD broadening that depends on Da. At large Da, the final DSD dispersion can be as large as 0.2. The total duration of mixing varies from several to 100 phase relaxation time periods, depending on R and Da. The definitions of homogeneous and inhomogeneous types of mixing are reconsidered and clarified, enabling a more precise delimitation between them. The paper also compares the results obtained with those based on the classic mixing concepts.
Purpose: To evaluate the margins currently used to generate the planning target volume for lung tumors and to determine whether image-guided patient setup or respiratory gating is more effective in reducing uncertainties in tumor position. Methods and Materials: Lung tumors in 7 patients were contoured on serial four-dimensional computed tomography (4DCT) data sets (4-8 4DCTs/patient; 50 total) obtained throughout the course of treatment. Simulations were performed to determine the tumor position when the patient was aligned using skin marks, image-guided setup based on vertebral bodies, fiducials implanted near the tumor, and the actual tumor volume under various scenarios of respiratory gating. Results: Because of the presence of setup uncertainties, the reduction in overall margin needed to completely encompass the tumor was observed to be larger for imaged-guided patient setup than for a simple respiratory-gated treatment. Without respiratory gating and image-guided patient setup, margins ranged from 0.9 cm to 3.1 cm to completely encompass the tumor. These were reduced to 0.7-1.7 cm when image-guided patient setup was simulated and further reduced with respiratory gating. Conclusions: Our results indicate that if respiratory motion management is used, it should be used in conjunction with image-guided patient setup in order to reduce the overall treatment margin effectively.
A 1:300 scale wind-tunnel model of a conceptual High-Speed Civil Transport (HSCT) designed to generate a shaped, low-boom pressure signature on the ground was tested to obtain sonic-boom pressure signatures in the Langley Research Center Unitary Plan Wind Tunnel at a Mach number of 1.8 and a separation distance of about two body lengths or four wing-spans from the model. Two sets of engine nacelles representing two levels of engine technology were used on the model to determine the effects of increased nacelle volume. Pressure signatures were measured for (model lift)/(design lift) ratios of 0.5, 0.63, 0.75, and 1.0 so that the effect of lift on the pressure signature could be determined. The results of these tests were analyzed and used to discuss the agreement between experimental data and design expectations.
Determination that equipment can operate in and survive exposure to the humidity environments unique to human rated spacecraft presents widely varying challenges. Equipment may need to operate in habitable volumes where the atmosphere contains perspiration, exhalation, and residual moisture. Equipment located outside the pressurized volumes may be exposed to repetitive diurnal cycles that may result in moisture absorption and/or condensation. Equipment may be thermally affected by conduction to coldplate or structure, by forced or ambient air convection (hot/cold or wet/dry), or by radiation to space through windows or hatches. The equipment s on/off state also contributes to the equipment s susceptibility to humidity. Like-equipment is sometimes used in more than one location and under varying operational modes. Due to these challenges, developing a test scenario that bounds all physical, environmental and operational modes for both pressurized and unpressurized volumes requires an integrated assessment to determine the "worst-case combined conditions." Such an assessment was performed for the Constellation program, considering all of the aforementioned variables; and a test profile was developed based on approximately 300 variable combinations. The test profile has been vetted by several subject matter experts and partially validated by testing. Final testing to determine the efficacy of the test profile on actual space hardware is in the planning stages. When validation is completed, the test profile will be formally incorporated into NASA document CxP 30036, "Constellation Environmental Qualification and Acceptance Testing Requirements (CEQATR)."
The NASA Langley Research Center's Aircraft Vortex Spacing System (AVOSS) requires accurate winds and turbulence to determine aircraft wake vortex behavior near the ground. Volume 1 described the wind input and quality analysis process. This volume documents the data available during the period January 1998 through January 1999 and the partitioning and concatenation of files for time of day, turbulence, non duplication, cross wind profile quality and ceiling and visibility. It provides the resultant filtered files for the first three partitions as well as identification of ceiling/visibility conditions when they were below 5000 feet and 5 miles respectively. It also includes the wind profile quality flags to permit automatic selection of files for AVOSS application using selected ceiling/visibility and wind profile quality values and flags (or no flags).