Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Generalizable, tunable control of divalent cation solvation structure via mixed anion contact ion pair formation

Multivalent batteries are a promising new technology for energy storage, but they face challenges to developing suitable electrolytes that can support reversible deposition/dissolution at the metal anode and enable compatibility with high voltage oxide cathode materials. Here, in this work, we investigate the solvation behavior of Zn 2+ , Mg 2+ , Ca 2+ and Cu 2+ in mixed anion electrolytes containing TFSI - and Cl - . Raman and nuclear magnetic resonance spectroscopies are utilized to probe the bulk solvation structure of these electrolytes and demonstrate that mixed anion contact ion pairs (CIPs) are formed in all four systems, indicating this behavior is likely general to divalent cations. Furthermore, the relative population of mixed anion CIPs can be tuned by controlling the relative ratio of TFSI : Cl, with significant CIP populations observed even at low relative fractions of Cl - . These findings imply that modifying the anion chemistry can easily adjust the solvation structure of bulk cations, which has important implications for the development of next-generation electrolytes. By understanding the factors that influence the formation of mixed anion CIPs, we can design systems that promote the formation of electrochemically-active solvation structures that can enable multivalent batteries with improved performance and lifetimes.

25 ENERGY STORAGE↗

High Energy Density and Stable Three-Dimensionally Structured Se-Loaded Bicontinuous Porous Carbon Battery Electrodes

Here, 3D structured Se-loaded bicontinuous porous carbon (BPC) electrodes were fabricated through colloidal templating of BPC followed by pulsed-voltage Se electrodeposition. The resultant electrodes were found to deliver a specific capacity of 665 mA h g -1 at a rate of 0.1 C, near the theoretical value for Se. When a vinylene carbonate containing electrolyte was utilized, the capacity fade over 500 cycles at 1 C rate was as small as a few percent. Impedance measurements and physical characterization of cycled electrodes indicated the exceptionally stable cycling performance was possibly due to vinylene carbonate resulting in formation of a stable SEI during cycling. Along with cycling stability, the rate performance of the 3D Se/BPC electrodes was also good. Due to the bicontinuous structure of carbonaceous current collector at rates as high as 5 C, the deliverable capacity was about 300 mA h g -1 .

25 ENERGY STORAGE↗

Tradeoffs in single stage drift step recovery diode generator design

A high-voltage generator of nanosecond pulses utilizing a drift step recovery diode (DSRD) as an opening switch in the compression section is designed to operate at peak voltages of 4 kV and repetition rates of 2 MHz in burst mode at reduced voltages. The generator is used to perform empirical studies on the output metrics of a DSRD generator with a focus on matching the circuit of the reverse current loop parameters and DSRD to the load. The dynamic impedance introduced by nonlinear elements in the DSRD was investigated with respect to the driving circuit by varying the number of DSRDs connected in series. Experimental results indicate that optimization of the driving circuit for the DSRD is key to minimizing losses and achieving optimal pulse compression. Furthermore, the results also indicate trends in DSRD performance as larger storage inductances and longer pumping times are used, limiting the pulse compression capabilities of a single stage DSRD generator.

Electrical properties and parameters↗

Exploring the Frontiers of Energy Efficiency using Power Management at System Scale

In the face of surging power demands for exascale HPC systems, this work tackles the critical challenge of understanding the impact of software-driven power management techniques like Dynamic Voltage and Frequency Scaling (DVFS) and Power Capping. These techniques have been actively developed over the past few decades. By combining insights from GPU benchmarking to understand application power profiles, we present a telemetry data-driven approach for deriving energy savings projections. This approach has been demonstrably applied to the Frontier supercomputer at scale. Our findings based on three months of telemetry data indicate that, for certain resource-constrained jobs, significant energy savings (up to 8.5%) can be achieved without compromising performance. This translates to a substantial cost reduction, equivalent to 1438 MWh of energy saved. The key contribution of this work lies in the methodology for establishing an upper limit for these best-case scenarios and its successful application. This work enables HPC professionals to optimize the power-performance trade-off within constrained power budgets, not only for the exascale era but also beyond.

Karimi, Ahmad Maroof↗

The current-voltage relationship in auroral current sheets

The current-voltage relation within narrow auroral current sheets is examined through the use of high-resolution data from the high altitude Dynamics Explorer 1 satellite. The north-south perpendicular electric field and the east-west magnetic field are shown for three cases in which there are large amplitude, oppositely directed paired electric fields and narrow current sheets. These data are shown to indicate that there is a linear Ohm's law relationship between the current density and the parallel potential drop within the narrow current sheets. This linear relationship had previously been verified for large-scale auroral formations greater than 20 km wide at the ionosphere. The evidence shown here extends our knowledge down to the scale size of discrete auroral arcs.

Weimer, D. R.↗

Correlating Electronic Structure and Device Physics with Mixing Region Morphology in High-Efficiency Organic Solar Cells

The donor/acceptor interaction in non-fullerene organic photovoltaics leads to the mixing domain that dictates the morphology and electronic structure of the blended thin film. Initiative effort is paid to understand how these domain properties affect the device performances on high-efficiency PM6:Y6 blends. Different fullerenes acceptors are used to manipulate the feature of mixing domain. It is seen that a tight packing in the mixing region is critical, which could effectively enhance the hole transfer and lead to the enlarged and narrow electron density of state (DOS). As a result, short-circuit current (J SC ) and fill factor (FF) are improved. The distribution of DOS and energy levels strongly influences open-circuit voltage (V OC ). The raised filling state of electron Fermi level is seen to be key in determining device V OC . Energy disorder is found to be a key factor to energy loss, which is highly correlated with the intermolecular distance in the mixing region. A 17.53% efficiency is obtained for optimized ternary devices, which is the highest value for similar systems. The current results indicate that a delicate optimization of the mixing domain property is an effective route to improve the V OC , J SC , and FF simultaneously, which provides new guidelines for morphology control toward high-performance organic solar cells.

36 MATERIALS SCIENCE↗

F-5F Shark Nose radome lightning test

A unique F-5F radome wtih a geometry similar to a Shark Nose profile was tested with a high voltage Marx generator, 1,200,000 volts in order to demonstrate the effectiveness of the lightning protection system with currents from 5,000 amperes or greater. An edge discontinuity configuration is a characteristic feature in the forward region of the radome and occasionally serves as an attachment point. The results of nineteen attachment tests at various aspect angles with an air gap of one meter indicated that no damage occurred to the dielectric material of the radom. The test proved the effectiveness of the lightning protection system.

Scott, G. W.↗

Battery Fault Detection with Saturating Transformers

A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.

Davies, Francis J.↗

Hybrid-PIC Modeling of the Transport of Atomic Boron in a Hall Thruster

Computational analysis of the transport of boron eroded from the walls of a Hall thruster is performed by implementing sputter yields of hexagonal boron nitride and velocity distribution functions of boron within the hybrid-PIC model HPHall. The model is applied to simulate NASA's HiVHAc Hall thruster at a discharge voltage of 500V and discharge powers of 1-3 kW. The number densities of ground- and 4P-state boron are computed. The density of ground-state boron is shown to be a factor of about 30 less than the plasma density. The density of the excited state is shown to be about three orders of magnitude less than that of the ground state, indicating that electron impact excitation does not significantly affect the density of ground-state boron in the discharge channel or near-field plume of a Hall thruster. Comparing the rates of excitation and ionization suggests that ionization has a greater influence on the density of ground-state boron, but is still negligible. The ground-state boron density is then integrated and compared to cavity ring-down spectroscopy (CRDS) measurements for each operating point. The simulation results show good agreement with the measurements for all operating points and provide evidence in support of CRDS as a tool for measuring Hall thruster erosion in situ.

Materials Engineering↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultraviolet irradiation at elevated temperatures and thermal cycling in vacuum of FEP-A covered silicon solar cells

Silicon solar cells covered with FEP-A were irradiated in vacuum with ultraviolet light and then subjected to thermal cycling. These accelerated laboratory conditions are believed to be equivalent to those experienced by FEP-A covered cells on the ATS-6 spacecraft and the results indicate a probable mechanism for the faster degradation of the FEP-A covered cells. Heat-bonded FEP-A covers apparently embrittle when exposed to four months of space UV radiation at elevated temperatures, and crack when subjected to thermal cycling during the eclipse period. Low energy proton radiation can then penetrate to the junction of the cell causing degradation of the open circuit voltage and maximum power to occur. An alternate method of application of FEP-A, such as with adhesives, may prevent such cracking.

Broder, J. D.↗

Magnetic emissions testing of the space station engineering model resistojet

The engineering model resistojet intended for altitude maintenance onboard the space station was tested for magnetic radiation emissions in the Radio Frequency Interference (RFI) facility at the Goddard Space Flight Center. The resistojet heater was supplied with power at 20 kHz and low voltage through a power controller. The resistojet was isolated from its power supply in the RFI enclosure, and the magnetic emission measured at three locations around the resistojet at various heater currents. At a heater current of 18.5 A the maximum magnetic emission was 61 dBpt at a distance of 1 m from the resistojet and at a location at the rear of the thruster. Calculations indicate that the case and heat shields provided a minimum of 4 dB of attenuation at a current of 18.5 A. Maximum radiation was measured at the rear of the resistojet along its major axis and was thought to be due to the magnetic radiation from the power leads. At a distance of 37 cm from the resistojet the maximum magnetic radiation measured was 73 dBpt at a current of 11.2 A. The power input leads were also a source of magnetic radiation. The engineering model rssistojet requires about 20 dB of additional shielding.

Briehl, Daniel↗

Evaluation of high temperature capacitor dielectrics

Experiments were carried out to evaluate four candidate materials for high temperature capacitor dielectric applications. The materials investigated were polybenzimidazole polymer and three aramid papers: Voltex 450, Nomex 410, and Nomex M 418, an aramid paper containing 50 percent mica. The samples were heat treated for six hours at 60 C and the direct current and 60 Hz alternating current breakdown voltages of both dry and impregnated samples were obtained in a temperature range of 20 to 250 C. The samples were also characterized in terms of their dielectric constant, dielectric loss, and conductivity over this temperature range with an electrical stress of 60 Hz, 50 V/mil present. Additional measurements are underway to determine the volume resistivity, thermal shrinkage, and weight loss of the materials. Preliminary data indicate that the heat treatment of the films slightly improves the dielectric properties with no influence on their breakdown behavior. Impregnation of the samples leads to significant increases in both alternating and direct current breakdown strength. The results are discussed and conclusions made concerning their suitability as high temperature capacitor dielectrics.

Hammoud, Ahmad N.↗

Maximized Hole Trapping in a Polystyrene Transistor Dielectric from a Highly Branched Iminobis(aminoarene) Side Chain

We synthesized highly branched and electron donating side chain subunits and attached them to polystyrene (PS) used as a dielectric layer in a pentacene field effect transistor. The influence of these groups on dielectric function, charge retention and threshold voltage shifts (ΔV th ) depending on their positions in dielectric multilayers was determined. We compared the observations made on an N-perphenylated iminobisaniline side chain with those from the same side chains modified with ZnO nanoparticles and with an adduct formed from tetracyanoethylene (TCNE). We also synthesized an analogue in which six methoxy groups are present instead of two amine nitrogens. At 6 mol % side chain, hopping transport was sufficient to cause shorting of the gate, while at 2 mol %, charge trapping was observable as transistor threshold voltage shifts (ΔV th ). Here, we created three types of devices: with the substituted PS layer as single layer dielectric, on top of a crosslinked PS layer but in contact with the pentacene (bilayers), and sandwiched between two PS layers in trilayers. Particularly large bias stress effects and ΔV th , larger than the hexamethoxy and previously studied dimethoxy analogs, were observed in the second case and the effects increased with the increasing electron donating properties of the modified side chains. The highest ΔV th was consistent with a majority of the side chains stabilizing trapped charge. Trilayer devices showed decreased charge storage capability compared to previous work in which we used less donating side chains but in higher concentrations. The ZnO and TCNE modifications resulted in slightly more and less negative ΔV th , respectively, when the side chain polystyrene was not in contact with the pentacene and isolated from the gate electrode. The results indicate a likely maximum combination of molecular charge stabilizing activity and side chain concentration that still allows gate dielectric function.

36 MATERIALS SCIENCE↗

Lithium plating induced degradation during fast charging of batteries subjected to compressive loading

Here we report the lithium plating associated capacity loss during fast charging of compressively loaded lithium-ion batteries (LIBs). The charging and discharging of LIB under compressive loading during service may affect the cell performance or initiate localized defects in the electrodes. Pouch cells of capacity 20 mAh were compressively loaded to nominal pressures of 0–440 kPa and subjected to 10 cycles of fast charging at 1 C and 4 C. Experimental results show that cells charged at 4 C-rate experienced significant capacity fade, and applying compressive loads exacerbated the capacity loss. The coulombic efficiency study shows that active lithium loss was higher for the initial cycles before gradually reducing to a minimal capacity loss for the tenth charging cycle. The cell voltage relaxation immediately after charging was monitored to identify the stripping of plated lithium after fast charging cycles and showed that the duration of lithium stripping was higher for cells under mechanical compressive loading. Scanning electron microscopy (SEM) and electron paramagnetic resonance spectroscopy (EPR) characterization of the anode showed significantly higher lithium deposits on the anodes charged at a 4 C rate under compressive loads. These results indicate that applied mechanical compression causes increased lithium plating during fast charging of batteries.

25 ENERGY STORAGE↗

A technoeconomic analysis of poly- and single-crystalline NMCxyz from material synthesis to battery pack design

A process model was developed for estimating the cost of manufacturing lithium nickel manganese cobalt oxide (LiNi x Mn y Co z O 2 , NMCxyz), the main cathode active material in lithium-ion batteries used for electric vehicles in the United States. The model was used to estimate the prices of NMC622, NMC811, and NMC955 with poly- and single-crystalline morphologies. The Battery Performance and Cost Model (BatPaC) was used to translate the NMC prices into battery pack prices. A decrease in cobalt content from NMC622 (20% Co) to NMC955 (5% Ni) decreases the material price by $\$$0.85/kg (−3%) due to a decrease in the cost of battery materials, which account for >60% of the total price. NMC622 only produce cheaper packs if the nickel sulfate cost is > 4 × its baseline, indicating higher nickel materials will lower pack cost under normal market conditions. Single-crystalline materials are $\$$2/kg (+8%) more expensive than their polycrystalline counterparts due to higher manufacturing costs from longer, hotter calcinations in less densely packed saggars. This increases the pack price by ∼$\$$3/kWh, assuming identical electrochemical properties. In conclusion, the single-crystalline materials could yield cheaper packs if cycled to higher upper cutoff voltages (i.e., 4.35 to 4.43 V for the single-crystalline material vs. 4.25 V for their polycrystalline counterparts).

Cost modeling↗

A low-frequency buncher field-variation study on a 750 keV H – beam to increase Drift Tube Linac capture

We report low-frequency (such as 16.77 MHz) RF bunchers are widely used in RF accelerator systems for longitudinal compression of pulses into a single RF bucket, which increases instantaneous beam intensity for time-dependent studies. In this study, the dependency of capture into a 201.25 MHz Drift Tube Linac (DTL) was measured as a function of gap voltage for a 16.77 MHz buncher on chopped H - beam (approximately 25 ns at 750 keV, 10 mA peak current). The multiparticle code PARMILA was used to simulate the phase-space distribution of the 10 mA, 750 keV, H - beam at the entrance to DTL with a wide range of the Low-Frequency Buncher (LFB) field (10 kV to 35 kV). The measurement and simulation indicated that the DTL capture could be dilute (reduced) for a non-optimized buncher field to a pre-configured beamline geometry. The data shows that changing the bunch field while keeping the incoming beam current and energy constant does not significantly alter the beam’s emittance. However, downstream beam capture into the DTL is changed for a non-optimized phase-space bunching distance with the buncher field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗