Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Self-broadening and line mixing in HCN Q branches

A tunable difference-frequency laser has been used to record Q-branch spectra of the nu sub 1 + nu sub 2 (4004/cm) and nu sub 2 + nu sub 3 (2806/cm) combination bands, as well as the nu sub 1 - nu sub 2 (2599/cm) difference hot band of HCN, at 1-400 torr pressures. Line mixing is noted in the strongly overlapped, higher-pressure Q-branch profiles from the nonradiative Lorentzian superposition of the component transitions. An effective R to T transition energy-corrected-sudden scaling law is found to give a consistent and satisfactory fit to the Q-branch profiles of all three bands.

Pine, A. S.↗

Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

Quagliaroli, T. M.↗

A comparison of vector magnetograms from the Marshall Space Flight Center and Mees Solar Observatory

The paper compares completely independent vector magnetic field measurements from two very different polarimetric instruments. The Marshall Space Flight Center's (MSFC's) imaging vector magnetograph is based on a birefringent filter, routinely measuring all four Stokes parameters integrated over the filter bandpass (1/8 A) which is tunable across the Fe I 5250 line in 10 mA steps. The Haleakala Stokes Polarimeter of the Mees Solar Observatory (MSO) is based on a spectrometer, routinely measuring all four Stokes parameters of the Fe I 6302.5 line simultaneously and then spatially scanning to build up a vector magnetogram. Active region magnetic field data were obtained with both the MSFC and MSO systems on five days during June 1985. After interpolating the MSFC vector fields onto the more coarse spatial grid of MSO, a point-by-point comparison of the two vector fields is made for data obtained on two of these days (June 8 and 9). From this comparison it is concluded that the spatially-averaged line-of-sight components agree quite well, and that although the MSO spatial grid is coarser, the quality of the MSO image is better than that of the MSFC data because of better seeing conditions.

Ronan, R. S.↗

Absorption spectra of HCFC-22 around 829/cm at atmospheric conditions

Spectral absorption coefficients of HCFC-22 have been measured around 829/cm in the laboratory at various temperature-pressure combinations chosen to represent tangent heights (as in solar-occultation experiments) or layers in the atmosphere. The data measured employing the Doppler-limited spectra resolution (about 10 exp -4/cm) of a tunable diode laser spectrometer are free of instrumental distortion and are more practical in this case than the spectral line parameters adapted in conventional line-by-line procedures for analyzing atmospheric spectra. The present data obtained with N2 as the broadening gas are shown to be directly applicable to the real atmosphere.

Varanasi, Prasad↗

Intensity and linewidth measurements in the 13.7-micron fundamental bands of (C-12)2H2 and (C-12)(C-13)H2 at planetary atmospheric temperatures

The absolute intensities and collision-broadened half-widths of several lines in the P-,Q-, and R-branches of the nu5-fundamental band of (C-12)2H2 have been measured at various temperatures between 147 and 295 K employing the Doppler-limited spectral resolution (about 10 exp -4/cm) of a tunable diode laser spectrometer. The absolute intensities of R(5), R(7), R(9), and R(20) in the same fundamental belonging to (C-12)(C-13)H2 have also been measured at 294 K. The temperature dependence of the collision-broadened half-width has been determined for some of the lines broadened by planetary atmospheric gases, namely, He, Ar, H2, and N2. Four self-broadened linewidths of (C-12)2H2, as well as three H2-broadened linewidths and a self-broadened half-width of (C-12)(C-13)H2, have also been retrieved from the measurements.

Varanasi, Prasad↗

Far-infrared self-broadening in methylcyanide - Absorber-perturber resonance

Using tunable far-infrared spectrometers with high-frequency stability and accuracy, the self-pressure broadening and shift of CH3CN are measured. Evidence of absorber-perturber resonance effects on the collisional line shape are obtained. This tests the theoretical model and its possible improvements and also allows predictions of broadening and shift for a large class of molecules. Moreover, the resonance effect produces a theoretical temperature dependence of self-broadening that is different from what is commonly assumed.

Buffa, G.↗

Precise laser frequency scanning using frequency-synthesized optical frequency sidebands - Application to isotope shifts and hyperfine structure of mercury

Based on an efficient broadband electrooptic modulator producing RF optical sidebands locked to a stable cavity, a tunable dye laser can be scanned under computer control with frequency-synthesizer precision. Cavity drift is suppressed in software by using a strong feature in the spectrum for stabilization. Mercury isotope shifts are measured with a reproducibility of about 50 kHz. This accuracy of about 1/300 of the linewidth illustrates the power of the technique. Derived hyperfine-structure constants are compared with previous atomic-beam data.

Rayman, M. D.↗

State-to-state rotational energy-transfer measurements in the nu(2) = 1 state of ammonia by infrared-infrared double resonance

The state-resolved rotational (R-R, R-T) energy transfer in (N-14)H3 (for NH3-NH3 and NH3-Ar collisions) was studied using an IR double-resonance laser spectroscopic technique. Measurements of both the total rate of depopulation by collisions, and the rates of transfer into specific final rovibrational states (v,J,K) were performed using time-resolved tunable diode laser absorption spectroscopy. A kinetic master-equation analysis of time-resolved level populatons was carried out, yielding state-to-state rate constants and propensity rules for NH3-NH3 and NH3-Ar collisions.

Abel, Bernd↗

Generation of sub-100-fs pulses from a CW mode-locked chromium-doped forsterite laser

Generation of femtosecond pulses from a continuous-wave mode-locked chromium-doped forsterite laser is reported. The forsterite laser was actively mode locked by using an acoustooptic modulator operating at 78 MHz with two Brewster high-dispersion glass prisms for intracavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(00) mode with 85 mW of continuous power (with 1 percent output coupler), tunable over 1230-1280 nm. The shortest pulses measured had a 60-fs pulse width.

Seas, A.↗

Numerical study of low-current steady arcs

The development of a high-efficiency CW YLF laser doped with Er,Tm,Ho: and featuring a strongly focusing resonator that collects a high density of pump power on the active crystal is described. The emission is investigated at 2.06 microns and a tuning range both at liquid-nitrogen (77 K) and at dry-ice (210 K) temperature. The noise characteristics and the long-term power stability of the laser is studied with an eye to employing this source for high-resolution spectroscopy in the 2-micron wavelength region. The detection of several absorption lines of NH3 at low pressure is described. The output power of the laser as a function of the power impinging on the crystal for different transmission of the output mirror is illustrated. The best result obtained is 1.46 W output for 3.2 W of argon pump. The minimum threshold achieved is 3.5 mW with a 1-percent transmission mirror. It is concluded that it is possible to develop a highly efficient Ho:YLF laser featuring low noise and sufficient tunability for high-resolution spectroscopy in the 2-micron region.

Kim, S. C.↗

Theoretical and experimental analysis of injection seeding a Q-switched alexandrite laser

Injection seeding is a method for achieving linewidths of less than 500 MHz in the output of broadband, tunable, solid state lasers. Dye lasers, CW and pulsed diode lasers, and other solid state lasers have been used as injection seeders. By optimizing the fundamental laser parameters of pump energy, Q-switched pulse build-up time, injection seed power and mode matching, one can achieve significant improvements in the spectral purity of the Q-switched output. These parameters are incorporated into a simple model for analyzing spectral purity and pulse build-up processes in a Q-switched, injection-seeded laser. Experiments to optimize the relevant parameters of an alexandrite laser show good agreement.

Prasad, C. R.↗

Aerodyne Research mobile infrared methane monitor

An improved real-time methane monitor based on infrared absorption of the 3.39 micron line of a HeNe laser is described. Real time in situ measurement of methane has important applications in stratospheric and tropospheric chemistry, especially when high accuracy measurements can be made rapidly, providing fine spatial-scale information. The methane instrument provides 5 ppb resolution in a 1 sec averaging time. A key feature in this instrument is the use of magnetic (Zeeman) broadening to achieve continuous tunability with constant output power over a range of 0.017/cm. The instruments optical absorption path length is 47 m through sampled air held at 50 torr in a multipass cell of the Herriott (off-axis resonator) type. A microprocessor controls laser frequency and amplitude and collects data with minimal operator attention. The instrument recently has been used to measure methane emissions from a variety of natural and artificial terrestrial sources.

Mcmanus, J. B.↗

Polarization-stabilized 1.15- and 3.39-micron He-Ne lasers

Two methods for polarization stabilization of an internal-mirror 3.39-micron He-Ne laser are reported. The first relies on a concurrently lasing 1.15-micron transition by fixing the relative amplitude of two orthogonally polarized longitudinal modes that are split by a Rochon prism and detected with separate Si photodiodes. In the second method, two spatially separated orthogonally polarized adjacent 3.39-micron modes are optically balanced, differentially chopped, and recombined on a single InSb photodiode for phase-sensitive detection. The dual-wavelength scheme has been tested by beating against a methane-stabilized 3.39-micron He-Ne laser, which yields maximum excursions of less than 0.5 MHz over several hours and comparable reproducibility. The polarization-stabilized He-Ne laser has been used as a reference for a tunable color-center laser molecular-beam optothermal spectrometer and provides a precision of better than 2 MHz.

Junttila, M.-L.↗

Infrared absorption-coefficient data on SF6 applicable to atmospheric remote sensing

Spectral absorption coefficients, k(nu)/cm per atm, of SF6 have been measured in the central Q-branches of the nu(3)-fundamental at 947/cm at various temperature-pressure combinations representing tangent heights in solar-occultation experiments or layers in the atmosphere. The data obtained with the Doppler-limited spectral resolution (about 0.0001/cm) of a tunable-diode laser spectrometer are useful in the atmospheric remote sensing of this trace gas.

Varanasi, P.↗

Absorption coefficients of CFC-11 and CFC-12 needed for atmospheric remote sensing and global warming studies

Spectral absorption coefficients k(v) in the atmospheric window are reported for CFC-11 and CFC-12. Data obtained with a grating spectrometer are compared with NCAR cross sections and measurements of k(v) made with a tunable diode laser spectrometer at various temperature-pressure combinations representing tangent heights or layers in the atmosphere are presented. The results are suitable for atmospheric remote sensing and global warming studies.

Varanasi, Prasad↗

Demonstration AOTF Imaging Spectrometer

Spectral images of high quality obtained. Acousto-optical-tunable-filter (AOTF) imaging spectrometer is optical system in which AOTF serves as spectrally dispersive element causing image on final focal plane to be shifted on plane by distance depending on wavelength of light emanating from scene. Useful in several applications involving identification, via characteristic spectras, of substances in observed scenes: examples include prospecting for minerals and detecting chemical pollutants.

Chao, Tien-Hsin↗

A quasioptical resonant-tunneling-diode oscillator operating above 200 GHz

We have fabricated and characterized a quasioptically stabilized resonant-tunneling-diode (RTD) oscillator having attractive performance characteristics for application as a radiometric local oscillator. The fundamental frequency of the oscillator is tunable from about 200 to 215 GHz, the instantaneous linewidth is between 10 and 20 kHz, and the output power across the tuning band is about 50 micro-W. The narrow linewidth and fine tuning of the frequency are made possible by a scanning semiconfocal open cavity which acts as the high-Q resonator for the oscillator. The cavity is compact, portable, and insensitive to vibration and temperature variation. The total dc power consumption (RTD plus bias supply) is only 10 mW. The present oscillator provides the highest power obtained to date from an RTD above 200 GHz. We attribute this partly to the use of the quasioptical resonator, but primarily to the quality of the RTD. It is fabricated from the In(0.53)Ga(0.47)As/AlAs materials system, which historically has yielded the best overall resonant-tunneling characteristics of any material system. The RTD active area is 4 sq microns, and the room-temperature peak current density and peak-to-valley current ratio are 2.5x10(exp 5) A cm(exp -2) and 9, respectively. The RTD is mounted in a WR-3 standard-height rectangular waveguide and is contacted across the waveguide by a fine wire that protrudes through a via hole in a Si3N4 'honeycomb' overlayer. We estimate that the theoretical maximum frequency of oscillation of this RTD is approximately 1.1 THz, and that scaled-down versions of the same quasioptical oscillator design should operate in a fundamental mode up to frequencies of at least 500 GHz.

Brown, E. R.↗