Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Use of Novel Diglycolamide Extractants in Liquid-liquid Separations of Light Rare Earths

Creation of a novel extractant that can improve rare earth separations both economically and environmentally will be pivotal for industry progression. Diglycolamide (DGA) extractants provide chemistries that support this goal by serving as an extractant with high affinity for lanthanides and improved separation factors for light rare earths as compared to current extractants like PC88A. Initial organic phase loading capacity and phase dispersion tests performed with various modified DGAs generated results that were unfavorable for industrial processing, but further modification of the DGA alkyl chain substituents have resulted in new structures with promising results. Dispersion time measurements taken in small scale batch contacts of the extractant with a simulated leach liquor containing La, Ce, Nd, and Pr support implementation in both mixer-settlers and centrifugal contactors for larger scale separations. Furthermore, this confirmation allowed for preliminary flowsheet design using extraction equilibria at various organic to aqueous flow ratios (O/A) for extraction, scrubbing, and stripping stages. These values along with expected product/effluent compositions for each section aid in the testing for specific distribution ratios and final flowsheet design. Implementation of the DGA extractant into solvent extraction equipment will provide essential information for the next steps of this project and how this extractant may be optimized for future applications.

42 ENGINEERING↗

Control systems and methods to enable autonomous drilling

A system or method for drilling includes autonomously controlling a rotary or percussive drilling process as it transitions through multiple materials with very different dynamics. The method determines a drilling medium based on real-time measurements and comparison to prior drilling data, and identifies the material type, drilling region, and approximately optimal setpoint based on data from at least one operating condition. The controller uses these setpoints initially to execute an optimal search to maximize performance by minimizing mechanical specific energy. Near-bit depth-of-cut estimations are performed using a machine learning prediction deployed in an embedded processor to provide high-speed ROP estimates. The sensing capability is coupled with a near-bit clutching mechanism to support drilling dysfunction mitigation.

Buerger, Stephen↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrochemical Characterization of Molten Salt Chemistry During Atmospheric Ingressions

This report describes the salt chemistry and sedimentation studies that were completed in FY23 as part of the Pyrochemical Fuel Cycles – ANL project. The primary objective of these activities was to employ electrochemical methods in order to quantify and gain insights into the reaction mechanisms associated with the interaction of O2 and moisture impurities with the molten chloride salts used for the pyrochemical processing of nuclear materials. If not monitored and controlled, the ingression of these atmospheric impurities can lead to changes in the salt redox conditions and initiate the formation of oxide particles, potentially resulting in operational and safeguards challenges. By elucidating the mechanisms underlying the formation of oxide particles, we can effectively monitor the conditions of the salt and design systems to mitigate the influence of atmospheric O2 and H2O. To achieve these goals, we designed a test system that allowed for precisely controlled gas ingressions into the molten salt vessel. This system included on-line monitoring provided by electrochemical probes that enable near real-time measurements of the salt conditions throughout the course of the experiment. Using this system, we systematically varied experimental conditions, including O2/Ar flow rates and O2 concentrations, to comprehensively understand their impact on solid particle formation. We also used a particle size and shape analyzer to characterize the particles that were generated. Tests in FY23 concentrated on the formation of CeO2 particles, but we also prepared a separate apparatus targeting UO2 particles for use in FY24. We additionally conducted extensive modeling activities in support of this work. This included multiphysics simulations of the gas ingressions along with the development of a machine learning workflow to enable accelerated molecular dynamics modeling of the molten salt chemistry of LiCl-KCl-UCl3. The combination of experimental and modeling tools has allowed us to begin to get a more complete understanding of the reactions that occur when atmospheric ingressions occur in pyroprocessing systems.

Guo, Jicheng↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

Separation of Main and Tail Rotor Noise Sources from Ground-Based Acoustic Measurements Using Time-Domain De-Dopplerization

A new method of separating the contributions of helicopter main and tail rotor noise sources is presented, making use of ground-based acoustic measurements. The method employs time-domain de-Dopplerization to transform the acoustic pressure time-history data collected from an array of ground-based microphones to the equivalent time-history signals observed by an array of virtual inflight microphones traveling with the helicopter. The now-stationary signals observed by the virtual microphones are then periodically averaged with the main and tail rotor once per revolution triggers. The averaging process suppresses noise which is not periodic with the respective rotor, allowing for the separation of main and tail rotor pressure time-histories. The averaged measurements are then interpolated across the range of directivity angles captured by the microphone array in order to generate separate acoustic hemispheres for the main and tail rotor noise sources. The new method is successfully applied to ground-based microphone measurements of a Bell 206B3 helicopter and demonstrates the strong directivity characteristics of harmonic noise radiation from both the main and tail rotors of that helicopter.

Greenwood, Eric II↗

The auroral ionosphere - Comparison of a time-dependent model with composition measurements

A time-dependent model of the auroral ionosphere including the odd nitrogen species, NO, N(D-2), and N(S-4), is used for comparison with data from a coordinated rocket-satellite measurement of an auroral event. The chemical scheme and the adopted rate coefficients have been shown to be compatible with daytime mid-latitude ionospheric chemistry. The electron flux and neutral atmospheric parameters measured on the satellite are used to compute the appropriate ionization and dissociation rates. The calculated NO(plus), O2(plus), O(plus), Ne, and NO densities agree well with the rocket measurements. The calculated N2(plus) densities are larger than the measured densities by a factor of 3 at most altitudes. The calculations show that the nitric oxide content of the aurora (about 1.2 times 10 to the 9th NO molecules/cu cm at 105 km) is below the saturation value.

Gerard, J.-C.↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Survey of Time Shift Detection Algorithms for Measured PV Data

In this research, three variations of time shift detection algorithms were tested for their ability to detect time shift issues (including daylight savings time and random time shifts) in measured PV data sets. Two algorithms from the Python PVAnalytics package were assessed, and one algorithm from the Solar-Data-Tools package was assessed. Each algorithm's ability to accurately detect and measure time shifts was assessed.

automated preprocessing↗

A modular multiple use system for precise time and frequency measurement and distribution

A modular CAMAC based system is described which was developed to meet a variety of precise time and frequency measurement and distribution needs. The system was based on a generalization of the dual mixer concept. By using a 16 channel 100 ns event clock, the system can intercompare the phase of 16 frequency standards with subpicosecond resolution. The system has a noise floor of 26 fs and a long term stability on the order of 1 ps or better. The system also used a digitally controlled crystal oscillator in a control loop to provide an offsettable 5 MHz output with subpicosecond phase tracking capability. A detailed description of the system is given including theory of operation and performance. A method to improve the performance of the dual mixer technique is discussed when phase balancing of the two input ports cannot be accomplished.

Reinhardt, V. S.↗

Apparatus for real-time size-distributed measurement of aerosol mass concentration

An impactor, system and method for performing real-time measurements of particles in aerosol gases. The impactor comprises a plurality of cascading stages having impaction plates, mass-measurement mechanisms retained on the impaction plates, and a nozzle plate. A signal line associated with each of the plurality of cascading stages is configured to relay signals from the mass-measurement mechanism of the associated stage to a computer-based system configured to receive the transmitted signals from the signal lines, and to correlate changes in the resonant frequencies to particle concentrations in real time.

Chen, Modi↗

Validation and Uncertainty Analysis of Stereo Time-Resolved PIV Measurements for Boundary-Layer Transition Research

An uncertainty analysis was performed on the stereo time-resolved particle image velocimetry measurements that were obtained in the boundary-layer of a swept wing model. Several different approaches were undertaken to estimate the uncertainty of the PIV measurements and to understand how that uncertainty propagates through to the results of interest. It was found that the stereo registration error, which is often neglected in stereo- PIV uncertainty analysis, can cause significant errors in the measured amplitude of the stationary cross ow instability due to the large spanwise velocity gradients that occur in the ow. The self-calibrations do not always adequately correct for the stereo-registration error. A simple approach is demonstrated for estimating the error due to a misalignment of the calibration target and laser plane. This approach was found to be very successful at predicting the error in stationary cross ow amplitude caused by the misalignment. The time-resolved PIV results are also compared to previously-acquired hotwire data. The TRPIV technique is successful at measuring the same types of unsteady instabilities as the hotwire, and thus does not appear to have any adverse e ect on the transition process due to the introduction of particles into the ow. It was also found that a larger interrogation window size is beneficial for reducing the noise of the TRPIV results.

Eppink, Jenna L.↗

Systematic Center-To-Limb Variation in Measured Helioseismic Travel Times and Its Effect on Inferences of Solar Interior Meridional Flows

We report on a systematic center-to-limb variation in measured helioseismic travel times, which must be taken into account for an accurate determination of solar interior meridional flows. The systematic variation, found in time-distance helioseismology analysis using SDO/HMI and SDO/AIA observations, is different in both travel-time magnitude and variation trend for different observables. It is not clear what causes this systematic effect. Subtracting the longitude-dependent east-west travel times, obtained along the equatorial area, from the latitude-dependent north-south travel times, obtained along the central meridian area, gives remarkably similar results for different observables. We suggest this as an effective procedure for removing the systematic center-to-limb variation. The subsurface meridional flows obtained from inversion of the corrected travel times are approximately 10 m s−1 slower than those obtained without removing the systematic effect. The detected center-to-limb variation may have important implications in the derivation of meridional flows in the deep interior and needs to be better understood.

Sun: oscillations↗

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Global and regional N2O measurements

Real-time N2O measurements have been made in situ at the South Pole, Antarctica, north and south of the equator from on board the Alpha Helix and over the Pacific Ocean on several aircraft flights from the U.S. to New Zealand, Australia and 90 deg S. In addition, an automated EC-GC has been operated for the past year intermittently monitoring N2O in surface air at a rural site in the wheatlands of eastern Washington state. The data obtained are consistent and in agreement with the data obtained from the analyses of a large number of samples collected both from ground stations and a variety of aircraft flights made in the southern and northern hemisphere. The observed global data show no interhemispheric differences. The present concentration of N2O in the troposphere is measured to be 330 + or - 3 ppbv. Its vertical distribution in the troposphere is very uniform. A small decrease (2-3 percent) across the tropopause is characteristically observed in the high-altitude flights.

Rasmussen, R. A.↗