Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Hot-blade stripper for polyester insulation on FCC

Stripper incorporates a blade which is electrically heated to a controlled temperature. Heated blade softens and strips insulation from cable while paper ribbon removes insulation material and keeps blade clean for next operation.

Angele, W.↗

Breathing-metabolic simulator

Breathing-metabolic simulator was developed to be used for evaluation of life support equipment. Apparatus simulates human breathing rate and controls temperature and humidity of exhaled air as well as its chemical composition. All functions are designed to correspond to various degrees of human response.

Bartlett, R. G.↗

A method of treating the non-grey error in total emittance measurements

In techniques for the rapid determination of total emittance, the sample is generally exposed to surroundings that are at a different temperature than the sample's surface. When the infrared spectral reflectance of the surface is spectrally selective, these techniques introduce an error into the total emittance values. Surfaces of aluminum overcoated with oxides of various thicknesses fall into this class. Because they are often used as temperature control coatings on satellites, their emittances must be accurately known. The magnitude of the error was calculated for Alzak and silicon oxide-coated aluminum and was shown to be dependent on the thickness of the oxide coating. The results demonstrate that, because the magnitude of the error is thickness-dependent, it is generally impossible or impractical to eliminate it by calibrating the measuring device.

Heaney, J. B.↗

Standard reference materials: Thermal conductivity of electrolytic iron, SRM 734, from 4 to 300 K

Thermal conductivity data were obtained by the axial one-dimensional heat flow method for a cylindrical rod 3.6 mm in diameter and 23 cm long with an electric heater at one end and a temperature controlled sink at the other. Variability of this iron was studied by means of electrical residual resistivity ratio measurements on 63 specimens. This study showed that with a two-hour anneal at 1000 C one can obtain a thermal conductivity Standard Reference Material that has variability of less than 1% in thermal conductivity.

Hust, J. G.↗

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Thermal test plan for large variable conductance heat pipe

The procedure to be followed in determining the thermal performance of a variable conductance heat pipe is documented. The nominal one-inch-diameter aluminum pipe is of a cold reservoir type whose overall length is nine feet. It has a capacity of 2 to 4 kW's equivalent to 8 to 16 kW-ft and an overall temperature control range of 50 to 95 F. Initial tests will be conducted with the pipe charged with ammonia to determine its capacity limits. Following introduction of the noncondensible gas (nitrogen), the variable conductance features of the pipe will be used.

Edelstein, F.↗

Space shuttle orbiter heat pipe applications. Volume 1: Synopsis

An investigation was made to formulate and evaluate heat pipe applications for the space shuttle orbiter. Of the twenty-seven specific applications which were identified, a joint evaluation resulted in the selection of five of the most promising ones for prototype development. The formulation process is described, along with the applications which evolved. The bulk of the discussion deals with the top five applications: (1) heat pipe augmented cold rail; (2) avionics heat pipe circuit; (3) heat pipe/phase change material modular sink; (4) air-to-heat-pipe heat exchanger; and (5) heat pipe radiator for compartment temperature control. The philosophy, physical design details, and performance data are presented for each concept along with a comparison to the baseline design where applicable. A sixth application, heat pipe space radiator for waste heat rejection, was also recommended for prototype development.

Alario, J. P.↗

Splanchnic vasoconstriction in hyperthermic man - Role of falling blood pressure.

Results of a study in which six supine resting subjects, wearing water-perfused suits, had body skin temperature controlled at 35 C for 30 min (control period), then rapidly increased to 40.5 C for 43 to 50 min (heating period) in a two-part experiment. In the first part of the experiment arterial mean pressure (MP) in three men was increased back to, or above control levels at the 30 to 35th min of heating by total occlusion of both legs for 8 to 10 min. Splanchnic blood flow (SBF), which had fallen from 1.4 to 0.9 L/min at occlusion, rose only 0.05 L/min during occlusion. Splanchnic vascular resistance (SVR) rose throughout heating and occlusion. In the second part of the experiment (three men) SBF fell despite a spontaneous rise in MP and aortic pulse pressure prior to leg occlusion. Cardiac output (CO) was measured just before, during and after occlusion. Occlusion raised MP 10 to 15 mm Hg and reduced CO only slightly. It is concluded that falling MP or aortic pulse pressure are not major causes of the splanchnic vasoconstriction in response to heating man.

Rowell, L. B.↗

Solar radiation calibration facility.

A recently completed calibration facility for the NASA Mississippi Test Site is described. It combines the spectrum of water cooled long arc xenon radiation sources with the integration sphere concept covered by a special barium sulfate diffusely reflecting paint. The sphere is six feet in diameter and completely encompasses the four xenon sources (2.5 kW each) and the five pyranometers under calibration. The sources are contained within the base of the central pedestal and allow the radiation to be emitted into the lower hemisphere. Only through diffuse reflection and multiple scattering is the radiation finally incident upon the test zone, which is in the equatorial plane of the sphere on the top of the pedestal. The sphere is temperature controlled.

Hershey, T. L.↗

Long-term material compatibility testing system

System includes procedure for hermetically sealing solid materials and fluids in glass ampoule and use of temperature-controlled facility containing sample holder, which permits sample containers to be retrieved safely and conveniently. Solid material and fluid are sealed within chemically-clean glass ampoule according to highly detailed procedure.

Toth, L. R.↗

Fuel-cell heat and mass plate

Plate, serving as heat pipe, can be built into cell to control temperature and water inventory. Plate consists of matrix, filled with liquid water, and a space, filled with water vapor. Both matrix and space extend beyond fuel-cell stack so heat and water may be removed as necessary.

Asher, W. J.↗

Study of low gravity propellant transfer

The results are presented of a program to perform an analytical assessment of potential methods for replenishing the auxiliary propulsion, fuel cell and life support cryogens which may be aboard an orbiting space station. The fluids involved are cryogenic H2, O2, and N2. A complete transfer system was taken to consist of supply storage, transfer, and receiver tank fluid conditioning (pressure and temperature control). In terms of supply storage, the basic systems considered were high pressure (greater than critical), intermediate pressure (less than critical), and modular (transfer of the tanks). Significant findings are included.

Source record↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

An experimental sterilization facility was developed to simulate conditions that will be encountered during terminal sterilization of space vehicles. The system consists of a temperature controlled oven with a nitrogen gas stream containing a known concentration of water. Moisture analyzers are utilized to monitor the gas flowing over spore samples contained in the oven. In its original configuration, no provision was made for the control of water vapor during the sterilization cycle. Because moisture profoundly influences the thermal inactivation of bacterial spores, an upper limit for the moisture content in the gas used to sterilize the space vehicle was established (25% RH at 0 C STP). Accordingly, a controller was developed and installed to provide these conditions in the experimental sterilization facility.

Wimsatt, J. C.↗

Optical modulator system

The fabrication, test, and delivery of an optical modulator system which will operate with a mode-locked Nd:YAG laser indicating at either 1.06 or 0.53 micrometers is discussed. The delivered hardware operates at data rates up to 400 Mbps and includes a 0.53 micrometer electrooptic modulator, a 1.06 micrometer electrooptic modulator with power supply and signal processing electronics with power supply. The modulators contain solid state drivers which accept digital signals with MECL logic levels, temperature controllers to maintain a stable thermal environment for the modulator crystals, and automatic electronic compensation to maximize the extinction ratio. The modulators use two lithium tantalate crystals cascaded in a double pass configuration. The signal processing electronics include encoding electronics which are capable of digitizing analog signals between the limit of + or - 0.75 volts at a maximum rate of 80 megasamples per second with 5 bit resolution. The digital samples are serialized and made available as a 400 Mbps serial NRZ data source for the modulators. A pseudorandom (PN) generator is also included in the signal processing electronics. This data source generates PN sequences with lengths between 31 bits and 32,767 bits in a serial NRZ format at rates up to 400 Mbps.

Brand, J.↗