Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A technique to correct for sample thickness variations for use with IDAPS X-ray radiograph analysis

The Image Data Processing System (IDAPS) at the Marshall Space Flight Center is used to analyze radiographs of metal samples to qualitatively and quantitatively map compositional variations across the samples. When the X-ray radiographs are of samples having thickness variations, corrections must be made to accomplish compositional analysis. A correction technique is described for cylindrical samples and is applied to radiographs of SPAR Experiment 74-18. Uncorrected and corrected images are shown.

Schafer, C. F.↗

Image processing in remote sensing data analysis - The state of the art

Image analysis techniques applicable to remote sensing data and covering image models, feature detection, segmentation and classification, texture analysis, and matching are studied. Model types for characterizing images examined include random-field, mosaic, and facet models. Edge and corner detection as well as global extraction of linear features are discussed. Pixel clustering and classification are covered in addition to the regional approach to segmentation. Autocorrelation, second-order gray level probability density, and the use of primitive element statistics are discussed in relation to texture analysis. Finally, reducing the cost of (sub)imaging matching methods (e.g., pixelwise comparison of gray levels and normalized cross-correlation between two images) as well as improving match sharpness is considered.

Rosenfeld, A.↗

Density Change of an Oxidized Nuclear Graphite by Acoustic Microscopy and Image Processing

The strong correlation between the density and the physical and mechanical properties of graphite suggests that the method of nondestructive density evaluation could be developed into a characterization technique of great value for the overall improvement of safety of graphite moderator reactors. In this study, the oxidation-induced density changes in nuclear graphite for VHTR were determined by a conventional destructive bulk density measurement method (BM), and by a new non-destructive method based on acoustic microscopy and image processing (AM). The results were compared in order to validate the applicability of the latter method. For a direct comparison of the results from both measurements, two specimens were prepared from a cylindrical graphite sample (1 inch diameter and 1 inch height, oxidized to 10% weight loss at 700 oC in air for 5 hours). The specimens were used for characterization by BM and AM methods, respectively. The results show that, even with a large standard deviation of the AM, the density changing trend from both methods appeared the same. Present observation may be attributed to the fact that AM images reflect characteristic density changes of the graphite sample through the acoustic impedance changes. This study demonstrates the possibility of using AM as a nondestructive technique for the evaluation of density changes in graphite when a database is prepared through a systematic series of experiments.

36 MATERIALS SCIENCE↗

SPITZER 70 AND 160 {mu}m OBSERVATIONS OF THE COSMOS FIELD

We present Spitzer 70 and 160 {mu}m observations of the COSMOS Spitzer survey (S-COSMOS). The data processing techniques are discussed for the publicly released products consisting of images and source catalogs. We present accurate 70 and 160 {mu}m source counts of the COSMOS field and find reasonable agreement with measurements in other fields and with model predictions. The previously reported counts for GOODS-North and the extragalactic First Look Survey are updated with the latest calibration, and counts are measured based on the large area SWIRE survey to constrain the bright source counts. We measure an extragalactic confusion noise level of {sigma} {sub c} = 9.4 {+-} 3.3 mJy (q = 5) for the MIPS 160 {mu}m band based on the deep S-COSMOS data and report an updated confusion noise level of {sigma} {sub c} = 0.35 {+-} 0.15 mJy (q = 5) for the MIPS 70 {mu}m band.

79 ASTRONOMY AND ASTROPHYSICS↗

Compression Techniques for Improved Algorithm Computational Performance

Analysis of thermal data requires the processing of large amounts of temporal image data. The processing of the data for quantitative information can be time intensive especially out in the field where large areas are inspected resulting in numerous data sets. By applying a temporal compression technique, improved algorithm performance can be obtained. In this study, analysis techniques are applied to compressed and non-compressed thermal data. A comparison is made based on computational speed and defect signal to noise.

Zalameda, Joseph N.↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗

FEASIBILITY OF HELIOSPHERIC IMAGING FROM NEAR EARTH

Imaging solar wind structures via Thomson scattered sunlight has proved important to understanding the inner heliosphere. The principal challenge of heliospheric imaging is background subtraction: typical solar wind features are fainter than the zodiacal light and starfield by 2-3 orders of magnitude. Careful post-processing is required to separate the solar wind signal from the static background. Remnant background, and not photon noise, is the dominant noise source in current STEREO data. We demonstrate that 10× shorter exposure times would not strongly affect the noise level in these data. Further, we demonstrate that current processing techniques are sufficient to separate not only the existing background of the STEREO images but also diffuse variable backgrounds such as are expected to be seen from low Earth orbit. We report on a hare-and-hounds style study, demonstrating blind signal extraction from STEREO/HI-2 data that have been degraded by the addition of large-scale, time-dependent artifacts to simulate viewing through airglow or high-altitude aurora. We demonstrate removal of these effects via image processing, with little degradation compared to the original. Even with as few as three highly degraded source images over 48 hr, it is possible to detect and track large coronal mass ejections more than 40° from the Sun. This implies that neither the high altitude aurora discovered by Coriolis/SMEI, nor airglow effects seen from low Earth orbit, are impediments to a hypothetical next-generation heliospheric imager in low Earth orbit; and also that post-processing is as important to heliospheric image qualitiy as are optical contamination effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Cardiovascular Imaging and Image Processing: Theory and Practice - 1975

Ultrasonography was examined in regard to the developmental highlights and present applicatons of cardiac ultrasound. Doppler ultrasonic techniques and the technology of miniature acoustic element arrays were reported. X-ray angiography was discussed with special considerations on quantitative three dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body. Nuclear cardiography and scintigraphy, three--dimensional imaging of the myocardium with isotopes, and the commercialization of the echocardioscope were studied.

Harrison, Donald C.↗

Multidimensional Processing and Visual Rendering of Complex 3D Biomedical Images

The proposed technology uses advanced image analysis techniques to maximize the resolution and utility of medical imaging methods being used during spaceflight. We utilize COTS technology for medical imaging, but our applications require higher resolution assessment of the medical images than is routinely applied with nominal system software. By leveraging advanced data reduction and multidimensional imaging techniques utilized in analysis of Planetary Sciences and Cell Biology imaging, it is possible to significantly increase the information extracted from the onboard biomedical imaging systems. Year 1 focused on application of these techniques to the ocular images collected on ground test subjects and ISS crewmembers. Focus was on the choroidal vasculature and the structure of the optic disc. Methods allowed for increased resolution and quantitation of structural changes enabling detailed assessment of progression over time. These techniques enhance the monitoring and evaluation of crew vision issues during space flight.

Sams, Clarence F.↗

WE-E-18A-07: MAGIC: Multi-Acquisition Gain Image Correction for Mobile X-Ray Systems with Intrinsic Localization Crosshairs

Purpose: Gain calibration for X-ray imaging systems with movable flat panel detectors (FPD) and intrinsic crosshairs is a challenge due to the geometry dependence of the heel effect and crosshair artifact. This study aims to develop a gain correction method for such systems by implementing the multi-acquisition gain image correction (MAGIC) technique. Methods: Raw flat-field images containing crosshair shadows and heel effect were acquired in 4 different FPD positions with fixed exposure parameters. The crosshair region was automatically detected and substituted with interpolated values from nearby exposed regions, generating a conventional single-image gain-map for each FPD position. Large kernel-based correction was applied to these images to correct the heel effect. A mask filter was used to invalidate the original cross-hair regions previously filled with the interpolated values. A final, seamless gain-map was created from the processed images by either the sequential filling (SF) or selective averaging (SA) techniques developed in this study. Quantitative evaluation was performed based on detective quantum efficiency improvement factor (DQEIF) for gain-corrected images using the conventional and proposed techniques. Results: Qualitatively, the MAGIC technique was found to be more effective in eliminating crosshair artifacts compared to the conventional single-image method. The mean DQEIF over the range of frequencies from 0.5 to 3.5 mm-1 were 1.09±0.06, 2.46±0.32, and 3.34±0.36 in the crosshair-artifact region and 2.35±0.31, 2.33±0.31, and 3.09±0.34 in the normal region, for the conventional, MAGIC-SF, and MAGIC-SA techniques, respectively. Conclusion: The introduced MAGIC technique is appropriate for gain calibration of an imaging system associated with a moving FPD and an intrinsic crosshair. The technique showed advantages over a conventional single image-based technique by successfully reducing residual crosshair artifacts, and higher image quality with respect to DQE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of ILLIAC 4 algorithms for multispectral image interpretation

Research has focused on the design and partial implementation of a comprehensive ILLIAC software system for computer-assisted interpretation of multispectral earth resources data such as that now collected by the Earth Resources Technology Satellite. Research suggests generally that the ILLIAC 4 should be as much as two orders of magnitude more cost effective than serial processing computers for digital interpretation of ERTS imagery via multivariate statistical classification techniques. The potential of the ARPA Network as a mechanism for interfacing geographically-dispersed users to an ILLIAC 4 image processing facility is discussed.

Ray, R. M.↗

Time Resolution of Fast Photomultipliers for Time of Flight PET

Time resolution study of 1 inch Photonis XP1020 photomultiplier is reported. The number of photoelectrons, time jitter and time resolution with 4x4x20 mm{sup 3} LSO crystal were measured. All the mentioned PMT properties were measured at five positions on the photocathode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase retrieval tomography in the presence of noise

We describe the use of single-plane phase retrieval tomography using a laboratory-based x-ray source, under conditions where the retrieval is not formally valid, to present images of the internal structure of an Aerosil granule and a hydrated bentonite gel. The technique provides phase images for samples that interact weakly with the x-ray beam. As the method is less affected by noise than an alternative two-plane phase retrieval method that is otherwise formally valid, object structure can be observed that would not otherwise be seen. We demonstrate our results for phase imaging in tomographic measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Variational and Shape Prior-based Level Set Model for Image Segmentation

A new image segmentation model based on level sets approach is presented herein. We deal with radiographic medical images where boundaries are not salient, and objects of interest have the same gray level as other structures in the image. Thus, an a priori information about the shape we look for is integrated in the level set evolution for good segmentation results. The proposed model also accounts a penalization term that forces the level set to be close to a signed distance function (SDF), which then avoids the re-initialization procedure. In addition, a variant and complete Mumford-Shah model is used in our functional; the added Hausdorff measure helps to better handle zones where boundaries are occluded or not salient. Finally, a weighted area term is added to the functional to make the level set drive rapidly to object's boundaries. The segmentation model is formulated in a variational framework, which, thanks to calculus of variations, yields to partial differential equations (PDEs) to guide the level set evolution. Results obtained on both synthetic and digital radiographs reconstruction (DRR) show that the proposed model improves on existing prior and non-prior shape based image segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THREE-DIMENSIONAL DOPPLER TOMOGRAPHY OF THE RS VULPECULAE INTERACTING BINARY

Three-dimensional Doppler tomography has been used to study the H{alpha} emission sources in the RS Vulpeculae (RS Vul) interacting binary. The two-dimensional tomogram of this binary suggested that most of the emission arises from the cool mass losing star with additional evidence of a gas stream flowing close to its predicted trajectory. However, the three-dimensional tomogram revealed surprising evidence that the gas stream has an average velocity of -85 km s{sup -1} relative to the central velocity plane at V{sub z} = 0 km s{sup -1}, unlike U CrB in which the stream was prominent along this central plane. These unexpected V{sub z} motions may result from the interaction between magnetic activity on the cool star and the gravitationally induced Roche lobe overflow from that star. Evidence of a loop prominence on the cool star close to the L1 point has been found in the three-dimensional tomogram of RS Vul; hence, the magnetic field lines may have deflected the gas stream relative to the central plane. This result is consistent with earlier detections of RS Vul as both an X-ray and a radio source, and represents the first detection of a loop prominence in an interacting binary based on tomography. Moreover, recent radio images of {beta} Per, the prototype of the Algols, show that the magnetic field of the mass losing star is asymmetric and extends well beyond the orbital plane of the binary, so it is now plausible that the gas flow between the stars in RS Vul could be deflected in an asymmetric way by the magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ERTS direct readout ground station study

A system configuration which provides for a wide variety of user requirements is described. Two distinct user types are considered and optimized configurations are provided. Independent satellite transmission systems allow simultaneous signal transmission to Regional Collection Centers via a high data rate channel and to local users who require near real time consumption of lower rate data. In order to maximize the ultimate utility of this study effort, a parametric system description is given such that in essence a shopping list is provided. To achieve these results, it was necessary to consider all technical disciplines associated with high resolution satellite imaging systems including signal processing, modulation and coding, recording, and display techniques. A total systems study was performed.

Source record↗

Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.↗