Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “switching frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Survey Strategy Optimization for the Atacama Cosmology Telescope

In recent years there have been significant improvements in the sensitivity and the angular resolution of the instruments dedicated to the observation of the Cosmic Microwave Background (CMB). ACTPol is the first polarization receiver for the Atacama Cosmology Telescope (ACT) and is observing the CMB sky with arcmin resolution over approximately 2000 square degrees. Its upgrade, Advanced ACTPol (AdvACT), will observe the CMB in five frequency bands and over a larger area of the sky. We describe the optimization and implementation of the ACTPol and AdvACT surveys. The selection of the observed fields is driven mainly by the science goals, that is, small angular scale CMB measurements, B-mode measurements and cross-correlation studies. For the ACTPol survey we have observed patches of the southern galactic sky with low galactic foreground emissions which were also chosen to maximize the overlap with several galaxy surveys to allow unique cross-correlation studies. A wider field in the northern galactic cap ensured significant additional overlap with the BOSS spectroscopic survey. The exact shapes and footprints of the fields were optimized to achieve uniform coverage and to obtain cross-linked maps by observing the fields with different scan directions. We have maximized the efficiency of the survey by implementing a close to 24-hour observing strategy, switching between daytime and nighttime observing plans and minimizing the telescope idle time. We describe the challenges represented by the survey optimization for the significantly wider area observed by AdvACT, which will observe roughly half of the low-foreground sky. The survey strategies described here may prove useful for planning future ground-based CMB surveys, such as the Simons Observatory and CMB Stage IV surveys.

Atacama Cosmology Telescope (ACT)↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Thermal Control using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infrared region is examined in this study. The device consisted of a transparent conductor, WO3 anode, PMMA/LiClO4 electrolyte, V2O5 cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8V to 1.8V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8V with a transmittance of 5% at a wavelength, lambda=900 nm and colorless at -0.8V with a transmittance of 74% at lambda=500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is 75 seconds for transmittance to decrease from 74% to 50%. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8V and -0.8V, respectively.

Vaidyanathan, Hari↗

Thermal Control Using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infrared region is examined in this study. The device consisted of a transparent conductor, WO3, anode, PMMA/LiClO4 electrolyte, V2O5 cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8V to 1.8V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8 V with a transmittance of 5% at a wavelength, lambda = 900 nm and colorless at -0.8 V with a transmittance of 74% at lambda = 500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is a function of temperature and time for coloring reaction was slower than the bleaching reaction. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8V and -0.8V, respectively.

Vaidyanathan, Hari↗

Thermal Control Using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infra red region is examined in this study. The device consisted of a transparent conductor, WO3 anode, PMMA/LiClO4, electrolyte, V2O5, cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8 V to 1.8 V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8 V with a transmittance of 5% at a wavelength, lambda = 900 nm and colorless at -0.8 V with a transmittance of 74% at X = 500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is 75 seconds for transmittance to decrease from 74% to 50%. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8 V and -0.8 V, respectively.

Vaidyanathan, Hari↗

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

Flight Test of an Intelligent Flight-Control System

The F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) airplane (see figure) was the test bed for a flight test of an intelligent flight control system (IFCS). This IFCS utilizes a neural network to determine critical stability and control derivatives for a control law, the real-time gains of which are computed by an algorithm that solves the Riccati equation. These derivatives are also used to identify the parameters of a dynamic model of the airplane. The model is used in a model-following portion of the control law, in order to provide specific vehicle handling characteristics. The flight test of the IFCS marks the initiation of the Intelligent Flight Control System Advanced Concept Program (IFCS ACP), which is a collaboration between NASA and Boeing Phantom Works. The goals of the IFCS ACP are to (1) develop the concept of a flight-control system that uses neural-network technology to identify aircraft characteristics to provide optimal aircraft performance, (2) develop a self-training neural network to update estimates of aircraft properties in flight, and (3) demonstrate the aforementioned concepts on the F-15 ACTIVE airplane in flight. The activities of the initial IFCS ACP were divided into three Phases, each devoted to the attainment of a different objective. The objective of Phase I was to develop a pre-trained neural network to store and recall the wind-tunnel-based stability and control derivatives of the vehicle. The objective of Phase II was to develop a neural network that can learn how to adjust the stability and control derivatives to account for failures or modeling deficiencies. The objective of Phase III was to develop a flight control system that uses the neural network outputs as a basis for controlling the aircraft. The flight test of the IFCS was performed in stages. In the first stage, the Phase I version of the pre-trained neural network was flown in a passive mode. The neural network software was running using flight data inputs with the outputs provided to instrumentation only. The IFCS was not used to control the airplane. In another stage of the flight test, the Phase I pre-trained neural network was integrated into a Phase III version of the flight control system. The Phase I pretrained neural network provided realtime stability and control derivatives to a Phase III controller that was based on a stochastic optimal feedforward and feedback technique (SOFFT). This combined Phase I/III system was operated together with the research flight-control system (RFCS) of the F-15 ACTIVE during the flight test. The RFCS enables the pilot to switch quickly from the experimental- research flight mode back to the safe conventional mode. These initial IFCS ACP flight tests were completed in April 1999. The Phase I/III flight test milestone was to demonstrate, across a range of subsonic and supersonic flight conditions, that the pre-trained neural network could be used to supply real-time aerodynamic stability and control derivatives to the closed-loop optimal SOFFT flight controller. Additional objectives attained in the flight test included (1) flight qualification of a neural-network-based control system; (2) the use of a combined neural-network/closed-loop optimal flight-control system to obtain level-one handling qualities; and (3) demonstration, through variation of control gains, that different handling qualities can be achieved by setting new target parameters. In addition, data for the Phase-II (on-line-learning) neural network were collected, during the use of stacked-frequency- sweep excitation, for post-flight analysis. Initial analysis of these data showed the potential for future flight tests that will incorporate the real-time identification and on-line learning aspects of the IFCS.

Davidson, Ron↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights on the Influence of the Central-Cut Width of the Box Assembly with Removable Component on Its Dynamical Responses

This investigation focuses on the dynamical effects caused by varying the central-cut width within the Box Assembly with Removable Component (BARC) system. The central-cut widths included in this study are a 0.5″ cut, a 0.25″ cut, a thin 0.1″ cut, and a structure that did not have a cut at all. Finite element analysis was conducted to determine the mode shapes and natural frequencies of each of the BARC structures. Structural dynamics experiments were run to examine the effects of the central-cut width on the dynamical responses and nonlinear characteristics of the BARC system. Free vibration testing with an impact hammer was carried out to excite the system and extract the dominant frequencies and directions of the significant responses. A pseudorandom vibration test that allows for the qualitative determination of any nonlinear behavior within the system was performed. This type of behavior can include nonlinear softening, nonlinear hardening, and the most common, nonlinear damping due to the presence of several bolted-joint connections and the possible activation of geometric and inertia nonlinearities. To quantitatively investigate the impacts of the central-cut width on the dynamics of the system, swept sinusoidal testing was conducted. It is determined that almost all systems with central cuts demonstrate the presence of nonlinear softening, but at times, nonlinear hardening trends are seen, particularly in the 0.1″ cut and no-cut systems when testing harmonically. Each of the central-cut systems displays nonlinear damping, with the amount of damping generally increasing as the central cut decreases in size. The effect of the central cut of the BARC system on the mode-switching ability of the system is negligible; however, mode switching takes place when comparing the central-cut configurations to the no-cut one. These results show the significance of accurately measuring the central-cut width and how geometric uncertainty may change the dynamical responses and nonlinear properties of the system.

Padilla, Christopher (ORCID:000900033446732X)↗

Optimization of microscopic and macroscopic second order optical nonlinearities

Nonlinear optical materials (NLO) can be used to extend the useful frequency range of lasers. Frequency generation is important for laser-based remote sensing and optical data storage. Another NLO effect, the electro-optic effect, can be used to modulate the amplitude, phase, or polarization state of an optical beam. Applications of this effect in telecommunications and in integrated optics include the impression of information on an optical carrier signal or routing of optical signals between fiber optic channels. In order to utilize these effects most effectively, it is necessary to synthesize materials which respond to applied fields very efficiently. In this talk, it will be shown how the development of a fundamental understanding of the science of nonlinear optics can lead to a rational approach to organic molecules and materials with optimized properties. In some cases, figures of merit for newly developed materials are more than an order of magnitude higher than those of currently employed materials. Some of these materials are being examined for phased-array radar and other electro-optic switching applications.

Marder, Seth R.↗

Diaphragm Pump With Resonant Piezoelectric Drive

A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to make it oscillate at the resonance frequency of the spring and- mass structure. This frequency could be made high enough (of the order of 400 Hz) that the masses of all components could be made conveniently small. The resonance would amplify the relatively small motion of the piezoelectric stack (a stroke of the order of 10 m) to a diaphragm stroke of the order of 0.5 mm. The exact amplification factor would depend on the rate of damping of oscillations; this, in turn, would depend on details of design and operation, including (but not limited to) the desired pressure rise and volumetric flow rate. In order to obtain resonance with large displacement, the damping rate must be low enough that the energy imparted to the pumped fluid on each stroke is much less than the kinetic and potential energy exchanged between the mass and spring during each cycle of oscillation. To minimize the power demand of the pump, a highly efficient drive circuit would be used to excite the piezoelectric stack. This circuit (see Figure 2) would amount to a special-purpose regenerative, switching power supply that would operate in a power-source mode during the part of an oscillation cycle when the excitation waveform was positive and in a power-recovery mode during the part of the cycle when the excitation waveform was negative. The circuit would include a voltage-boosting dc-to-dc converter that would convert between a supply potential of 24 Vdc and the high voltage needed to drive the piezoelectric stack. Because of the power-recovery feature, the circuit would consume little power. It should be possible to build the circuit as a compact unit, using readily available components.

Izenson, Michael G.↗

Programmable hyperbolic polaritons in van der Waals semiconductors

Lighting a route for hyperbolic dispersion The propagation of light within a material is usually well defined, with the propagation described by scattering and dispersion. In artificially designed metamaterials and in anisotropic layered materials, the dispersion can be hyperbolic, giving rise to subwavelength confinement of the light. Sternbach et al. show that the hyperbolic dispersion can be optically switched on and off on demand in the layered transition metal dichalcogenide tungsten diselenide (see the Perspective by Deng and Chen). Illuminating the material with ultrafast pulses of sub-bandgap light creates a transient waveguide, resulting in hyperbolic dispersion in the material. The ability to tune the dispersion characteristics on demand using optical pumping is an effective approach for developing ultrafast switching photonic devices and controlling the propagation of light on the nanoscale. Science , this issue p. 617 ; see also p. 572

Science & Technology - Other Topics↗

Progress on the Plasmoid Thruster Experiment (PTX)

A plasmoid, also called a compact toroid, is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic field (Bp and Bt, respectively). An object with Bp/Bt much greater than 1 is called a Field Reverse Configuration (FRC); if Bp = Bt, it is called a Spheromak. The plasmoid thruster is a pulsed inductive device which operates by repetitively producing plasmoids that are accelerated and ejected at high velocity. As the process is inductive, this thruster avoids the problem of electrode erosion. Also, the magnetic structure of the plasmoid should suppress thermal and mass losses to the wall, and improve detachment of the plasma exhaust from the thruster. This concept should be capable of producing an Isp of 5,000 seconds and greater, with thrust densities of order 10(exp 5) N/sq m. The plasmoid thruster consists chiefly of a conical theta-pinch coil. Propellant is introduced onto a bias magnetic field, produced by an auxiliary coil, and is then pre-ionized, freezing in the magnetic field. The theta-pinch coil is then energized producing a field aligned anti- parallel to the bias field. The reversed field reconnects with the bias field to form the plasmoid. The magnetic pressure of the reversed field accelerates the plasmoid out of the thruster . A series of experiments have been conducted on the PTX device, which consisted of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank, which rang at a frequency of 500 kHz, and served all three functions required for formation: pre-ionization, bias field loading, and field reversal. Initial ionization was found to occur in an annular region at the exit plane of the coil, and was found to be reproducible with a variety of gases, including H2, D2, Ar, and an H2/N2 mixture (75% / 25%). A fast gas valve for injecting propellant has been tested, as well as a ringing pre-ionization circuit (operating at 5 Mhz) to better control the plasmoid formation. Velocities as high as 20 km/s have been measured for a plasmoid propagating into a static back-fill of neutral gas. Magnetic field and density measurements indicate that the plasmoid retains its structure well into the down-stream exhaust region, and that it is capable of pushing a dense cloud of neutral gas in front of it. Further experiments will focus on the effects of coil geometry and bias-field strength on the performance of the device. A high-power solid-state switching system is being developed in order to replace the spark-gap switch.

Martin, Adam↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Sub‐Nanosecond Reconfiguration of Ferroelectric Domains in Bismuth Ferrite

Abstract Domain switching is crucial for achieving desired functions in ferroic materials that are used in various applications. Fast control of domains at sub‐nanosecond timescales remains a challenge despite its potential for high‐speed operation in random‐access memories, photonic, and nanoelectronic devices. Here, ultrafast laser excitation is shown to transiently melt and reconfigure ferroelectric stripe domains in multiferroic bismuth ferrite on a timescale faster than 100 picoseconds. This dynamic behavior is visualized by picosecond‐ and nanometer‐resolved X‐ray diffraction and time‐resolved X‐ray diffuse scattering. The disordering of stripe domains is attributed to the screening of depolarization fields by photogenerated carriers resulting in the formation of charged domain walls, as supported by phase‐field simulations. Furthermore, the recovery of disordered domains exhibits subdiffusive growth on nanosecond timescales, with a non‐equilibrium domain velocity reaching up to 10 m s −1 . These findings present a new approach to image and manipulate ferroelectric domains on sub‐nanosecond timescales, which can be further extended into other complex photoferroic systems to modulate their electronic, optical, and magnetic properties beyond gigahertz frequencies. This approach could pave the way for high‐speed ferroelectric data storage and computing, and, more broadly, defines new approaches for visualizing the non‐equilibrium dynamics of heterogeneous and disordered materials.

36 MATERIALS SCIENCE↗

Control of Cavity Resonance Using Oscillatory Blowing

The near-zero net mass oscillatory blowing control of a subsonic cavity flow has been experimentally investigated. An actuator was designed and fabricated to provide both steady and oscillatory blowing over a range of blowing amplitudes and forcing frequencies. The blowing was applied just upstream of the cavity front Wall through interchangeable plate configurations These configurations enabled the effects of hole size, hole shape, and blowing angle to be examined. A significant finding is that in terms of the blowing amplitude, the near zero net mass oscillatory blowing is much more effective than steady blowing; momentum coefficients Lip two orders of magnitude smaller than those required for steady blowing are sufficient to accomplish the same control of cavity resonance. The detailed measurements obtained in the experiment include fluctuating pressure data within the cavity wall, and hot-wire measurements of the cavity shear layer. Spectral and wavelet analysis techniques are applied to understand the dynamics and mechanisms of the cavity flow with control. The oscillatory blowing, is effective in enhancing the mixing in the cavity shear layer and thus modifying the feedback loop associated with the cavity resonance. The nonlinear interactions in the cavity flow are no longer driven by the resonant cavity modes but by the forcing associated with the oscillatory blowing. The oscillatory blowing does not suppress the mode switching behavior of the cavity flow, but the amplitude modulation is reduced.

Scarfe, Alison Lamp↗