Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Improved genome annotation through untargeted detection of pathway-specific metabolites

Background: Mass spectrometry-based metabolomics analyses have the potential to complement sequence-based methods of genome annotation, but only if raw mass spectral data can be linked to specific metabolic pathways. In untargeted metabolomics, the measured mass of a detected compound is used to define the location of the compound in chemical space, but uncertainties in mass measurements lead to “degeneracies” in chemical space since multiple chemical formulae correspond to the same measured mass. We compare two methods to eliminate these degeneracies. One method relies on natural isotopic abundances, and the other relies on the use of stableisotope labeling (SIL) to directly determine C and N atom counts. Both depend on combinatorial explorations of the “chemical space” comprised of all possible chemical formulae comprised of biologically relevant chemical elements. Results: Of 1532 metabolic pathways curated in the MetaCyc database, 412 contain a metabolite having a chemical formula unique to that metabolic pathway. Thus, chemical formulae alone can suffice to infer the presence of some metabolic pathways. Of 248,928 unique chemical formulae selected from the PubChem database, more than 95% had at least one degeneracy on the basis of accurate mass information alone. Consideration of natural isotopic abundance reduced degeneracy to 64%, but mainly for formulae less than 500 Da in molecular weight, and only if the error in the relative isotopic peak intensity was less than 10%. Knowledge of exact C and N atom counts as determined by SIL enabled reduced degeneracy, allowing for determination of unique chemical formula for 55% of the PubChem formulae. Conclusions: To facilitate the assignment of chemical formulae to unknown mass-spectral features, profiling can be performed on cultures uniformly labeled with stable isotopes of nitrogen (15N) or carbon (13C). This makes it possible to accurately count the number of carbon and nitrogen atoms in each molecule, providing a robust means for reducing the degeneracy of chemical space and thus obtaining unique chemical formulae for features measured in untargeted metabolomics having a mass greater than 500 Da, with relative errors in measured isotopic peak intensity greater than 10%, and without the use of a chemical formula generator dependent on heuristic filtering. These chemical formulae can serve as indicators for the presence of particular metabolic pathways.

59 BASIC BIOLOGICAL SCIENCES↗

FUN with PANURGE - High mass resolution ion microprobe measurements of Mg in Allende inclusions

Isotopic ratios have been determined, at a precision level approaching that of counting statistics using beam switching, by employing PANURGE, a modified CAMECA IMS3F ion microprobe at a mass resolving power of 5000. This technique is used to determine the isotopic composition of Mg and Si and the atomic ratio of Al/Mg in minerals from the Allende inclusion WA and the Allende FUN inclusion C1. Results show enrichment in Mg-26 of up to 260 percent. Results of Mg and Al/Mg measurements on cogenetic spinel inclusion and host plagiclase crystals show Mg-Al isochrons in excellent agreement with precise mineral isochrons determined by thermal emission mass spectrometry. The measurements are found to confirm the presence of substantial excess Mg-26 in WA and its near absence in C1. Data is obtained which indicates a metamorphic reequilibrium of Mg in Allende plagioclase at least 0.6 my after WA formation. Ion probe measurements are obtained which confirm that the Mg composition in Allende C1 is highly fractionated and is uniform among pyroxene, melilite, plagioclase, spinel crystals, and spinel included in melilite and plagioclase crystals.

Huneke, J. C.↗

An upper limit for the rate coefficient of the reaction of NH2 radicals with O2 using FTIR product analysis

Fourier transform infrared spectrometry has been used to study the products of the photooxidation of ammonia in the presence of oxygen at 296 K. The data have been used to derive an upper limit of 6 x 10 exp -21/cu cm molecule s for the reaction of NH2 radicals with O2 to produce NO(x) at 296 K. This upper limit, which is three orders of magnitude lower than previous estimates based on the kinetics of NH2 loss, rules out the importance of this reaction in the atmosphere and suggests that NH2 will be oxidized by O3 or NO2. The effect on the NO(x) and N2O budgets depends critically on the products of the NH2 + O3 reaction. Simulations of the experimental product yields also allow an evaluation of possible product channels for the reaction of NH2 with HO2.

Tyndall, G. S.↗

Absolute intensities and foreign gas broadening coefficients of the 11(sub 1,10) from 11(sub 2,10) and 18(sub 0,18) from 18(sub 1,18) lines in the nu(sub 7) band of C2H4

Absolute intensities and foreign gas broadening coefficients of the 18(sub 0,18) from 18(sub 1,18) and 11(sub 1,10) from 11(sub 2,10) transitions in the nu(sub 7) band of C2H4 near 948/cm have been measured at a spectral resolution of approximately 5 x 10(exp -4)/cm using tunable diode laser spectrometry. Ar, He, N2, O2 were used as the broadening gases. In order to determine the temperature dependence of the broadening coefficient, data were obtained at temperatures ranging from 150 to 296 K. The absolute intensity of the 5(sub 0,5) from 5(sub 1,5) transition was also found at 296 K. A band strength of 330 +/- 10/sq cm/atm was obtained from weighted averages of the individual line intensities and a rigid asymmetric top calculation.

Reuter, Dennis C.↗

Synthesis and characterization of N-parinaroyl analogs of ganglioside GM3 and de-N-acetyl GM3. Interactions with the EGF receptor kinase

A specific plasma membrane glycosphingolipid, known as ganglioside GM3, can regulate the intrinsic tyrosyl kinase activity of the epidermal growth factor (EGF) receptor; this modulation is not associated with alterations in hormone binding to the receptor. GM3 inhibits EGF receptor tyrosyl kinase activity in detergent micelles, in plasma membrane vesicles, and in whole cells. In addition, immunoaffinity-purified EGF receptor preparations contain ganglioside GM3 (Hanai et al. (1988) J. Biol. Chem. 263, 10915-10921), implying that the glycosphingolipid is intimately associated with the receptor kinase in cell membranes. Both the nature of this association and the molecular mechanism of kinase inhibition remain to be elucidated. In this report, we describe the synthesis of a fluorescent analog of ganglioside GM3, in which the native fatty acid was replaced with trans-parinaric acid. This glycosphingolipid inhibited the receptor kinase activity in a manner similar to that of the native ganglioside. A modified fluorescent glycosphingolipid, N-trans-parinaroyl de-N-acetyl ganglioside GM3, was also prepared. This analog, like the nonfluorescent de-N-acetyl ganglioside GM3, had no effect on receptor kinase activity. Results from tryptophan fluorescence quenching and steady-state anisotropy measurements in membranes containing these fluorescent probes and the human EGF receptor were consistent with the notion that GM3, but not de-N-acetyl GM3, interacts specifically with the receptor in intact membranes.

NASA Discipline Cell Biology↗

Characterization of a New Lead Slowing Down Spectrometer

There is considerable interest in developing direct measurement methods to determine the plutonium content of spent nuclear fuel within a fuel assembly. One technique that may prove successful is lead slowing-down spectroscopy. Lead Slowing Down Spectroscopy (LSDS) has been used for decades to make cross-section measurements on relatively small isotopic samples of well know masses. For spent fuel assembly measurements, LSDS will be applied in reverse; unknown masses will be determined using well-know cross-sections. In the LSDS, a pulse of neutrons (on the order of 10-100 MeV) is injected into a large lead stack (~ 1m3). The neutrons quickly down-scatter but exhibit little spread in energy about the average, continually-decreasing neutron energy making for a strong correlation between the elapsed time from the initial pulse and the average energy of the neutron. By measuring this elapsed time, it is possible to measure interactions of the neutrons with the fuel in the 0.1 to 1,000 eV range. Many of the actinides have strong resonances in this region, making it possible, through careful measurements and analysis, to extract isotopic masses from LSDS measurements. Pacific Northwest National Laboratory is actively conducting research on both LSDS measurement and data analysis techniques. This paper will present results of the effort to construct and characterize a new lead slowing down spectrometer. The spectrometer was designed to begin testing both experimental measurement and data analysis techniques for determining the plutonium content of spent fuel. To characterize the spectrometer, a series of (n,γ) experiments were conducted to measure the correlation between the time after the neutrons enter the lead and the energy of the interaction. Results from these measurements as well as plans for future development of the spectrometer will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of multilayered SiGe semiconductor structures by X-ray diffractometry, grazing-incidence X-ray reflectometry, and secondary-ion mass spectrometry

In this publication, we report the results of studying a multilayerd nonperiodic SiGe/Si structure by the methods of X-ray diffractometry, grazing-angle X-ray reflectometry, and secondary-ion mass spectrometry (SIMS). Special attention is paid to the processing of the component distribution profile using the SIMS method and to consideration of the most significant experimental distortions introduced by this method. A method for processing the measured composition distribution profile with subsequent consideration of the influence of matrix effects, variation in the etching rate, and remnants of ion sputtering is suggested. The results of such processing are compared with a structure model obtained upon combined analysis of X-ray diffractometry and grazing-angle reflectometry data. Good agreement between the results is established. It is shown that the combined use of independent techniques makes it possible to improve the methods of secondary-ion mass spectrometry and grazing-incidence reflectometry as applied to an analysis of multilayered heteroepitaxial structures (to increase the accuracy and informativity of these methods)

36 MATERIALS SCIENCE↗

Multivariate Statistical Analysis of Orthogonal Mass Spectral Data for the Identification of Chemical Attribution Signatures of 3-Methylfentanyl

Critical to many modern forensic investigations is the chemical attribution of the origin of an illegal drug. This process greatly relies on identification of compounds indicative of its clandestine or commercial production. The results of these studies can yield detailed information on method of manufacture, sophistication of the synthesis operation, starting material source, and final product. In the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic 3- methylfentanyl, N-(3-methyl-1-phenethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Six synthesis methods were studied in an effort to identify and classify route-specific signatures. These methods were chosen to minimize the use of scheduled precursors, complicated laboratory equipment, number of overall steps, and demanding reaction conditions. Using gas and liquid chromatographies combined with mass spectrometric methods (GC-QTOF and LC-QTOF) in conjunction with inductivelycoupled plasma mass spectrometry (ICP-MS), over 240 distinct compounds and elements were monitored. As seen in our previous work with CAS of fentanyl synthesis the complexity of the resultant data matrix necessitated the use of multivariate statistical analysis. Using partial least squares discriminant analysis (PLS-DA), 62 statistically significant, route-specific CAS were identified. Statistical classification models using a variety of machine learning techniques were then developed with the ability to predict the method of 3-methylfentanyl synthesis from three blind crude samples generated by synthetic chemists without prior experience with these methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Pre-Corrected Differential Absorption Techniques to Retrieve Columnar Water Vapor: Application to AVIRIS 91/95 Data

Water vapor is one of the main forces for weather development as well as for mesoscale air transport processes. The monitoring of water vapor is therefore an important aim in remote sensing of the atmosphere. Current operational systems for water vapor detection use primarily the emission in the thermal infrared (AVHRR, GOES, ATSR, Meteosat) or in the microwave radiation bands (DMSP). The disadvantage of current satellite systems is either a coarse spatial (horizontal) resolution ranging from one to tens of kilometers or a limited insight into the lower atmosphere. Imaging spectrometry on the other hand measures total column water vapor contents at a high spatial horizontal resolution and has therefore the potential of filling these gaps. The sensors of the AVIRIS instrument are capable of acquiring hyperspectral data in 224 bands located in the visible and near infrared at 10 nm resolution. This data includes the information on constituents of the earth's surface as well as of the atmosphere. The optical measurement of water vapor can be performed using sensor channels located in bands or lines of the absorption spectrum. The AVIRIS sensor has been used to retrieve water vapor and with less accuracy carbon dioxide, oxygen and ozone. To retrieve the water vapor amount, the so called differential absorption technique has been applied. The goal of this technique is to eliminate background factors by taking a ratio between channels within the absorption band and others besides the band. Various ratioing methods on the basis of different channels and calculation techniques were developed. The influence of a trace gas of interest on the radiance at the sensor level is usually simulated by using radiative transfer codes. In this study, the spectral transmittance and radiance are calculated by MODTRAN3 simulations with the new DISORT option. The objective of this work is to test the best performing differential absorption techniques for imaging spectrometry of tropospheric water vapor.

Schlaepfer, Daniel↗

Measurement of the plutonium hold-up in glove box before dismantling - 15111

The French Bruyeres-Le-Chatel CEA (Commissariat a l'Energie Atomique et aux Energies Alternatives - French Alternatives Energies and Atomic Energy Commission) research center is going through a period of cleaning and dismantling of theses old treatment facilities on fissile materials and others associated nuclides. Some very large glove boxes contained some machines like melting furnace which can't be moved and are dismantled in situ. We need to evaluate the quantity of fissile materials to prevent criticality risk, to bring the evidence to the safety authority, to manage for the best the radioprotection of the workers and to manage waste production. A melting furnace in a glove box was dismantled. Measurements by gamma spectrometry with an HPGe detector (High Purity Germanium) and passive neutron counting (coincidence counting with shift register) are done in situ (furnace in the glove box). In order to refine the measurements, some data acquisitions by sector of glove box were carried out. In view of the geometries to characterize, some modelings have been created, in order to correct the different attenuations and to determine the plutonium masses content in the glove box, including the use of infinite energy technique. For the measurement by passive neutron counting (coincidence counting with shift register), we have used two slabs in high density polythene including nine He3 counters in each slab. This measurement technique is complementary to gamma spectrometry, and allows quantizing the fissile material which would be included in interstice of high Z material. The 100-L and 200-L drums produced during the dismantling were also measured. Based on simplified assumptions to analyze in situ measurements, plutonium weight could be evaluated. This approach of measurement in amount, during and after dismantling, has allowed to quantize the fissile material mass present in the glove box and didn't produce waste package which wouldn't respected the technical specifications of storage outlets. The results show good agreement between in situ and waste measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison between design and installed acoustic characteristics of NASA Lewis 9- by 15-foot low-speed wind tunnel acoustic treatment

The test section of the NASA Lewis 9- by 15-Foot Low-Speed Wind Tunnel was acoustically treated to allow the measurement of sound under simulated free-field conditions. The treatment was designed for high sound absorption at frequencies above 250 Hz and for withstanding the environmental conditions in the test section. In order to achieve the design requirements, a fibrous, bulk-absorber material was packed into removable panel sections. Each section was divided into two equal-depth layers packed with material to different bulk densities. The lower density was next to the facing of the treatment. The facing consisted of a perforated plate and screening material layered together. Sample tests for normal-incidence acoustic absorption were also conducted in an impedance tube to provide data to aid in the treatment design. Tests with no airflow, involving the measurement of the absorptive properties of the treatment installed in the 9- by 15-foot wind tunnel test section, combined the use of time-delay spectrometry with a previously established free-field measurement method. This new application of time-delay spectrometry enabled these free-field measurements to be made in nonanechoic conditions. The results showed that the installed acoustic treatment had absorption coefficients greater than 0.95 over the frequency range 250 Hz to 4 kHz. The measurements in the wind tunnel were in good agreement with both the analytical prediction and the impedance tube test data.

Dahl, Milo D.↗

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

Superoxide Dismutase 1 Folding Stability as a Target for Molecular Tweezers in SOD1-Related Amyotrophic Lateral Sclerosis

Protein misfolding and aggregation are hallmarks of many severe neurodegenerative diseases including Alzheimer's, Parkinson's and Huntington's disease. As a supramolecular ligand that binds to lysine and arginine residues, the molecular tweezer CLR01 was found to modify the aggregation pathway of disease-relevant proteins in vitro and in vivo with beneficial effects on toxicity. However, the molecular mechanisms of how tweezers exert these effects remain mainly unknown, hampering further drug development. Here, we investigate the modulation mechanism of unfolding and aggregation pathways of SOD1, which are involved in amyotrophic lateral sclerosis (ALS), by CLR01. Using a truncated version of the wildtype SOD1 protein, SOD1 bar , we show that CLR01 acts on the first step of the aggregation pathway, the unfolding of the SOD1 monomer. CLR01 increases, by ~10 °C, the melting temperatures of the A4V and G41D SOD1 mutants, which are commonly observed mutations in familial ALS. Molecular dynamics simulations and binding free energy calculations as well as native mass spectrometry and mutational studies allowed us to identify K61 and K92 as binding sites for the tweezers to mediate the stability increase. The data suggest that the modulation of SOD1 conformational stability is a promising target for future developments of supramolecular ligands against neurodegenerative diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Area Between Exchange Curves as a Measure of Conformational Differences in Hydrogen-Deuterium Exchange Mass Spectrometry Studies

Hydrogen-deuterium exchange mass spectrometry (HDX-MS) provides information about protein conformational mobility under native conditions. The area between exchange curves, A{sub bec}, a functional data analysis concept, was adapted to the interpretation of HDX-MS data and provides a useful measure of exchange curve dissimilarity for tests of significance. Importantly, for most globular proteins under native conditions, A{sub bec} values provide an estimate of the log ratio of exchange-competent fractions in the two states, and thus are related to differences in the free energy of microdomain unfolding. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0{sup +/−}) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0{sup +/−}/AQP1{sup +/−}) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P{sub f}) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA. Transmission and scanning electron micrographs of lenses of both mouse models showed increased extracellular space between fiber cells. Water content determination study showed increase in water in the lenses of these mouse models. In summary, lens transparency, CTCA and compact packing of fiber cells were affected due to the loss of 50% AQP0 leading to larger extracellular space, more water content and SA, possibly due to alteration in RING. To our knowledge, this is the first report identifying the role of AQP0 in RING development to ward off lens SA during focusing.

60 APPLIED LIFE SCIENCES↗