Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion↗

High-K dielectric sulfur-selenium alloys

Upcoming advancements in flexible technology require mechanically compliant dielectric materials. Current dielectrics have either high dielectric constant, K (e.g., metal oxides) or good flexibility (e.g., polymers). Here, we achieve a golden mean of these properties and obtain a lightweight, viscoelastic, high-K dielectric material by combining two nonpolar, brittle constituents, namely, sulfur (S) and selenium (Se). This S-Se alloy retains polymer-like mechanical flexibility along with a dielectric strength (40 kV/mm) and a high dielectric constant (K = 74 at 1 MHz) similar to those of established metal oxides. Our theoretical model suggests that the principal reason is the strong dipole moment generated due to the unique structural orientation between S and Se atoms. The S-Se alloys can bridge the chasm between mechanically soft and high-K dielectric materials toward several flexible device applications.

36 MATERIALS SCIENCE↗

High-resolution soft X-ray spectra of Scorpius X-1 - The structure of circumsource accreting material

Four observations of Scorpius X-1 with the Objective Grating Spectrometer of the Einstein Observatory have provided high-resolution spectra (lambda/Delta lambda = approximately 20-50) in the wavelength range 7-46 A. The spectra reveal the presence of absorption structure due to oxygen, nitrogen, and iron, and variable emission structure associated with ionized iron and nitrogen. The strengths of these features suggest that the N/O abundance ratio in the absorbing and line emitting gas is anomalously high, which might indicate that these spectral components are associated with processed material, probably accreting matter transferred from the surface of an evolved companion. Constraints on the inclination of the system, however, imply that this cool, dense, accreting material must be well out of the plane of the binary system. Possible models for the origin and nature of this circumsource medium are discussed. An extensive discussion of the calibration of the Objective Grating Spectrometer and of the analysis of spectra acquired by that instrument is also provided.

Kahn, S. M.↗

Achieving tissue-level softness on stretchable electronics through a generalizable soft interlayer design

Soft and stretchable electronics have emerged as highly promising tools for biomedical diagnosis and biological studies, as they interface intimately with the human body and other biological systems. Most stretchable electronic materials and devices, however, still have Young’s moduli orders of magnitude higher than soft bio-tissues, which limit their conformability and long-term biocompatibility. Here, we present a design strategy of soft interlayer for allowing the use of existing stretchable materials of relatively high moduli to versatilely realize stretchable devices with ultralow tissue-level moduli. We have demonstrated stretchable transistor arrays and active-matrix circuits with moduli below 10 kPa—over two orders of magnitude lower than the current state of the art. Benefiting from the increased conformability to irregular and dynamic surfaces, the ultrasoft device created with the soft interlayer design realizes electrophysiological recording on an isolated heart with high adaptability, spatial stability, and minimal influence on ventricle pressure. In vivo biocompatibility tests also demonstrate the benefit of suppressing foreign-body responses for long-term implantation. With its general applicability to diverse materials and devices, this soft-interlayer design overcomes the material-level limitation for imparting tissue-level softness to a variety of bioelectronic devices.

42 ENGINEERING↗

Final Report on Small Particle Speciation for Forensics Analysis by Soft X-ray Scanning Transmission X-ray Microscopy

Materials of interest for nuclear forensic science are often highly heterogeneous, containing complex mixtures of actinide compounds in a wide variety of matrices. Scanning transmission X-ray microscopy (STXM) is ideally suited to study such materials, as it can be used to chemically image specimens by acquiring X-ray absorption near-edge spectroscopy (XANES) data with 25 nm spatial resolution. In particular, STXM in the soft X-ray synchrotron radiation regime (approximately 120 – 2000 eV) can collect spectroscopic information from the actinides and light elements in a single experiment. Thus, STXM combines the chemical sensitivity of X-ray absorption spectroscopy with high spatial resolution in a single non-destructive characterization method. This report describes the application of STXM to a broad range of nuclear materials. Where possible, the spectroscopic images obtained by STXM are compared with information derived from other analytical methods, and used to make inferences about the process history of each material. STXM measurements can yield information including the morphology of a sample, “elemental maps” showing the spatial distribution of major chemical constituents, and XANES spectra from localized regions of a sample, which may show spatial variations in chemical composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Digital Multiphase Composites via Additive Manufacturing

Abstract Mechanical properties of traditional engineering materials are typically coupled to each other, presenting a challenge to practitioners with multi‐dimensional material property requirements. In this work, continuous, independent control over multiple mechanical properties is demonstrated in composite materials realized using additive manufacturing. For the first time, composites additively manufactured from rigid plastic, soft elastomer, and liquid constituents are experimentally characterized, demonstrating materials which span four orders of magnitude in modulus and two orders of magnitude in toughness. By forming analytical mappings between relative concentrations of constituents at the microscale and resulting macroscale material properties, inverse material design is enabled; the method is showcased by printing artifacts with prescribed toughness and elasticity distributions. The properties of these composites are placed in the context of biological tissues, showing they have promise as mechanically plausible tissue mimics.

Smith, Lawrence T.↗

Thermoplastic polyurethanes with controlled morphology based on methylenediphenyldiisocyanate/isosorbide/butanediol hard segments: Thermoplastic polyurethanes with controlled morphology

Isosorbide, a cyclic, rigid and renewable diol was used as a chain extender in two series of thermoplastic polyurethanes. Isosorbide was used in combination with butane diol or alone to examine the effects on polyurethane morphology. Two series of materials were prepared -one with dispersed hard domains in the matrix of polytetramethylene ether glycol soft segments of molecular weight 1400 (at 70% soft segment concentration-SSC) and the other with co-continuous soft and hard phases at 50% SSC. Morphology of materials was studied by optical and atomic force microscopy, as well as with ultra small angle x-ray scattering (USAXS). The radius of spherical hard domains, correlation lengths, mean separation distances and boundary layer thickness were measured as a function of isosorbide content.

chain extender↗

Design, Modeling, and Testing of a Novel Inductor for Electric Vehicles: Iron Nitride Soft Magnetic Composites

New technology for electric vehicles (EVs) must meet the requirements of higher energy usage, lower costs, and more sustainable source materials. One promising material for EV power system components is iron nitride (IN) soft magnetic composites (SMCs) because of their competitive magnetic properties and high abundance of the source materials. As part of an ongoing program at Sandia National Laboratories, this project focused on using computer modeling to optimize the prototyping process for an iron nitride SMC toroidal inductor to reach a target inductance of 600 μH. Four inductors with different combinations of wiring (26 AWG and 20 AWG) and vol% loading of iron nitride (65 vol% and 50 vol%) were fabricated at Cal Poly and characterized using an LCR meter. These inductors were also modeled using COMSOL Multiphysics™ with the Magnetic Fields module. The inductance data from the experiment and the model show that the 65 vol% IN prototypes and models agree with about 8% difference, while the 50 vol% IN samples show about a 9% difference between the prototype and the model. These results suggest that the model can predict inductance with both accuracy and precision with low confidence for the given sample size of four. An additional parameter of AC resistance is studied but the AC resistance results from the inductors and from the model generally do not agree closely, suggesting that the current model used in the project does not fully capture the mechanisms behind AC resistance of the inductor. With the focus of the project on inductance, the percent difference results of less than 9% across the four inductors that were tested increases confidence in the model’s predictive capabilities for inductance only. Using the inductance results from both the model and experiment, the final suggested inductor design is a 65 vol% core with 150 windings of 20 AWG wire that is 8 cm across and 1.5 cm tall to reach the inductance goal of 600 μH based on analysis using the optimized COMSOLTM model.

33 ADVANCED PROPULSION SYSTEMS↗

Multiferroicity in the spin-1/2 quantum matter of LiCu 2 O 2

Here, multiferroicity in LiCu 2 O 2 single crystals is studied using resonant soft x-ray magnetic scattering, hard x-ray diffraction, heat capacity, magnetic susceptibility, and electrical polarization. Two magnetic transitions are found at 24.6 K (T 1 ) and 23.2K (T 2 ). Our data are consistent with a sinusoidal spin structure at T 2 1 and with a helicoidal spin structure at T 2 , giving rise to ferroelectricity. Surprisingly, above T 2 , the correlation lengths of the spin structures increase as the temperature increases with dramatic changes of ~42% occurring along the c axis.

36 MATERIALS SCIENCE↗

Soft X-ray spectroscopy with transition-edge sensors at Stanford Synchrotron Radiation Lightsource beamline 10-1

We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10 –3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for synchrotron-based X-ray spectroscopy. Here, the results from initial X-ray emission spectroscopy and resonant inelastic X-ray scattering experiments obtained with the spectrometer are presented.

47 OTHER INSTRUMENTATION↗

Ordered Nanostructured Amphiphile Self-Assembly Materials from Endogenous Nonionic Unsaturated Monoethanolamide Lipids in Water

The self-assembly, solid state and lyotropic liquid crystalline phase behavior of a series of endogenous n-acylethanolamides (NAEs) with differing degrees of unsaturation, viz., oleoyl monoethanolamide, linoleoyl monoethanolamide, and linolenoyl monoethanolamide, have been examined. The studied molecules are known to possess inherent biological function. Both the monoethanolamide headgroup and the unsaturated hydrophobe are found to be important in dictating the self-assembly behavior of these molecules. In addition, all three molecules form lyotropic liquid crystalline phases in water, including the inverse bicontinuous cubic diamond (Q{sub II}{sup D}) and gyroid (Q{sub II}{sup G}) phases. The ability of the NAE's to form inverse cubic phases and to be dispersed into ordered nanostructured colloidal particles, cubosomes, in excess water, combined with their endogenous nature and natural medicinal properties, makes this new class of soft mesoporous amphiphile self-assembly materials suitable candidates for investigation in a variety of advanced multifunctional applications, including encapsulation and controlled release of therapeutic agents and incorporation of medical imaging agents.

59 BASIC BIOLOGICAL SCIENCES↗

Strain Amplification of the 4 k F Chain Instability in Sr 14 Cu 24 O 41

In this work, we used resonant soft x-ray scattering to study the chain ordering in ${\mathrm{Sr}}_{14}{\mathrm{Cu}}_{24}{\mathrm{O}}_{41}$ (SCO). We observed, for the first time, both the chain and ladder orders in SCO with the same probe. We found that the chain modulation in SCO is incommensurate with wave vector ${L}_{c}=0.318$, is strongly temperature ($T$) dependent, and is accompanied by a substantial hole modulation. By contrast, the chain modulation in a hole-depleted control sample ${\mathrm{La}}_{6}{\mathrm{Ca}}_{8}{\mathrm{Cu}}_{24}{\mathrm{O}}_{41}$ was commensurate (${L}_{c}=0.3$), $T$ independent, and purely structural. We conclude that the chain charge order in SCO is a $4{k}_{F}$ charge density wave stabilized by the misfit strain between the ladder and chain substructures.

36 MATERIALS SCIENCE↗

PET/CT for Radiotherapy Treatment Planning in Patients With Soft Tissue Sarcomas

Purpose: To study the possibility of incorporating positron emission tomography/computed tomography (PET/CT) information into radiotherapy treatment planning in patients with high-grade soft tissue sarcomas (STS). Methods and Materials: We studied 17 patients treated with preoperative radiotherapy at our institution from 2005 to 2007. All patients had a high-grade STS and had had a staging PET/CT scan. For each patient, an MRI-based gross tumor volume (GTV), considered to be the contemporary standard for radiotherapy treatment planning, was outlined on a T1-gadolinium enhanced axial MRI (GTV{sub MRI}), and a second set of GTVs were outlined using different threshold values on PET images (GTV{sub PET}). PET-based target volumes were compared with the MRI-based GTV. Threshold values for target contouring were determined as a multiple (from 2 to 10 times) of the background soft tissue uptake values (B) sampled over healthy tissue. Results: PET-based GTVs contoured using a threshold value of 2 or 2.5 most closely resembled the GTV{sub MRI} volumes. Higher threshold values lead to PET volumes much smaller than the GTV{sub MRI}. The standard deviations between the average volumes of GTV{sub PET} and GTV{sub MRI} ratios for all thresholds were large, ranging from 36% for 2 xB up to 93% for 10 xB. Maximum uptake-to-background ratio correlated poorly with the maximum standardized uptake values. Conclusions: It is unlikely that PET/CT will make a significant contribution in GTV definition for radiotherapy treatment planning in patients with STS using threshold methods on PET images. Future studies will focus on molecular imaging and tumor physiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kelvin probe force microscopy under ambient conditions

Kelvin probe force microscopy (KPFM) is a technique derived from atomic force microscopy that provides maps of surface potential or work function differences across material systems, with nanometre-scale resolution. KPFM is a useful tool for investigating electrical phenomena such as dipole orientation, interfacial charge transfer, charge accumulation, band bending and doping levels. This Primer aims to provide an overview of typical ambient-condition KPFM measurements, covering their underlying principles, experimental implementations and wide-ranging applications. Key KPFM variants, including amplitude and frequency modulation, heterodyne detection schemes and innovative open loop and pulsed force techniques, are discussed, with practical guidance on optimizing signal acquisition and reducing errors. Specialized approaches, such as time-resolved KPFM and multimodal KPFM, are discussed for their ability to capture dynamic charge processes and chemical information, respectively. Here, we highlight recent advances in KPFM applications, spanning metal alloys, soft matter, ferroelectrics, photovoltaics and 2D materials, showcasing its versatility across research domains. By addressing current limitations and identifying future opportunities, this Primer underscores the transformative potential of KPFM in advancing the understanding of nanoscale electrical phenomena.

Zahmatkeshsaredorahi, Amirhossein [Lehigh Univ., B↗

Ingeniously enhanced ferromagnetism in chemically-reduced 2D Ti 3 C 2 T X MXene

Chemical reduction is a facile and cost-effective technique for the modulation of the physical and chemical properties of nanomaterials. In this work, we demonstrate an enhancement of the magnetic behavior of Ti 3 C 2 T x MXene after its chemical reduction via l-ascorbic acid treatment. Small ferromagnetic loops have been observed below 50 K for Ti 3 C 2 T x prepared by hydrofluoric acid (HF) etching of Al layers from Ti 3 AlC 2 . Such a ferromagnetic ordering of spins was significantly enhanced via a chemical reduction of Ti 3 C 2 T x with l-ascorbic acid. Ferromagnetic hysteresis loops were observed for reduced Ti 3 C 2 T x (r-Ti 3 C 2 T x ) up to 150 K indicating a significant upshift of the paramagnetic to the ferromagnetic transition temperature, pushing towards room temperature. The enhancement of ferromagnetism and upshift of the ferromagnetic transition temperature could be attributed to the localized unpaired electron in Ti-3d orbital of the r-Ti 3 C 2 T x crystal and increase in the number of unsaturated Ti atoms upon l-ascorbic acid treatment. Chemical reduction via l-ascorbic acid treatment shows a promising pathway towards the modulation and enhancement of magnetism in various MXene materials for the development of 2D metallic soft ferromagnets and spintronic devices.

36 MATERIALS SCIENCE↗